1. Introduction
This manual provides essential information for the installation, operation, and troubleshooting of your EPEVER EPIPDB-COM PWM Dual Battery Solar Controller. This controller is designed to manage solar charging for two independent battery banks, ensuring efficient power distribution and protection.
2. Safety Precautions
WARNING:
- Do not install the controller in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
- Using a common-negative controller for common-negative systems, such as an RV system, is recommended. The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in the common-negative system.
3. Product Overview
The EPIPDB-COM controller features a compact design with clear indicators and connection points for easy setup and monitoring. It includes a remote temperature sensor input and a remote meter connection for enhanced functionality.
3.1. Key Features
- PWM charging technology.
- Dual battery charging capability.
- Automatic 12V/24V system voltage detection.
- Comprehensive electronic protection functions.
- Optional remote temperature sensor and remote meter connection.
3.2. Protection Features
The controller incorporates multiple protection mechanisms to ensure safe and reliable operation:
- Over charging protection
- Short-circuit protection
- Reverse polarity protection
- Reverse current to PV protection
4. Installation and Wiring
Before installation, please watch the unboxing video to familiarize yourself with the product and its components.
4.1. Connection Sequence
Connect the components in the following order (1-6 as indicated in the diagram):
| Icon | Function |
|---|---|
| Connect with battery #1. | |
| Connect with battery #2. | |
| Connect with the PV array. | |
| Remote temp. sensor (Optional) | Remotely measure the battery temperature to regulate the battery voltage. |
| Remote meter connection | Connect with a remote meter. |
Grounding: EPIPDB-COM series are common-negative controllers. Negative terminals of the PV array and batteries can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on the controller shell must be grounded to shield electromagnetic interference and avoid electric shock.
5. Operation and Mode Setting
The controller uses three LEDs to indicate different specifications. To set a parameter, press the button for 5 seconds until the number flashes. Then, choose the desired number and release the button to save the setting.
5.1. Battery Type Setting (1st LED)
| 1st LED | Battery Type |
|---|---|
| 1 | Sealed battery |
| 2 | Gel battery |
| 3 | Flooded battery |
5.2. Charging Priority Setting (2nd LED)
Set the charging percentage for battery #1. The controller will automatically calculate the remaining percentage for battery #2.
| 2nd LED | Battery #1 Charging Percentage | Battery #2 Charging Percentage |
|---|---|---|
| 0 | 0% | 100% |
| 1 | 10% | 90% |
| 2 | 20% | 80% |
| 3 | 30% | 70% |
| 4 | 40% | 60% |
| 5 | 50% | 50% |
| 6 | 60% | 40% |
| 7 | 70% | 30% |
| 8 | 80% | 20% |
| 9 | 90% (pre-set) | 10% |
Note: During normal charging, the controller charges batteries per the set percentage. If one battery is fully charged, more current will be diverted to the other battery. The controller automatically returns to the setting percentage when battery #1 is low voltage. If only one battery is detected, all charging current will go to that battery.
5.3. Charging Frequency Setting (3rd LED)
| 3rd LED | PWM Charging Frequency |
|---|---|
| 0 | 25Hz (pre-set) |
| 1 | 50Hz |
| 2 | 100Hz |
6. Troubleshooting
Refer to the table below for common issues indicated by the LED status and their corresponding solutions.
| No. | LED Status | Troubleshooting |
|---|---|---|
| 1 | LED blinking | Short circuit. Please check whether the PV and battery connection is correct. |
| 2 | LED slowly flashing | Fully charged |
| 3 | LED ON | In charging |
| 4 | LED frequent flashing | No charging or any battery is detected. |
| 5 | LED OFF | No battery or system over voltage. |
7. Technical Specifications
| Parameter | EPIPDB-COM-10 | EPIPDB-COM-20 |
|---|---|---|
| Nominal system voltage | 12/24VDC Auto | |
| Rated charge current | 10A | 20A |
| Battery Type | Sealed; Gel; Flooded | |
| Equalize charging voltage | Sealed: 14.6V; Gel: No; Flooded: 14.8V | |
| Boost charging voltage | Sealed: 14.4V; Gel: 14.2V; Flooded: 14.6V | |
| Float charging voltage | Sealed/Gel/Flooded: 13.8V | |
| Maximum solar voltage | 30V (12V System); 55V (24V System) | |
| Battery voltage range | 8 ~ 15V | |
| Boost time | 120 minutes | |
| Self-consumption | 4mA at night; 10mA at charging | |
| Communication port | 8-PIN RJ-45 | |
| Temp. compensation | -5mV/°C/2V | |
| Terminals | 4mm² | |
| Environment temperature | -35°C ~ +55°C | |
| Net weight | 250g | |
Note: The above parameters are measured for a 12V system. For a 24V system, please double the values where applicable.
8. Mechanical Drawing
The following diagram provides the mechanical dimensions of the EPIPDB-COM controller.
9. User Tips
- Ensure you select the correct current rating (10A or 20A) for your specific solar and battery setup to prevent overloading and ensure optimal performance.
- Regularly check all wiring connections for tightness and corrosion to maintain efficient power transfer and prevent potential issues.
10. Warranty and Support
For detailed warranty information, technical support, or further inquiries, please refer to the official EPEVER documentation or contact your vendor. A comprehensive user manual in PDF format is available for download: EPIPDB-COM User Manual (PDF).
Manufactured by HUIZHOU EPEVER TECHNOLOGY CO., LTD.