1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the EPever EPIPDB-COM series Dual Battery Solar Controller. This high-efficiency PWM charging regulator is designed for solar systems and solar working stations, capable of managing charging for two independent battery banks (12V/24V auto-sensing) with current ratings of 10A or 20A. It can optionally be connected to a remote display unit (MT-1) and a remote temperature sensor for enhanced monitoring and control.
2. Safety Information
WARNING: Do not install the controller in humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other severe environments. Failure to observe this warning may result in damage to the controller or personal injury.
CAUTION: The EPIPDB-COM series controllers are common-negative. For common-negative systems (e.g., RV systems), using a common-negative controller is recommended. Using a common-positive controller with a grounded positive electrode in a common-negative system may damage the controller. The grounding terminal on the controller shell must be grounded to shield electromagnetic interference and prevent electric shock.
3. Product Appearance and Components
The EPever EPIPDB-COM solar controller features a compact design with clear indicators and connection points. An optional remote meter (MT-1) and remote temperature sensor can be connected for extended functionality.
3.1. Component Identification
| Icon/Label | Function |
|---|---|
| Battery 1 Icon | Connect with battery #1. |
| Battery 2 Icon | Connect with battery #2. |
| PV Array Icon | Connect with the PV array (solar panels). |
| Remote Temp. Sensor (Optional) | Remotely measures the battery temperature to regulate the battery voltage for optimal charging. |
| Local Temp. Sensor | Measures ambient temperature. If a remote temp. sensor is connected, the controller will use its data. |
| For Battery 1 LED | Indicates battery #1 charging status and error. |
| For Battery 2 LED | Indicates battery #2 charging status and error. |
| Remote Meter Connection (RJ45) | Connects with a remote meter (e.g., MT-1) for monitoring and configuration. |
4. Setup and Installation
Follow these steps for proper installation. Ensure all connections are secure before applying power.
- Connect Battery #1: Connect the positive and negative terminals of Battery #1 to the corresponding terminals on the controller.
- Connect Battery #2: Connect the positive and negative terminals of Battery #2 to the corresponding terminals on the controller.
- Connect PV Array: Connect the positive and negative terminals of your solar PV array to the corresponding terminals on the controller.
- Connect Remote Temperature Sensor (Optional): If using, connect the remote temperature sensor to its designated port. The controller will automatically use data from the remote sensor if connected.
- Connect Remote Meter (Optional): If using, connect the MT-1 remote meter to the RJ45 remote meter connection port.
- Grounding: Ensure the grounding terminal on the controller shell is properly grounded.
Note: Connect components in the order 1-6 as indicated in the product diagram (Battery 1, Battery 2, PV Array, Remote Temp Sensor, Remote Meter Connection, Grounding). Always disconnect in reverse order.
5. Mode Setting
The controller allows configuration of battery type, charging priority, and charging frequency using the three LED indicators and a setting button. The LEDs flash to indicate different specifications.
5.1. Battery Type Setting (1st LED)
The 1st LED indicates the battery type. Choose the appropriate number for your battery type.
| 1st LED Indicator | Battery Type |
|---|---|
| 1 | Sealed battery |
| 2 | Gel battery |
| 3 | Flooded battery |
5.2. Charging Priority Setting (2nd LED)
The 2nd LED sets the charging percentage for Battery #1. The controller automatically calculates the remaining percentage for Battery #2.
| 2nd LED Indicator | Battery #1 Charging Percentage | Battery #2 Charging Percentage |
|---|---|---|
| 0 | 0% | 100% |
| 1 | 10% | 90% |
| 2 | 20% | 80% |
| 3 | 30% | 70% |
| 4 | 40% | 60% |
| 5 | 50% | 50% |
| 6 | 60% | 40% |
| 7 | 70% | 30% |
| 8 | 80% | 20% |
| 9 (pre-set) | 90% | 10% |
Note: During normal charging, the controller charges batteries according to the set percentage. If one battery is fully charged (e.g., Battery #1), more charge current will be diverted to the other battery (Battery #2). The controller automatically reverts to the set percentage when Battery #1 voltage is low. If only one battery is detected, all charging current will be directed to that battery.
5.3. PWM Charging Frequency Setting (3rd LED)
The 3rd LED sets the PWM charging frequency.
| 3rd LED Indicator | PWM Charging Frequency |
|---|---|
| 0 | 25Hz (pre-set) |
| 1 | 50Hz |
| 2 | 100Hz |
To save settings: After selecting the desired number for any LED setting, press the setting button for 5 seconds until the number flashes. Release the button, and the chosen number will be saved.
6. Troubleshooting
Refer to the table below for common issues and their solutions based on LED status indicators.
| No. | LED Status | Troubleshooting |
|---|---|---|
| 1 | LED blinking | Short circuit. Check whether the PV and battery connection is correct. |
| 2 | LED slowly flashing | Battery fully charged. |
| 3 | LED ON | In charging. |
| 4 | LED frequent flashing | No charging or any battery is detected. |
| 5 | LED OFF | No battery or system over voltage. |
7. Technical Specifications
| Parameter | EPIPDB-COM-10 | EPIPDB-COM-20 |
|---|---|---|
| Nominal system voltage | 12/24VDC Auto | |
| Rated charge current | 10A | 20A |
| Battery Type | Sealed; Gel; Flooded | |
| Equalize charging voltage | Sealed: 14.6V; Gel: No; Flooded: 14.8V | |
| Boost charging voltage | Sealed: 14.4V; Gel: 14.2V; Flooded: 14.6V | |
| Float charging voltage | Sealed/Gel/Flooded: 13.8V | |
| Maximum solar voltage | 30V (12V System); 55V (24V System) | |
| Battery voltage range | 8 ~ 15V | |
| Boost time | 120 minutes | |
| Self-consumption | 4mA at night; 10mA at charging | |
| Communication port | 8-PIN RJ-45 | |
| Temp. compensation | -5mV/°C/2V | |
| Terminals | 4mm² | |
| Environment temperature | -35°C ~ +55°C | |
| Net weight | 250g | |
Note: The above parameters are measured in a 12V system. Double the values for a 24V system where applicable (e.g., Maximum solar voltage, battery voltage range).
7.1. Mechanical Drawing
8. User Tips
- This controller is suitable for managing power for various loads, such as movers and lighting, in addition to charging batteries.
- Ensure your solar panel's voltage and current output are compatible with the controller's specifications (e.g., a 20A controller can handle a 500W 24V panel, but a 500W 12V panel would likely exceed its current rating and is not recommended).
- The controller is designed to charge two AGM batteries of the same type, and you can set the charging priority between them.
- The charging voltages (Equalize, Boost, Float) are pre-set based on the selected battery type and are not user-programmable.
9. Warranty and Support
This product is manufactured by HUIZHOU EPEVER TECHNOLOGY CO., LTD.
For detailed warranty information and further support, please refer to the official product documentation. A comprehensive user manual in PDF format is available for download: EPever EPIPDB-COM User Manual (PDF).