1. Introduction
1.1 Overview
Tracer-AN G3 series controllers, based on a new design concept, adopt the solar charge controller as the main component. With optional 4G or Wi-Fi modules, end-users can read and write parameters by phone APP conveniently.
Adopting the advanced MPPT control algorithm, the Tracer-AN solar controller can minimize the maximum power point loss rate and time. This product tracks the PV array's maximum power point and obtains maximum energy under any situation. Compared with the PWM charging method, MPPT solar controllers can increase the energy utilization ratio by 10%-30%. Charging current limit, charging power limit, and high temperature charging automatic power reduction fully ensure system stability when access to excess PV modules and high temperature running. A professional protection chip for the RS485 port further improves reliability and meets different application requirements.
The Tracer-AN series controller owns a self-adaptive three-stage charging mode based on a digital control circuit. It effectively prolongs the battery lifespan and significantly improves the system's performance. These controllers are equipped with comprehensive electronic protections to ensure the solar system is more reliable and durable. This controller can be widely used for RV, household systems, field monitoring, and many other applications.
1.2 Features
- High quality and low failure rate components of ST or IR to ensure service life.
- Advanced MPPT technology, with Max. tracking efficiency higher than 99.5%.
- Advanced MPPT control algorithm to minimize lost rate and lost time.
- Accurate recognizing and tracking technology of multi-peaks maximum power point.
- Wider MPP (maximum power point) running voltage to optimize PV utilization.
- Maximum DC/DC conversion efficiency of 98%.
- Support multi battery types including lithium batteries.
- Equipped with a stable self-activation function for the lithium battery.
- Set the battery voltage parameters on the LCD.
- Battery temperature compensation.
- Limit the charging power & charging current to no higher than the rated value.
- Real-time energy statistics function.
- Charging power reduction automatically for over-temperature.
- RS485 communication interface with optional 4G or Wi-Fi modules for remote monitoring.
- Standard Modbus communication protocol based on the RS485 communication bus, extending the communication distance.
- A power protection chip, which can provide 5VDC/200mA power and over-current, short-circuit protections, is adopted by the communication interface.
- Setting parameters via the PC software, APP, or remote meter.
- Constant voltage output function.
- Comprehensive electronic protections.
- Multiple load work modes.
- Low self-consumption, lower than 10mA.
- Operation at full load without charging power reduced in the working temperature range.
1.3 Naming Rules
The model naming convention for the Tracer-AN G3 series is as follows:
Tracer X Y Z AN G3
- X: Product series (e.g., 4 for 40A, 2 for 20A).
- Y: Rated charging & discharging current (e.g., 1 indicates 10A; 2 indicates 20A; 3 indicates 30A; 4 indicates 40A).
- Z: Battery rated voltage (e.g., 2 indicates 12/24VDC).
- AN: Common negative system.
- G3: The 3rd generation product.
2. Important Safety Instructions
Please keep this manual for future reference.
- Read all instructions and warnings carefully in the manual before installation.
- No user-serviceable components inside the controller. Do not disassemble or attempt to repair the controller.
- Mount the controller indoors. Avoid exposure to components and do not allow water to enter the controller.
- Install the controller in a well-ventilated place. The controller's heat sink may become hot during operation.
- It is suggested to install appropriate external fast-acting fuses/breakers.
- Disconnect PV array connections and the battery's fast-acting fuse/breakers before controller installation and adjustment.
- Power connections must remain tight to avoid excessive heating from a loose connection.
NOTICE:
Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
2.1 Disclaimers
The warranty does not apply to the following conditions:
- Damage caused by improper use or inappropriate environment (such as humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments).
- The actual current/voltage/power exceeds the limit value of the controller.
- Damage caused by working temperature exceeding the rated range.
- Arc, fire, explosion, and other accidents caused by failure to follow the controller stickers or manual instructions.
- Unauthorized dismantling or attempted repair.
- Damage caused by force majeure.
- Damage occurred during transportation or handling.
3. Setup and Installation
3.1 Installation Precautions
- Please read the instructions to familiarize yourself with the installation steps before installation.
- Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
- Be careful when installing the batteries. Please wear eye protection when installing open-type lead-acid batteries and rinse with clean water in time for battery acid contact.
- Keep the battery away from any metal objects, which may cause a short circuit of the battery.
- Acid gas may be generated when the battery is charged. Confirm that the surrounding environment is well ventilated.
- Avoid direct sunlight and rain infiltration when installing it outdoors.
- Loose power connectors and corroded wires may produce high heat that can melt wire insulation, burn surrounding materials, or even cause a fire. Ensure tight connections and secure cables with cable clamps to prevent them from swaying in moving applications.
- Only charge lead-acid and lithium-ion batteries within the control range of this controller.
- The battery connector may be wired to another battery or a bank of batteries. The following instructions refer to a singular battery. Still, it is implied that the battery connection can be made to either one battery or a group of batteries in a battery bank.
- Select the system cables according to 5A/mm² or less current density.
- The wire size of the grounding wire should not be less than 4mm².
- The torque of tightening the wiring screw should not be less than 1.2 N·m.
3.2 Requirements for the PV Array
Serial connection (string) of PV modules
As the core component of the solar system, the controller needs to suit various types of PV modules and maximize solar energy conversion into electricity. According to the open-circuit voltage (VOC) and the maximum power point voltage (VMPP) of the MPPT controller, the serial connection of PV modules suitable for different controllers can be calculated. The below tables are for reference only.
Tracer1206/2206AN G3 PV Array Requirements
| System Voltage | 36-cell (Voc < 23V) | 48-cell (Voc < 31V) | 54-cell (Voc < 34V) | 60-cell (Voc < 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 2 | 2 | 1 | 1 | 1 | 1 | 1 | 1 |
| 24V | 2 | 2 | - | - | - | - | - | - |
| System Voltage | 72-cell (Voc < 46V) | 96-cell (Voc < 62V) | Thin-film Module (Voc > 80V) | ||
|---|---|---|---|---|---|
| Max. | Best | Max. | Best | ||
| 12V | 1 | 1 | - | - | - |
| 24V | 1 | 1 | - | - | - |
Note: The above parameters are calculated under the STC (Standard Test Condition)—temperature at 25°C, air mass 1.5, irradiance 1,000W/m².
Tracer1210/2210/3210/4210AN G3 PV Array Requirements
| System Voltage | 36-cell (Voc < 23V) | 48-cell (Voc < 31V) | 54-cell (Voc < 34V) | 60-cell (Voc < 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 | 2 | 1 | 2 | 1 |
| 24V | 4 | 3 | 2 | 2 | 2 | 2 | 2 | 2 |
| System Voltage | 72-cell (Voc < 46V) | 96-cell (Voc < 62V) | Thin-film Module (Voc > 80V) | ||
|---|---|---|---|---|---|
| Max. | Best | Max. | Best | ||
| 12V | 2 | 1 | 1 | 1 | 1 |
| 24V | 2 | 1 | 1 | 1 | 1 |
Note: The above parameters are calculated under the STC (Standard Test Condition)—temperature at 25°C, air mass 1.5, irradiance 1,000W/m².
NOTICE:
The total voltage must not exceed the PV maximum open-circuit voltage when the PV modules are connected in series. The PV maximum open-circuit voltage is 46V (Tracer**06AN G3) or 92V (Tracer**10AN G3) at 25°C environment temperature.
3.3 Wire Size
The wiring and installation methods conform to national and local electrical code requirements.
PV Wire Size
The PV array's output current varies with size, connection method, and sunlight angle. Its ISC (short circuit current) can calculate the minimum wire size. Please refer to the ISC value in the PV module's specifications. When the PV modules are connected in series, the total ISC equals any PV module's ISC. When the PV modules are connected in parallel, the total ISC equals the sum of the PV module's ISC. The PV array's ISC must not exceed the controller's maximum PV input current. For max. PV input current and max. PV wire size, please refer to the table below:
| Model | Max. PV Input Current | Max. PV Wire Size | Circuit Breaker |
|---|---|---|---|
| Tracer1206/1210AN G3 | 10A | 4mm²/12AWG | 16A/125V/2 P |
| Tracer2206/2210AN G3 | 20A | 6mm²/10AWG | 32A/125V/2 P |
| Tracer3210AN G3 | 30A | 10mm²/8AWG | 40A/125V/2 P |
| Tracer4210AN G3 | 40A | 16mm²/6AWG | 63A/125V/2 P |
Battery and Load Wire Size
The battery and load wire size conform to the rated current, and the reference size is as below:
| Model | Rated Charge Current | Rated Discharge Current | Battery Wire Size | Load Wire Size | Circuit Breaker |
|---|---|---|---|---|---|
| Tracer1206/1210AN G3 | 10A | 10A | 4mm²/12AWG | 4mm²/12AWG | 16A/125V/2 P |
| Tracer2206/2210AN G3 | 20A | 20A | 6mm²/10AWG | 6mm²/10AWG | 32A/125V/2 P |
| Tracer3210AN G3 | 30A | 30A | 10mm²/8AWG | 10mm²/8AWG | 40A/125V/2 P |
| Tracer4210AN G3 | 40A | 40A | 16mm²/6AWG | 16mm²/6AWG | 63A/125V/2 P |
NOTICE:
- The wire size is only for reference. Suppose there is a long distance between the PV array and the controller or between the controller and the battery. In that case, larger wires can be used to reduce the voltage drop and improve performance.
- The recommended wire is selected for the battery according to the conditions that its terminals are not connected to any additional inverter.
3.4 Mounting
DANGER:
- Explosion hazard! Never install the controller in a sealed enclosure with FLD batteries! Do not install the controller in a confined area where battery gas can accumulate.
- Electric shock hazard! The PV array may generate a high open-circuit voltage when wiring the PV modules. Disconnect the breaker or fast-acting fuse first, and be careful when wiring.
The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
Step 1: Determine the installation location and heat-dissipation space.

3.5 Connection Diagram
Step 2: Connect the system in the order of ①battery > ②load > ③PV array by the following schematic wiring diagram, and disconnect the system in the reverse order.

NOTICE:
- Please do not connect the circuit breaker or fast-acting fuse during the wiring and ensure that the electrode polarity is correctly connected.
- A fast-acting fuse whose current is 1.25 to 2 times the controller's rated current must be installed on the battery side with a distance from the battery no longer than 150mm.
- The cable length of the battery should not exceed 3 meters.
- The recommended cable length of the PV array should not exceed 3 meters (Note: If the cable length of the PV array is less than 3 meters, the system meets EN/IEC61000-6-3 requirements. If more than 3 meters, the system may not meet EN/IEC61000-6-3 requirements).
- Suppose the controller is to be used in an area with frequent lightning strikes or an unattended area. In that case, it must install an external surge arrester.
- If an inverter is to be connected to the system, connect the inverter directly to the battery, not to the load side of the controller.
3.6 Grounding
Tracer-AN G3 series are common-negative controllers. Negative terminals of the PV array, the battery, and the load can be grounded simultaneously, or any negative terminal is grounded. However, according to practical application, the negative terminals of the PV array, battery, and load can also be ungrounded. However, the grounding terminal on its shell must be grounded. It shields electromagnetic interference and avoids electric shock to the human body.
NOTICE:
It is recommended to use a common-negative controller for common-negative systems, such as the RV system. The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in the common-negative system.
3.7 Connect Accessories
Connect the temperature sensor

NOTICE:
Suppose the remote temperature sensor is not connected to the controller or is damaged. In that case, the controller will charge or discharge the battery at the default 25 ℃ (no temperature compensation).
Connect the accessories for RS485 communication
Refer to Section 4.3 Setting for details on RS485 communication.
Note: The internal circuit of the RS485 port has no isolation design. Connecting an RS485 communication isolator to the port is recommended before communicating.
3.8 Power On the Controller
Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (the controller operates normally when the indicator is lit green). Connect the fast-acting fuse and circuit breaker of the load and PV array. Then the system will be operating in preprogrammed mode.
Note: If the controller is not operating properly or the battery indicator on the controller shows an abnormality, please refer to Section 6.2 Troubleshooting.
4. Operation
4.1 LCD Display

Note: The display screen can be viewed clearly when the angle between the end-user's horizontal sight and the display screen is within 90°. If the angle exceeds 90°, the information on the display screen cannot be viewed clearly.
4.2 Buttons
| Mode | Note |
|---|---|
| Load ON/OFF | It can turn the load On/Off via the ENTER button in manual load mode. |
| Clear fault | Press the ENTER button. |
| Browsing mode | Press the SELECT button. |
| Setting mode | Press the ENTER button and hold on 5s to enter the setting mode. Press the SELECT button to set the parameters. Press the ENTER button to confirm the setting parameters or no operation for 10s. It will exit the setting interface automatically. |
4.3 Interface
Status Description
The LCD displays various parameters and statuses. Here are some common indicators:
| Name | Icon | Status |
|---|---|---|
| PV | Solar panel icon with sun/moon | Day / Night |
| Solar panel icon with 'No charge' symbol | No charge | |
| Solar panel icon with 'Charging' symbol | Charging | |
| PV | PV icon with voltage/current/energy | PV array's voltage, current, and generated energy |
| BATT. | Battery icon with charge level | Battery capacity, In charging |
| BATT. BATT. TYPE | Battery icon with voltage/current/temp | Battery Voltage, Current, Temperature, Battery type |
| LOAD | Light bulb icon with 'ON' symbol | Load ON |
| Light bulb icon with 'OFF' symbol | Load OFF | |
| LOAD | Load icon with current/energy | Current/Consumed energy/Load mode |
Error Codes
| Status | Icon | Instruction |
|---|---|---|
| Battery over-discharged | Battery icon with empty frame, blinking fault icon | Battery level shows empty, battery frame blink, fault icon blink |
| Battery overvoltage | Battery icon with full frame, blinking fault icon | Battery level shows full, battery frame blink, fault icon blink |
| Battery overheating | Battery icon with current value, blinking fault icon | Battery level shows current value, battery frame blink, fault icon blink |
| Load failure | Light bulb icon with fault symbol | Overload; Load short circuit |
Note: When the load current reaches 1.02-1.05 times, 1.05-1.25 times, 1.25-1.35 times, and 1.35-1.5 times more than the rated value, the controller will automatically turn off the loads in 50s, 30s, 10s, and 2s respectively.
Browse Interface
Press the SELECT button to cycle display the following interfaces:

4.4 Setting
Primary and Secondary Modes
The Primary mode is used for BMS communication; the Secondary mode is used for RS485 communication and in such mode, battery parameters can be set remotely via PC host computer software or APP software. See “4.4.5 Battery Type - 3. Remote setting the battery parameters” for details. The Primary and Secondary modes are switched as follows:
Press the SELECT button to switch to the first TYPE interface; press the ENTER button and the value will flash; press the SELECT button to switch the mode (“nn” indicates primary controller communication mode, and "S" indicates secondary controller communication mode); press the ENTER button to confirm selection.
BMS Protocol Number
When using lithium batteries with BMS function, after the controller is connected to BMS-Link module and lithium batteries, by setting the BMS protocol number, BMS protocols of different lithium battery manufacturers can be converted into our standard protocols by BMS-Link module so as to realize the communication between the controller and lithium battery BMS of different manufacturers. The BMS protocol number of different lithium batteries can be found on the websites of corresponding companies. Normal communication can only be achieved after the protocol number is properly set. The protocol number is set as follows:
In the Primary mode (the first TYPE interface displays “nn”), press the SELECT button to switch to the second TYPE interface; press the ENTER button to switch to the BMS protocol number (default 01, scope: 0-231); press the SELECT button to confirm selection.
After the controller reads the BMS detection:
- Make the charging/discharging switch logic control based on BMS detection.
- Upon reading the available BMS protection voltage, the actual working voltage can be predicted according to the logical relationship, which can be set in the device at that time, but it will not be actually executed; upon the disconnection or invalidity of BMS, the device can work based on the set voltage.
- After reading the available BMS current limit, current limit charging can be conducted in accordance with BMS current limit and the originally set current limit (whichever is the smaller).
Clear the Generated Energy
Step 1: Press the ENTER button and hold 5s under the PV-generated energy interface, and the value will flash.
Step 2: Press the ENTER button to clear the generated energy.
Switch the Battery Temperature Unit
Press the button and hold for 5s under the battery temperature interface to switch the temperature unit.
Battery Type
1. Supported Battery Types
| Category | Types | |
|---|---|---|
| 1 | Battery | Sealed (default), Gel, FLD |
| 2 | Lithium battery | LiFePO4 (4S/12V; 8S/24V), Li(NiCoMn)O2 (3S/12V; 6S/24V; 7S/24V) |
| 3 | User | Customizable |
2. Local Setting of the Battery Type
Step 1: Press the SELECT button to jump to the battery voltage interface.
Step 2: Press and hold the ENTER button until the battery-type interface flashes.
Step 3: Press the SELECT button to change the battery type (e.g., Sealed, Gel, Flooded, LCNM3S, LFP8S, LFP4S, LCNM6S, LCNM7S, User).
Step 4: Press the ENTER button to confirm.
Under the "USE" battery type, the battery parameters can be set via the LCD. The System Voltage Level (SYS) can be modified under the non-lithium "USE" type. If the battery type is Sealed, Gel, FLD before entering the "USE" type, the SYS value can be modified. The SYS value cannot be modified if it is a lithium battery type before entering the "USE" type.
Only the above battery parameters can be set on the local controller. The remaining battery parameters follow the following logic (the voltage level of the 12V system is 1, and the voltage level of the 24V system is 2).
| Battery Parameters | Sealed/Gel/FLD User | LiFePO4 User | Li(NiCoMn)O2 User |
|---|---|---|---|
| Overvoltage Disconnect Voltage | BCV + 1.4V * voltage level | BCV + 0.3V * voltage level | BCV + 0.3V * voltage level |
| Charging Voltage Limit Voltage | BCV + 0.6V * voltage level | BCV + 0.1V * voltage level | BCV + 0.1V * voltage level |
| Overvoltage Recovery Voltage | BCV + 0.6V * voltage level | BCV + 0.1V * voltage level | Boost charging voltage |
| Equalization Charging Voltage | BCV + 0.2V * voltage level | Boost charging voltage | Boost charging voltage |
| Bulk Recovery Voltage | FCV - 0.6V * voltage level | FCV - 0.6V * voltage level | FCV - 0.1V * voltage level |
| Undervoltage Alarm Recovery Voltage | UVW + 0.2V * voltage level | UVW + 0.2V * voltage level | UVW + 1.7V * voltage level |
| Undervoltage Alarm Voltage | LVD + 0.9V * voltage level | LVD + 0.9V * voltage level | LVD + 1.2V * voltage level |
| Discharging Voltage Limit Voltage | LVD - 0.5V * voltage level | LVD - 0.1V * voltage level | LVD - 0.1V * voltage level |
Battery Voltage Parameters (12V/25°C, double values for 24V system)
| Voltage Control Parameters | Sealed | GEL | FLD | User define |
|---|---|---|---|---|
| Overvoltage Disconnect Voltage | 16.0V | 16.0V | 16.0V | 9-17V |
| Charging Voltage Limit Voltage | 15.0V | 15.0V | 15.0V | 9-15.5V |
| Overvoltage Recovery Voltage | 15.0V | 15.0V | 15.0V | 9-15.5V |
| Equalization Charging Voltage | 14.6V | -- | 14.8V | 9-15.5V |
| Bulk Charging Voltage | 14.4V | 14.2V | 14.6V | 9-15.5V |
| Float Charging Voltage | 13.8V | 13.8V | 13.8V | 9-15.5V |
| Bulk Recovery Voltage | 13.2V | 13.2V | 13.2V | 9-15.5V |
| Low Voltage Recovery Voltage | 12.6V | 12.6V | 12.6V | 9-15.5V |
| Undervoltage Alarm Recovery Voltage | 12.2V | 12.2V | 12.2V | 9-15.5V |
| Undervoltage Alarm Voltage | 12.0V | 12.0V | 12.0V | 9-15.5V |
| Low Voltage Disconnect Voltage | 11.1V | 11.1V | 11.1V | 9-15.5V |
| Discharging Voltage Limit Voltage | 10.6V | 10.6V | 10.6V | 9-15.5V |
| Equalization Charging Time | 120 minutes | -- | 120 minutes | 0-180 minutes |
Lithium Battery Voltage Parameters
| Battery Parameters | LFP4S | User Define | LFP8S | User Define |
|---|---|---|---|---|
| Overvoltage Disconnect Voltage | 14.5V | 9-17V | 29.0V | 18-34V |
| Charging Voltage Limit Voltage | 14.3V | 9-15.5V | 28.6V | 18-31V |
| Overvoltage Recovery Voltage | 14.3V | 9-15.5V | 28.6V | 18-31V |
| Equalization Charging Voltage | 14.2V | 9-15.5V | 28.4V | 18-31V |
| Bulk Charging Voltage | 14.2V | 9-15.5V | 28.4V | 18-31V |
| Float Charging Voltage | 13.3V | 9-15.5V | 26.6V | 18-31V |
| Bulk Recovery Voltage | 13.0V | 9-15.5V | 26.0V | 18-31V |
| Low Voltage Recovery Voltage | 12.8V | 9-15.5V | 25.6V | 18-31V |
| Undervoltage Alarm Recovery Voltage | 12.2V | 9-15.5V | 24.4V | 18-31V |
| Undervoltage Alarm Voltage | 12.0V | 9-15.5V | 24.0V | 18-31V |
| Low Voltage Disconnect Voltage | 11.3V | 9-15.5V | 22.6V | 18-31V |
| Discharging Voltage Limit Voltage | 11.0V | 9-15.5V | 22.0V | 18-31V |
Note: LFP4S is for the 12V system, and LFP8S is for the 24V system.
| Battery Parameters | LNCM3S | User Define | LNCM6S | LNCM7S | User Define |
|---|---|---|---|---|---|
| Overvoltage Disconnect Voltage | 12.8V | 9-17V | 25.6V | 29.8V | 18-34V |
| Charging Voltage Limit Voltage | 12.6V | 9-15.5V | 25.2V | 29.4V | 18-31V |
| Overvoltage Recovery Voltage | 12.5V | 9-15.5V | 25.0V | 29.1V | 18-31V |
| Equalization Charging Voltage | 12.5V | 9-15.5V | 25.0V | 29.1V | 18-31V |
| Bulk Charging Voltage | 12.5V | 9-15.5V | 25.0V | 29.1V | 18-31V |
| Float Charging Voltage | 12.2V | 9-15.5V | 24.4V | 28.4V | 18-31V |
| Bulk Recovery Voltage | 12.1V | 9-15.5V | 24.2V | 28.2V | 18-31V |
| Low Voltage Recovery Voltage | 10.5V | 9-15.5V | 21.0V | 24.5V | 18-31V |
| Undervoltage Alarm Recovery Voltage | 12.2V | 9-15.5V | 24.4V | 28.4V | 18-31V |
| Undervoltage Alarm Voltage | 10.5V | 9-15.5V | 21.0V | 24.5V | 18-31V |
| Low Voltage Disconnect Voltage | 9.3V | 9-15.5V | 18.6V | 21.7V | 18-31V |
| Discharging Voltage Limit | 9.3V | 9-15.5V | 18.6V | 21.7V | 18-31V |
Note: LNCM3S is for the 12V system, LNCM6S and LNCM7S are for the 24V system.
NOTICE:
The required accuracy of BMS is no higher than 0.2V. We will not assume responsibility for the abnormal when the accuracy of BMS is higher than 0.2V.
3. Remote Setting of the Battery Parameters
Before setting the battery parameters, the communication mode should be set as the Secondary mode.
a) Setting the battery parameters by PC software
Connect the controller's RJ45 port to the PC's USB interface via a USB to RS485 cable. When selecting the battery type as "USE," set the voltage parameters by the PC software.

b) Setting the battery parameters by APP (via external WiFi 2.4G adapter or Bluetooth adapter)
Connect the controller to an external WiFi 2.4G adapter or Bluetooth adapter by the RS485 communication port. End-users can set the voltage parameters by the APP after selecting the battery type as "USE." Refer to the cloud APP manual for details.
4.5 Load Modes
When the LCD shows the load type interface, operate as follows:
Step 1: Press the SELECT button to jump to the load type interface.
Step 2: Press and hold the ENTER button until the load type interface flashes.
Step 3: Press the SELECT button to modify the load type.
Step 4: Press the ENTER button to confirm.
| Mode (1**) | Timer 1 | Mode (2**) | Timer 2 |
|---|---|---|---|
| 100 (Light ON/OFF) | 2 n | Disabled | |
| 101 | Load on for 1 hour since sunset | 201 | Load on for 1 hour before sunrise |
| 102 | Load on for 2 hours since sunset | 202 | Load on for 2 hours before sunrise |
| 103-113 | Load on for 3 -13 hours since sunset | 203-213 | Load on for 3 -13 hours before sunrise |
| 114 | Load on for 14 hours since sunset | 214 | Load on for 14 hours before sunrise |
| 115 | Load on for 15 hours since sunset | 215 | Load on for 15 hours before sunrise |
| 116 (Test mode) | 2 n | Disabled | |
| 117 (Manual mode) | Default load ON | ||
| 118 (Always ON mode) | Load always maintains output state, suitable for 24-hour power supply | 2 n | Disabled |
Note: When selecting the load mode as the Light ON/OFF mode, Test mode, and Manual mode, only Timer 1 can be set, and Timer 2 is disabled and displays "2n".
Set the load modes by PC software, APP, or remote meter (MT52). For detailed connection diagrams and settings, refer to Subsection 4.4.5 Battery type > 3. Remote setting of the battery parameters.
5. Maintenance
The following inspections and maintenance tasks are recommended at least twice yearly for good performance.
- Make sure no block on airflow around the controller. Clear up any dirt and fragments on the radiator.
- Check all naked wires to ensure insulation is not damaged by sun exposure, frictional wear, dryness, insects or rats, etc. Repair or replace some wires if necessary.
- Verify the indicator display is consistent with the actual operation. Pay attention to any troubleshooting or error conditions. Take necessary corrective action.
- Confirm that terminals have no corrosion, insulation damaged, high temperature, burnt/discolored sign, and tighten terminal screws to the suggested torque.
- Clear up dirt, nesting insects, and corrosion in time.
- Check and confirm that the lightning arrester is in good condition. Replace a new one in time to avoid damaging the controller and other equipment.
DANGER:
Electric shock hazard! Ensure that the power is turned off before the above operations, and then follow the corresponding inspections and operations.
6. Troubleshooting
6.1 Protections
The controller includes various protection mechanisms:
| Protection | Instruction |
|---|---|
| PV overcurrent | When the actual PV array's charging current or power is higher than the controller's rated charging current or power, the controller will charge the battery per the rated current or power. |
| PV short-circuit | Not in the PV charging state, the controller will not be damaged when the PV array is short-circuited. Note: It is forbidden to short-circuit the PV array during charging. Otherwise, the controller may be damaged. |
| PV reverse polarity | When the polarity of the PV array is reversed, the controller may not be damaged and can continue to operate normally after the polarity is corrected. Note: If the PV array is reversed and its actual power is 1.5 times the controller's rated power, the controller may be damaged. |
| Night reverse charging | Avoid the battery from discharging to the PV module at night. |
| Battery reverse | The battery can be reversely connected when the PV is disconnected or reversely connected. Correct the wire connection to resume work. Note: The controller will be damaged when the PV connection is correct and the battery connection is reversed! |
| Battery overvoltage | When the battery voltage reaches the overvoltage disconnect voltage, the PV array will automatically stop charging the battery to avoid battery damage. |
| Battery over-discharging | The battery discharging is automatically stopped when the battery voltage is lower than the low voltage disconnect voltage. |
| Battery overheating | The controller detects the battery temperature through an external temperature sensor. The battery stops working when its temperature exceeds 65°C and resumes work when it is below 55°C. |
| Lithium battery low temperature | When the temperature detected by the optional temperature sensor is lower than the Low-Temperature Protection Threshold (LTPT), the controller will stop charging and discharging automatically. When the detected temperature is higher than the LTPT, the controller will work automatically (The LTPT is 0°C by default and can be set within -40°C to 10°C). |
| Load short circuit | When a short circuit occurs on the load side (four times higher than the rated load current), the controller automatically cuts off the output. The output still attempts to resume five times automatically (delay 5s, 10s, 15s, 20s, 25s). To restart, press the Load button, restart the controller, or experience a night-to-day change (night time > 3 hours). |
| Overload | If the load current exceeds 1.05 times the controller's rating, the controller will cut off the output after a delay. After the overload occurs, the output attempts to resume automatically five times (delay of 5s, 10s, 15s, 20s, and 25s). To restart, press the Load button, restart the controller, or experience a night-to-day change (night time > 3 hours). |
| Device overheating | An internal temperature sensor can detect the internal temperature of the controller. The controller stops working when its internal temperature is higher than 85℃ and resumes working when its internal temperature is below 75℃. |
| TVS high voltage transients | The controller's internal circuitry is designed with Transient Voltage Suppressors (TVS), which can only protect against high-voltage surge pulses with less energy. If used in an area with frequent lightning strikes, it is recommended to install an external surge arrester. |
Note: When the controller's internal temperature reaches 81 ℃, the charging power automatic reduction function is enabled. Temperature increases by 1℃, and the charging power is reduced by 5%, 10%, 20%, and 40%. If the internal temperature exceeds 85℃, the controller stops charging the battery. When the internal temperature is lower than or equal to 75℃, the controller resumes charging per the rated charging power.
6.2 Troubleshooting Guide
| Faults | Troubleshooting |
|---|---|
| PV array open-circuit (LCD shows solar panel icon with moon) | Confirm whether the connection of the PV array is correct and tight. |
| The battery voltage is lower than 8V. | Check the battery's voltage (at least 8V voltage to activate the controller). |
| Battery overvoltage (Battery frame blink, fault icon blink) | Check whether the battery voltage is higher than OVD (overvoltage disconnect voltage) and disconnect the PV array connection. |
| Battery over-discharged (Battery frame blink, fault icon blink) | 1. When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover. 2. Take other ways to recharge the battery. |
| Battery overheating (Battery frame blink, fault icon blink) | While the temperature declines below 55°C, the controller will resume. |
| Overload (Load off, Load and fault icon blink) | 1. Reduce the number of electric devices. 2. Restart the controller or press the button to clear faults. |
| Load short-circuit | 1. Check carefully loads connection, clear the fault. 2. Restart the controller or press the button to clear faults. |
7. Technical Specifications
7.1 Electrical Parameters
| Product Model | Tracer1206AN G3 | Tracer2206AN G3 | Tracer1210AN G3 | Tracer2210AN G3 | Tracer3210AN G3 | Tracer4210AN G3 |
|---|---|---|---|---|---|---|
| Electrical Parameters | ||||||
| Battery Rated Voltage | 12/24VDC Auto-recognition | |||||
| Rated Charging Current | 10A | 20A | 10A | 20A | 30A | 40A |
| Rated Discharge Current | 10A | 20A | 10A | 20A | 30A | 40A |
| Controller Work Voltage Range | 8-31V | |||||
| PV Maximum Open-circuit Voltage | 60V (At minimum operating environment temperature) 46V (At 25°C) | 100V (At minimum operating environment temperature) 92V (At 25°C) | ||||
| MPPT Voltage Range | (Battery voltage + 2V) to 36V | (Battery voltage + 2V) to 72V | ||||
| Rated Charging Power | 130W/12V 260W/24V | 260W/12V 520W/24V | 130W/12V 260W/24V | 260W/12V 520W/24V | 390W/12V 780W/24V | 520W/12V 1040W/24V |
| Static Losses | ≤ 8mA (12V) ≤ 5mA (24V) | |||||
| Discharge-circuit Voltage Drop | ≤ 0.23V | |||||
| Temperature Compensation | -3mV/°C/2V (Default) | |||||
| Grounding Type | Common negative | |||||
| RS485 Port | 5VDC/200mA (RJ45) | |||||
| LCD Backlight Time | Default: 60s, Range: 0-999s (0s: the backlight is ON all the time) | |||||
7.2 Environmental Parameters
| Parameter | Value |
|---|---|
| Work Temperature Range | -25°C to +45℃ (100% loads working) |
| Storage Temperature Range | -20°C to +70°C |
| Relative Humidity | < 95% (N.C.) |
| Enclosure | IP30 |
7.3 Mechanical Parameters
| Model | Tracer1206/1210AN G3 | Tracer2206/2210AN G3 | Tracer3210AN G3 | Tracer4210AN G3 |
|---|---|---|---|---|
| Dimension (L × W × H) | 172mm × 139mm × 44mm | 220mm × 154mm × 52mm | 228mm × 164mm × 55mm | 252mm × 180mm × 63mm |
| Mounting Size (L × W) | 124mm × 130mm | 170mm × 145mm | 170mm × 155mm | 204mm × 171mm |
| Mounting Hole Size | Φ5mm | |||
| Terminal | 12AWG (4mm²) | 6AWG (16mm²) | 6AWG (16mm²) | 6AWG (16mm²) |
| Recommended Wire Size | 12AWG (4mm²) | 10AWG (6mm²) | 8AWG (10mm²) | 6AWG (16mm²) |
| Net Weight | 0.57kg | 0.94kg | 1.26kg | 1.65kg |
7.4 Conversion Efficiency Curves
The following graphs illustrate the conversion efficiency of various models under different PV array MPP voltages and system voltages.
Tracer1206AN G3

Tracer1210AN G3

Tracer2206AN G3

Tracer2210AN G3

Tracer3210AN G3

Tracer4210AN G3

8. User Tips
No specific user tips were available from provided reviews or Q&A content.