1. Introduction and Overview
The EPEVER Tracer-AN series MPPT solar charge controllers are designed with multiphase synchronous rectification technology (MSRT) and an advanced MPPT control algorithm. These controllers feature a dual-core processor and co-negative design, ensuring fast response, high reliability, and industrial standards. MSRT guarantees high conversion efficiency across all charging power levels, significantly improving the solar system's energy efficiency. The optimized MPPT tracking technology quickly identifies the PV array's maximum power point in any situation, maximizing energy harvest in real-time.
The automatic power reduction function ensures safe operation even with excess PV modules and during high-temperature conditions. The Tracer-AN series controllers utilize a self-adaptive three-stage charging mode based on a digital control circuit, which effectively prolongs battery lifespan and enhances system performance.
These controllers are suitable for various applications, including solar RVs, household systems, and field monitoring. They support both lead-acid and lithium batteries.


Key Features:
- Complies with IEC62109-1 and EN61000-6-1/3 standard certification.
- High-quality components (ST or IR) for extended service life.
- MPPT tracking efficiency no less than 99.5%.
- Maximum DC/DC transfer efficiency up to 98.6%; full load efficiency up to 98%.
- Accurate recognition and tracking of multi-peak maximum power points.
- Wider MPP running voltage for increased PV module utilization.
- Supports lead-acid and lithium batteries.
- Programmable temperature compensation for batteries.
- Real-time energy statistics function.
- High-temperature charging automatic power reduction function.
- 100% charging and discharging within the working environment temperature range.
- Supports up to 6 controllers connected in parallel.
- Load dry contact to control external load switch.
- Isolated RS485 communication ports (Modbus protocol) with 5V/200mA power supply and short circuit protection.
- Supports remote monitoring and parameter setting via APP or PC software.
2. Important Safety Instructions
Please read and retain this manual for future reference. This manual contains all safety, installation, and operation instructions for the Tracer-AN series MPPT solar controller.
- Read all instructions and warnings carefully before installation.
- The controller contains no user-serviceable components; do not disassemble or attempt repairs.
- Mount the controller indoors. Avoid exposure to components and prevent water ingress.
- Install the controller in a well-ventilated area; the heat sink may become hot during operation.
- Install appropriate external fuses/breakers.
- Disconnect all PV array connections and battery fuses/breakers before controller installation and adjustment.
- Power connections must remain tight to prevent excessive heating from loose connections.
- The entire system should be installed by professional and technical personnel.
Explanation of Symbols:
| Symbol | Definition |
|---|---|
| TIP | Indicates practical advice for reference. |
| ! | IMPORTANT: Indicates a critical tip during operation; ignoring it may cause device error. |
| ⚠ | CAUTION: Indicates potential hazards that may damage the device if not avoided. |
| ⚡ | WARNING: Indicates danger of electric shock; if not avoided, would cause casualties. |
| 🔥 | WARNING HOT SURFACE: Indicates risk of high temperature; if not avoided, would cause scalds. |
| 📖 | Read the user manual carefully before any operation. |
3. Installation
3.1 Attentions:
- Exercise extreme caution when installing batteries. Wear eye protection when handling open-type lead-acid batteries and rinse with clean water immediately if battery acid contact occurs.
- Keep batteries away from metal objects to prevent short circuits.
- Ensure adequate ventilation as acid gas may be generated when batteries are charged.
- Avoid direct sunlight and rain infiltration if installing outdoors.
- Loose power connections or corroded wires can generate high heat, potentially melting wire insulation, burning surrounding materials, or causing a fire. Ensure tight connections and secure cables with clamps to prevent movement.
- Only charge lead-acid and lithium-ion batteries within the controller's specified control range.
- The battery connector can be wired to a single battery or a bank of batteries.
- Select system cables with a current density of 5A/mm² or less.
3.2 Product Characteristics and Ports:

| No. | Description | No. | Description |
|---|---|---|---|
| 1 | Charging LED indicator | 10 | Utility/Generator relay ON |
| 2 | SELECT button | 11 | RBVS Port |
| 3 | Fuse | 12 | Load control relay |
| 4 | Grounding Terminal | 13 | Utility/Generator relay OFF |
| 5 | Cover screw holes M4 | 14 | PV Terminals |
| 6 | PV reverse polarity alarm indicator | 15 | Battery Terminals |
| 7 | Generator and load relay enable | 16 | ENTER button |
| 8 | RTS Port | 17 | LCD |
| 9 | RS485 port (5VDC/200mA) | 18 | Fault LED indicator |
3.3 Requirements for the PV Array:
The controller needs to suit various PV modules and maximize solar energy conversion. The serial connection (string) of PV modules should be calculated based on the open-circuit voltage (VOC) and maximum power point voltage (VMPP) of the MPPT controller. The following tables provide reference values for Tracer6415AN.
| Tracer5415/6415/8415/10415AN - PV Module Configuration (Voc < 31V) | ||||
|---|---|---|---|---|
| System voltage | 36cell (Voc< 23V) | 48cell (Voc< 31V) | ||
| Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 |
| 24V | 6 | 3 | 4 | 2 |
| 48V | 6 | 5 | 4 | 3 |
Note: Parameters are calculated under standard test conditions (STC: Module Temperature 25°C, Air Mass 1.5, Irradiance 1000W/m²).
3.4 Wire Size:
Wiring and installation must conform to national and local electrical code requirements.
PV Wire Size:
The PV array's output current varies. The total ISC (short circuit current) for series-connected modules equals any single module's ISC. For parallel-connected modules, it's the sum of all module ISCs. The PV array's ISC must not exceed the controller's maximum PV input current.
| Model | Max. PV input current | Max. PV wire size |
|---|---|---|
| Tracer6415AN | 60A | 16mm²/6AWG |
CAUTION: The total voltage must not exceed the maximum when PV modules are connected in series. PV open circuit voltage (Tracer**15AN)/180V at 25°C environment temperature.
Battery Wire Size:
The battery wire size must conform to the rated current.
| Model | Rated charging current | Battery wire size |
|---|---|---|
| Tracer6415AN | 60A | 16mm²/6AWG |
CAUTION: Wire size is for reference. For long distances between PV array/controller or controller/battery, use larger wires to reduce voltage drop. Recommended battery wire terminals should not be connected to an additional inverter.
3.5 Dry Contact Instruction:
Dry contact parameter: Rated Value: 5A/30VDC, Maximum Value: 0.5A/60VDC.
Control Utility/Generator ON/OFF:
- Utility/Generator start-up Voltage (VON) = Under Voltage Warning Voltage.
- Utility/Generator stop Voltage (VOFF) = Under Voltage Warning Recover Voltage.
- Start-up: VBAT < VON.
- Stop: VBAT > VOFF.
CAUTION: Set the (Generator/Load) dry contact enable switch to ON. VON and VOFF can be set via PC software.
Control Load Disconnection:
- (Utility/Generator) dry contact OFF interface controls the load's first disconnection (VBAT ≤ VUVW) and first connection (VBAT ≥ VUVWR).
- (Load) dry contact controls the load's second disconnection (VBAT ≤ VLVD) and second connection (VBAT ≥ VLVR).


3.6 Mounting:
Step 1: Determine Installation Location and Heat-Dissipation Space
- Ensure at least 150mm clearance above and below the controller for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
- WARNING: Risk of explosion! Never install the controller in a sealed enclosure with flooded batteries. Do not install in a confined area where battery gas can accumulate.
- WARNING: Risk of electric shock! Disconnect the breaker before wiring solar modules due to high open-circuit voltage.
- CAUTION: Tracer-AN series controllers have no battery reverse protection. Do not reverse battery wiring to avoid damage.
Step 2: Remove the Terminal Protective Cover
Carefully remove the cover before proceeding with wiring.
Step 3: Connect the Battery (Left) and PV (Right)
- Disconnect the system in reverse order.
- WARNING: Tracer-AN series controllers have no battery reverse protection. Do not reverse the battery during wiring.
- CAUTION: Do not connect the circuit breaker or fuse during wiring. Ensure correct electrode polarity. A fuse (1.25 to 2 times controller's rated current) must be installed on the battery side, no more than 150mm from the battery. Connect the inverter directly to the battery, not the controller's load side.
Step 4: Grounding
Tracer-AN series are common-negative controllers. Negative terminals of the PV array and battery can be grounded simultaneously, or any terminal can be grounded. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.
Step 5: Connect Accessories
- Remote Temperature Sensor (Model: RTS300R47K3.81A): Connect to the RTS interface and place the other end near the battery. If not connected, the controller charges/discharges at a default 25°C.
- Remote Battery Voltage Sensor (Model: RVBS300B3.81): Connect to the RBVS interface and the other end to the battery terminals for accurate voltage detection.
- Connect RS485 communication accessories as per the accessories list.
Step 6: Power on the Controller
Connect the battery fuse to power the controller. Once the LCD displays normally, connect the PV array's circuit breaker. The charging indicator will slow flash during PV charging.
CAUTION: If the controller does not work properly or the fault indicator shows an abnormality, refer to the Troubleshooting section.
4. Operation
The display screen is best viewed when the angle between the user's horizontal sight and the screen is within 90°. If the angle exceeds 90°, the information may not be clearly visible.
4.1 Indicator:
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| PV Array | Green | ON solid | PV charges the battery with a low current |
| Green | OFF | 1. No sunlight 2. Connection error 3. Low PV voltage | |
| Green | Slowly flashing (1Hz) | Normal charging | |
| Green | Fast flashing (4Hz) | PV over voltage |
IMPORTANT: The fault indicator refers to the LCD Display section.
4.2 Buttons:
| Modes | Note |
|---|---|
| (Load) dry contact | In manual mode, short-press the "ENTER" button to turn on/off the (Load) dry contact. |
| Clear fault | Press the "ENTER" button. |
| Browsing mode | Short-press the "SELECT" button. |
| Setting mode | Long-press the "ENTER" button to enter Setting mode. Short-press "SELECT" to modify parameter. Short-press "ENTER" to confirm or exit automatically after 10S. |
4.3 LCD Display:
Status Description:
| Name | Symbol | Status |
|---|---|---|
| PV array | ☀️ | Day |
| 🌙 | Night | |
| No charge | ||
| Charging | ||
| PV | PV array's voltage, current, and generated energy | |
| Battery capacity, In Charging | ||
| Battery | BATT. | Battery Voltage, Current, Temperature |
| BATT. TYPE | Battery type | |
| Load | 💡 | (Load) dry contact connected |
| (Load) dry contact disconnected |
Browse Interface:
The LCD browse interface cycles through various parameters like PV voltage, current, battery voltage, temperature, and load status. When there is no operation, the display automatically cycles through all interfaces except for load time 1 and load time 2.
4.4 Error Codes:
| Status | Faults Indicator | Charging Indicator | Symbol | Instruction |
|---|---|---|---|---|
| Battery over discharged | Red ON solid | -- | ⚠ | Battery level shows empty, battery frame blink, fault icon blink. |
| Battery over voltage | Red Slow flashing | -- | ⚠ | Battery level shows full, battery frame blink, fault icon blink. |
| Battery over heating | Red slowly flashing | -- | ⚠ | Battery level shows current value, battery frame blink, and fault icon blink. |
| Controller over temperature | Red slowly flashing | Green slowly flashing | ⚠ | Battery level shows current value, battery frame blink, and fault icon blink. |
| System voltage error | Red slowly flashing | Fast flashing in green | ⚠ | Battery level shows current value, battery frame blink, and fault icon blink. |
5. Settings
5.1 Clear Generated Energy:
In the PV power interface, long-press the "ENTER" button until the value flashes. Then, press "ENTER" again to confirm and reset.
5.2 Switch Battery Temperature Unit:
In the battery temperature interface, long-press the "ENTER" button to switch the unit.
5.3 Battery Type:
Supported Battery Types:
| Battery Type | Options |
|---|---|
| Lead-acid battery | Sealed (default) |
| Gel | |
| Flooded | |
| User | |
| Lithium battery | LiFePO4 (4S/12V; 8S/24V; 15S/48V; 16S/48V) |
| Li(NiCoMn)O2 (3S/12V; 6S/24V; 7S/24V; 13S/48V; 14S/48V) | |
| User |
Note: To modify the battery type to LiFePO4 or Li(NiCoMn)O2, select "User" battery type.
Set Battery Type via LCD:
On the battery voltage interface, long-press "ENTER" until the battery type interface flashes. Press "SELECT" to change the type, then "ENTER" to confirm.
CAUTION: The controller can only set lead-acid battery types via LCD. Lithium battery types must be set via PC or APP software.
Set Battery Type via PC Software or APP Software:
- PC Software: Connect the controller to a PC via USB to RS485 converter. Refer to the cloud platform manual for specific settings.
- APP Software: Connect the controller to a WIFI or Bluetooth module via a standard network cable. The mobile APP sets parameters via WIFI or Bluetooth signal. Refer to the cloud APP manual for specific settings.

Battery Voltage Control Parameters (Lead-acid battery):
Parameters are measured at 12V/25°C. Double values for 24V systems, quadruple for 48V systems.
| Voltage control parameters | Sealed | GEL | FLD | User |
|---|---|---|---|---|
| Over voltage disconnect voltage | 16.0V | 16.0V | 16.0V | 9~17V |
| Charging limit voltage | 15.0V | 15.0V | 15.0V | 9~17V |
| Over voltage reconnect voltage | 15.0V | 15.0V | 15.0V | 9~17V |
| Equalize charging voltage | 14.6V | -- | 14.8V | 9~17V |
| Boost charging voltage | 14.4V | 14.2V | 14.6V | 9~17V |
| Float charging voltage | 13.8V | 13.8V | 13.8V | 9~17V |
| Boost reconnect charging voltage | 13.2V | 13.2V | 13.2V | 9~17V |
| Low voltage reconnect voltage | 12.6V | 12.6V | 12.6V | 9~17V |
| Under voltage warning reconnect voltage | 12.2V | 12.2V | 12.2V | 9~17V |
| Under voltage warning voltage | 12.0V | 12.0V | 12.0V | 9~17V |
| Low voltage disconnect voltage | 11.1V | 11.1V | 11.1V | 9~17V |
| Discharging limit voltage | 10.6V | 10.6V | 10.6V | 9~17V |
| Equalize Duration | 120 minutes | -- | 120 minutes | 0~180 minutes |
| Boost Duration | 120 minutes | 120 minutes | 120 minutes | 10~180 minutes |
To change these parameters, select "User" battery type. Observe the following rules when modifying parameters for user battery type (factory default is sealed type):
- Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage.
- Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage.
- Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.
- Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥ Discharging Limit Voltage.
- Boost Reconnect Charging voltage > Low Voltage Reconnect Voltage.
Lithium Battery Parameters:
Parameters are measured at 12V/25°C. Double values for 24V systems, quadruple for 48V systems.
| Voltage control parameters | LFP | Li(NiCoMn)O2 | User |
|---|---|---|---|
| Over voltage disconnect voltage | 15.6V | 13.5V | 9~17V |
| Charging limit voltage | 14.6V | 12.6V | 9~17V |
| Over voltage reconnect voltage | 14.7V | 12.7V | 9~17V |
| Equalize charging voltage | 14.5V | 12.5V | 9~17V |
| Boost charging voltage | 14.5V | 12.5V | 9~17V |
| Float charging voltage | 13.8V | 12.2V | 9~17V |
| Boost reconnect charging voltage | 13.2V | 12.1V | 9~17V |
| Low voltage reconnect voltage | 12.8V | 10.5V | 9~17V |
| Under voltage warning reconnect voltage | 12.8V | 11.0V | 9~17V |
| Under voltage warning voltage | 12.0V | 10.5V | 9~17V |
| Low voltage disconnect voltage | 11.1V | 9.3V | 9~17V |
| Discharging limit voltage | 10.6V | 9.3V | 9~17V |
Rules for modifying parameters for a user-defined lithium battery:
- Over Voltage Disconnect Voltage > Over Charging Protection Voltage (BMS) + 0.2V.
- Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage > Charging Limit Voltage ≥ Equalize Charging Voltage = Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect Charging Voltage.
- Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging Limit Voltage.
- Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥ Discharging Limit Voltage.
- Boost Reconnect Charging voltage > Low Voltage Reconnect Voltage.
- Low Voltage Disconnect Voltage ≥ Over Discharging Protection Voltage (BMS) + 0.2V.
WARNING: Voltage parameters for a lithium battery can be set according to the battery BMS's voltage parameters. The required accuracy of BMS shall be no higher than 0.2V. The manufacturer is not responsible for system abnormalities if BMS accuracy is higher than 0.2V.
6. Protections
| Protections | Instruction |
|---|---|
| PV current/power-limiting protection | When PV array's actual charging current or power exceeds rated values, the controller charges the battery as per the rated current or power. |
| PV short-circuit protection | Controller will not be damaged if PV array short-circuits when not in PV charging state. WARNING: Do not short-circuit PV array during charging to avoid damage. |
| PV reverse polarity protection | Controller may not be damaged and resumes work after correcting mis-wiring. CAUTION: If PV array is reversed and its actual power is 1.5 times the controller's rated power, the controller may be damaged. |
| Night reverse charging protection | Prevents battery from discharging to the PV module at night. |
| Battery over voltage protection | When battery voltage reaches over voltage disconnect voltage, PV array stops charging to prevent battery damage from overcharging. |
| Battery over discharging protection | When battery voltage reaches low voltage disconnect voltage, battery discharging automatically stops. CAUTION: When battery connects with a load via controller's (Load) dry contact, over-discharge protection takes effect. |
| Battery over heating protection | Controller detects battery temperature via external sensor. Battery stops working if temperature exceeds 65°C and resumes below 55°C. |
| Lithium battery low temperature protection | If temperature detected by optional sensor is lower than Low Temperature Protection Threshold (LTPT), controller stops charging/discharging. Resumes when temperature exceeds LTPT. (LTPT default 0°C, settable 10°C to -40°C). |
| Controller Overheating | Internal sensor detects temperature. Controller stops working if internal temperature exceeds 85°C and resumes below 75°C. When internal temperature is 81°C, power charging reduces by 5%, 10%, 20%, 40% for every 1°C increase. |
| TVS high voltage transients protection | Internal circuitry has TVS for protection against high-voltage surge pulses with less energy. For areas with frequent lightning, an external surge arrester is recommended. |
7. Troubleshooting
| Faults | Solutions |
|---|---|
| Charging LED is OFF during daytime when sunshine falls on PV array properly | Confirm whether the connection of the PV array is correct and tight (PV array open-circuit). |
| The wire connection is correct; the controller is not working. | The battery voltage is lower than 8V. Check battery voltage (at least 8V to activate controller). |
| Battery frame blink, fault icon blink | Battery over voltage. Check if battery voltage is higher than OVD (over voltage disconnect voltage) and disconnect the PV array connection. |
| Battery over discharged. ① When battery voltage is restored to or above LVR (low voltage reconnect voltage), the load recovers. ② Other ways to recharge the battery. | |
| Battery over heating. While battery temperature declines to 55°C or below, the controller resumes work. |
8. Maintenance
The following inspections and maintenance tasks are recommended at least twice yearly for optimal performance:
- Ensure no obstructions block airflow around the controller. Clean any dirt and fragments from the radiator.
- Check all exposed wires for insulation damage (sun exposure, frictional wear, dryness, insects, rats, etc.). Repair or replace damaged wires as necessary.
- Verify that the LED indicators are consistent with expected behavior. Address any troubleshooting or error indications promptly.
- Confirm that all terminals are free from corrosion, insulation damage, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
- Clean any dirt, nesting insects, and corrosion in time.
- Check and confirm that the lightning arrester is in good condition. Replace if necessary to prevent damage to the controller and other equipment.
WARNING: Risk of electric shock! Ensure all power is turned off before performing maintenance operations, then follow corresponding inspections and operations.
9. Specifications (Tracer6415AN)
| Electrical Parameters | |
|---|---|
| System rated voltage | 12/24/36/48VDC or Auto |
| Controller working voltage range | 8V ~ 68V |
| Lead-acid battery type | Sealed (Default) / Gel / Flooded / User |
| Lithium battery type | LiFePO4 / Li(NiCoMn)O2 / User |
| Battery fuse | 80A/58V |
| Rated charging current | 60A |
| Rated charging power | 750W/12V, 1500W/24V, 2250W/36V, 3000W/48V |
| Max. PV open-circuit voltage | 150V (at lowest temperature), 138V (at 25°C) |
| MPPT voltage range | (Battery voltage +2V) ~ 108V (at 25°C) |
| MPPT tracking efficiency | ≥99.5% |
| Max. conversion efficiency | 98.3% |
| Full load efficiency | 97.8% |
| Temperature compensate coefficient | -3mV/°C/2V (Default) |
| Self-consumption | 98mA/12V, 60mA/24V, 50mA/36V, 46mA/48V |
| Grounding | Common negative grounding |
| Dry contact | Rated value: 5A/30VDC, Max. value: 0.5A/60VDC |
| Communication method | RS485 (5VDC/200mA, Two RJ45 ports in parallel) |
| LCD backlight time | Default: 60S, Range: 0~999S (0S: backlight ON all the time) |
| Mechanical Parameters | |
| Dimension (L x W x H) | 261×216×119mm |
| Mounting size (L x W) | 180×204mm |
| Mounting hole size | Φ7mm |
| Wire size | 6AWG/16mm² |
| Recommended cable | 6AWG/16mm² |
| Net Weight | 3.5kg |
| Environmental Parameters | |
| Environment temperature | -25°C~+60°C (charging/load power reduced above 45°C; full load not supported) |
| LCD temperature range | -20°C ~ +70°C |
| Storage temperature | -30°C ~ +85°C |
| Relative humidity range | 5%~95% (N.C.) |
| Enclosure | IP20 |
| Pollution degree | PD2 |
Note: When connecting the controller to external devices, only one of the communication ports is used. When connecting multiple controllers in parallel, RS485 ports are for cascaded use.
9.1 Dimensions (Tracer5415/5420AN):

10. User Tips
- For optimal performance, ensure all wiring connections are secure and properly sized for the current load. Loose connections can lead to efficiency loss and potential hazards.
- Regularly check the controller's display for any error codes or abnormal indicators. Addressing these promptly can prevent system issues.
- When setting up battery parameters, especially for lithium batteries, use the PC or APP software for precise configuration to match your battery's BMS specifications.
- Maintain good ventilation around the controller to prevent overheating, which can reduce charging efficiency and shorten the device's lifespan.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.
A detailed user manual in PDF format is available for download from the manufacturer's website: EPEVER MPPT Solar Charge Controller User Manual (PDF)