1. Overview
Thank you for selecting the EPEVER ViewStar AU series common positive solar charge controller. The VS-AU controller is a Pulse Width Modulation (PWM) charge controller featuring a built-in LCD display and advanced digital techniques. Its versatile load control modes make it suitable for various applications, including solar home systems, traffic signals, solar street lights, and garden lamps.
Key Features:
- Utilizes high-quality components from ST, IR, and Infineon for enhanced lifespan and reliability.
- UL and VDE certified terminals for increased safety.
- Capable of continuous full-load operation within an environmental temperature range of -25°C to 55°C.
- 3-Stage intelligent PWM charging: Bulk, Boost/Equalize, and Float.
- Supports three battery charging options: Sealed, Gel, and Flooded.
- LCD display dynamically shows operating data and working conditions.
- Dual USB ports (5VDC/2.4A) for charging electronic equipment.
- User-friendly button settings for comfortable and convenient operation.
- Multiple load control modes for diverse applications.
- Energy statistics function for monitoring system performance.
- Battery temperature compensation function for optimized charging.
- Extensive electronic protection features.
2. Product Features and Components
The EPEVER ViewStar AU series solar charge controller features a clear LCD display and intuitive controls. Below is a diagram illustrating the main components and their functions.

Figure 1: Front Panel Components of the VS-AU Series Controller
Component Descriptions:
- LCD: Liquid Crystal Display for showing system status and parameters.
- MENU Button: Used to browse interfaces and set parameters.
- RTS Port: Remote Temperature Sensor port for connecting the optional temperature sensor.
- PV Terminals: Input terminals for connecting the solar photovoltaic (PV) array.
- Battery Terminals: Terminals for connecting the battery bank.
- Load Terminals: Output terminals for connecting DC loads.
- SET Button: Used for Load ON/OFF, clearing errors, entering set mode, and saving data.
- USB Output Ports: Provides 5VDC/2.4A power supply for electronic devices, with short circuit protection.
Optional Accessory: Remote Temperature Sensor (RTS)
- Name: Remote Temperature Sensor
- Model: RTS300R47K3.81A
- Function: Acquires battery temperature for accurate temperature compensation of control parameters.
- Cable Length: Standard 3m (length can be customized).
- Connection: Connects to the RTS Port (3) on the controller.
- Note: If the RTS is unplugged, the battery temperature will default to a fixed value of 25°C.
3. Setup (Wiring Instructions)
Proper wiring is crucial for the safe and efficient operation of your solar charge controller. Please follow the steps below carefully.

Figure 2: Connection Diagram for VS-AU Series Controller
Wiring Sequence:
- Connect the Battery (1): Connect the battery to the controller's battery terminals first. Ensure correct polarity (+ and -). This allows the controller to recognize the system voltage.
- Connect the PV Array (3): Connect the solar photovoltaic (PV) array to the controller's PV terminals. Observe correct polarity.
- Connect the Load (2): Connect the DC load to the controller's load terminals. Ensure correct polarity.
Important Safety Notes:
- Always connect components in the sequence shown above.
- Pay close attention to the correct "+" and "-" polarities for all connections.
- Do NOT insert fuses or turn on any breakers during the installation process.
- When disconnecting the system, reverse the connection order (Load first, then PV, then Battery).
- Battery Fuse: The battery fuse should be installed as close to the battery as possible, with a suggested distance of within 150mm.
- Grounding: The VS-AU series is a positive ground controller. Any positive connection of solar, load, or battery can be earth-grounded as required.
- Inverters/Large Loads: If you are connecting an inverter or any other load with a large start-up current, connect it directly to the battery terminals, not through the controller.
4. Operation
4.1 Button Functions
| Button | Function |
|---|---|
| MENU Button | Browse interface, Setting parameter |
| SET Button | Load ON/OFF, Clear error, Enter into Set Mode, Save data |
4.2 LCD Display and Status Description
The LCD dynamically displays the device's operating data and working conditions. Icons indicate various statuses:
| Item | Icon | Status |
|---|---|---|
| Time | (Sun icon) | Day |
| (Moon icon) | Night | |
| PV Array | (PV panel icon, no arrow) | No charging |
| (PV panel icon, arrow to battery) | Charging | |
| PV | PV Voltage, Current, Power | |
| Battery | (Battery icon) | Battery capacity, In Charging |
| BATT. | Battery voltage, current, temperature | |
| BATT. TYPE | Battery type | |
| Load | (Light bulb icon, ON) | Load ON |
| (Light bulb icon, OFF) | Load OFF | |
| LOAD | Load Voltage, Current, Load mode |
When no operation, the interface will cycle automatically through various displays. You can manually browse using the MENU button.
Accumulative Power Zero Clearing: Under the PV power interface, press and hold the SET button for 5 seconds until the value blinks. Press SET button again to clear the value.
Setting Temperature Unit: Under the battery temperature interface, press and hold the SET button for 5 seconds to switch between °C and °F.
4.3 Load Mode Setting
This setting controls how the load output behaves. To enter load mode setting: Under the load mode setting interface, press and hold the SET button for 5 seconds until the number starts flashing. Then, use the MENU button to set the parameter and press SET button to confirm.
| Timer 1 Setting | Description | Timer 2 Setting | Description |
|---|---|---|---|
| 0 | Light ON/OFF | 0 | Disabled |
| 1-15 | Load ON for 1-15 hours since sunset | 1-15 | Load ON for 1-15 hours before sunrise |
| 16 | Test mode | 0 | Disabled |
| 17 | Manual mode (Default: Load ON) | 0 | Disabled |
Note: For Light ON/OFF, Test mode, and Manual mode, Timer 2 will be disabled and display "2 n".
4.4 Battery Type Setting
It is crucial to select the correct battery type for optimal charging and battery lifespan. To set the battery type: Under the Battery Voltage interface, press and hold the SET button for 5 seconds to enter the Battery type setting interface. Use the MENU button to choose the battery type (Sealed, Gel, or Flooded). Wait for 5 seconds or press SET button again to confirm the modification.
- SEL: Sealed (Default)
- GEL: Gel
- FLO: Flooded
Note: Refer to the battery voltage parameters table in the full manual for specific voltage settings for each battery type.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your EPEVER solar charge controller and the entire solar system.
- Check Connections: Periodically inspect all wiring connections (PV, battery, load) to ensure they are clean, tight, and free from corrosion. Loose connections can cause voltage drops and overheating.
- Inspect Wiring: Check all cables for any signs of damage, fraying, or wear. Replace damaged cables immediately.
- Clean Controller: Keep the controller free from dust, dirt, and debris. Use a soft, dry cloth to clean the exterior. Ensure ventilation openings are not blocked.
- Monitor Performance: Regularly check the LCD display for system status, voltage, current, and any fault indications. Ensure the controller is operating within expected parameters.
- Environmental Check: Ensure the controller is installed in a well-ventilated area, away from direct sunlight, moisture, and corrosive environments.
6. Troubleshooting
This section provides solutions to common issues you might encounter with your EPEVER VS-AU series solar charge controller.
| Fault | Possible Reasons | Troubleshooting |
|---|---|---|
| LCD is off during daytime with sunshine | PV array disconnection | Confirm PV wire connections are correct and tight. |
| Wire connection correct, LCD not displaying | 1) Battery voltage lower than 9V 2) PV voltage less than battery voltage | 1) Check battery voltage (min 9V to activate). 2) Check PV input voltage (must be higher than battery). |
| Interface blink (Battery over voltage) | Battery over voltage | Check if battery voltage is higher than OVD point; disconnect PV. |
| Interface blink (Battery over discharged) | Battery over discharged | Load will recover when battery voltage restores to or above LVR point. |
| Interface blink (Battery Overheating) | Battery Overheating | Controller will automatically turn off; resumes when temperature drops below 50°C. |
| Interface blink (Over load or Short circuit) | Over load or Short circuit | Reduce number of electric equipment or check load connections. |
7. Specifications
Below are key technical specifications for the EPEVER ViewStar AU series solar charge controllers. For a complete and detailed list, please refer to the official PDF user manual.
| Parameter | VS1024AU / VS2024AU | VS3024AU / VS4524AU / VS6024AU |
|---|---|---|
| Nominal System Voltage | 12/24VDC Auto | 12/24VDC Auto |
| Battery Input Voltage Range | 9V ~ 32V | 9V ~ 32V |
| Rated Charge/Discharge Current | 10A / 20A | 30A / 45A / 60A |
| Max. PV Open Circuit Voltage | 50V | 50V |
| Battery Type | Sealed (Default) / Gel / Flooded | |
| Equalize Charging Voltage | Sealed:14.6V/ Gel: No/ Flooded:14.8V (12V system) | |
| Boost Charging Voltage | Sealed:14.4V/Gel:14.2V/ Flooded:14.6V (12V system) | |
| Float Charging Voltage | Sealed/Gel/Flooded:13.8V (12V system) | |
| Low Voltage Reconnect Voltage | Sealed/Gel/Flooded:12.6V (12V system) | |
| Low Voltage Disconnect Voltage | Sealed/Gel/Flooded:11.1V (12V system) | |
| Self-consumption | ≤9.2mA/12V; ≤11.7mA/24V; ≤14.5mA/36V; ≤17mA/48V | |
| Temperature Compensation Coefficient | -3mV/°C/2V (25°C) | |
| USB Output | 5VDC/2.4A (Total) | |
| Working Environment Temperature | -25°C ~ +55°C | |
| Enclosure | IP30 | |
| Grounding | Common Positive | |
Note: Parameters are for 12V system at 25°C. Values are doubled for 24V, tripled for 36V, and quadrupled for 48V systems.
8. User Tips
To get the best performance and lifespan from your EPEVER ViewStar AU series solar charge controller, consider the following user tips:
- Battery First: Always remember to connect the battery to the controller before connecting solar panels or loads. This ensures the controller correctly identifies the system voltage.
- Correct Battery Type: Double-check that you have selected the correct battery type (Sealed, Gel, or Flooded) in the controller settings. An incorrect setting can lead to improper charging and reduced battery life.
- Regular Checks: Periodically inspect all wiring connections for tightness and corrosion. Loose connections can cause system inefficiencies or even damage.
- Monitor Performance: Utilize the LCD display to regularly monitor your system's voltage, current, and overall status. This helps in early detection of any potential issues.
- Ventilation: Ensure the controller is installed in a location with adequate airflow to prevent overheating, especially during high-current operation.
- Fuse Protection: Always use appropriate fuses on the battery line, as close to the battery as possible, to protect against short circuits.
9. Warranty and Support
EPEVER provides a warranty for its products under normal use and service. Please note that the warranty does not apply under the following conditions:
- Damage resulting from improper use or operation in an unsuitable environment.
- PV or load current, voltage, or power exceeding the controller's rated values.
- Controller operating temperature exceeding the specified limit.
- Unauthorized disassembly or attempted repair of the controller by the user.
- Damage caused by natural elements (e.g., lightning).
- Damage incurred during transportation or shipment.
For detailed warranty terms, technical support, and further information, please refer to the official EPEVER documentation.
Official User Manual (PDF): A comprehensive user manual in PDF format is available for download. It contains more detailed information on advanced settings, specific voltage parameters, and safety guidelines.