EPever UP1500-M3222

Contents

EPever UPower Series Hybrid Solar Inverter/Charger Instruction Manual

Models: UP1000-M3212, UP1000-M3222, UP1500-M3222, UP2000-M3322

Brand: EPever

1. Introduction

The EPever UPower series is an advanced inverter/charger system designed for intelligent energy storage and management. It integrates an MPPT solar charge controller, a pure sine wave inverter, and an AC/DC charger into a single, compact unit. This series, ranging from 1KVA to 5KVA, is ideal for residential applications, schools, cottages, and areas with unstable electricity grids, providing reliable and uninterruptible power.

The inverter and AC/DC charger can operate simultaneously, offering flexible power management solutions.

Front view of the EPever UPower inverter/charger

Figure 1: Front view of the EPever UPower Inverter/Charger

Diagram showing the internal components and power flow of the UPower system

Figure 2: Internal block diagram of the UPower system, illustrating power flow between PV array, utility, generator, battery, and AC loads.

2. Setup

Before installation, ensure all components are present and undamaged. Installation should be performed by qualified personnel following local electrical codes and safety regulations.

2.1 Component Identification

Refer to the diagram below for identification of the inverter/charger's rear panel terminals and interfaces:

Detailed rear view of the UPower inverter/charger with numbered labels for each terminal and interface.

Figure 3: Rear panel layout and terminal identification

  1. Ventilation
  2. M4 Screw (2 pcs)
  3. AC Output Terminals
  4. Utility Input Terminals
  5. Battery Input Terminals
  6. RTS Interface (Remote Temperature Sensor)
  7. Dry Contact Interface
  8. Remote Interface
  9. RS485 Interface (5VDC/200mA)
  10. Inverter/Charger Switch
  11. PV Input Terminals
  12. Terminals Cover

2.2 Wiring Connections

Ensure the Inverter/Charger Switch (10) is in the 'OFF' position before making any connections. Always connect the battery first, then solar panels, and finally AC inputs/outputs.

2.2.1 Battery Connection

Connect your battery bank to the Battery Input Terminals (5). Ensure correct polarity. The system supports 12VDC or 24VDC nominal battery voltages depending on the model.

2.2.2 Solar Panel (PV) Connection

Connect your solar panels to the PV Input Terminals (11). Observe maximum PV open circuit voltage and input power limits as specified in the Technical Specifications section.

2.2.3 AC Input (Utility/Generator) Connection

The UPower series can connect to either a utility grid or a generator for AC charging and backup. Note that utility power supply and battery power supply cannot be carried out simultaneously for direct load powering.

Wiring diagram for connecting the inverter/charger to the utility grid.

Figure 4: Connection to Utility Grid

Wiring diagram for connecting the inverter/charger to a generator.

Figure 5: Connection to Generator

Connect the utility grid or generator to the Utility Input Terminals (4).

Diagram illustrating that utility and battery power supply cannot be used simultaneously to power loads.

Figure 6: Important note on simultaneous power sources

2.2.4 AC Output (Load) Connection

Connect your AC loads to the AC Output Terminals (3).

2.3 Communication Connections

The inverter/charger supports various communication options for monitoring and control:

  • RS485 Interface (9): For wired communication with a PC or other devices.
  • Remote Interface (8): For connecting remote monitoring accessories.
  • Optional WiFi/GPRS Modules: For wireless monitoring via a mobile app.
Diagram showing communication options for the inverter/charger, including PC via USB/RJ45 and APP via EPEVER WiFi 2.4G RJ45.

Figure 7: Communication options for monitoring and control

3. Operating Instructions

The UPower series features an all-digital intelligent energy storage and management system with an LCD display for easy monitoring and configuration.

3.1 Powering On/Off

  1. After all connections are secure, switch the Inverter/Charger Switch (10) to the 'ON' position.
  2. The LCD display will illuminate, indicating the system is starting up.
  3. To power off, switch the Inverter/Charger Switch (10) to the 'OFF' position.

3.2 Charging Modes

The UPower series offers four distinct charging modes, configurable via the device's interface or connected software:

  • Utility Priority: Prioritizes charging from the utility grid.
  • Solar Priority: Prioritizes charging from solar panels.
  • Utility & Solar: Utilizes both utility and solar power for charging.
  • Solar Only: Charges exclusively from solar panels.

3.3 Output Modes

The system supports two output modes:

  • Battery: Loads are powered directly from the battery bank via the inverter.
  • Utility: Loads are powered from the utility grid (when available).

3.4 Advanced Features

  • MPPT Technology: Advanced Maximum Power Point Tracking ensures maximum energy harvest from solar panels with up to 99.5% tracking efficiency.
  • DC-DC Conversion: High DC-DC conversion efficiency of up to 98.5%.
  • Charging Ratio Selection: Allows selection of utility and solar charging ratios.
  • Total Charging Current Setting: Configurable total charging current.
  • Rich Options: Customizable settings for charging current, battery type, and battery voltage threshold.
Image detailing various features of the UPower series, including MPPT efficiency, DC-DC conversion, charging modes, and output modes.

Figure 8: Key features of the UPower series

Image highlighting additional features like rich set of options, RS485 communication, and extensive electronic protection.

Figure 9: Additional features and protection mechanisms

4. Maintenance

Regular maintenance ensures optimal performance and longevity of your UPower inverter/charger.

  • Cleaning: Keep the unit clean and free from dust. Ensure the ventilation openings (1) are unobstructed to prevent overheating.
  • Connections: Periodically check all wiring connections (battery, solar, AC input/output) for tightness and corrosion.
  • Environment: Ensure the operating environment is within the specified temperature range (-20℃ to 50℃) and free from excessive moisture or direct sunlight. The enclosure rating is IP30, meaning it is protected from solid objects over 2.5mm but not from liquids.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your unit has the latest features and bug fixes.

5. Troubleshooting

This section provides general guidance for common issues. For complex problems, contact technical support.

  • No Power/Display Off: Check the Inverter/Charger Switch (10) is ON. Verify battery connections and charge level. Ensure AC input (utility/generator) is present if configured.
  • No AC Output: Check AC output connections. Verify the inverter is operating and not in a fault state (check LCD for error codes). Ensure battery voltage is within operating limits.
  • Charging Issues: Verify solar panel connections and ensure sufficient sunlight. Check utility/generator input if AC charging is enabled. Ensure battery type settings are correct.
  • Overload Protection: If the unit shuts down due to overload, reduce the connected load. The unit has extensive electronic protection, including short circuit and battery reverse polarity protections.
  • Communication Failure: Check RS485 cable connections. Ensure communication modules (WiFi/GPRS) are correctly installed and configured.

6. Specifications

Detailed technical specifications for the UPower series inverter/chargers:

FeatureUP1000-M3212UP1000-M3222UP1500-M3222UP2000-M3322
Nominal battery voltage12VDC24VDC24VDC24VDC
Battery input voltage range10.8~16VDC21.6~32VDC21.6~32VDC21.6~32VDC
Inverter Output
Continuous output power800W800W1200W1600W
Output power 15min.1000W1000W1500W2000W
Output voltage range220V(-6%~+5%) 230V(-10%~+5%)220V±5%;230V (-10%~+5%)220V±5%;230V (-10%~+5%)220V±5%;230V (-10%~+5%)
Output frequency50/60±0.1Hz
Output modeSingle phase
Output wavePure Sine Wave
Distortion THD≤3%(12V or 24V resistive load)
Max. efficiency91%94%95%95%
Utility Charging
Utility input voltage range160VAC~280VAC (Working voltage range); 170VAC~270VAC (Utility starting voltage range)
Max. utility charge current20A20A20A30A
Solar Charging
Max. PV open circuit voltage60V (At minimum operating environment temperature); 46V (At 25℃ environment temperature)100V (At minimum operating environment temperature); 92V (At 25℃ environment temperature)
Max. PV input power390W780W780W780W
Max. PV charging current30A30A30A30A
Equalization voltageSealed:14.6V, Flooded:14.8VSealed:29.2V,Flooded:29.6V
Boost voltageGel:14.2V, Sealed:14.4V, Flooded:14.6VGel:28.4V,Sealed:28.8V,Flooded:29.2V
Float voltageGel/Sealed/ Flooded:13.8VGel/Sealed/Flooded:27.6V
Tracking efficiency≤99.5%
Charging conversion efficiency≤98%
Temperature compensation-3mV/℃/2V (Default)
Other
No load consumption≤1.2A≤0.6A≤0.6A≤0.8A
EnclosureIP30
Operating temperature range-20℃~50℃ (full input and output with no derating)
Dimensions (HxWxL)386×300×126mm386×300×126mm386×300×126mm444×300×126mm
Net weight7.3kg7.3kg7.4kg8.5kg

7. Warranty and Support

The EPever UPower series comes with a 2-year warranty. For technical support, troubleshooting assistance, or warranty claims, please contact your vendor or the manufacturer directly. Ensure you have your product model and serial number available.

7.1 Certifications

The UPower series is certified to meet various international standards, ensuring quality and safety.

Certifications image showing various compliance logos like CE and ROHS.

Figure 10: Product Certifications

Image displaying various product certificates.

Figure 11: Various product certificates

8. User Tips

  • Optimize Solar Input: Position solar panels to maximize sun exposure throughout the day for efficient charging.
  • Battery Health: Use appropriate battery type settings (Gel, Sealed, Flooded) to ensure correct charging voltages and prolong battery lifespan.
  • Load Management: Monitor your AC loads to avoid exceeding the inverter's continuous output power, especially during peak usage.
  • Remote Monitoring: Utilize the RS485 interface or optional WiFi/GPRS modules for remote monitoring of system performance and settings, which can help in proactive maintenance and troubleshooting.
  • Grounding: Ensure proper grounding of the system for safety and optimal performance.

9. Application Scenarios

The UPower series is versatile and suitable for a wide range of applications:

  • Solar RV systems
  • Solar boat systems
  • Off-grid solar homes
  • Solar wind energy hybrid systems
  • Solar camping systems
  • Solar monitoring systems
  • Solar marine systems
  • Solar street lighting systems
  • General household appliances, electric tools, and commercial units
Collage of images showing various application scenarios for solar power, including RVs, boats, homes, and wind energy setups.

Figure 12: Diverse application scenarios for UPower systems

Collage of images showing more application scenarios for solar power, including home systems, camping, monitoring, marine, RV, and street lighting.

Figure 13: Extended application examples

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.