1. Safety Information

Please read all instructions carefully before installation and operation to ensure safe and efficient use of the controller.

  • Do not disassemble or attempt to repair the controller. Unauthorized modifications can void the warranty and pose safety risks.
  • Install an external fast-acting fuse or breaker as required for protection.
  • Disconnect the solar module and fast-acting fuses/breakers near the battery before installing or moving the controller to prevent electrical hazards.
  • Ensure all power connections remain tight to avoid excessive heating from loose connections, which can lead to fire or damage.
  • Only charge batteries that comply with the controller's parameters (Sealed, Gel, Flooded).
  • The battery connection may be a single battery or a bank of batteries.
  • Be aware of the risk of electric shock. The PV array and load can produce high voltages when the controller is operating.
  • Do not install this product in humid, salt spray, corrosive, greasy, flammable, explosive, or dusty environments.

2. Product Overview

The EPEVER LandStar E/EU series is a Pulse Width Modulation (PWM) solar charge controller designed for efficient and cost-effective solar power management. It incorporates advanced digital techniques for reliable performance.

EPEVER LS-EU Series PWM Solar Charge Controller front view
Front view of the EPEVER LS-EU Series PWM Solar Charge Controller, highlighting its compact design and USB port.

Key Features:

  • 3-Stage Intelligent PWM Charging: Features Bulk, Boost/Equalize, and Float charging stages to optimize battery life.
  • Battery Type Support: Compatible with Sealed, Gel, and Flooded batteries.
  • Battery Status LED Indicator: Provides clear visual indication of battery status.
  • Battery Temperature Compensation: Automatically adjusts charging parameters based on temperature for optimal performance.
  • USB Power Supply: Includes a USB port (5V Max. 1.2A) for charging electronic equipment (LS-EU series only).
  • User-Friendly Settings: Battery type and load output can be easily set via a single button.
  • Extensive Electronic Protection: Built-in protections against various electrical faults.
Diagram showing optional battery types (Sealed, Gel, Flooded) and USB output port
The controller supports Sealed, Gel, and Flooded battery types and features a convenient USB output port.
Diagram highlighting extensive electronic protection and LED indicators for battery status
The controller offers extensive electronic protection and uses LED indicators to show battery status.
Diagram illustrating battery temperature compensation function and industrial quality design
Features include battery temperature compensation and an industrial quality standard design.

3. Setup (Wiring)

Proper wiring is crucial for the safe and correct operation of the solar charge controller. Follow these steps carefully:

  1. Connect the Battery: First, connect the battery to the controller's battery terminals. Ensure correct polarity (+ to + and - to -).
  2. Connect the Load: Next, connect the DC load to the controller's load terminals.
  3. Connect the PV Array: Finally, connect the solar PV array to the controller's PV terminals.

Important Notes:

  • Always connect and disconnect in the specified order: Battery → Load → PV array for connection, and PV array → Load → Battery for disconnection.
  • Do not connect the circuit breaker or fast-acting fuse while wiring the controller.
  • Ensure that the leads of the "+" and "-" poles are connected correctly.
  • A fast-acting fuse with a current rating of 1.25 to 2 times the controller's rated current must be installed on the battery side, with a distance from the battery not greater than 150 mm.
  • WARNING: The controller has no PV reverse connection protection; please connect it correctly to prevent damage.
Solar Charge Controller Wiring Diagram showing connections for battery, load, and PV array
Wiring diagram for the solar charge controller, illustrating connections for battery, load, and PV array with recommended breakers and fuse.
Detailed product feature diagram with numbered components and their labels
Detailed diagram of the controller's components: 1. PV Terminals, 2. Battery Terminals, 3. Load Terminals, 4. USB output interface (LS EU series only), 5. Mounting Hole, 6. Load Switch Button, 7. Battery status LED indicator, 8. Load status LED indicator, 9. Charging status LED indicator.

4. Operating Instructions

4.1. LED Indicators

The controller uses various LED indicators to display its operational status and battery situation.

Charging and Load Status Indicator

IndicatorColorStatusInstruction
Charging status LED indicatorGreenOn SolidIn Charging
OFFNo Charging
Fast FlashingBattery Over Voltage
Load status LED indicatorGreenOn SolidLoad ON
OFFLoad OFF
Slowly FlashingOverload
Fast FlashingLoad short circuit

Battery Status Indicator

LED1LED2LED3LED4Battery Status
Slowly FlashingXXXUnder voltage
Fast FlashingXXXOver-discharge
Battery LED indicator status during voltage is up
XOXX12.8V < Ubat < 13.4V
OXOX13.4V < Ubat < 14.1V
OOOX14.1V < Ubat
Battery LED indicator status during voltage is down
XOOX12.8V < Ubat < 13.4V
XXOX12.4V < Ubat < 12.8V
XOXXUbat < 12.4V

NOTE: The above voltage values are measured in a 12V system at 25°C; please double the values for a 24V system. "O" states LED indicator on; "X" states LED indicator off.

4.2. Load ON/OFF Setting

Press the button on the controller to control the load output. This allows you to manually turn the load ON or OFF when the controller is powered on.

4.3. Battery Type Setting

The controller supports different battery types. Follow these steps to set the correct battery type:

  1. Step 1: Enter the setting mode by pressing and holding the button for 5 seconds until the battery status LEDs begin flashing.
  2. Step 2: While the LEDs are flashing, press the button repeatedly to cycle through and select the desired battery type (Sealed, Gel, or Flooded).
  3. Step 3: The selected mode will be saved automatically if no further operation is performed for 5 seconds. The LEDs will stop flashing, indicating the setting is complete.

Battery Type Indicator

LED1LED2LED3Battery Type
XXXSealed (Default)
OOXGel
OXOFlooded

NOTE: "O" states LED indicator on; "X" states LED indicator off.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your solar charge controller. Perform the following checks periodically:

  • Inspect Connections: Regularly check all wiring connections (PV, battery, load) to ensure they are tight and free from corrosion. Loose connections can cause overheating and damage.
  • Clean the Controller: Keep the controller clean and free from dust and debris. Use a dry cloth to wipe the surface. Ensure ventilation openings are not blocked.
  • Check for Damage: Visually inspect the controller for any signs of physical damage, such as cracks, discoloration, or loose parts.
  • Monitor Performance: Observe the LED indicators and system behavior to ensure normal operation. Any unusual behavior should be investigated.
  • Battery Health: Periodically check the battery's voltage and overall health. Ensure the battery type setting on the controller matches your battery.

For more detailed maintenance procedures, please refer to the complete user manual available as a PDF: EPEVER LS-EU Series User Manual (PDF).

6. Troubleshooting

This section provides solutions for common issues encountered with the solar charge controller.

Protection Features:

  • Battery Over Voltage Protection: When the battery voltage reaches the Over Voltage Disconnect Voltage (OVD), the controller automatically stops charging to prevent overcharging.
  • Battery Over Discharge Protection: If the battery voltage drops to the Low Voltage Disconnect Voltage (LVD), the controller stops discharging the battery to prevent over-discharge.
  • Overload Protection: If the load current exceeds 1.25 times the rated current, the load will be switched off after a delay. Reduce the load appliance and press the button or restart the controller.
  • Load Short Circuit Protection: If a load short circuit (current exceeds 2-3 times the rated current) occurs, the load will be switched off. Clear the short circuit fault, then press the button or restart the controller.
  • High Voltage Transients Protection: The controller is protected against small high voltage transients. In lightning-prone areas, an external lightning arrester is recommended.

Common Faults and Solutions:

FaultsPossible ReasonsTroubleshooting
The charging LED turns off during the daytime when sunshine falls on PV modules properly.PV array disconnectionConfirm that PV and battery wire connections are correct and tight.
No LED indicatorBattery voltage may be less than 8VMeasure battery voltage with a multi-meter. A minimum of 8V is required to start the controller.
Charging LED fast flashes.Battery over voltageCheck if the battery voltage is higher than the OVD, and disconnect the PV array.
Load LED1 fast flashes.Battery over-dischargedThe load will recover when the battery voltage is restored to or above the LVR (low voltage reconnect voltage).
Load LED flashes slowly.Overload1. Reduce the number of electric equipment connected. 2. Press the button or restart the controller.
Load LED fast flashes.Load short circuit1. Check carefully load connections and clear the fault. 2. Press the button or restart the controller.

Note: When the load current exceeds 1.25 times, 1.5 times, and 2 times the rated value, the controller can automatically turn off loads after 60s, 5s, and 1s, respectively.

7. Specifications

The following tables detail the technical specifications and battery voltage control parameters for the EPEVER LS-EU Series PWM Solar Charge Controller.

Technical Parameters

ItemLS0512ELS1012ELS1024ELS2024ELS0512EULS1012EULS1024EULS2024EULS3024EU
Nominal system voltage12VDC12/24VDC Auto12VDC12/24VDC Auto
Rated charge current5A10A10A20A5A10A10A20A30A
Rated discharge current5A10A10A20A5A10A10A20A30A
Battery input voltage range8V~16V8V~32V8V~16V8V~32V
Max. PV open circuit voltage30V50V30V50V
Self-consumption12V≤5mA; 24V≤7mA
Charge Circuit Voltage Drop≤0.21V≤0.13V
Discharge Circuit Voltage Drop≤0.12V≤0.17V
USB input interface5VDC/1.2A (LS-EU series only)
Temperature compensation coefficient-5mV/°C/2V
Environment temperature-35°C ~ +50°C
Humidity≤95%, (N.C.)
EnclosureIP30IP20
GroundingCommon Positive
Dimension (L x W x H)92.8x65x20.2mm101.2x67x21.8mm101.2x67x21.8mm128x85.6x34.8mm109.7x65.5x20.8mm120.3x67x21.8mm120.3x67x21.8mm148x85.6x34.8mm148x106.8x43.7mm
Mounting size84.4mm92.7mm92.7mm118mm100.9mm111.5mm111.5mm138mm138mm
Mounting hole sizeΦ4.5
Terminals14AWG/2.5mm²12AWG/4mm²12AWG/4mm²10AWG/6mm²14AWG/2.5mm²12AWG/4mm²12AWG/4mm²10AWG/6mm²8AWG/10mm²
Net weight0.07kg0.08kg0.08kg0.15kg0.09kg0.10kg0.10kg0.18kg0.29kg

Any changes without prior notice! Version number: V4.2

Battery Voltage Control Parameters (12V System at 25°C)

For 24V systems, please double the voltage values.

Battery TypeSealedGelFlooded
Over Voltage Disconnect Voltage16.0V16.0V16.0V
Charging Limit Voltage15.0V15.0V15.0V
Over Voltage Reconnect Voltage15.0V15.0V15.0V
Equalize Charging Voltage14.6V14.8V
Boost Charging Voltage14.4V14.2V14.6V
Float Charging Voltage13.8V13.8V13.8V
Boost Reconnect Charging Voltage13.2V13.2V13.2V
Low Voltage Reconnect Voltage12.6V12.6V12.6V
Under Voltage Warning Reconnect Voltage12.2V12.2V12.2V
Under Voltage Warning Voltage12.0V12.0V12.0V
Low Voltage Disconnect Voltage11.1V11.1V11.1V
Discharging Limit Voltage10.6V10.6V10.6V
Equalize Duration120 min.120 min.
Boost Duration120 min.120 min.120 min.

8. User Tips

Based on user experiences and common inquiries, here are some helpful tips for using your EPEVER LS-EU Series Solar Charge Controller:

  • Verify Amperage: The LS-EU series controllers are available in different amperage ratings (10A, 20A, 30A). Ensure you have selected the correct model that matches your solar panel and battery bank's current requirements.
  • Check Connections Regularly: A common cause of issues is loose wiring. Periodically inspect all connections to ensure they are secure and free from corrosion.
  • Battery Compatibility: Always confirm that the controller's battery type setting (Sealed, Gel, or Flooded) accurately matches the type of battery you are using for optimal charging and battery longevity.
  • Fuse Protection: Do not skip installing the recommended fast-acting fuse on the battery side. This is a critical safety measure.
  • Environmental Considerations: While the controller is robust, avoid installing it in extreme conditions (very high humidity, direct salt spray, excessive dust) to prolong its lifespan.

9. Warranty and Support

The manufacturer provides a warranty for the EPEVER LS-EU Series Solar Charge Controller under normal operating conditions. Please note the following conditions under which the warranty does not apply:

  • Damage resulting from improper use or installation in an unsuitable environment.
  • Damage caused by PV or load current, voltage, or power exceeding the controller's rated values.
  • Any user disassembly or attempted repair of the controller without explicit permission from the manufacturer.
  • Damage due to natural elements such as lightning, floods, or other acts of nature.
  • Damage incurred during transportation and shipment if not reported upon receipt.

For complete warranty terms, technical support, and service inquiries, please refer to the official EPEVER documentation or contact your vendor. The full user manual is available as a PDF: EPEVER LS-EU Series User Manual (PDF).

© 2024 EPEVER. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.