EPEVER Tracer2206AN G3, Tracer2210AN G3

Contents

EPEVER Tracer-AN G3 Series MPPT Solar Charge Controller User Manual

Models: Tracer2206AN G3, Tracer2210AN G3

1. Introduction

1.1 Overview

Tracer-AN G3 series controllers, based on a new design concept, adopt the solar charge controller as the main component. With optional 4G or Wi-Fi modules, end-users can read and write parameters by phone APP conveniently.

Adopting the advanced MPPT control algorithm, the Tracer-AN solar controller can minimize the maximum power point loss rate and time. This product tracks the PV array's maximum power point and obtains maximum energy under any situation. Compared with the PWM charging method, MPPT solar controllers can increase the energy utilization ratio by 10%-30%. Charging current limit, charging power limit, and high temperature charging automatic power reduction fully ensure system stability when access to excess PV modules and high temperature running. A professional protection chip for the RS485 port further improves reliability and meets different application requirements.

The Tracer-AN series controller owns a self-adaptive three-stage charging mode based on a digital control circuit. It effectively prolongs the battery lifespan and significantly improves the system's performance. These controllers are equipped with comprehensive electronic protections to ensure the solar system is more reliable and durable. This controller can be widely used for RV, household systems, field monitoring, and many other applications.

1.2 Features

  • High quality and low failure rate components of ST or IR to ensure service life.
  • Advanced MPPT technology, with Max. tracking efficiency higher than 99.5%.
  • Advanced MPPT control algorithm to minimize lost rate and lost time.
  • Accurate recognizing and tracking technology of multi-peaks maximum power point.
  • Wider MPP (maximum power point) running voltage to optimize PV utilization.
  • Maximum DC/DC conversion efficiency of 98%.
  • Support multi battery types including lithium batteries.
  • Equipped with a stable self-activation function for the lithium battery.
  • Set the battery voltage parameters on the LCD.
  • Battery temperature compensation.
  • Limit the charging power & charging current to no higher than the rated value.
  • Real-time energy statistics function.
  • Charging power reduction automatically for over-temperature.
  • RS485 communication interface with optional 4G or Wi-Fi modules for remote monitoring.
  • Standard Modbus communication protocol based on the RS485 communication bus, extending the communication distance.
  • A power protection chip, which can provide 5VDC/200mA power and over-current, short-circuit protections, is adopted by the communication interface.
  • Setting parameters via the PC software, APP, or remote meter.
  • Constant voltage output function.
  • Comprehensive electronic protections.
  • Multiple load work modes.
  • Low self-consumption, lower than 10mA.
  • Operation at full load without charging power reduced in the working temperature range.

1.3 Naming Rules

The model naming convention for the Tracer-AN G3 series is as follows:

Tracer X Y Z AN G3

  • X: Product series (e.g., 4 for 40A, 2 for 20A).
  • Y: Rated charging & discharging current (e.g., 1 indicates 10A; 2 indicates 20A; 3 indicates 30A; 4 indicates 40A).
  • Z: Battery rated voltage (e.g., 2 indicates 12/24VDC).
  • AN: Common negative system.
  • G3: The 3rd generation product.

2. Important Safety Instructions

Please keep this manual for future reference.

  • Read all instructions and warnings carefully in the manual before installation.
  • No user-serviceable components inside the controller. Do not disassemble or attempt to repair the controller.
  • Mount the controller indoors. Avoid exposure to components and do not allow water to enter the controller.
  • Install the controller in a well-ventilated place. The controller's heat sink may become hot during operation.
  • It is suggested to install appropriate external fast-acting fuses/breakers.
  • Disconnect PV array connections and the battery's fast-acting fuse/breakers before controller installation and adjustment.
  • Power connections must remain tight to avoid excessive heating from a loose connection.

NOTICE:

Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.

2.1 Disclaimers

The warranty does not apply to the following conditions:

  • Damage caused by improper use or inappropriate environment (such as humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments).
  • The actual current/voltage/power exceeds the limit value of the controller.
  • Damage caused by working temperature exceeding the rated range.
  • Arc, fire, explosion, and other accidents caused by failure to follow the controller stickers or manual instructions.
  • Unauthorized dismantling or attempted repair.
  • Damage caused by force majeure.
  • Damage occurred during transportation or handling.

3. Setup and Installation

3.1 Installation Precautions

  • Please read the instructions to familiarize yourself with the installation steps before installation.
  • Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
  • Be careful when installing the batteries. Please wear eye protection when installing open-type lead-acid batteries and rinse with clean water in time for battery acid contact.
  • Keep the battery away from any metal objects, which may cause a short circuit of the battery.
  • Acid gas may be generated when the battery is charged. Confirm that the surrounding environment is well ventilated.
  • Avoid direct sunlight and rain infiltration when installing it outdoors.
  • Loose power connectors and corroded wires may produce high heat that can melt wire insulation, burn surrounding materials, or even cause a fire. Ensure tight connections and secure cables with cable clamps to prevent them from swaying in moving applications.
  • Only charge lead-acid and lithium-ion batteries within the control range of this controller.
  • The battery connector may be wired to another battery or a bank of batteries. The following instructions refer to a singular battery. Still, it is implied that the battery connection can be made to either one battery or a group of batteries in a battery bank.
  • Select the system cables according to 5A/mm² or less current density.
  • The wire size of the grounding wire should not be less than 4mm².
  • The torque of tightening the wiring screw should not be less than 1.2 N·m.

3.2 Requirements for the PV Array

Serial connection (string) of PV modules

As the core component of the solar system, the controller needs to suit various types of PV modules and maximize solar energy conversion into electricity. According to the open-circuit voltage (VOC) and the maximum power point voltage (VMPP) of the MPPT controller, the serial connection of PV modules suitable for different controllers can be calculated. The below tables are for reference only.

Tracer1206/2206AN G3 PV Array Requirements

System Voltage36-cell (Voc < 23V)48-cell (Voc < 31V)54-cell (Voc < 34V)60-cell (Voc < 38V)
Max.BestMax.BestMax.BestMax.Best
12V22111111
24V22------
System Voltage72-cell (Voc < 46V)96-cell (Voc < 62V)Thin-film Module (Voc > 80V)
Max.BestMax.Best
12V11---
24V11---

Note: The above parameters are calculated under the STC (Standard Test Condition)—temperature at 25°C, air mass 1.5, irradiance 1,000W/m².

Tracer1210/2210/3210/4210AN G3 PV Array Requirements

System Voltage36-cell (Voc < 23V)48-cell (Voc < 31V)54-cell (Voc < 34V)60-cell (Voc < 38V)
Max.BestMax.BestMax.BestMax.Best
12V42212121
24V43222222
System Voltage72-cell (Voc < 46V)96-cell (Voc < 62V)Thin-film Module (Voc > 80V)
Max.BestMax.Best
12V21111
24V21111

Note: The above parameters are calculated under the STC (Standard Test Condition)—temperature at 25°C, air mass 1.5, irradiance 1,000W/m².

NOTICE:

The total voltage must not exceed the PV maximum open-circuit voltage when the PV modules are connected in series. The PV maximum open-circuit voltage is 46V (Tracer**06AN G3) or 92V (Tracer**10AN G3) at 25°C environment temperature.

3.3 Wire Size

The wiring and installation methods conform to national and local electrical code requirements.

PV Wire Size

The PV array's output current varies with size, connection method, and sunlight angle. Its ISC (short circuit current) can calculate the minimum wire size. Please refer to the ISC value in the PV module's specifications. When the PV modules are connected in series, the total ISC equals any PV module's ISC. When the PV modules are connected in parallel, the total ISC equals the sum of the PV module's ISC. The PV array's ISC must not exceed the controller's maximum PV input current. For max. PV input current and max. PV wire size, please refer to the table below:

ModelMax. PV Input CurrentMax. PV Wire SizeCircuit Breaker
Tracer1206/1210AN G310A4mm²/12AWG16A/125V/2 P
Tracer2206/2210AN G320A6mm²/10AWG32A/125V/2 P
Tracer3210AN G330A10mm²/8AWG40A/125V/2 P
Tracer4210AN G340A16mm²/6AWG63A/125V/2 P

Battery and Load Wire Size

The battery and load wire size conform to the rated current, and the reference size is as below:

ModelRated Charge CurrentRated Discharge CurrentBattery Wire SizeLoad Wire SizeCircuit Breaker
Tracer1206/1210AN G310A10A4mm²/12AWG4mm²/12AWG16A/125V/2 P
Tracer2206/2210AN G320A20A6mm²/10AWG6mm²/10AWG32A/125V/2 P
Tracer3210AN G330A30A10mm²/8AWG10mm²/8AWG40A/125V/2 P
Tracer4210AN G340A40A16mm²/6AWG16mm²/6AWG63A/125V/2 P

NOTICE:

  • The wire size is only for reference. Suppose there is a long distance between the PV array and the controller or between the controller and the battery. In that case, larger wires can be used to reduce the voltage drop and improve performance.
  • The recommended wire is selected for the battery according to the conditions that its terminals are not connected to any additional inverter.

3.4 Mounting

DANGER:

  • Explosion hazard! Never install the controller in a sealed enclosure with FLD batteries! Do not install the controller in a confined area where battery gas can accumulate.
  • Electric shock hazard! The PV array may generate a high open-circuit voltage when wiring the PV modules. Disconnect the breaker or fast-acting fuse first, and be careful when wiring.

The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.

Step 1: Determine the installation location and heat-dissipation space.

Diagram showing mounting dimensions and clearances for the EPEVER solar charge controller.
Figure 3-1: Mounting dimensions and recommended clearances (150mm top/bottom, 7mm side, 5mm mounting holes).

3.5 Connection Diagram

Step 2: Connect the system in the order of ①battery > ②load > ③PV array by the following schematic wiring diagram, and disconnect the system in the reverse order.

Connection diagram for a solar charge controller system including PV panel, battery, DC load, inverter, and AC load.
Figure 3-2: General Connection Diagram. Shows solar panel (3), controller, battery (1), DC load (2), inverter, and AC load. Supported battery types: Lead-acid (Sealed, Flooded, GEL, User) and Lithium-ion (LiFePO4, Li(NiCoMn)O2, User).

NOTICE:

  • Please do not connect the circuit breaker or fast-acting fuse during the wiring and ensure that the electrode polarity is correctly connected.
  • A fast-acting fuse whose current is 1.25 to 2 times the controller's rated current must be installed on the battery side with a distance from the battery no longer than 150mm.
  • The cable length of the battery should not exceed 3 meters.
  • The recommended cable length of the PV array should not exceed 3 meters (Note: If the cable length of the PV array is less than 3 meters, the system meets EN/IEC61000-6-3 requirements. If more than 3 meters, the system may not meet EN/IEC61000-6-3 requirements).
  • Suppose the controller is to be used in an area with frequent lightning strikes or an unattended area. In that case, it must install an external surge arrester.
  • If an inverter is to be connected to the system, connect the inverter directly to the battery, not to the load side of the controller.

3.6 Grounding

Tracer-AN G3 series are common-negative controllers. Negative terminals of the PV array, the battery, and the load can be grounded simultaneously, or any negative terminal is grounded. However, according to practical application, the negative terminals of the PV array, battery, and load can also be ungrounded. However, the grounding terminal on its shell must be grounded. It shields electromagnetic interference and avoids electric shock to the human body.

NOTICE:

It is recommended to use a common-negative controller for common-negative systems, such as the RV system. The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in the common-negative system.

3.7 Connect Accessories

Connect the temperature sensor

Diagram showing connections for remote temperature sensor, solar panel, battery, load, and RJ45 communication port.
Figure 3-3: Detailed connection points including remote temperature sensor, solar panel terminal, battery terminal, load terminal, and RJ45 communication port. Also shows wire gauges (10A-12AWG, 20A-10AWG, 30A-8AWG, 40A-6AWG).

NOTICE:

Suppose the remote temperature sensor is not connected to the controller or is damaged. In that case, the controller will charge or discharge the battery at the default 25 ℃ (no temperature compensation).

Connect the accessories for RS485 communication

Refer to Section 4.3 Setting for details on RS485 communication.

Note: The internal circuit of the RS485 port has no isolation design. Connecting an RS485 communication isolator to the port is recommended before communicating.

3.8 Power On the Controller

Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (the controller operates normally when the indicator is lit green). Connect the fast-acting fuse and circuit breaker of the load and PV array. Then the system will be operating in preprogrammed mode.

Note: If the controller is not operating properly or the battery indicator on the controller shows an abnormality, please refer to Section 6.2 Troubleshooting.

4. Operation

4.1 LCD Display

Front view of the EPEVER solar charge controller with its LCD display and buttons.
Figure 4-1: EPEVER Solar Charge Controller LCD Display.

Note: The display screen can be viewed clearly when the angle between the end-user's horizontal sight and the display screen is within 90°. If the angle exceeds 90°, the information on the display screen cannot be viewed clearly.

4.2 Buttons

ModeNote
Load ON/OFFIt can turn the load On/Off via the ENTER button in manual load mode.
Clear faultPress the ENTER button.
Browsing modePress the SELECT button.
Setting modePress the ENTER button and hold on 5s to enter the setting mode. Press the SELECT button to set the parameters. Press the ENTER button to confirm the setting parameters or no operation for 10s. It will exit the setting interface automatically.

4.3 Interface

Status Description

The LCD displays various parameters and statuses. Here are some common indicators:

NameIconStatus
PVSolar panel icon with sun/moonDay / Night
Solar panel icon with 'No charge' symbolNo charge
Solar panel icon with 'Charging' symbolCharging
PVPV icon with voltage/current/energyPV array's voltage, current, and generated energy
BATT.Battery icon with charge levelBattery capacity, In charging
BATT. BATT. TYPEBattery icon with voltage/current/tempBattery Voltage, Current, Temperature, Battery type
LOADLight bulb icon with 'ON' symbolLoad ON
Light bulb icon with 'OFF' symbolLoad OFF
LOADLoad icon with current/energyCurrent/Consumed energy/Load mode

Error Codes

StatusIconInstruction
Battery over-dischargedBattery icon with empty frame, blinking fault iconBattery level shows empty, battery frame blink, fault icon blink
Battery overvoltageBattery icon with full frame, blinking fault iconBattery level shows full, battery frame blink, fault icon blink
Battery overheatingBattery icon with current value, blinking fault iconBattery level shows current value, battery frame blink, fault icon blink
Load failureLight bulb icon with fault symbolOverload; Load short circuit

Note: When the load current reaches 1.02-1.05 times, 1.05-1.25 times, 1.25-1.35 times, and 1.35-1.5 times more than the rated value, the controller will automatically turn off the loads in 50s, 30s, 10s, and 2s respectively.

Browse Interface

Press the SELECT button to cycle display the following interfaces:

LCD display showing various parameters like PV input, charging current, power generation, load work mode, battery voltage, battery current, discharge capacity, discharge current, and temperature.
Figure 4-2: LCD Display showing various operational parameters.

4.4 Setting

Primary and Secondary Modes

The Primary mode is used for BMS communication; the Secondary mode is used for RS485 communication and in such mode, battery parameters can be set remotely via PC host computer software or APP software. See “4.4.5 Battery Type - 3. Remote setting the battery parameters” for details. The Primary and Secondary modes are switched as follows:

Press the SELECT button to switch to the first TYPE interface; press the ENTER button and the value will flash; press the SELECT button to switch the mode (“nn” indicates primary controller communication mode, and "S" indicates secondary controller communication mode); press the ENTER button to confirm selection.

BMS Protocol Number

When using lithium batteries with BMS function, after the controller is connected to BMS-Link module and lithium batteries, by setting the BMS protocol number, BMS protocols of different lithium battery manufacturers can be converted into our standard protocols by BMS-Link module so as to realize the communication between the controller and lithium battery BMS of different manufacturers. The BMS protocol number of different lithium batteries can be found on the websites of corresponding companies. Normal communication can only be achieved after the protocol number is properly set. The protocol number is set as follows:

In the Primary mode (the first TYPE interface displays “nn”), press the SELECT button to switch to the second TYPE interface; press the ENTER button to switch to the BMS protocol number (default 01, scope: 0-231); press the SELECT button to confirm selection.

After the controller reads the BMS detection:

  • Make the charging/discharging switch logic control based on BMS detection.
  • Upon reading the available BMS protection voltage, the actual working voltage can be predicted according to the logical relationship, which can be set in the device at that time, but it will not be actually executed; upon the disconnection or invalidity of BMS, the device can work based on the set voltage.
  • After reading the available BMS current limit, current limit charging can be conducted in accordance with BMS current limit and the originally set current limit (whichever is the smaller).

Clear the Generated Energy

Step 1: Press the ENTER button and hold 5s under the PV-generated energy interface, and the value will flash.

Step 2: Press the ENTER button to clear the generated energy.

Switch the Battery Temperature Unit

Press the button and hold for 5s under the battery temperature interface to switch the temperature unit.

Battery Type

1. Supported Battery Types

CategoryTypes
1BatterySealed (default), Gel, FLD
2Lithium batteryLiFePO4 (4S/12V; 8S/24V), Li(NiCoMn)O2 (3S/12V; 6S/24V; 7S/24V)
3UserCustomizable

2. Local Setting of the Battery Type

Step 1: Press the SELECT button to jump to the battery voltage interface.

Step 2: Press and hold the ENTER button until the battery-type interface flashes.

Step 3: Press the SELECT button to change the battery type (e.g., Sealed, Gel, Flooded, LCNM3S, LFP8S, LFP4S, LCNM6S, LCNM7S, User).

Step 4: Press the ENTER button to confirm.

Under the "USE" battery type, the battery parameters can be set via the LCD. The System Voltage Level (SYS) can be modified under the non-lithium "USE" type. If the battery type is Sealed, Gel, FLD before entering the "USE" type, the SYS value can be modified. The SYS value cannot be modified if it is a lithium battery type before entering the "USE" type.

Only the above battery parameters can be set on the local controller. The remaining battery parameters follow the following logic (the voltage level of the 12V system is 1, and the voltage level of the 24V system is 2).

Battery ParametersSealed/Gel/FLD UserLiFePO4 UserLi(NiCoMn)O2 User
Overvoltage Disconnect VoltageBCV + 1.4V * voltage levelBCV + 0.3V * voltage levelBCV + 0.3V * voltage level
Charging Voltage Limit VoltageBCV + 0.6V * voltage levelBCV + 0.1V * voltage levelBCV + 0.1V * voltage level
Overvoltage Recovery VoltageBCV + 0.6V * voltage levelBCV + 0.1V * voltage levelBoost charging voltage
Equalization Charging VoltageBCV + 0.2V * voltage levelBoost charging voltageBoost charging voltage
Bulk Recovery VoltageFCV - 0.6V * voltage levelFCV - 0.6V * voltage levelFCV - 0.1V * voltage level
Undervoltage Alarm Recovery VoltageUVW + 0.2V * voltage levelUVW + 0.2V * voltage levelUVW + 1.7V * voltage level
Undervoltage Alarm VoltageLVD + 0.9V * voltage levelLVD + 0.9V * voltage levelLVD + 1.2V * voltage level
Discharging Voltage Limit VoltageLVD - 0.5V * voltage levelLVD - 0.1V * voltage levelLVD - 0.1V * voltage level

Battery Voltage Parameters (12V/25°C, double values for 24V system)

Voltage Control ParametersSealedGELFLDUser define
Overvoltage Disconnect Voltage16.0V16.0V16.0V9-17V
Charging Voltage Limit Voltage15.0V15.0V15.0V9-15.5V
Overvoltage Recovery Voltage15.0V15.0V15.0V9-15.5V
Equalization Charging Voltage14.6V--14.8V9-15.5V
Bulk Charging Voltage14.4V14.2V14.6V9-15.5V
Float Charging Voltage13.8V13.8V13.8V9-15.5V
Bulk Recovery Voltage13.2V13.2V13.2V9-15.5V
Low Voltage Recovery Voltage12.6V12.6V12.6V9-15.5V
Undervoltage Alarm Recovery Voltage12.2V12.2V12.2V9-15.5V
Undervoltage Alarm Voltage12.0V12.0V12.0V9-15.5V
Low Voltage Disconnect Voltage11.1V11.1V11.1V9-15.5V
Discharging Voltage Limit Voltage10.6V10.6V10.6V9-15.5V
Equalization Charging Time120 minutes--120 minutes0-180 minutes

Lithium Battery Voltage Parameters

Battery ParametersLFP4SUser DefineLFP8SUser Define
Overvoltage Disconnect Voltage14.5V9-17V29.0V18-34V
Charging Voltage Limit Voltage14.3V9-15.5V28.6V18-31V
Overvoltage Recovery Voltage14.3V9-15.5V28.6V18-31V
Equalization Charging Voltage14.2V9-15.5V28.4V18-31V
Bulk Charging Voltage14.2V9-15.5V28.4V18-31V
Float Charging Voltage13.3V9-15.5V26.6V18-31V
Bulk Recovery Voltage13.0V9-15.5V26.0V18-31V
Low Voltage Recovery Voltage12.8V9-15.5V25.6V18-31V
Undervoltage Alarm Recovery Voltage12.2V9-15.5V24.4V18-31V
Undervoltage Alarm Voltage12.0V9-15.5V24.0V18-31V
Low Voltage Disconnect Voltage11.3V9-15.5V22.6V18-31V
Discharging Voltage Limit Voltage11.0V9-15.5V22.0V18-31V

Note: LFP4S is for the 12V system, and LFP8S is for the 24V system.

Battery ParametersLNCM3SUser DefineLNCM6SLNCM7SUser Define
Overvoltage Disconnect Voltage12.8V9-17V25.6V29.8V18-34V
Charging Voltage Limit Voltage12.6V9-15.5V25.2V29.4V18-31V
Overvoltage Recovery Voltage12.5V9-15.5V25.0V29.1V18-31V
Equalization Charging Voltage12.5V9-15.5V25.0V29.1V18-31V
Bulk Charging Voltage12.5V9-15.5V25.0V29.1V18-31V
Float Charging Voltage12.2V9-15.5V24.4V28.4V18-31V
Bulk Recovery Voltage12.1V9-15.5V24.2V28.2V18-31V
Low Voltage Recovery Voltage10.5V9-15.5V21.0V24.5V18-31V
Undervoltage Alarm Recovery Voltage12.2V9-15.5V24.4V28.4V18-31V
Undervoltage Alarm Voltage10.5V9-15.5V21.0V24.5V18-31V
Low Voltage Disconnect Voltage9.3V9-15.5V18.6V21.7V18-31V
Discharging Voltage Limit9.3V9-15.5V18.6V21.7V18-31V

Note: LNCM3S is for the 12V system, LNCM6S and LNCM7S are for the 24V system.

NOTICE:

The required accuracy of BMS is no higher than 0.2V. We will not assume responsibility for the abnormal when the accuracy of BMS is higher than 0.2V.

3. Remote Setting of the Battery Parameters

Before setting the battery parameters, the communication mode should be set as the Secondary mode.

a) Setting the battery parameters by PC software

Connect the controller's RJ45 port to the PC's USB interface via a USB to RS485 cable. When selecting the battery type as "USE," set the voltage parameters by the PC software.

Diagram showing connection of EPEVER controller to PC via USB to RS485 cable.
Figure 4-3: Connecting the controller to a PC for parameter setting.

b) Setting the battery parameters by APP (via external WiFi 2.4G adapter or Bluetooth adapter)

Connect the controller to an external WiFi 2.4G adapter or Bluetooth adapter by the RS485 communication port. End-users can set the voltage parameters by the APP after selecting the battery type as "USE." Refer to the cloud APP manual for details.

4.5 Load Modes

When the LCD shows the load type interface, operate as follows:

Step 1: Press the SELECT button to jump to the load type interface.

Step 2: Press and hold the ENTER button until the load type interface flashes.

Step 3: Press the SELECT button to modify the load type.

Step 4: Press the ENTER button to confirm.

Mode (1**)Timer 1Mode (2**)Timer 2
100 (Light ON/OFF)2 nDisabled
101Load on for 1 hour since sunset201Load on for 1 hour before sunrise
102Load on for 2 hours since sunset202Load on for 2 hours before sunrise
103-113Load on for 3 -13 hours since sunset203-213Load on for 3 -13 hours before sunrise
114Load on for 14 hours since sunset214Load on for 14 hours before sunrise
115Load on for 15 hours since sunset215Load on for 15 hours before sunrise
116 (Test mode)2 nDisabled
117 (Manual mode)Default load ON
118 (Always ON mode)Load always maintains output state, suitable for 24-hour power supply2 nDisabled

Note: When selecting the load mode as the Light ON/OFF mode, Test mode, and Manual mode, only Timer 1 can be set, and Timer 2 is disabled and displays "2n".

Set the load modes by PC software, APP, or remote meter (MT52). For detailed connection diagrams and settings, refer to Subsection 4.4.5 Battery type > 3. Remote setting of the battery parameters.

5. Maintenance

The following inspections and maintenance tasks are recommended at least twice yearly for good performance.

  • Make sure no block on airflow around the controller. Clear up any dirt and fragments on the radiator.
  • Check all naked wires to ensure insulation is not damaged by sun exposure, frictional wear, dryness, insects or rats, etc. Repair or replace some wires if necessary.
  • Verify the indicator display is consistent with the actual operation. Pay attention to any troubleshooting or error conditions. Take necessary corrective action.
  • Confirm that terminals have no corrosion, insulation damaged, high temperature, burnt/discolored sign, and tighten terminal screws to the suggested torque.
  • Clear up dirt, nesting insects, and corrosion in time.
  • Check and confirm that the lightning arrester is in good condition. Replace a new one in time to avoid damaging the controller and other equipment.

DANGER:

Electric shock hazard! Ensure that the power is turned off before the above operations, and then follow the corresponding inspections and operations.

6. Troubleshooting

6.1 Protections

The controller includes various protection mechanisms:

ProtectionInstruction
PV overcurrentWhen the actual PV array's charging current or power is higher than the controller's rated charging current or power, the controller will charge the battery per the rated current or power.
PV short-circuitNot in the PV charging state, the controller will not be damaged when the PV array is short-circuited. Note: It is forbidden to short-circuit the PV array during charging. Otherwise, the controller may be damaged.
PV reverse polarityWhen the polarity of the PV array is reversed, the controller may not be damaged and can continue to operate normally after the polarity is corrected. Note: If the PV array is reversed and its actual power is 1.5 times the controller's rated power, the controller may be damaged.
Night reverse chargingAvoid the battery from discharging to the PV module at night.
Battery reverseThe battery can be reversely connected when the PV is disconnected or reversely connected. Correct the wire connection to resume work. Note: The controller will be damaged when the PV connection is correct and the battery connection is reversed!
Battery overvoltageWhen the battery voltage reaches the overvoltage disconnect voltage, the PV array will automatically stop charging the battery to avoid battery damage.
Battery over-dischargingThe battery discharging is automatically stopped when the battery voltage is lower than the low voltage disconnect voltage.
Battery overheatingThe controller detects the battery temperature through an external temperature sensor. The battery stops working when its temperature exceeds 65°C and resumes work when it is below 55°C.
Lithium battery low temperatureWhen the temperature detected by the optional temperature sensor is lower than the Low-Temperature Protection Threshold (LTPT), the controller will stop charging and discharging automatically. When the detected temperature is higher than the LTPT, the controller will work automatically (The LTPT is 0°C by default and can be set within -40°C to 10°C).
Load short circuitWhen a short circuit occurs on the load side (four times higher than the rated load current), the controller automatically cuts off the output. The output still attempts to resume five times automatically (delay 5s, 10s, 15s, 20s, 25s). To restart, press the Load button, restart the controller, or experience a night-to-day change (night time > 3 hours).
OverloadIf the load current exceeds 1.05 times the controller's rating, the controller will cut off the output after a delay. After the overload occurs, the output attempts to resume automatically five times (delay of 5s, 10s, 15s, 20s, and 25s). To restart, press the Load button, restart the controller, or experience a night-to-day change (night time > 3 hours).
Device overheatingAn internal temperature sensor can detect the internal temperature of the controller. The controller stops working when its internal temperature is higher than 85℃ and resumes working when its internal temperature is below 75℃.
TVS high voltage transientsThe controller's internal circuitry is designed with Transient Voltage Suppressors (TVS), which can only protect against high-voltage surge pulses with less energy. If used in an area with frequent lightning strikes, it is recommended to install an external surge arrester.

Note: When the controller's internal temperature reaches 81 ℃, the charging power automatic reduction function is enabled. Temperature increases by 1℃, and the charging power is reduced by 5%, 10%, 20%, and 40%. If the internal temperature exceeds 85℃, the controller stops charging the battery. When the internal temperature is lower than or equal to 75℃, the controller resumes charging per the rated charging power.

6.2 Troubleshooting Guide

FaultsTroubleshooting
PV array open-circuit (LCD shows solar panel icon with moon)Confirm whether the connection of the PV array is correct and tight.
The battery voltage is lower than 8V.Check the battery's voltage (at least 8V voltage to activate the controller).
Battery overvoltage (Battery frame blink, fault icon blink)Check whether the battery voltage is higher than OVD (overvoltage disconnect voltage) and disconnect the PV array connection.
Battery over-discharged (Battery frame blink, fault icon blink)1. When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover. 2. Take other ways to recharge the battery.
Battery overheating (Battery frame blink, fault icon blink)While the temperature declines below 55°C, the controller will resume.
Overload (Load off, Load and fault icon blink)1. Reduce the number of electric devices. 2. Restart the controller or press the button to clear faults.
Load short-circuit1. Check carefully loads connection, clear the fault. 2. Restart the controller or press the button to clear faults.

7. Technical Specifications

7.1 Electrical Parameters

Product ModelTracer1206AN G3Tracer2206AN G3Tracer1210AN G3Tracer2210AN G3Tracer3210AN G3Tracer4210AN G3
Electrical Parameters
Battery Rated Voltage12/24VDC Auto-recognition
Rated Charging Current10A20A10A20A30A40A
Rated Discharge Current10A20A10A20A30A40A
Controller Work Voltage Range8-31V
PV Maximum Open-circuit Voltage60V (At minimum operating environment temperature)
46V (At 25°C)
100V (At minimum operating environment temperature)
92V (At 25°C)
MPPT Voltage Range(Battery voltage + 2V) to 36V(Battery voltage + 2V) to 72V
Rated Charging Power130W/12V
260W/24V
260W/12V
520W/24V
130W/12V
260W/24V
260W/12V
520W/24V
390W/12V
780W/24V
520W/12V
1040W/24V
Static Losses≤ 8mA (12V)
≤ 5mA (24V)
Discharge-circuit Voltage Drop≤ 0.23V
Temperature Compensation-3mV/°C/2V (Default)
Grounding TypeCommon negative
RS485 Port5VDC/200mA (RJ45)
LCD Backlight TimeDefault: 60s, Range: 0-999s (0s: the backlight is ON all the time)

7.2 Environmental Parameters

ParameterValue
Work Temperature Range-25°C to +45℃ (100% loads working)
Storage Temperature Range-20°C to +70°C
Relative Humidity< 95% (N.C.)
EnclosureIP30

7.3 Mechanical Parameters

ModelTracer1206/1210AN G3Tracer2206/2210AN G3Tracer3210AN G3Tracer4210AN G3
Dimension (L × W × H)172mm × 139mm × 44mm220mm × 154mm × 52mm228mm × 164mm × 55mm252mm × 180mm × 63mm
Mounting Size (L × W)124mm × 130mm170mm × 145mm170mm × 155mm204mm × 171mm
Mounting Hole SizeΦ5mm
Terminal12AWG (4mm²)6AWG (16mm²)6AWG (16mm²)6AWG (16mm²)
Recommended Wire Size12AWG (4mm²)10AWG (6mm²)8AWG (10mm²)6AWG (16mm²)
Net Weight0.57kg0.94kg1.26kg1.65kg

7.4 Conversion Efficiency Curves

The following graphs illustrate the conversion efficiency of various models under different PV array MPP voltages and system voltages.

Tracer1206AN G3

Conversion Efficiency Curves for Tracer1206AN G3 at 13V and 26V system voltages.
Figure 7-1: Conversion Efficiency Curves for Tracer1206AN G3. Top graph shows 13V system voltage with PV array MPP voltage at 17V and 34V. Bottom graph shows 26V system voltage with PV array MPP voltage at 34V and 45V.

Tracer1210AN G3

Conversion Efficiency Curves for Tracer1210AN G3 at 13V and 26V system voltages.
Figure 7-2: Conversion Efficiency Curves for Tracer1210AN G3. Top graph shows 13V system voltage with PV array MPP voltage at 17V and 34V. Bottom graph shows 26V system voltage with PV array MPP voltage at 34V and 45V.

Tracer2206AN G3

Conversion Efficiency Curves for Tracer2206AN G3 at 13V and 26V system voltages.
Figure 7-3: Conversion Efficiency Curves for Tracer2206AN G3. Top graph shows 13V system voltage with PV array MPP voltage at 17V and 34V. Bottom graph shows 26V system voltage with PV array MPP voltage at 34V and 42V.

Tracer2210AN G3

Conversion Efficiency Curves for Tracer2210AN G3 at 13V and 26V system voltages.
Figure 7-4: Conversion Efficiency Curves for Tracer2210AN G3. Top graph shows 13V system voltage with PV array MPP voltage at 17V and 34V. Bottom graph shows 26V system voltage with PV array MPP voltage at 34V, 51V, and 68V.

Tracer3210AN G3

Conversion Efficiency Curves for Tracer3210AN G3 at 13V and 26V system voltages.
Figure 7-5: Conversion Efficiency Curves for Tracer3210AN G3. Top graph shows 13V system voltage with PV array MPP voltage at 17V and 34V. Bottom graph shows 26V system voltage with PV array MPP voltage at 34V, 51V, and 68V.

Tracer4210AN G3

Conversion Efficiency Curves for Tracer4210AN G3 at 13V and 26V system voltages.
Figure 7-6: Conversion Efficiency Curves for Tracer4210AN G3. Top graph shows 13V system voltage with PV array MPP voltage at 17V and 34V. Bottom graph shows 26V system voltage with PV array MPP voltage at 34V, 51V, and 68V.

8. User Tips

No specific user tips were available from provided reviews or Q&A content.

9. Warranty and Support

For warranty information, technical support, or inquiries, please contact EPEVER directly.

HUIZHOU EPEVER TECHNOLOGY CO., LTD.

  • Phone: +86-752-3889706
  • Email: info@epever.com
  • Website: www.epever.com

A detailed user manual in PDF format is available for download from the manufacturer's website or can be accessed via the following link: EPEVER Tracer-AN G3 User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.