EPEVER TES Series

Contents

EPEVER TES Series MPPT Solar Charge Controller User Manual

Models: TES6415, TES8415, TES10415, TES6425, TES7425, TES8425, TES10425

1. Product Overview

The EPEVER TES series MPPT solar charge controller utilizes a new generation MPPT control algorithm to enhance tracking and response speed of the maximum power point. This design minimizes loss rates and maximizes power point tracking efficiency, response speed, and DC/DC conversion efficiency across various power bands. It effectively captures energy from solar panels under diverse sunlight conditions.

The controller supports no-battery mode operation, allowing direct connection of loads to the battery terminals. It is compatible with major lithium battery types, offering flexible integration and preventing unstable load supply voltage issues caused by internal protection mechanisms of lithium batteries. An excellent low-power design significantly reduces static power consumption, extending system standby time.

Key features include charging current and power limits, automatic power reduction at high temperatures to ensure system stability, and IP32 water-proof and dust-proof protection. It features short-circuit protection and an isolated RS485 communication interface for remote monitoring via optional WiFi, Bluetooth, TCP, or 4G modules. The communication port can be enabled or disabled to further reduce static power consumption.

With self-adaptive three-stage charging, the TES series extends battery life and improves system performance. It includes comprehensive electronic protections against overcharge, over-discharge, and PV reverse polarity, ensuring safe, stable, and long-lasting solar system operation. It supports parallel charging for up to 6 controllers, facilitating system capacity expansion. The controller is ideal for RVs, boats, industrial monitoring systems, and small to medium-sized solar power systems.

Features

  • Low power consumption with static loss less than 50mA.
  • No-battery mode operation.
  • Advanced MPPT technology, with maximum tracking efficiency not less than 99.5%.
  • Supports two PV inputs to improve PV utilization (for TES8425, TES10415, TES10425).
  • Conversion efficiency up to 98.5%.
  • Supports multiple battery types, including lithium batteries.
  • Stable self-activation for lithium batteries.
  • Supports local setting of main control parameters.
  • RS485 communication interface for remote monitoring (WiFi, Bluetooth, TCP, 4G modules).
  • Dual limits for rated charging power and charging current.
  • Automatic power reduction when charging at high temperature.
  • Comprehensive electronic protections.
  • Rated IP32 protection level.
  • Built-in BMS communication port.
  • Built-in CAN parallel communication port.
  • Real-time data logging, event logging, and energy statistics.
  • Compliant with IEC62109, EMC, and other relevant standards.
EPEVER TES Series Solar Charge Controller Overview

Image: EPEVER TES Series Solar Charge Controller overview highlighting key features and applications.

System Diagram

TES Series System Diagram

Image: System diagram illustrating the connection of PV modules, communication module, battery, DC/AC inverter, and AC load.

2. Important Safety Instructions

Please keep this manual for future reference. Read all instructions and warnings carefully before installation and operation.

  • No user-serviceable components are inside the controller; do not attempt to disassemble or repair it.
  • Install the controller indoors to avoid component exposure and water ingress.
  • Install the controller in a well-ventilated place. The heat sink temperature can be very high during operation.
  • Do not install the controller in humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other harsh environments.
  • It is recommended to install proper fast-acting fuses/breakers externally.
  • Disconnect PV array connections and the battery fast-acting fuse/breakers before controller installation and adjustment.
  • Check whether the wiring is tight to avoid danger from heat accumulation due to loose connections.
  • The entire system should be installed and operated by professional personnel.

Symbol Definitions

DANGER

Indicates a high-level hazard that, if not avoided, will result in serious injury or death.

WARNING

Indicates a medium-level hazard that, if not avoided, could result in death or serious injury.

CAUTION

Indicates a low-level hazard that, if not avoided, could result in minor or moderate injury.

NOTICE

Indicates an important reminder during operation which, if ignored, may result in an equipment error alarm.

Tip

Indicates recommendation for reference.

3. Product Exterior and Ports

3.1. Appearance and Ports

EPEVER TES Series Controller Labeled Diagram

Image: Front and bottom view of the TES Series controller with labeled components and ports.

Controller Components and Ports
No.DescriptionNo.Description
1Indicator6Battery terminals
2LCD7PV1 terminals
3Buttons8PV2 terminals
4CAN/RTS/BMS COM interface9Grounding terminal
5COM port (RJ45, with isolation design, 5VDC/200mA)

3.2. Indicators, Buttons, and LCD

The controller features an LCD display and buttons for interaction. The LCD can be viewed clearly when the angle between the user's horizontal sight and the LCD is within 90°.

Indicators

PV and Battery Indicator Status
IndicatorColorStatusDescription
PVGreenSolid ONPV voltage is higher than turn-off voltage, but no charging.
GreenSolid OFF1. No sunlight; 2. Connection error; 3. PV low voltage.
GreenSlowly flashing (1Hz)Charging normally.
GreenFast flashing (4Hz)PV input overvoltage, PV mode error, PV input reverse connection, PV power too low.
BATTGreenSolid ONBattery is normal.
GreenSlowly flashing (1Hz)Battery fully charged, SOC low battery alarm.
GreenFast flashing (4Hz)Battery overvoltage, cell overvoltage.
OrangeSolid ONBattery Undervoltage (including battery pack under voltage), cell under voltage.
RedSolid ONBattery over discharging.
RedSlowly flashing (1Hz)Battery over temperature, battery low temperature, cell over temperature, cell low temperature, BMS charging protection, BMS discharging protection.
RedFast flashing (4Hz)BMS other faults, BMS sensor fault, lithium battery rated voltage identification error alarm.
PV (fast flashing green) & BATT (fast flashing orange)Equipment over temperature, DSP communication failure.

Buttons

Button Operations
ButtonOperationDescription
↻Press the button (< 50ms)Exit the current interface.
▲▼Press the button (< 50ms)
  • Browse the interface: Up/Down.
  • Set the browsing interface: Up/Down.
  • Parameters setting interface: Increase or decrease the parameter value as per step size.
Press and hold the button (> 2.5s)
  • Browse the interface: invalid.
  • Set the browsing interface: invalid.
  • Parameters setting interface: Increase or decrease the parameter value quickly as per step size.
↻Press the button (< 50ms)Confirm the setting parameters.
↻Press and hold the button (> 2.5s)
  • Switch the real-time interface to setting browsing interface.
  • Switch the setting browsing interface to parameter settings interface.
  • Confirm the setting parameters.

3.3. Dimensions

The physical dimensions of the TES series controllers vary by model. For detailed measurements, please refer to the technical specifications table in Section 9.

TES Series Controller Front View

Image: Front view of the TES Series controller.

TES Series Controller Side View

Image: Side view of the TES Series controller, showing the heat sink.

4. Installation and Connection

4.1. Precautions

  • Be careful when installing batteries. Wear protective goggles when installing flooded lead-acid batteries, and rinse with clean water immediately if contact with battery acid occurs.
  • Battery and PV connections must be guarded against inadvertent contact. Install the solar charge controller in an enclosure.
  • Keep the battery away from any metal objects to prevent short circuits.
  • Acidic gases may be generated when charging the battery; ensure the environment is well ventilated.
  • Avoid direct sunlight and rain infiltration for outdoor installation.
  • Do not install the controller in humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other harsh environments.
  • Loose power connections and corroded cables can result in high heat, melting insulation, burning materials, or even fire. Ensure tight connections and secure cables with ties to prevent swaying.
  • Charge only lead-acid and lithium-ion batteries within the control range of this controller.
  • The battery terminals on the controller can be connected to either a single battery or a group of batteries.
  • Select system connection cables with a current density of no greater than 5A/mm².
  • The stripped length for wiring should not be too long, and exposed metal parts should not protrude from the terminal block.
  • Refer to IEC62109 for grounding wire cross-sectional area (not less than 4mm²).
  • The torque for tightening wiring screws should be not less than 1.2 N·m.

4.2. Installation Requirements

When installing the controller, ensure sufficient airflow through the heat sink. Leave at least 150mm of clearance above and below the controller to guarantee natural convection for heat dissipation. If mounted in a closed cabinet, ensure heat can be dissipated.

4.3. Wire Size

The wiring and installation methods must conform to national and local electrical code requirements.

The minimum PV cable specifications depend on the PV array output current, which varies by module type, connection method, and sunlight angle. Refer to the short-circuit current (Isc) value in the PV module specifications sheet. The PV array's Isc must not exceed the controller's maximum PV input current.

PV Input Current and Wire Size
ModelMaximum Input CurrentMaximum Wire Size
TES6415, TES642560A16mm²/6AWG
TES742575A25mm²/4AWG
TES841580A
TES842540A*216mm²/6AWG
TES10415, TES1042550A*2

Battery wire size should be selected according to the rated current. If there is a long distance between the PV array and the controller or between the controller and the battery, thicker cables can be used to reduce voltage drop and improve system performance.

Battery Wire Size by Model
ModelRated Charging CurrentMaximum Wire Size
TES6415, TES642560A16mm²/6AWG
TES742575A25mm²/4AWG
TES8415, TES842580A
TES10415, TES10425100A35mm²/2AWG

4.4. Device Connection

DANGER: Risk of explosion! Never install the controller in an enclosed space with flooded batteries! Do not install it in a confined area where battery gas can accumulate. Electric shock hazard! The PV array may generate a very high open circuit voltage. Disconnect the circuit breaker or fast-acting fuse first and be careful when wiring. TES series controllers do not have battery reverse polarity protection. Do not reverse battery connections, as this may cause damage.

Connect the controller in the sequence of: ① Ground > ② Battery > ③ PV array > ④ Optional accessories. Disconnect in the reverse order.

4.4.1. PV Independent Input

In PV independent mode, the TES series controller can be connected directly to an inverter when there is no battery. The inverter must be connected to the battery terminals of the controller and meet specific power conditions.

PV Independent Input Wiring Diagram

Image: Wiring diagram for PV independent input mode, showing connections to PV modules, controller, and inverter.

4.4.2. Battery Mode Wiring

In a system with a battery connected, if an inverter is needed, connect the inverter directly to the battery pack.

Battery Mode Wiring Diagram

Image: Wiring diagram for battery mode, illustrating connections between PV, controller, and battery, with an inverter connected directly to the battery pack.

4.4.3. Connecting the Ground Cable (PE)

The TES series is a common negative controller. Negative terminals of the PV array and battery can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on the shell must be grounded to effectively shield electromagnetic interference and prevent electric shock.

4.4.4. Connecting the Battery

Do not connect the circuit breaker or fast-acting fuse when wiring. Ensure the leads of '+' and '-' poles are connected correctly. A fast-acting fuse (1.25 to 2 times the controller's rated current) must be installed on the battery side, no longer than 150mm from the battery.

4.4.5. Connecting the PV Modules

DANGER: Electric shock hazard! The PV array can generate very high voltage. Disconnect the circuit breaker before wiring, and ensure the leads of '+' and '-' poles are connected correctly. If the controller is used in an area with frequent lightning strikes, an external surge arrester must be installed at the PV input and utility input terminals.

4.4.6. Connecting Accessories

a) Connect the BMS-Link module: When using lithium batteries with BMS function, connect the BMS-Link module and lithium batteries through port 4. Set the BMS protocol number (BPRO, UBS) correctly. The BMS-Link module converts different lithium battery manufacturers' BMS protocols to the controller's standard protocols for communication.

b) Connect the remote temperature sensor (model: RTS-D47K): If the battery has no BMS function, attach the RTS-D47K close to the battery to detect its temperature. The temperature data is transmitted via RS485 communication to the controller. Set the BMS protocol number to 32 when connecting the remote temperature sensor to the BMS port. If not connected, the default charging temperature is 25°C without compensation.

c) Connect the communication module: Connect communication modules (WiFi, Bluetooth, TCP, or 4G) to the RS485 COM port for remote monitoring or parameter modification via a phone app. Refer to the specific communication module's user manual for detailed settings.

5. Operation

5.1. Checking Before Powering On

  • Ensure the controller is installed correctly and securely.
  • Verify that all terminal wirings are connected correctly.

5.2. Operating the Device

Connect the battery's fast-acting fuse to power on the controller. Ensure the LCD displays normally and the charge control terminal is properly inserted. Then, connect the PV array's circuit breaker. The charging indicator should flash slowly during PV charging. If the controller does not work properly or the fault indicator activates after power-on, refer to the Troubleshooting section.

5.3. Parameter Setting

After the controller is powered on and working normally, you can view PV and battery real-time data and adjust parameters using the buttons and LCD.

5.3.1. PV Real-time Data

From the initial LCD interface, press the 'Up/Down' button to cycle through PV real-time data, including PV1 input voltage, current, power, and energy, as well as PV2 input voltage, current, power, and energy (if applicable). Models with single PV input will only display PV1 data.

5.3.2. Battery Real-time Data

Continue pressing the 'Up/Down' button from the PV real-time data interface to display battery real-time data, including battery voltage, charging current, charging/discharging power, SOC, and temperature.

5.3.3. Setting Steps

  1. In the PV/battery real-time data browsing interface, press and hold the 'Enter' button to enter the parameter setting interface.
  2. Press the 'Up/Down' button to select the parameter to be set.
  3. Press and hold the 'Enter' button again to enter the setting interface for the selected parameter (the value will be blinking).
  4. Modify the parameter value by pressing the 'Up/Down' button.
  5. Press the 'Enter' button to confirm the new parameter value.
  6. Press the 'Exit' button to exit the parameter setting interface and return to the real-time data browsing interface.

5.3.4. Parameters List

The default values and setting ranges for controller parameters are displayed on the LCD. Most parameters can be modified via PC or APP, except for some read-only values.

5.3.5. Battery Voltage Control Parameters

The controller supports various battery types, including AGM, GEL, FLD, LFP, and NCM, with specific voltage control parameters for each. These parameters include Overvoltage Disconnect Voltage, Charging Voltage Limit Voltage, Overvoltage Recovery Voltage, Equalization Charging Voltage, Bulk Charging Voltage, Float Charging Voltage, Bulk Recovery Voltage, Low Voltage Recovery Voltage, Undervoltage Alarm Recovery Voltage, Undervoltage Alarm Voltage, Low Voltage Disconnect Voltage, and Discharging Voltage Limit Voltage. For detailed tables of these parameters for 12V, 24V, and 48V systems, please refer to the full user manual (PDF).

5.3.6. Control Strategy Under Lithium Battery Protocol

When a BMS is correctly connected and configured, the system follows specific control strategies for charging and discharging based on BMS data, including forced charge requests, charging voltage limits, charging current limits, and full charge status. The controller converts BMS-provided voltage limits to its internal values for operation.

5.3.7. Setting Parameters Remotely

Parameters can be set remotely using PC software or a mobile APP. Connect the controller's COM port to a PC via a USB to RS485 communication cable to use PC software. Alternatively, connect an optional WiFi or Bluetooth module to the COM port to adjust parameters via the EPEVER APP on your smartphone.

6. Maintenance

To maintain long-term working performance, it is recommended to inspect the following items twice a year:

  • Ensure proper ventilation and heat dissipation around the controller; clean dirt or debris from the heat sink.
  • Check whether the insulation of exposed cables has been damaged by sunlight, friction with objects, insects, or rodents. Repair or replace cables if necessary.
  • Check whether the indicator and display are consistent with actual equipment operation, and note any fault/error displays for corrective action.
  • Inspect terminal blocks for corrosion, insulation damage, or high-temperature burn marks; ensure terminal screws are tight.
  • If the lightning arrester has failed, replace it promptly to prevent lightning strike damage to the controller or other equipment.

DANGER: Electric shock hazard! Ensure the power supply of the controller is disconnected when performing any maintenance operations.

7. Protections

The TES series controller incorporates various protection mechanisms to ensure safe and reliable operation:

Controller Protections
ProtectionDescription
PV current/power-limitingCharges the battery at the rated current/power if the actual PV array current/power exceeds it.
PV reverse polarityController will not be damaged and resumes normal operation after correction. (Note: Damage may occur if actual operating power exceeds 1.5 times rated charging power during reverse connection).
Night reverse chargingPrevents battery discharge to PV modules at night.
Battery overvoltageAutomatically stops charging if battery voltage exceeds 'Overvoltage Disconnect Voltage'.
Battery over dischargeAutomatically stops discharging if battery voltage falls below 'Low Voltage Disconnect Voltage'.
Battery over temperatureStops working if battery temperature (from external sensor) exceeds 65°C, resumes below 55°C.
Lithium battery low temperature chargingStops charging if detected temperature is lower than 'LTCL', resumes when higher than 'LTCL'.
Controller over temperatureStops operating if internal temperature exceeds 85°C, resumes below 75°C. Charging power reduces gradually from 81°C.
TVS high voltage surgeInternal Transient Voltage Suppressors (TVS) protect against high-voltage surge pulses with less energy. External lightning arrester recommended in frequent lightning areas.

8. Troubleshooting

This section provides guidance for common issues encountered with the TES series controller. Refer to the table below for error codes, possible reasons, and troubleshooting steps.

Troubleshooting Guide
StatusError CodePossible ReasonsTroubleshooting
PV indicator is fast flashing green.POVPV OvervoltageCheck if connected PV open circuit voltage is higher than max. PV open circuit voltage. Alarm clears when PV open circuit voltage is lower than max. PV open circuit voltage minus 5V.
PMEPV Work Mode ErrorCheck if PV connection method is consistent with 'PCM (PV Connection Mode)' settings.
RPPPV Reverse Polarity ProtectionCheck if PV is connected correctly.
PPLPV Power LowWait for sufficient sunlight for the fault to clear.
BATT indicator is solid orange.BUVBattery Undervoltage AlarmDisconnect loads, check battery voltage. After battery charges above 'UVAR', it resumes normal operation.
CUVCell Undervoltage ProtectionCheck BMS communication status or BMS parameters.
BATT indicator is solid red.BODBattery Over Discharging ProtectionDisconnect loads, check battery voltage. After battery charges above 'LVR', it resumes normal operation.
BATT indicator is fast flashing red.BOFBMS Other FaultCheck if battery BMS connection is normal.
BSFBMS Sensor FaultCheck if battery BMS connection is normal.
LBVELithium Battery Rated Voltage Identification ErrorCheck if lithium battery is connected correctly or if BMS uploaded voltage is consistent with controller battery terminals.
BATT indicator is fast flashing green.BOVBattery Overvoltage ProtectionDisconnect charging, check battery voltage. Verify battery voltage matches rated level or 'OVD' setting. Alarm clears when voltage drops below 'OVR'.
COVCell Overvoltage ProtectionCheck BMS communication status or BMS parameters.
BATT indicator is slowly flashing red.BOTBattery Over TemperatureEnsure battery is in a cool, well-ventilated place. Check if actual charging/discharging current exceeds 'MCC' values. Resumes normal control when temperature drops below 'BATT OTPR'.
BLTBattery Low TemperatureCheck if ambient temperature is lower than 'LTCL'. Resumes normal operation when ambient temperature is higher than 'LTCL + 2°C'.
BATT indicator is slowly flashing green.SLBPSOC Low Battery ProtectionCharge the battery to 'LBAR (Low Battery Alarm Recovery SOC)'.
PIDRParallel ID RepetitionCheck if IDs of parallel equipment are repeated.
PV indicator is fast flashing green. BATT indicator is fast flashing orange.DOTDevice Over TemperatureEnsure controller is in a cool, well-ventilated place. Resumes normal charging when temperature drops below 'DOT'.
DCFDSP Communication FaultTurn off controller, wait 5 minutes, then turn on. If error persists, contact technical support.

9. Technical Specifications

The following tables detail the technical specifications for the EPEVER TES Series MPPT Solar Charge Controllers.

9.1. TES6415, TES8415, TES10415 Models

Technical Specifications (TES6415, TES8415, TES10415)
ParameterModel
TES6415TES8415TES10415
PV Input (DC)
Maximum Open-circuit Voltage150V (@lowest temperature); 135V (@25°C)
MPPT Voltage Range(Battery voltage plus 2V, and > 20V) to 108V (@25℃)
Number of MPPTs112
Rated Charging Current60A80A100A
Rated Charging Power780W/1,560W/3,120W1,040W/2,080W/4,160W1,300W/2,600W/5,200W
Battery
Battery TypeAGM (Default)/GEL/FLD/User
Lithium Battery TypeLFP/NCM/User
Rated Voltage12/24/48VDC or Auto
Temperature Compensation Coefficient-3mV/°C/2V (Default)
Controller
Output Voltage Range8-62V
Static Loss (Enabled Communication)98mA/12V; 60mA/24V; 46mA/48V
Static Loss (Disabled Communication)48mA/12V; 25mA/24V; 14mA/48V
Grounding TypeCommon negative grounding
Communication Method5VDC/200mA (RJ45)
Efficiency
Tracking Efficiency≥ 99.5%
Maximum Conversion Efficiency98.3%98.3%98.4%
Environmental Parameters
Operating Temperature-25°C to +60°C (> 40°C derating)
LCD Operating Temperature-20°C to +70°C
Storage Temperature-30°C to +70°C
Relative Humidity5%-95% (N.C.)
Altitude< 5,000m (> 2,000m derating)
Ingress ProtectionIP32
Pollution DegreeII
Mechanical Parameters
Dimensions (L × W × H)270mm × 305mm × 91mm270mm × 305mm × 105mm308mm × 308mm × 119mm
Mounting Hole SizeΦ6.5mm
Weight3.85kg4.9kg6.55kg
Recommended Cable Size6AWG/16mm²
Others
CertificationsEN/IEC61000-6-2; EN/IEC61000-6-4; EN/IEC62109-1; IEC62321
Technical Specifications Table for TES6415, TES8415, TES10415

Image: Detailed technical specifications table for TES6415, TES8415, TES10415 models.

9.2. TES6425, TES7425, TES8425, TES10425 Models

Technical Specifications (TES6425, TES7425, TES8425, TES10425)
ParameterModel
TES6425TES7425TES8425TES10425
PV Input (DC)
Maximum Open-circuit Voltage250V (@ lowest temperature); 225V (@25℃)
MPPT Voltage Range(Battery voltage plus 2V, and > 20V) to 180V (@ 25°C)
Number of MPPTs1122
Rated Charging Current60A75A80A100A
Rated Charging Power780W/1,560W/3,120W975W/1,950W/3900W1,040W/2,080W/4,160W1,300W/2,600W/5,200W
Battery
Battery TypeAGM (Default)/GEL/FLD/User
Lithium Battery TypeLFP/NCM/User
Rated Voltage12/24/48VDC or Auto
Temperature Compensation Coefficient-3mV/°C/2V (Default)
Controller
Output Voltage Range8-62V
Static Loss (Enabled Communication)98mA/12V; 60mA/24V; 46mA/48V
Static Loss (Disabled Communication)48mA/12V; 25mA/24V; 14mA/48V
Grounding TypeCommon negative grounding
Communication Method5VDC/200mA (RJ45)
Efficiency
Tracking Efficiency≥ 99.5%
Maximum Conversion Efficiency98.5%98.4%98.3%98.4%
Environmental Parameters
Operating Temperature-25°C to +60°C (> 40°C derating)
LCD Operating Temperature-20°C to +70°C
Storage Temperature-30°C to +70°C
Relative Humidity5%-95% (N.C.)
Altitude< 5,000m (> 2,000m derating)
Ingress ProtectionIP32
Pollution DegreeII
Mechanical Parameters
Dimensions (L × W × H)270mm × 305mm × 105mm270mm × 305mm × 122mm308mm × 308mm × 119mm308mm × 308mm × 119mm
Mounting Hole SizeΦ6.5mm
Weight4.85kg5.5kg6.50kg6.6kg
Recommended Cable Size2AWG/35mm²
Others
CertificationsEN/IEC61000-6-2; EN/IEC61000-6-4; EN/IEC62109-1; IEC62321

10. User Tips

Based on common user inquiries and best practices, here are some helpful tips for operating your EPEVER TES Series MPPT Solar Charge Controller:

  • Ensure Adequate Ventilation: Always provide ample clearance (at least 150mm above and below) around the controller's heat sink to facilitate natural convection and prevent overheating, especially during high-power operation.
  • Verify Wiring Tightness: Regularly check all wiring connections to ensure they are tight. Loose connections can lead to heat accumulation, increased resistance, and potential damage to the system.
  • Correct BMS Protocol for Lithium Batteries: If using lithium batteries with a BMS, ensure the correct BMS protocol number is set in the controller's parameters for seamless communication and optimal battery management.
  • Utilize Remote Monitoring: Take advantage of the optional WiFi or Bluetooth modules to monitor your system's performance and adjust parameters remotely via the EPEVER APP. This allows for convenient system management and troubleshooting.
  • Proper Fuse Sizing: Always use fast-acting fuses on the battery side with a current rating 1.25 to 2 times the controller's rated current, and install them within 150mm of the battery.

11. Technical Support

For technical inquiries regarding your EPEVER TES Series MPPT Solar Charge Controller, please contact us through the following channels:

  • Service Hotline: 010-82894896 / 82894112, 0752-3889706, 0755-89236770
  • Email: sales@epever.com
  • For more product information, please visit the official website: www.epever.com

You can also download the full user manual in PDF format for detailed instructions and further technical information: EPEVER TES Series User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.