Important Safety Instructions
Please reserve this manual for future review. This manual contains all the safety, installation, and operation instructions for the DuoRacer series MPPT Dual Battery Solar Charge Controller (referred to as the controller in the next contents).
- Read all the instructions and warnings carefully before installation.
- No user-serviceable components exist inside the controller. Do NOT disassemble or attempt to repair the controller.
- Avoid direct sunlight and high temperature, and do NOT install the controller at locations where water can get in.
- Install the controller in well-ventilated places; the controller's heat sink may become very hot during the system operation.
- Do not install the controller in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
- Appropriated external fast-acting fuses or breakers are suggested.
- Please cut off all PV array connections, and disconnect the fast-acting fuses or breakers close to the battery before the controller installation and adjustment.
- Power connections must remain tight to avoid excessive overheating from the loose connection.
1. General Information
1.1 Overview
The DuoRacer MPPT charge controller is designed for charging two batteries simultaneously in a solar system: a main battery (BATT1) and a starter battery (BATT2). It supports various main battery types including Sealed, Gel, Flooded, LiFePO4, and Li-NiCoMn, making it suitable for RVs, campers, and boats. The device automatically recognizes the starter battery (BATT2) system voltage and charges it when conditions are met.
This controller utilizes an advanced MPPT control algorithm to minimize power loss and quickly track the maximum power point (MPP) of the PV array, maximizing solar energy utilization. Energy efficiency in MPPT solar systems is increased by 20-30% compared to PWM charging methods.
When inactive for extended periods or when charging conditions are not met, the controller enters a low-power mode to reduce self-consumption and extend battery life. System parameters can be viewed and set via LED/LCD or the optional MT11 remote meter.
An integrated AES control signal for car refrigerators allows the controller to supply surplus solar power to the refrigerator, preventing energy waste. The controller boasts an IP33 protection level, ensuring it is waterproof and dustproof. Multiple protection features, including battery overcharge, over-discharge, and reverse connection protection for both PV and battery, ensure the solar system's safety, stability, and longevity.
Features:
- Maximum Power Point Tracking (MPPT) technology with ultra-fast tracking speed and ≥99.5% tracking efficiency.
- Advanced MPPT control algorithm to minimize MPP loss rate and time.
- Wider range of MPP operation voltage to improve PV module utilization.
- Auto-control function for charging power and current limitation (BATT1).
- High-quality components (ST, TI, Infineon) for extended product life.
- Digital circuit control of adaptive three-stage charging mode to enhance BATT1 life.
- BATT1 type can be set via LED/LCD.
- Low-power mode activation when no manual operation and PV < 5V.
- 100% charging and discharging within the operational environmental temperature range.
- Optional LED and LCD units.
- AES control signal for car refrigerators to avoid energy waste.
- Standard Modbus protocol and RS485 (5V/200mA) communication port for expanded application.
Note:
- Main battery (BATT1) is for household loads in off-grid systems, supporting Sealed, Gel, Flooded, LiFePO4, and Li-NiCoMn batteries. The controller does NOT automatically identify the system voltage for BATT1.
- Starter battery (BATT2), built in the vehicle, is for powering systems like RVs and boats. It ONLY supports lead-acid batteries, and the controller automatically identifies its system voltage.
- CAUTION: The BATT1 and BATT2 must be at the same voltage level.
1.2 Appearance and Components
The Epever Duo Racer MPPT Solar Controller is designed for efficient dual battery charging. Below are diagrams illustrating the controller's appearance and its key components.
Key components and ports:
- Mounting hole size Ø5mm
- LCD (Refer to chapter 3 for details)
- Grounding Terminal
- Remote temperature sensor port (The controller charges BATT1 as default (25°C) when not connected or sensor is damaged.)
- PV terminals
- BATT1 terminals
- BATT2 terminals
- RS485 Communication port
- AES (signal) output port
- Terminal protection cover
2. Setup (Installation)
2.1 Attentions
- Do not install the controller in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
- Be very careful when installing the batteries, especially flooded lead-acid batteries. Wear eye protection, and have fresh water to rinse if there is any contact with battery acid.
- Keep the battery away from any metal objects, which may cause a short circuit of the battery.
- Explosive battery gases may come out from the battery during charging, so make sure the ventilation condition is good.
- For outdoor installation, keep out of direct sunshine and rain infiltration.
- Loose connections and corroded wires may produce high heat that can melt wire insulation, burn surrounding materials, or even cause a fire. Ensure tight connections, use cable clamps to secure cables, and prevent them from swaying in mobile applications.
- The controller can work with lead-acid and lithium batteries within its control scope.
- The battery connection may be wired to one battery or a bank of batteries.
- Select system connection cables according to a current density no greater than 5A/mm².
2.2 PV Array Requirements and Wire Size
The controller is compatible with various PV modules. The series number of PV modules should be calculated based on the open-circuit voltage (Voc) and maximum power point voltage (Vmpp) of the MPPT controller. Refer to the specifications section for detailed tables.
The minimum wire size is determined by the PV Isc (short circuit current). Ensure the PV array's Isc does not exceed the controller's maximum PV input current. Wiring and installation must conform to national and local electrical code requirements.
PV Wire Size Guidelines:
| Model | Max. PV input current | Max. PV wire size |
|---|---|---|
| DR1106N-DDB/DDS, DR1206N-DDB/DDS | 10A | 4mm²/12AWG |
| DR2106N-DDB/DDS, DR2206N-DDB/DDS, DR2210N-DDB/DDS | 20A | 6mm²/10AWG |
| DR3106N-DDB/DDS, DR3206N-DDB/DDS, DR3210N-DDB/DDS | 30A | 10mm²/8AWG |
CAUTION:
- When PV modules are connected in series, the open-circuit voltage of the PV array must not exceed 46V (for DR**06N-DDB/DDS) or 92V (for DR**10N-DDB/DDS).
- The wire size is for reference only. For long distances, use larger wires to reduce voltage drop.
- Battery cable size recommendations assume the charge controller is the only device connected to this cable.
2.3 Mounting
WARNING:
- Risk of explosion. Never install the controller in a sealed enclosure with flooded batteries. Do not install in a confined area where battery gas can accumulate.
- Risk of electric shock. Disconnect the breaker before wiring because the PV array may generate a high open-circuit voltage.
CAUTION:
- The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
Installation steps:
- Determine the installation location and heat-dissipation space: The controller shall be installed with sufficient airflow through its radiators. Minimum clearance is 150mm from upper and lower edges for natural thermal convection. Ensure reliable heat dissipation if installed in an enclosed box.
- Wiring: Connect the system in the order of Starter battery (BATT2) → Main battery (BATT1) → PV array. Disconnect in the reverse order.
CAUTION (Wiring):
- BATT1 and BATT2 must be set at the same voltage level.
- While wiring, do NOT connect the breaker or fast-acting fuse. Ensure correct electrode polarity.
- A fast-acting fuse (1.25 to 2 times the controller's rated current) must be installed on the battery side, no more than 150mm from the battery.
- If an inverter is connected, connect it directly to the battery.
- Grounding: The DR N series is a common-negative controller. All negative terminals of the PV array and battery can be grounded simultaneously, or any one of the negatives can be grounded. The grounding terminal on the controller's shell MUST be grounded to shield electromagnetic interference and prevent electric shock.
CAUTION (Grounding):
- A common-negative controller is recommended for common-negative systems (e.g., motorhomes). However, the controller may be damaged if some common-negative equipment is used and its positive electrode is grounded in the common-negative system.
- Connect the remote temperature sensor cable: Connect the remote temperature sensor cable to port 4 and place the other end close to BATT1.
CAUTION (Temperature Sensor):
- If the remote temperature sensor is not connected, the default temperature for battery charging or discharging is 25°C without temperature compensation.
- Connect the remote meter MT11 and AES signal of the refrigerator: The remote meter operations refer to the MT11 user manual. The controller provides one AES signal control.
AES Adapter (Optional): The AES-ADP adapter converts the 5V-AES signal of the solar controller into a 12V-AES signal for the refrigerator. An AES-ADP adapter is necessary when DR1206/2206/3206/2210/3210N-DDB/DDS connects to the refrigerator.
AES-ADP Main Parameters:
- Applicable Models: DR1206/2206/3206/2210/3210N-DDB/DDS
- Input Voltage: 8.5V-35V
- Output Voltage: 12V/200mA
- Self-consumption: 1mA@12V; 1.5mA@24V
- Environment temperature: -30°C ~ +60°C
- Features: Supports output short-circuit, BATT1 input terminal reversed polarity, and AES signal reversed connection.
- Power on the controller:
- Firstly, turn on the BATT2 safety switch and check the BATT2 charging indicator status.
- Then, turn on the BATT1 safety switch and check the BATT1 charging indicator status.
- Lastly, connect the PV array circuit breaker.
CAUTION (Power On):
- If the controller is not operating properly or the battery indicator shows an abnormality, refer to the Troubleshooting section.
3. Operating Instructions
3.1 Battery Charging Stages (BATT1)
The controller employs a three-stage battery charging algorithm: Bulk Charging, Constant Charging (Equalize/Boost), and Float Charging. This method extends battery lifespan.
- Bulk Charging: The controller delivers maximum current (MPPT Charging) until the battery voltage reaches the constant voltage set point.
- Constant Charging: Once the constant voltage set point is reached, the controller enters constant charging mode. MPPT charging stops, and the current gradually drops. This stage has two phases:
- Boost Charging: Default duration is 2 hours. The system switches to float charging when the duration equals the set value.
- Equalize Charging: Starts on the 28th of each month. This increases battery voltage above the standard complement voltage to stir electrolytes and balance battery voltage.
WARNING (Equalize Charging):
- Explosive Risk! Equalizing flooded batteries produces explosive gases; ensure good ventilation.
- Equipment damage! Equalization may increase battery voltage, potentially damaging sensitive DC loads. Verify load's allowable input voltages.
- Over-charging or excessive gas precipitation can damage battery plates. Review battery requirements carefully.
- Float Charging: After constant charging, the controller reduces battery voltage to the float charging preset voltage by reducing current. The battery is weakly charged to maintain a fully charged state. If loads exceed solar array power, the controller will not maintain float charging. If battery voltage drops below the boost voltage reconnect voltage, the system exits float charging and re-enters bulk charging.
3.2 Starter Battery (BATT2) Charging
The controller trickle charges BATT2 at 1A constant current. Charging stops when BATT2 reaches its "Full voltage."
Voltage Parameters:
| Item | Default | Modify range |
|---|---|---|
| Full voltage | 13.8V/12V; 27.6V/24V | 9~17V (24V×2) |
| Charge return voltage | 13V/12V; 26V/24V | 9~17V (24V×2) |
CAUTION:
- Follow the logic: Full Voltage > Return Voltage when modifying the voltage point.
- BATT2 ONLY supports lead-acid battery types. Connect BATT1 first before BATT2 charging.
Start Charging Conditions:
- BATT2 starts charging when BATT1 reaches float charging stage AND BATT2 voltage is lower than "Charging Return Voltage."
- BATT2 starts charging when total charging current is higher than 3A AND BATT2 voltage is lower than "Charging Return Voltage."
Stop Charging Conditions:
- BATT2 stops charging when PV voltage is no higher than 2V of BATT1.
- BATT2 stops charging when BATT1 is not in float charging stage AND total charging current for battery is less than 2.5A.
- BATT2 stops charging when BATT2 reaches "Full Voltage."
CAUTION:
- After BATT2 charging is turned off, it will be recharged only when the start charging conditions are satisfied.
3.3 AES Signal Port
The AES signal port is designed for car refrigerators supporting the AES signal and is built into a power switching device.
Working Principle:
- The AES signal turns on after BATT1 voltage reaches Boost Charging Voltage or Equalize Charging Voltage for 5 minutes.
- The controller checks BATT1 charging stage every 5 minutes. The AES signal control turns off if BATT1 is not in the charging stage five times.
For DR1106/2106/3106N-DDB/DDS models: AES port (outputs 12V/200mA) and RS485 port (outputs 5V/200mA) are independent. The 12V output voltage is the battery voltage. Connect the refrigerator directly.
For DR1206/2206/3206/2210/3210N-DDB/DDS models: The AES port and RS485 port share 5VDC/Max. 200mA power. Connect accessories (AES-ADP adapter) when connecting the refrigerator.
3.4 Display Units (DDB & DDS)
The controller features either a DuoRacer Display Basic (DDB) or DuoRacer Display Standard (DDS) unit for monitoring and setting parameters.
DuoRacer Display Basic (DDB) - Status Indicator
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| MPP | Green | OFF | No charging |
| Green | Slowly flashing (1Hz) | Charging, in Boost or Equalize charging stage | |
| Green | On solid | Full, in Float charging stage | |
| TEMP | Red | OFF | BATT1 Temperature normal |
| Red | Fast flashing (4Hz) | BATT1 over-temperature or BATT1 low temperature | |
| STATE | Green | On solid | Connect to BATT1 and in charging |
| Green | Slowly flashing (0.2Hz) | Connect to BATT1 and no charging | |
| LOW | Green | OFF | Not connect BATT1 |
| Red | On solid | BATT1 over-discharged/Low voltage | |
| Red | OFF | BATT1 low voltage reconnect | |
| AES Signal | Green | On solid | AES signal is ON |
| Green | OFF | AES signal is OFF | |
| BATT2 STATE | Green | On solid | Connect to BATT2 and in charging |
| Green | Slowly flashing (1Hz) | Connect to BATT2 and no charging | |
| Green | OFF | Not connect BATT2 |
The controller cannot identify the system voltage when the battery type is a lithium battery.
Setting Battery Type (DDB):
- Press and hold the button for 3 seconds; the green BATT SEL MODE indicator will be solid. Enter the battery setting mode.
- Press the button to select the battery type.
- Wait for 5 seconds until the setting indicator turns off. The battery type is set successfully.
CAUTION:
- The battery control voltage parameters cannot be modified when the battery is set as the default battery type. To modify, select "User" battery type.
- Control parameters can only be set via PC software or mobile APP under the "User" battery type.
DuoRacer Display Standard (DDS) - Charging Indicator
The display screen can be viewed clearly when the angle between the end-users horizontal sight and the display screen is within 90°. If the angle exceeds 90°, the information cannot be viewed clearly.
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| PV Icon | Green | On solid | PV charges the battery with a low current |
| Green | OFF | 1. No sunlight 2. Connection error 3. Low PV voltage | |
| Green | Slowly flashing (1Hz) | Normal charging | |
| Green | Fast flashing (4Hz) | PV overvoltage |
The DDS unit also provides detailed operation interface icons for BATT1/BATT2 capacity, PV array status, charging icons, temperature parameters, AES signal, battery type, and voltage limits. It also displays fault indications for overvoltage, over-discharge, and over-temperature.
4. Maintenance
The following inspections and maintenance tasks are recommended at least twice yearly for best controller performance:
- Ensure the controller is firmly installed in a clean and dry ambient.
- Ensure no block on airflow around the controller. Clear any dirt and fragments on the radiator.
- Check all naked wires to ensure insulation is not damaged by solarization, frictional wear, dryness, insects, or rats. Repair or replace wires if necessary.
- Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
- Check and confirm that LED or LCD is consistent with the required. Pay attention to any troubleshooting or error indication. Take necessary corrective action.
- Confirm that all system components are grounded tightly and correctly.
- Confirm that all terminals have no corrosion, insulation damage, high temperature, or burnt/discolored sign. Tighten terminal screws to the suggested torque.
- Clear dirt, nesting insects, and corrosion in time.
- Check and confirm that the lightning arrester is in good condition. Replace a new one in time to avoid damaging the controller and other equipment.
WARNING:
- Risk of electric shock! Ensure all power is turned off before performing maintenance operations and follow corresponding inspections.
5. Troubleshooting
| Faults phenomenon | Possible reasons | Troubleshooting |
|---|---|---|
| Charging LED indicator off during daytime when sunshine falls on PV modules properly | PV array disconnection | Confirm that PV wire connections are correct and tight. |
| The wire connection is correct, and the controller is not working. | Battery voltage is lower than 8.5V | Please check the battery voltage – at least 8.5V to activate the controller. |
| DDS: Red fast flashing; Battery level shows full, battery frame blink, fault icon blink | BATT1 overvoltage | Check if the battery voltage is higher than OVD (over-voltage disconnect voltage), and disconnect the PV. |
| DDB: red on solid; DDS: Battery level shows empty, battery frame blink, fault icon blink | BATT1 over-discharged | When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover. |
| DDB: Red fast flashing; DDS: Battery level shows current capacity, battery frame blink, fault icon blink, the temperature icon blink, the temperature value blink, the temperature unit blink. | BATT1 Overheating | The controller will automatically turn the system off. When the temperature declines to be below 55 °C, the controller will resume. |
| DDS: Red Fast flashing and Green fast flashing (System voltage error) | BATT1 System voltage error | 1. Check whether the battery voltage matches the controller's working voltage. 2. Please change to a suitable battery or reset the working voltage. |
| System voltage alarms when using Lead-acid battery for BATT1. Over-discharge alarms when BATT1 is set as 24V but actual voltage is 12V. Over-voltage alarms when BATT1 is set as 12V but actual voltage is 24V. | Incorrect wiring – connect BATT1 first and then BATT2 | 1. Disconnect the system, and reconnect BATT1 first, then BATT2. 2. BATT1 voltage should be the same as the controller's voltage level. |
6. Specifications
Electrical Parameters
| Item | DR1106N-DDB/DDS | DR2106N-DDB/DDS | DR3106N-DDB/DDS | DR1206N-DDB/DDS | DR2206N-DDB/DDS | DR3206N-DDB/DDS | DR2210N-DDB/DDS | DR3210N-DDB/DDS |
|---|---|---|---|---|---|---|---|---|
| BATT1 rated voltage | 12VDC | 12/24VDC | ||||||
| BATT2 rated voltage | 12VDC | 12/24VDC Auto | ||||||
| BATT1 Rated Charge Current | 10A | 20A | 30A | 10A | 20A | 30A | 20A | 30A |
| BATT2 Rated Charge Current | 1A | |||||||
| Battery Input Voltage Range | 8.5~16V | 8.5~32V | ||||||
| Max. PV Open Circuit Voltage | 60V (46V) | 100V (92V) | ||||||
| MPP Voltage Range | (Battery Voltage+2V)~36V | (Battery Voltage+2V)~72V | ||||||
| Rated Charge Power | 130W/12V | 260W/12V | 390W/12V | 130W/12V, 260W/24V | 260W/12V, 520W/24V | 390W/12V, 780W/24V | 260W/12V, 520W/24V | 390W/12V, 780W/24V |
| Max. conversion efficiency | 96.3% | 96.9% | 97.4% | 97.4% | 97.5% | 98% | 97.5% | 98% |
| Full load efficiency | 95.5% | 94.6% | 94.2% | 97% | 96% | 96% | 96% | 96% |
Environmental Parameters
| Item | DR1106/2106/3106/1206/2206/2210N-DDB/DDS | DR3206/3210N-DDB/DDS |
|---|---|---|
| Environment temperature (100% input and output) | -20°C ~ +50°C (DDS) -30°C ~ +50°C (DDB) | -20°C ~ +45°C (DDS) -30°C ~ +45°C (DDB) |
| Storage temperature | -30°C ~ +80°C | |
| Relative humidity | ≤95%, N.C | |
| Enclosure | IP33 (3-protection against solid objects >2.5mm; 3-protected against sprays to 60° from vertical) | |
| Pollution degree | PD2 | |
Mechanical Parameters
| Item | DR1106/1206N-DDB/DDS | DR2106/2206/2210N-DDB/DDS | DR3106/3206/3210N-DDB/DDS |
|---|---|---|---|
| Dimension (L x W x H) | 227.2x143x58.1mm | 243.7x158x63mm | 247.2x165x68.5mm |
| Mounting size (L x W) | 160x134mm | 180x149mm | 180x156mm |
| Mounting hole size | Ø5mm | ||
| Terminal (BATT1) | 12AWG/4mm² | 6AWG/16mm² | 6AWG/16mm² |
| Terminal (BATT2) | 12AWG/4mm² | 12AWG/4mm² | 12AWG/4mm² |
| Recommended cable size (BATT1) | 12AWG/4mm² | 10AWG/6mm² | 8AWG/10mm² |
| Recommended cable size (BATT2) | 12AWG/4mm² | 12AWG/4mm² | 12AWG/4mm² |
| Weight | 0.8kg | 1.1kg | 1.4kg |
Dimension Diagrams
Detailed dimension diagrams for other models (DR2106/2206/2210N-DDB/DDS and DR3106/3206/3210N-DDB/DDS) are available in the full PDF user manual.
7. User Tips
- Verify Amperage: Always double-check the maximum amperage rating of your specific controller model (e.g., 20A or 30A) to ensure it matches your solar panel and battery bank requirements. This is crucial for optimal performance and safety.
- Battery Voltage Consistency: Ensure that both your main battery (BATT1) and starter battery (BATT2) are at the same nominal voltage level (e.g., both 12V or both 24V) for proper operation.
- Ventilation is Key: Proper airflow around the controller is essential, especially during high-power operation, to prevent overheating and ensure longevity.
8. Warranty and Support
For detailed warranty information, technical support, or further inquiries, please refer to the official Epever website or contact your authorized dealer.
A comprehensive user manual in PDF format is available for download: Epever Duo Racer MPPT Solar Controller User Manual (PDF).
Any changes to the product specifications or features may occur without prior notice. Please refer to the latest documentation for the most up-to-date information.