1. Introduction
The EPever UPower series is an advanced inverter/charger system designed for intelligent energy storage and management. It integrates an MPPT solar charge controller, a pure sine wave inverter, and an AC/DC charger into a single, compact unit. This series, ranging from 1KVA to 5KVA, is ideal for residential applications, schools, cottages, and areas with unstable electricity grids, providing reliable and uninterruptible power.
The inverter and AC/DC charger can operate simultaneously, offering flexible power management solutions.

Figure 1: Front view of the EPever UPower Inverter/Charger

Figure 2: Internal block diagram of the UPower system, illustrating power flow between PV array, utility, generator, battery, and AC loads.
2. Setup
Before installation, ensure all components are present and undamaged. Installation should be performed by qualified personnel following local electrical codes and safety regulations.
2.1 Component Identification
Refer to the diagram below for identification of the inverter/charger's rear panel terminals and interfaces:

Figure 3: Rear panel layout and terminal identification
- Ventilation
- M4 Screw (2 pcs)
- AC Output Terminals
- Utility Input Terminals
- Battery Input Terminals
- RTS Interface (Remote Temperature Sensor)
- Dry Contact Interface
- Remote Interface
- RS485 Interface (5VDC/200mA)
- Inverter/Charger Switch
- PV Input Terminals
- Terminals Cover
2.2 Wiring Connections
Ensure the Inverter/Charger Switch (10) is in the 'OFF' position before making any connections. Always connect the battery first, then solar panels, and finally AC inputs/outputs.
2.2.1 Battery Connection
Connect your battery bank to the Battery Input Terminals (5). Ensure correct polarity. The system supports 12VDC or 24VDC nominal battery voltages depending on the model.
2.2.2 Solar Panel (PV) Connection
Connect your solar panels to the PV Input Terminals (11). Observe maximum PV open circuit voltage and input power limits as specified in the Technical Specifications section.
2.2.3 AC Input (Utility/Generator) Connection
The UPower series can connect to either a utility grid or a generator for AC charging and backup. Note that utility power supply and battery power supply cannot be carried out simultaneously for direct load powering.

Figure 4: Connection to Utility Grid

Figure 5: Connection to Generator
Connect the utility grid or generator to the Utility Input Terminals (4).

Figure 6: Important note on simultaneous power sources
2.2.4 AC Output (Load) Connection
Connect your AC loads to the AC Output Terminals (3).
2.3 Communication Connections
The inverter/charger supports various communication options for monitoring and control:
- RS485 Interface (9): For wired communication with a PC or other devices.
- Remote Interface (8): For connecting remote monitoring accessories.
- Optional WiFi/GPRS Modules: For wireless monitoring via a mobile app.

Figure 7: Communication options for monitoring and control
3. Operating Instructions
The UPower series features an all-digital intelligent energy storage and management system with an LCD display for easy monitoring and configuration.
3.1 Powering On/Off
- After all connections are secure, switch the Inverter/Charger Switch (10) to the 'ON' position.
- The LCD display will illuminate, indicating the system is starting up.
- To power off, switch the Inverter/Charger Switch (10) to the 'OFF' position.
3.2 Charging Modes
The UPower series offers four distinct charging modes, configurable via the device's interface or connected software:
- Utility Priority: Prioritizes charging from the utility grid.
- Solar Priority: Prioritizes charging from solar panels.
- Utility & Solar: Utilizes both utility and solar power for charging.
- Solar Only: Charges exclusively from solar panels.
3.3 Output Modes
The system supports two output modes:
- Battery: Loads are powered directly from the battery bank via the inverter.
- Utility: Loads are powered from the utility grid (when available).
3.4 Advanced Features
- MPPT Technology: Advanced Maximum Power Point Tracking ensures maximum energy harvest from solar panels with up to 99.5% tracking efficiency.
- DC-DC Conversion: High DC-DC conversion efficiency of up to 98.5%.
- Charging Ratio Selection: Allows selection of utility and solar charging ratios.
- Total Charging Current Setting: Configurable total charging current.
- Rich Options: Customizable settings for charging current, battery type, and battery voltage threshold.

Figure 8: Key features of the UPower series

Figure 9: Additional features and protection mechanisms
4. Maintenance
Regular maintenance ensures optimal performance and longevity of your UPower inverter/charger.
- Cleaning: Keep the unit clean and free from dust. Ensure the ventilation openings (1) are unobstructed to prevent overheating.
- Connections: Periodically check all wiring connections (battery, solar, AC input/output) for tightness and corrosion.
- Environment: Ensure the operating environment is within the specified temperature range (-20℃ to 50℃) and free from excessive moisture or direct sunlight. The enclosure rating is IP30, meaning it is protected from solid objects over 2.5mm but not from liquids.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your unit has the latest features and bug fixes.
5. Troubleshooting
This section provides general guidance for common issues. For complex problems, contact technical support.
- No Power/Display Off: Check the Inverter/Charger Switch (10) is ON. Verify battery connections and charge level. Ensure AC input (utility/generator) is present if configured.
- No AC Output: Check AC output connections. Verify the inverter is operating and not in a fault state (check LCD for error codes). Ensure battery voltage is within operating limits.
- Charging Issues: Verify solar panel connections and ensure sufficient sunlight. Check utility/generator input if AC charging is enabled. Ensure battery type settings are correct.
- Overload Protection: If the unit shuts down due to overload, reduce the connected load. The unit has extensive electronic protection, including short circuit and battery reverse polarity protections.
- Communication Failure: Check RS485 cable connections. Ensure communication modules (WiFi/GPRS) are correctly installed and configured.
6. Specifications
Detailed technical specifications for the UPower series inverter/chargers:
| Feature | UP1000-M3212 | UP1000-M3222 | UP1500-M3222 | UP2000-M3322 |
|---|---|---|---|---|
| Nominal battery voltage | 12VDC | 24VDC | 24VDC | 24VDC |
| Battery input voltage range | 10.8~16VDC | 21.6~32VDC | 21.6~32VDC | 21.6~32VDC |
| Inverter Output | ||||
| Continuous output power | 800W | 800W | 1200W | 1600W |
| Output power 15min. | 1000W | 1000W | 1500W | 2000W |
| Output voltage range | 220V(-6%~+5%) 230V(-10%~+5%) | 220V±5%;230V (-10%~+5%) | 220V±5%;230V (-10%~+5%) | 220V±5%;230V (-10%~+5%) |
| Output frequency | 50/60±0.1Hz | |||
| Output mode | Single phase | |||
| Output wave | Pure Sine Wave | |||
| Distortion THD | ≤3%(12V or 24V resistive load) | |||
| Max. efficiency | 91% | 94% | 95% | 95% |
| Utility Charging | ||||
| Utility input voltage range | 160VAC~280VAC (Working voltage range); 170VAC~270VAC (Utility starting voltage range) | |||
| Max. utility charge current | 20A | 20A | 20A | 30A |
| Solar Charging | ||||
| Max. PV open circuit voltage | 60V (At minimum operating environment temperature); 46V (At 25℃ environment temperature) | 100V (At minimum operating environment temperature); 92V (At 25℃ environment temperature) | ||
| Max. PV input power | 390W | 780W | 780W | 780W |
| Max. PV charging current | 30A | 30A | 30A | 30A |
| Equalization voltage | Sealed:14.6V, Flooded:14.8V | Sealed:29.2V,Flooded:29.6V | ||
| Boost voltage | Gel:14.2V, Sealed:14.4V, Flooded:14.6V | Gel:28.4V,Sealed:28.8V,Flooded:29.2V | ||
| Float voltage | Gel/Sealed/ Flooded:13.8V | Gel/Sealed/Flooded:27.6V | ||
| Tracking efficiency | ≤99.5% | |||
| Charging conversion efficiency | ≤98% | |||
| Temperature compensation | -3mV/℃/2V (Default) | |||
| Other | ||||
| No load consumption | ≤1.2A | ≤0.6A | ≤0.6A | ≤0.8A |
| Enclosure | IP30 | |||
| Operating temperature range | -20℃~50℃ (full input and output with no derating) | |||
| Dimensions (HxWxL) | 386×300×126mm | 386×300×126mm | 386×300×126mm | 444×300×126mm |
| Net weight | 7.3kg | 7.3kg | 7.4kg | 8.5kg |
7. Warranty and Support
The EPever UPower series comes with a 2-year warranty. For technical support, troubleshooting assistance, or warranty claims, please contact your vendor or the manufacturer directly. Ensure you have your product model and serial number available.
7.1 Certifications
The UPower series is certified to meet various international standards, ensuring quality and safety.

Figure 10: Product Certifications

Figure 11: Various product certificates
8. User Tips
- Optimize Solar Input: Position solar panels to maximize sun exposure throughout the day for efficient charging.
- Battery Health: Use appropriate battery type settings (Gel, Sealed, Flooded) to ensure correct charging voltages and prolong battery lifespan.
- Load Management: Monitor your AC loads to avoid exceeding the inverter's continuous output power, especially during peak usage.
- Remote Monitoring: Utilize the RS485 interface or optional WiFi/GPRS modules for remote monitoring of system performance and settings, which can help in proactive maintenance and troubleshooting.
- Grounding: Ensure proper grounding of the system for safety and optimal performance.
9. Application Scenarios
The UPower series is versatile and suitable for a wide range of applications:
- Solar RV systems
- Solar boat systems
- Off-grid solar homes
- Solar wind energy hybrid systems
- Solar camping systems
- Solar monitoring systems
- Solar marine systems
- Solar street lighting systems
- General household appliances, electric tools, and commercial units

Figure 12: Diverse application scenarios for UPower systems

Figure 13: Extended application examples