1. Product Overview
The Relfar FWH20-S10C V4 is an intelligent single pendulum handheld laser welding head designed for versatile applications including welding, cutting, and cleaning. This 4-in-1 weld gun replaces older models FWH20-S10A and FWH20-S10B, offering enhanced functionality and control.

1.1 Product Structure

1.2 Cautions
To ensure personal safety, please wear special fiber laser protective glasses before operation. Keep the product clean and stop the entry into the cavity of cooling liquid, condensate water, and other objects, otherwise, the function may be impacted.
2. Specifications
The following table details the technical specifications of the FWH20-S10C V4 welding head:

| Name | Intelligent single pendulum handheld welding head |
|---|---|
| Model | FWH20-S10C-V4 |
| Fiber interface | QBH |
| Wavelength range | 1070 ± 20nm |
| Rated power | ≤3000W |
| Collimating focal length | 50mm |
| Focus length | 150mm |
| Focus adjustment range | -10mm ~ +10mm |
| Spot adjustment range | 0 ~ 5mm |
| Auxiliary gas pressure | ≤1Mpa |
| Weight | 0.72Kg |
Additional properties:
- High-concerned chemical: None
- Material: Stainless steel
- Type: Hand Tool Parts
- Origin: Mainland China
3. Setup
3.1 Tube Connection
Cooling pipe and auxiliary gas pipe are connected as shown in the diagram. Compressed used gas: Argon, Nitrogen and compressed air. It's necessary to filter oil and water.

3.2 Fiber Input Installation
Put QBH horizontally and take out the dust seal cover. Align the red point on the optical fiber head with that in QBH, and insert the optical fiber head into QBH slowly.

3.3 System Wiring
The following figure is a schematic diagram for wiring of the whole system. Refer to relevant chapters for detailed interface definition.

3.3.1 CN1 Wire Feeder Interface
The interface CN1 of the wire feeding machine is an 8-pin green terminal, which supports both motor wire feeding and IO wire feeding. The table below shows the definition of the wire feeding machine interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | Pulse+ | Motor wire feed pulse + interface | The motor wire feed is used, and the driver PUL+ is connected |
| 2 | Pulse- | Motor wire feed pulse - interface | Motor wire use, connected to drive PUL- |
| 3 | DIR+ | Motor wire feed direction + interface | Motor wire wire, connected to driver Dir + |
| 4 | DIR- | Motor wire feed direction - interface | Motor wire used, connected to drive Dir- |
| 5 | GND | Reference ground | — |
3.3.2 CN2 Laser Interface
The laser interface is a 8PIN green terminal. The table below shows the definition of laser interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | PWM+ | Modulated signal + | Duty cycle adjustable from 1% to 99%, 24V level |
| 2 | PWM- | Modulated signal- | Duty cycle adjustable from 1% to 99%, 24V level |
| 3 | DA | Simulated voltage output | 0-10V analog voltage, used for adjusting the peak power of the laser |
| 4 | GND | Power reference ground | Generally, it connects to the laser control interface DA- |
| 5 | OVCC | +24V power output | Power supply, capable of delivering a maximum output of 500mA |
| 6 | Enable | Laser enable signal | 24V voltage level, with high level as the valid state |
| 7 | Alarm_in | Laser failure alarm input | — |
| 8 | GATE | Red light indication signal | 24V voltage level, with low level as the active state |
| 9 | GND | Signal reference ground | — |
| 10 | GND | Signal reference ground | — |
3.3.3 CN3 Temperature Sensor Interface
The temperature sensor interface CN3 is a 4PIN green terminal. The table below shows the definition of temperature sensor. The user directly inserts the supporting connection line with terminal.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | +5V_out | Sensor P interface | +5V power supply, maximum output is 500mA |
| 2 | Light | Sensor L interface | — |
| 3 | Temp | Sensor T interface | — |
| 4 | GND | Sensor G interface | — |
3.3.4 HMI Touch Screen Interface
The HMI interface is a 6PIN green terminal and power supply to and communication with HMI by the mainboard are performed via the port. The table below shows the definition of HMI interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | OVCC | +24V power output, 500mA | Panel power supply |
| 2 | TXD_HMI | Connecting to the HMI sending end | Serial port communication TXD signal |
| 3 | RXD_HMI | Connecting to the HMI receiving end | Serial port communication RXD signal |
| 4 | TXD | Reserved communication interface | RS232 reserved communication interface |
| 5 | RXD | Reserved communication interface | RS232 reserved communication interface |
| 4 | GND | Power reference ground | — |
3.3.5 CN4 Reserved Serial Port Interface
CN4 reserved serial port interface is a 5-pin green terminal without wiring. The table below shows the definition of CN4 interface.
| Pin | Signal | Definition | Description |
|---|---|---|---|
| 1 | OVCC | +24V power output, 500mA | Power supply |
| 2 | 485+ | TXD signal | Serial communication TXD signal |
| 3 | 485- | RXD signal | Serial communication RXD signal |
| 4 | GND | GND | — |
| 5 | Input0 | Reserved input interface | — |
3.3.6 CN6 External Start and Interlock Interface
The CN6 interface is a 4PIN green terminal. The table below shows the definition of CN6 interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | GND | Reference ground | Generally connecting to the start button switch on the welding head- |
| 2 | Start | External start switch input | Generally connecting to the start button switch on the welding head+ |
| 3 | Injector | Safety clamp signal input | The pin must be connected to the safety clamp and the safety clamp shall be clamped onto the metal material before welding. |
| 4 | Interlock | Safety lock signal input | The pin must be connected to the nozzle of the handheld head. The nozzle touches the metal material at the moment of welding. |
3.3.7 CN7 General Input Interface 1
The CN7 interface is a 6PIN green terminal and of NPN type. The table below shows the definition of CN7 interface.
| 引脚 | 信号 | 定义 | 说明 |
|---|---|---|---|
| 1 | GND | Reference ground | — |
| 2 | Cool | Water-cooling machine alarm input | NPN type input |
| 3 | GND | Reference ground | — |
| 4 | Input1 | Reserved | NPN type input |
| 5 | Input2 | Reserved | NPN type input |
| 6 | Input3 | Reserved | NPN type input |
3.3.8 CN8 General Output Interface
The CN8 interface is a 6-pin green terminal. By using the OC output, it can directly drive relays, with a maximum current of up to 500mA. The wiring diagram is shown below.

3.3.9 CN9 Common Input Interface 2
The CN9 interface is a 4-pin green terminal of NPN type. The table below shows the definition of the CN9 interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | GND | Reference ground | — |
| 2 | Input4 | Underpressure alarm input | — |
| 3 | Input5 | Reserved | — |
| 4 | OVCC | +24V power output | Power supply, maximum output is 500mA |
4. Operating Instructions
4.1 HMI Operating Instruction
The handheld laser welding control system operating panel (HMI) adopts a 7-inch configuration TFT touch screen with beautiful interface and convenient operation. It can set laser related parameters. On the main interface, the input and output IO status, alarm information and motion state can be displayed in real time.

HMI Functions:
- Swing off: to set galvanometer motor swing on or off.
- Safety lock: to start or close the safety lock. When the lock is started, during the welding, the laser will stop when the welding head does not touch the welding material.
- Automatic wire feeding off: to control whether to start automatic wire feeding during welding. It will start automatic wire feeding only when laser emits light.
- Emit laser: to start emitting laser or stopping emitting laser.
- Alarm status area: when alarm signal enables, protective gas low pressure, cool water flow alarm, laser alarm and temperature alarm status will be displayed in real time.
4.2 Parameter Setting
Parameter setting includes: Home page, System parameter, Wire feeding parameter and Diagnosis page.
- Home page: used to set parameters related to laser, swing and process library when welding.
- Process library: click the white box area in process library. The set process library parameter can be selected.
- Welding mode: to set welding mode, continuous and pulse modes.
- Power: to set the peak power of laser when welding.
- PWM frequency: used to set the frequency of laser PWM modulating signal.
- Duty cycle: used to set duty cycle of PWM signal with the range from 1% to 100%.
- Swing frequency: used to set motor swing frequency.
- Swing length: used to set motor swing length.
- Wire feeding parameter: used to set system parameter, including wire feeding, slow rise and fall parameters.
- Light emission time: the time that processing lasts when single point welding mode is set.

4.3 Processing Mode Switch
For welding mode switching to 110mm cleaning mode, inputting password 666666 will be reminded by clicking [Processing Type] on the panel pursuant to [System Parameter]->[Authorization]->[Processing Type]. After the password is put correctly, enter the system type selection interface.

4.4 System Switching
The system is easy to switch, the nozzle can be replaced, and the maximum cleaning width of welding seam is 1-12 mm.

4.5 APP Function
The RDWelder mobile APP supports single pendulum welding, double pendulum welding and double pendulum cleaning. After the APP is connected to the board card, it can automatically adapt to the current processing mode of the control card.
Welding mode:
- [Home Page]: Supports management of process parameters, processing status, blowing adjustment, and wire feeding control. The entry to < Technology Center > is located in the upper right corner.
- [Process]: Welding process library, where users can manage process parameters.
- [Diagnosis]: Manage the status of the equipment, support the query of alarm records, and enable central correction.
- [Settings]: Go to the parameter setting page to manage ordinary setting parameters. You can enter the authorization management. After entering the password, you can manage advanced parameters.
- [My]: Personal user page for managing personal information.
Cleaning mode:
- [Home Page]: Supports management of process parameters, processing status, and blowing adjustment. The entry to < Technology Center > is located in the upper right corner.
- [Diagnosis]: Manage the status of the equipment, support the query of alarm records, and enable central correction.
- [Settings]: Go to the parameter setting page to manage ordinary setting parameters. You can enter the authorization management. After entering the password, you can manage advanced parameters.
- [My]: Personal user page for managing personal information.

4.6 Smart Cloud Login
By visiting https://fiot.chanelink.com/, address, see page client login page. The figure below shows the user account login, new user registration, password can be recovered, and so on.

4.7 Product Function Demonstration Video
Video 1: Product function demonstration including welding, cutting, and cleaning.
5. Maintenance
5.1 Structure of Optics Lens
Replaceable components should be equipped in the dust-free plant. In principle, the modules of the optical lens can't be assembled or disassembled except the drawer of protective lens. If you have to check the collimating lens, focusing lens and galvanometer lens, please disassemble them in the clean environment.

5.2 Cleaning of Optics Lens
Tool: dust-free gloves or dust-free fingertips, dust-free cotton swab, isopropyl alcohol and canned dry pure compressed air.
Spray the isopropyl alcohol onto the dust-free cotton swab, make the lens face your eyes, gently pinch the side edge of the lens with the thumb and forefinger of your left hand, wipe the front and back of the lens in one direction from left to right or from top to bottom with dust-free cotton swab held in the right hand (remember not to wipe the lens back and forth to avoid the second contamination), and blow the surface of the lens with dry pure compressed air to ensure there is no dust on the lens.

5.3 Disassembly and Assembly of Optics Lens
Tool: 2mm inner hexagon wrench, special fixture wrench, clean cotton swab and alcohol.
The disassembly of lens should be operated with hand wearing dust-free gloves or fingertips in clean environment.


5.4 Changing Protective Glass
Steps:
- Change protective glass 01: Step 1: hold both sides of the green drawer handle module 1 in hand and pull out the protective lens horizontally. Take care of the dust, seal the port exposed on cavity with masking tape to stop the entry of dust into the cavity and replace the protective glass. Step 2: the cover is gently pressed down and rotated 90°. Loosen it when the two sides align with the two notches. Take out the cover and change the protective lens.
- Change protective glass 02: Step 1: take out the green drawer handle module 1 and pull out the protective lens horizontally. Take care of the dust, seal the port exposed on cavity with masking tape to stop the entry of dust into the cavity and replace the protective glass. Step 2: the cover is gently pressed down and rotated 90°. Loosen it when the two sides align with the two notches. Take out the cover and change the protective lens.

5.5 Module Replacement and Assembly
9.2 Module replacement
Wire feeding bracket module: loosen the 2-M3 screw and take out the module (Figure 1). Copper nozzle connecting part: loosen the 4-M2.5 screw and take out the module (Figure 2).

9.3 Assembly and Replacement
Outer case assembly: install them in order of 1, 2 and 3. Focusing drawer assembly: loosen 4-M2.5 screw and take out the focusing module directly. Pay attention that the side with a small dot in the middle is on the top when replacing and cleaning the focusing module. And the replaced welding focusing module should be protected from dust for easy replacement.

5.6 Electrical Material List
The following table lists the electrical materials included.
| S/N | Name | Illustration | Quantity | Remarks |
|---|---|---|---|---|
| 1 | Intelligent pendulum air cooled hand welding head | 1PCS | ||
| 2 | 24V power pack | ![]() | 1PCS | |
| 3 | 15V power pack | ![]() | 1PCS | |
| 4 | Ground clamp component | ![]() | 1PCS | |
| 5 | 7-inch display screen | ![]() | 1PCS | |
| 6 | Touchscreen 6-core connection cable - 1.5m - Black | ![]() | 1PCS | |
| 7 | Handheld Laser Welding System V4 | ![]() | 1PCS |
6. Troubleshooting
The system provides various alarm signals to indicate potential issues. When an alarm signal is triggered, the alarm icon is blue; when it is triggered, the alarm icon is blue and red alternately.
- Lens temperature alarm: enable lens temperature alarm. When the temperature exceeds the limited value, the alarm signal will be generated.
- Lens temperature alarm limited value: the limited value of lens temperature.
- Laser alarm enable: used to enable laser alarm. When laser generates alarm, the alarm signal will be generated.
- Laser alarm level: used to set laser alarm to trigger the level logic.
- Water-cooling machine alarm enable: used to enable water cooling machine alarm. When the water cooling machine generates alarm, the alarm signal will be generated.
- Water-cooling machine alarm level: used to set water-cooling machine alarm to trigger the level logic.
- Low pressure alarm enable: used to enable gas alarm. When gas low pressure generates alarm, the alarm signal will be generated.
- Low pressure level: used to set low pressure alarm to trigger the level logic.

7. User Tips
- For optimal welding results, ensure the material is clean and free of rust or debris before starting.
- Regularly check and clean the optics lens to maintain laser performance and prolong the lifespan of the welding head.
- When switching between welding, cutting, and cleaning modes, always verify the correct nozzle and parameters are selected on the HMI or APP.
- Utilize the mobile APP for convenient remote management and monitoring of equipment status and parameters.
8. Warranty and Support
For technical support, product information, instruction manuals, and application videos, please visit the Technology Center via the mobile APP or contact us directly.

Contact Information:
- Email: josepha@demarkchina.com
- Whatsapp: +86 18602752729
- WeChat: +86 18371977353
- Address: 2F, Building 7, Jiuyang Industrial Park, 57 Hexin West Road, Baoan District, Shenzhen, Guangdong Province