EPEVER TRC Series

Contents

EPEVER TRC Series MPPT Solar Charge Controller User Manual

Model: TRC Series (TRC3106, TRC5106, TRC1206, TRC2206, TRC3210, TRC4210, TRC4215, TRC4415, TRC5215)

Brand: EPEVER

This manual provides detailed instructions for the installation, operation, and maintenance of your EPEVER TRC Series MPPT Solar Charge Controller. Please read thoroughly before use.

1. Introduction

The EPEVER TRC series solar charge controller utilizes a new-generation MPPT (Maximum Power Point Tracking) control algorithm to significantly improve tracking accuracy and response speed. This advanced algorithm minimizes power loss and enhances DC/DC conversion efficiency across various power bands. The controller is designed to efficiently capture energy from solar panels under diverse sunlight conditions.

A key feature is its support for a no-battery mode, allowing direct load supply when sufficient PV power is available. Its low-power consumption design reduces standby power significantly, extending system standby time. The TRC series offers flexible communication configurations, including three optional interface combinations: 2×RS485, RS485+CAN (RV-C), and RS485+LIN (CI-BUS). It also includes an isolated RS485 interface (note: communication isolation is not supported on models below 60V) and short-circuit protection for enhanced system reliability. Optional 4G/WiFi modules enable remote monitoring, and the communication port can be enabled or disabled as needed.

Features:

  • Low power consumption, lower than 10mA.
  • No battery mode: Direct load supply via controller’s battery port (when PV is sufficient).
  • Max. MPPT tracking efficiency ≥ 99.5%; Max. conversion efficiency: 98.5%.
  • Compatible with LiFePO4, AGM, Gel, Flooded batteries, etc.
  • Stable lithium battery self-activation.
  • Dedicated BMS Port: Charge/discharge control & status display (Optional).
  • Dedicated CAN Port: RV-C support & parallel operation.
  • Communication interface options:
    • 2×RS485
    • RS485 + CAN (RV-C)
    • RS485 + LIN (CI-BUS)

Video: Overview of the EPEVER TRC Series MPPT Solar Charge Controller in an RV setup, demonstrating its flexible power solution, high MPPT tracking efficiency, and smart monitoring capabilities.

2. Important Safety Instructions

Please keep this manual for future reference.

  • Read all the instructions and warnings carefully in the manual before installation.
  • No user-serviceable components inside the controller; do not attempt to disassemble or repair the controller.
  • Install the controller indoors to avoid component exposure and water ingress.
  • Install the controller in a well-ventilated place; the heat sink temperature will be very high during operation.
  • Do not install the controller in humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other harsh environments.
  • It is recommended to install the proper fast-acting fuses/breakers externally.
  • Disconnect PV array connections and the battery fast-acting fuse/breakers before controller installation and adjustment.
  • Check whether the wiring is tight to avoid the danger caused by heat accumulation due to loose connection.
  • The entire system should be installed and operated by professional personnel.
DANGER: Indicates a high-level hazard that, if not avoided, will result in serious injury or death.
WARNING: Indicates a medium-level hazard that, if not avoided, could result in death or serious injury.
CAUTION: Indicates a low-level hazard that, if not avoided, could result in minor or moderate injury.
NOTICE: Indicates an important reminder during the operation which, if ignored, may result in an equipment error alarm.
Tip: Indicates recommendation for reference.

Information icon Read through the user manual before any operations.

DANGER: Electric shock hazard! Ensure the power supply of the controller is disconnected when performing any operations involving wiring or maintenance.

3. Product Exterior & Components

3.1 Appearance and Ports

EPEVER TRC Series Controller Front View

Figure 1: Front view of the TRC Series Controller with labeled components.

EPEVER TRC Series Controller Bottom View

Figure 2: Bottom view of the TRC Series Controller with labeled ports.

Table 1: Controller Appearance and Ports
No.DescriptionNo.Description
1Indicator6PV terminals
2LCD7Battery terminals
3Buttons8Bluetooth expansion hub
4Grounding terminal9COM: RS485 COM port (RJ45, 5VDC/200mA)
5RTS port10PORT COM port

3.2 Indicators, Buttons, and LCD

EPEVER TRC Series Controller LCD Display

Figure 3: Controller LCD display and buttons.

a) Indicator Status

Table 2: Indicator Status Description
IndicatorColorStatusDescription
PVGreenSolid ONNormal PV connection with low voltage, but no charging.
Solid OFF1. No sunlight; 2. Connection error
Slowly flashing (1Hz)Charging
Fast flashing (4Hz)PV input overvoltage, PV input reverse connection
BATTGreenSolid ONBattery is normal.
Slowly flashing (1Hz)Battery fully charged, SOC low battery alarm
Fast flashing (4Hz)Battery overvoltage, cell overvoltage
OrangeSolid ONBattery Undervoltage (including BMS battery pack under voltage), cell under voltage
RedSolid ONBattery over discharging
Slowly flashing (1Hz)Battery over temperature, battery low temperature, cell over temperature, cell low temperature, BMS charging protection, BMS discharging protection
Fast flashing (4Hz)BMS other faults, BMS sensor fault, lithium battery rated voltage identification error
Charging (green) and battery (orange) flash simultaneouslyEquipment over temperature

b) Buttons Operation

Table 3: Button Functions
ButtonsOperationDescription
Up buttonPress the buttonScroll up
Up buttonPress and hold the button (2s)
  • Enter the setting interface (in the real-time interface).
  • Enter the parameters setting interface (in the setting interface).
  • Confirm the setting parameters.
Down buttonPress the buttonScroll down
Down buttonPress and hold the button (2s)Confirm the setting parameters.
Setting buttonPress the buttonExit the parameters setting interface (in the setting interface).

4. Installation & Connection

4.1 Installation Precautions

  • Be careful when installing batteries. Wear protective goggles when installing flooded lead-acid batteries, and rinse with clean water immediately if contact with battery acid occurs.
  • The battery and PV connections must be guarded against inadvertent contact. Install the solar charge controller in an enclosure.
  • Keep the battery away from any metal objects to prevent battery short circuit.
  • Acidic gases may be generated when charging the battery; ensure the environment is well ventilated.
  • Avoid direct sunlight and rain infiltration for outdoor installation.
  • Do not install the controller in humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other harsh environments.
  • Loose power connections and corroded cables may result in high heat, melting cable insulation, burning surrounding materials, or even causing a fire. Ensure tight connections and secure cables with cable ties to prevent them from swaying while moving the controller.
  • Charge only lead-acid and lithium-ion batteries that are within the control range of this controller.
  • The battery terminals on the controller can be connected to either the same battery or a group of batteries.
  • Select system connection cables according to a current density of no greater than 5A/mm².
  • The stripped length for wiring should not be too long, and the exposed metal part of the wire should not protrude from the metal part of the terminal block.
  • Refer to IEC62109 for the cross-sectional area of the grounding wire, which should not be less than 4mm².
  • The torque for tightening the wiring screws should not be less than 1.2 N·m.

4.2 Installation Requirements

Determine the installation position and ensure adequate heat-dissipation space. When installing the controller, ensure there is enough airflow through the controller's heat sink. Leave at least 150mm of clearance above and below the controller to guarantee natural convection for heat dissipation. If the controller is mounted in a closed cabinet, ensure that heat can be dissipated through the cabinet.

Installation clearance diagram

Figure 4: Recommended installation clearance for proper heat dissipation.

4.3 Wire Size Recommendations

The minimum PV cable specifications depend on the PV array output current, which varies by module type, connection method, and sunlight angle. The PV array's short-circuit current (ISC) must not exceed the controller's maximum PV input current.

Table 4: Recommended PV Array Wire Size
ModelMaximum Input CurrentMaximum Wire Size
TRC120610A4mm²/12AWG
TRC220620A6mm²/10AWG
TRC3106/TRC321030A10mm²/8AWG
TRC4210/TRC4215/TRC441540A16mm²/6AWG
TRC5106/TRC521550A16mm²/6AWG
NOTICE:
  • When PV modules connect in series at the lowest temperature, the total voltage must not exceed the controller's maximum PV open circuit voltage (e.g., 60V for TRC3106, TRC1206, TRC2206, RV5106; 100V for TRC3210, TRC4210; 150V for TRC4215, TRC4415, TRC5215).
  • When PV modules connect in series at 25℃, the total voltage must not exceed the controller's maximum PV open circuit voltage (e.g., 46V for TRC3106, TRC1206, TRC2206, RV5106; 92V for TRC3210, TRC4210; 138V for TRC4215, TRC4415, TRC5215).

Battery wire size should be selected according to the rated current.

Table 5: Recommended Battery Wire Size
ModelRated Charging CurrentMaximum Wire Size
TRC120610A4mm²/12AWG
TRC220620A6mm²/10AWG
TRC3106/TRC321030A10mm²/8AWG
TRC4210/TRC4215/TRC441540A16mm²/6AWG
TRC5106/TRC521550A16mm²/6AWG
NOTICE:
  • The wire size is only for reference. If there is a long distance between the PV array and the controller or between the controller and the battery, thicker cables can be used to reduce voltage drop and improve system performance.
  • For the battery, the recommended wire size is selected according to the conditions that its terminals are not connected to any additional inverter.

4.4 Device Connection

Connect the controller in the sequence of: ①Ground > ②Battery > ③Load > ④PV array > ⑤Communication modules. Disconnect the controller wiring in the reverse order of this diagram.

DANGER: Risk of explosion! Never install the controller in an enclosed space with flooded batteries! Do not install it in a confined area where battery gas can accumulate.
DANGER: Electric shock hazard! The PV array may generate a very high open circuit voltage. Disconnect the circuit breaker or fast-acting fuse first and be careful when wiring.
NOTICE: TRC series controllers have no battery reverse protection. Do not reverse the battery during wiring, otherwise, the controller may be damaged.

4.4.1 Connecting the Ground Cable (PE)

Grounding terminal connection diagram

Figure 5: Grounding terminal connection.

NOTICE:
  • Install the battery in a positive or negative grounded system. Use a single-point grounding connection, as close as possible to the battery, to avoid system fault or ground loops.
  • Do not connect the PV modules to ground. The base of the PV modules shall be grounded to reduce the impact of lightning. Do not connect the grounding of the controller to the PV array. Only one grounding connection point is allowed, and it should be close to the battery.

4.4.2 Connecting the Battery

Battery connection diagram

Figure 6: Battery connection to the controller.

NOTICE:
  • Do not connect the circuit breaker or fast-acting fuse when wiring and ensure that the leads of "+" and "-" poles are connected correctly.
  • A fast-acting fuse with current 1.25 to 2 times the controller's rated current must be installed on the battery side, within 150mm from the battery.
  • Please connect the inverter directly to the battery when connecting an inverter in the system.

4.4.3 Connecting the PV Modules

PV module connection diagram

Figure 7: PV module connection to the controller.

NOTICE: If the controller is used in an area with frequent lightning strikes, an external surge arrester must be installed at the PV input terminals.

4.4.4 Connecting Accessories

a) BMS-Link Module Connection

The controller can be connected to the BMS-Link module via two methods to communicate with compatible lithium battery BMS:

  1. PORT port: If the PORT adopts RS485 communication, connect the BMS-Link module and lithium batteries through the PORT. Set the BMS protocol number to convert different battery manufacturers' protocols to EPEVER's standard.
  2. COM port: If the PORT adopts other communication methods, set the MPMS mode to ON and connect the BMS through the COM port.
b) Temperature Sensor Connection

The controller can be connected to a temperature sensor via three methods to ensure accurate battery temperature sampling. If no remote temperature sensor is connected, the default temperature for battery charging is 25°C without temperature compensation.

  1. RTS port: Connect an external temperature sensor (model: RT-MF58R47K3.81A) through the RTS port to detect battery temperature.
  2. PORT port: When the PORT adopts RS485 communication, connect a remote temperature sensor (model: RTS-D47) through the PORT port. Set the “BPRO (BMS protocol number)” to 32.
  3. COM port: When the PORT adopts other communication methods, connect a remote temperature sensor (model: RTS-D47) through the COM port. Set the MPMS mode to ON and the "BPRO (BMS protocol number)" to 32.
c) Communication Module Connection

Connect communication modules such as WiFi, Bluetooth, TCP, or 4G modules to the RS485 COM port. This allows remote monitoring of the controller or modification of its parameters via an APP on a phone. Refer to the user manuals of the specific communication modules for detailed setting methods.

Communication module connection diagram

Figure 8: Connecting a communication module (e.g., WiFi, TCP, 4G) to the COM port.

5. Operation

5.1 Checking Before Powering On

  • Verify that the controller is installed correctly and securely.
  • Confirm that all terminal wirings are connected correctly.
  • Ensure that terminal polarities are connected correctly.
  • Check that the communication module (if used) is connected correctly and securely.

5.2 Operating the Device

Connect the battery's fast-acting fuse to power on the controller. After the LCD normally displays and the charge enable terminals are connected, connect the PV array's circuit breaker. The charging indicator will flash slowly during PV charging.

Tip: If the controller does not work properly or the fault indicator illuminates after power-on, refer to the Troubleshooting section.

5.3 Parameter Setting

5.3.1 PV Real-time Data

After the controller is powered on and working normally, use the navigation buttons on the LCD to view PV input voltage, PV input current, PV input power, and PV input energy.

5.3.2 Battery Real-time Data

From the PV input energy interface, use the navigation buttons to view battery voltage, battery charging current, battery type, battery SOC, battery temperature, and BMS connection status.

5.3.3 Setting Steps

  1. In the PV/battery real-time data browsing interface, press and hold the 'Up' button to enter the setting interface. Then, use the 'Up' or 'Down' buttons to select the parameter to be set. Press and hold the 'Up' button again to enter the setting interface for that parameter (the parameter value will be blinking). Modify the parameter value using the 'Up' or 'Down' buttons. Press and hold the 'Up' button to confirm the parameter value.
  2. Press the 'Setting' button to exit the parameters setting interface and switch back to the real-time data browsing interface.

5.3.4 Parameters List

The default values and setting ranges for controller parameters on the LCD are provided in the full user manual. Most parameters can be directly modified via the LCD.

5.3.5 Battery Voltage Control Parameters

Detailed tables for lead-acid and lithium battery voltage control parameters, including overvoltage disconnect, charging voltage limit, overvoltage recovery, equalization charging, bulk charging, float charging, bulk recovery, low voltage recovery, undervoltage alarm recovery, undervoltage alarm, low voltage disconnect, and discharging voltage limit, are available in the full user manual. These parameters vary based on battery type (AGM, GEL, FLD, LFP4S, LFP8S, LFP15S, LFP16S, LNCM3S, LNCM6S, LNCM7S, LNCM13S, LNCM14S) and system voltage (12V, 24V, 48V).

5.3.6 Control Strategy Under Lithium Battery Protocol

When the BMS is connected correctly and the BPRO (BMS protocol) is set correctly, the system follows specific control strategies for battery forced charge requests, charging/discharging voltage limits, and current limits. Refer to the full user manual for a detailed table of these strategies and their conversion relationships.

5.3.7 Setting Parameters Remotely

Parameters can be set remotely using PC software or a mobile APP:

  • PC Software: Connect the controller's COM port to a PC USB port using a USB to RS485 communication cable. Use the PC software to set the "USER" voltage parameters.
  • APP (WiFi/Bluetooth Module): Connect an external WiFi or Bluetooth module to the controller's COM port. Use the APP on your phone to set the "USER" voltage parameters via WiFi or Bluetooth signal. Refer to the specific communication module's user manual for detailed setting methods.

6. Maintenance

To maintain long-term working performance, it is recommended to inspect the following items twice a year:

  • Ensure the airflow around the inverter is not blocked, and remove dirt or debris from the heat sink.
  • Check whether the insulation of exposed cables has been damaged by sunlight, friction with other surrounding objects, dryness, insects, or rodents. Repair or replace cables if necessary.
  • Check whether the indicator and display are consistent with the actual operation of the equipment, and note that corrective action should be taken in case of inconsistency or error.
  • Check terminals for signs of corrosion, insulation damage, high temperature, or burning/discoloration. Tighten terminal screws.
  • Check for signs of dirt, insect nesting, and corrosion, and clean up as required.
  • If the lightning arrester has failed, replace it in time to avoid lightning strikes' damage to the controller or even other equipment.
DANGER: Electric shock hazard! Ensure that the power supply of the controller is disconnected when performing the above operations!

7. Troubleshooting

This section typically provides common issues, their possible causes, and solutions. For detailed troubleshooting steps and error codes, please refer to the comprehensive EPEVER TRC Series Solar Charge Controller User Manual (PDF) available at EPEVER User Manual (PDF).

8. Technical Specifications

EPEVER TRC Series Technical Specifications Table

Figure 9: Detailed technical specifications for EPEVER TRC Series Solar Charge Controllers.

For a complete list of technical specifications, including PV input, battery, controller, environmental parameters, and mechanical dimensions for all TRC series models (TRC3106, TRC5106, TRC1206, TRC2206, TRC3210, TRC4210, TRC4215, TRC4415, TRC5215), please refer to the image above or the full user manual.

9. User Tips

This section would typically include helpful advice and common solutions based on user experiences and frequently asked questions. As no specific user reviews or Q&A content was provided, we recommend consulting the official EPEVER support resources or community forums for practical tips from other users.

10. Warranty & Support

For warranty information, technical support, or any product-related inquiries, please contact EPEVER customer service or visit their official website. Always refer to the complete user manual (PDF) for the most accurate and up-to-date information regarding your TRC Series Solar Charge Controller.

A comprehensive PDF version of this user manual is available for download: EPEVER TRC Series User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.