1. Product Overview
The EPEVER TIS series is a new generation of high-current MPPT solar charge and discharge controllers. These controllers feature advanced MPPT control algorithms for improved tracking and response speed of the maximum power point, ensuring high efficiency in various sunlight conditions. They support no-battery mode operation, allowing direct load connection with sufficient PV energy, and are compatible with major lithium battery types, as well as AGM, Gel, and Flooded batteries.
The TIS series offers robust system flexibility, including support for parallel connection of up to 6 units, three-stage charging management, and low-power consumption design for extended standby performance. The controllers are designed with IP32 protection, short-circuit protection, and an isolated RS485 communication interface for remote monitoring via optional WiFi, Bluetooth, TCP, or 4G modules. They are certified to IEC62109 and EMC standards, ensuring safety and reliability for various applications such as RVs, boats, industrial monitoring systems, and small to medium-sized solar power systems.
Key Features:
- Compatible with 12V/24V/48V systems; Charging current: 60A-100A.
- Durable plastic enclosure with IP32 protection.
- Engineered for reliable load output.
- Supports two PV inputs (TIS10415, TIS8425, and TIS10425 models).
- Max. MPPT tracking efficiency ≥99.5%; Max. conversion efficiency: 98.5%.
- Compatible with AGM, Gel, Flooded, LiFePO4 batteries, etc.
- No battery mode: Enables direct load supply with sufficient PV energy.
- Built-in CAN parallel communication port; Max. 6-unit parallel operation (with/without battery).
- Built-in independent BMS communication port; Reliable battery charge/discharge management (direct communication with EPEVER batteries; BMS-LINK module required for other brands).
- Isolated RS485: Optional Bluetooth, WiFi, TCP or 4G modules for remote monitoring.
- Real-time data recording, event logging, and power statistics function.
- Certified to IEC62109 and EMC standards.
2. Important Safety Instructions
Please read and understand all instructions and warnings in this manual before installation and operation. Keep this manual for future reference.
- No user-serviceable components are inside the controller. Do not attempt to disassemble or repair it.
- Install the controller indoors to prevent exposure to elements and water ingress.
- Ensure the installation location is well-ventilated, as the heat sink can become very hot during operation.
- Avoid installing the controller in humid, salt spray, corrosive, greasy, flammable, explosive, or dusty environments.
- Install appropriate fast-acting fuses/breakers externally.
- Disconnect PV array connections and battery fuses/breakers before any installation or adjustment.
- Verify all wiring connections are tight to prevent heat accumulation from loose connections.
- The entire system should be installed and operated by professional personnel.
3. Installation and Connection
3.1 Installation Requirements
- Ensure sufficient airflow around the controller's heat sink. Leave at least 150mm clearance above and below for natural convection.
- If mounted in a closed cabinet, ensure proper heat dissipation.
- Select system connection cables with a current density no greater than 5A/mm².
- The stripped length for wiring should be appropriate, with no exposed metal protruding from the terminal block.
- Refer to IEC62109 for grounding wire cross-sectional area (not less than 4mm²).
- Tighten wiring screws to a torque of not less than 1.2 N·m.
3.2 Device Connection Sequence
Connect the controller in the following sequence: ① Ground > ② Battery > ③ Load > ④ PV array > ⑤ Optional accessories. Disconnect in reverse order.
3.2.1 Connecting the Ground Cable (PE)
The TIS series is a common negative controller. Negative terminals of the PV array, battery, and load can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.
3.2.2 Connecting the Battery
3.2.3 Connecting AC/DC Loads
DC loads can be connected directly to the controller's load terminals. AC loads require connection through a DC/AC inverter, which must be connected directly to the battery. DC load surge current should be less than the product's rated value.
3.2.4 Connecting PV Modules
3.2.5 Connecting Accessories
BMS-Link Module: For lithium batteries with BMS function, connect the BMS-Link module and lithium batteries via port 4. The BMS-Link module converts different BMS protocols to EPEVER standard protocols for communication. The controller connects automatically if the correct protocol number is set.
Remote Temperature Sensor (RTS-D47K): If the battery has no BMS, attach the RTS-D47K close to the battery to detect temperature. Temperature data is transmitted via RS485 communication to the controller. Set BMS protocol number to 32 when connecting RTS-D47K to the BMS port.
Communication Module (WiFi, Bluetooth, TCP, 4G): Connect these modules to the RS485 COM port for remote monitoring and parameter modification via a mobile app. Refer to the specific communication module's user manual for detailed settings.
4. Operation
4.1 Checking Before Powering On
- Verify the controller is installed correctly and securely.
- Confirm all terminal wirings are connected correctly.
4.2 Operating the Device
Connect the battery's fast-acting fuse to power on the controller. Ensure the LCD displays normally and the charge control terminal is properly inserted. Then connect the PV array's circuit breaker. The charging indicator will flash slowly during PV charging.
4.3 Parameter Setting via LCD
The LCD provides real-time data and allows parameter adjustments. Use the buttons to navigate and modify settings.
- PV Real-time Data: View PV1/PV2 input voltage, current, power, and energy.
- Battery Real-time Data: Monitor battery voltage, charging/discharging current, power, SOC, and temperature.
- Load Real-time Data: Check load output current, power, energy, and operating mode.
To enter parameter setting mode, press and hold the 'Set' button. Use the 'Up/Down' buttons to select parameters and adjust values. Confirm settings with the 'Set' button.
4.4 Load Operation Modes
The controller supports various load operation modes, which can be set via the LCD screen or remotely via RS485 communication (PC software, APP).
- Manual Mode (Default): Load ON/OFF is controlled manually or via remote commands.
- Sunset Load ON Mode: Load turns on at sunset for a set duration.
- Sunset Load ON + Timer Mode: Load turns on at sunset for a set duration, then turns off, and can turn on again before sunrise for another set duration.
- Timer Mode: Load ON/OFF time is controlled by a real-time clock.
- Always ON Mode: Load is continuously on after power-up, suitable for 24-hour power supply needs.
- Sunrise Load ON Mode: Load turns on before sunrise for a set duration.
5. Maintenance
To ensure long-term performance, it is recommended to inspect the controller twice a year:
- Ensure proper ventilation and clean dirt/debris from the heat sink.
- Check exposed cables for insulation damage (sunlight, friction, pests) and repair/replace if necessary.
- Verify indicator and display consistency with actual operation; address any fault/error displays.
- Inspect terminal blocks for corrosion, insulation damage, or burn marks; ensure screws are tight.
- Replace failed lightning arresters promptly to prevent damage from lightning strikes.
6. Protections
The EPEVER TIS series controllers incorporate comprehensive electronic protections to ensure safe and stable operation:
- PV Current/Power-Limiting: Limits charging to rated current/power if actual PV input exceeds it.
- PV Short Circuit: Controller is not damaged if PV array is short-circuited when not charging. Avoid short-circuiting during charging.
- PV Reverse Polarity: Controller is not damaged and resumes normal operation after correction. Note: High PV operating power during reverse connection can damage the controller.
- Night Reverse Charging: Prevents battery discharge to PV modules at night.
- Battery Overvoltage: Stops charging if battery voltage exceeds Overvoltage Disconnect Voltage (OVD).
- Battery Over Discharge: Stops discharging if battery voltage falls below Low Voltage Disconnect Voltage (LVD).
- Battery Over Temperature: Stops operation if battery temperature exceeds 65°C, resumes below 55°C.
- Lithium Battery Low Temperature Charging/Discharging: Stops charging/discharging if temperature is below LTCL/LTDL, resumes when above LTCL+2°C/LTDL+2°C.
- Load Overload: Cuts off output if load current exceeds 1.02 times rated current. Automatic recovery attempts are made.
- Load Short-Circuit: Automatically protects and cuts off output if a short circuit occurs.
- Controller Over Temperature: Stops operation if internal temperature exceeds 85°C, resumes below 75°C. Charging power is reduced if temperature exceeds 81°C.
- TVS High Voltage Surge: Internal Transient Voltage Suppressors (TVS) protect against high-voltage surge pulses. External lightning arrester recommended in high-risk areas.
7. Troubleshooting
This section provides guidance for common issues. For persistent problems, contact technical support.
| Status | Error Code | Possible Reasons | Troubleshooting |
|---|---|---|---|
| PV indicator fast flashing green | POV | PV Overvoltage | Check if connected PV open circuit voltage is too high. Alarm clears when voltage drops. |
| PV indicator fast flashing green | PME | PV Work Mode Error | Check if PV connection method matches 'PCM' setting. |
| PV indicator fast flashing green | RPP | PV Reverse Polarity Protection | Check if PV is connected correctly. |
| PV indicator fast flashing green | PPL | PV Power Low | Wait for sufficient sunlight. |
| BATT indicator solid orange | BUV | Battery Undervoltage Alarm | Disconnect loads, check battery voltage. Recharge battery or wait for voltage to restore above UVAR. |
| BATT indicator solid orange | COV | Cell Overvoltage Protection | Check BMS communication status or BMS parameters. |
| BATT indicator solid red | BOD | Battery Over Discharging Protection | Disconnect loads, check battery voltage. Recharge battery or wait for voltage to restore above LVR. |
| BATT indicator slowly flashing red | BOT | Battery Over Temperature | Ensure battery is in a cool, well-ventilated place. Check charging/discharging current. |
| LOAD indicator (yellow) is off | LSC | Load Short Circuit | Disconnect loads, turn off controller, wait 5 min, restart. Contact support if issue persists. |
| LOAD indicator (yellow) is off | LOL | Load Overload | Disconnect loads, turn off controller, wait 5 min, restart. Contact support if issue persists. |
8. Technical Specifications
Below are the detailed technical specifications for the EPEVER TIS Series MPPT Solar Charge Controllers.
| Parameter | TIS6415 / TIS6425 | TIS7425 | TIS8415 / TIS8425 | TIS10415 / TIS10425 |
|---|---|---|---|---|
| Max. Open-circuit Voltage | 150V (@lowest temp), 135V (@25℃) | 250V (@lowest temp), 225V (@25℃) | 150V (@lowest temp), 135V (@25℃) | 250V (@lowest temp), 225V (@25℃) |
| MPPT Voltage Range | (Battery voltage + 2V, > 20V) to 108V (@25℃) for 150V models; (Battery voltage + 2V, > 20V) to 180V (@25℃) for 250V models | |||
| Number of MPPTs | 1 | 1 | 1 | 2 |
| Rated Charging Current | 60A | 75A | 80A | 100A |
| Rated Charging Power (12V/24V/48V) | 780W/1560W/3120W | 975W/1950W/3900W | 1040W/2080W/4160W | 1300W/2600W/5200W |
| Battery Type | AGM (Default) / GEL / FLD / User (LFP / NCM / User for Lithium) | |||
| Rated Voltage | 12/24/48VDC or Auto | |||
| Tracking Efficiency | ≥99.5% | |||
| Max. Conversion Efficiency | 98.3% | 98.5% | 98.4% | 98.4% |
| Operating Temperature | -25℃ to +60℃ | |||
| Storage Temperature | -30℃ to +70℃ | |||
| Ingress Protection | IP32 | |||
| Dimensions (L x W x H) | 270x305x91mm | 270x305x122mm | 270x305x105mm | 308x308x119mm |
| Weight | 3.95kg | 5.6kg | 5kg | 6.65kg |
| Recommended Cable Size | 6AWG/16mm² | 2AWG/35mm² | ||
| Certifications | EN/IEC61000-6-2; EN/IEC61000-6-4; EN/IEC62109-1; IEC62321 | |||
For a complete list of specifications and parameters, please refer to the official user manual PDF: EPEVER TIS Series User Manual (PDF).
9. Warranty and Technical Support
The copyright of this manual belongs to BEIJING EPSOLAR TECHNOLOGY CO., LTD. (EPEVER). EPEVER reserves the right of final interpretation of this manual and all documents related to the product. This manual may be updated, revised, or terminated without prior notice. Please visit the official EPEVER website (www.epever.com) for the latest product information and technical support.
The warranty does not apply to damages caused by improper use, inappropriate environments, exceeding current/voltage/power limits, operating outside rated temperature range, failure to follow instructions, unauthorized disassembly, force majeure events, or damage during transportation.
10. User Tips
- Remote Monitoring: Consider purchasing an optional communication module (WiFi, Bluetooth, TCP, or 4G) to monitor and control your solar system remotely via the EPEVER app. This can provide valuable insights into system performance and allow for convenient adjustments.
- Battery Compatibility: When using lithium batteries from brands other than EPEVER, ensure you have the BMS-Link module for proper communication and reliable battery management.
- Cable Sizing: Always use the recommended cable sizes or thicker, especially for longer distances between the PV array and controller, or between the controller and battery, to minimize voltage drop and improve system performance.
- Heat Dissipation: Regularly check and clean the controller's heat sink to ensure optimal heat dissipation, which is crucial for the longevity and efficiency of the device.