Relfar FWH20-S10C V4

Contents

Relfar FWH20-S10C V4 Single Pendulum Handheld Laser Welding Head

Welding/Cutting/Clean 4-in-1 Weld Gun

1. Product Overview

The Relfar FWH20-S10C V4 is an intelligent single pendulum handheld laser welding head designed for versatile applications including welding, cutting, and cleaning. This 4-in-1 weld gun replaces older models FWH20-S10A and FWH20-S10B, offering enhanced functionality and control.

Relfar FWH20-S10C V4 Handheld Laser Welding Head
Figure 1: Relfar FWH20-S10C V4 Handheld Laser Welding Head

1.1 Product Structure

Product Structure Diagram
Figure 2: Product Structure Diagram showing nozzle, protective lens, focus module, collimation module, QBH module, switch button, cooling water, and air port.

1.2 Cautions

To ensure personal safety, please wear special fiber laser protective glasses before operation. Keep the product clean and stop the entry into the cavity of cooling liquid, condensate water, and other objects, otherwise, the function may be impacted.

2. Specifications

The following table details the technical specifications of the FWH20-S10C V4 welding head:

Specifications Table for FWH20-S10C-V4
Figure 3: Technical Specifications
NameIntelligent single pendulum handheld welding head
ModelFWH20-S10C-V4
Fiber interfaceQBH
Wavelength range1070 ± 20nm
Rated power≤3000W
Collimating focal length50mm
Focus length150mm
Focus adjustment range-10mm ~ +10mm
Spot adjustment range0 ~ 5mm
Auxiliary gas pressure≤1Mpa
Weight0.72Kg

Additional properties:

  • High-concerned chemical: None
  • Material: Stainless steel
  • Type: Hand Tool Parts
  • Origin: Mainland China

3. Setup

3.1 Tube Connection

Cooling pipe and auxiliary gas pipe are connected as shown in the diagram. Compressed used gas: Argon, Nitrogen and compressed air. It's necessary to filter oil and water.

Tube Connection Diagram
Figure 4: Tube Connection Diagram (6mm water tube (outlet), 6mm air tube (inlet), 6mm water tube (inlet))

3.2 Fiber Input Installation

Put QBH horizontally and take out the dust seal cover. Align the red point on the optical fiber head with that in QBH, and insert the optical fiber head into QBH slowly.

Fiber Input Installation Diagram
Figure 5: Fiber Input Installation. Ensure alignment of two central red dots.

3.3 System Wiring

The following figure is a schematic diagram for wiring of the whole system. Refer to relevant chapters for detailed interface definition.

System Wiring Diagram
Figure 6: System Wiring Diagram. Note: Don't connect the reserved pin in the mainboard.

3.3.1 CN1 Wire Feeder Interface

The interface CN1 of the wire feeding machine is an 8-pin green terminal, which supports both motor wire feeding and IO wire feeding. The table below shows the definition of the wire feeding machine interface.

PinSignalDefinitionInstruction
1Pulse+Motor wire feed pulse + interfaceThe motor wire feed is used, and the driver PUL+ is connected
2Pulse-Motor wire feed pulse - interfaceMotor wire use, connected to drive PUL-
3DIR+Motor wire feed direction + interfaceMotor wire wire, connected to driver Dir +
4DIR-Motor wire feed direction - interfaceMotor wire used, connected to drive Dir-
5GNDReference ground—

3.3.2 CN2 Laser Interface

The laser interface is a 8PIN green terminal. The table below shows the definition of laser interface.

PinSignalDefinitionInstruction
1PWM+Modulated signal +Duty cycle adjustable from 1% to 99%, 24V level
2PWM-Modulated signal-Duty cycle adjustable from 1% to 99%, 24V level
3DASimulated voltage output0-10V analog voltage, used for adjusting the peak power of the laser
4GNDPower reference groundGenerally, it connects to the laser control interface DA-
5OVCC+24V power outputPower supply, capable of delivering a maximum output of 500mA
6EnableLaser enable signal24V voltage level, with high level as the valid state
7Alarm_inLaser failure alarm input—
8GATERed light indication signal24V voltage level, with low level as the active state
9GNDSignal reference ground—
10GNDSignal reference ground—

3.3.3 CN3 Temperature Sensor Interface

The temperature sensor interface CN3 is a 4PIN green terminal. The table below shows the definition of temperature sensor. The user directly inserts the supporting connection line with terminal.

PinSignalDefinitionInstruction
1+5V_outSensor P interface+5V power supply, maximum output is 500mA
2LightSensor L interface—
3TempSensor T interface—
4GNDSensor G interface—

3.3.4 HMI Touch Screen Interface

The HMI interface is a 6PIN green terminal and power supply to and communication with HMI by the mainboard are performed via the port. The table below shows the definition of HMI interface.

PinSignalDefinitionInstruction
1OVCC+24V power output, 500mAPanel power supply
2TXD_HMIConnecting to the HMI sending endSerial port communication TXD signal
3RXD_HMIConnecting to the HMI receiving endSerial port communication RXD signal
4TXDReserved communication interfaceRS232 reserved communication interface
5RXDReserved communication interfaceRS232 reserved communication interface
4GNDPower reference ground—

3.3.5 CN4 Reserved Serial Port Interface

CN4 reserved serial port interface is a 5-pin green terminal without wiring. The table below shows the definition of CN4 interface.

PinSignalDefinitionDescription
1OVCC+24V power output, 500mAPower supply
2485+TXD signalSerial communication TXD signal
3485-RXD signalSerial communication RXD signal
4GNDGND—
5Input0Reserved input interface—

3.3.6 CN6 External Start and Interlock Interface

The CN6 interface is a 4PIN green terminal. The table below shows the definition of CN6 interface.

PinSignalDefinitionInstruction
1GNDReference groundGenerally connecting to the start button switch on the welding head-
2StartExternal start switch inputGenerally connecting to the start button switch on the welding head+
3InjectorSafety clamp signal inputThe pin must be connected to the safety clamp and the safety clamp shall be clamped onto the metal material before welding.
4InterlockSafety lock signal inputThe pin must be connected to the nozzle of the handheld head. The nozzle touches the metal material at the moment of welding.

3.3.7 CN7 General Input Interface 1

The CN7 interface is a 6PIN green terminal and of NPN type. The table below shows the definition of CN7 interface.

引脚信号定义说明
1GNDReference ground—
2CoolWater-cooling machine alarm inputNPN type input
3GNDReference ground—
4Input1ReservedNPN type input
5Input2ReservedNPN type input
6Input3ReservedNPN type input

3.3.8 CN8 General Output Interface

The CN8 interface is a 6-pin green terminal. By using the OC output, it can directly drive relays, with a maximum current of up to 500mA. The wiring diagram is shown below.

Output Terminal Relay Wiring Diagram
Figure 7: Output Terminal Relay Wiring Diagram

3.3.9 CN9 Common Input Interface 2

The CN9 interface is a 4-pin green terminal of NPN type. The table below shows the definition of the CN9 interface.

PinSignalDefinitionInstruction
1GNDReference ground—
2Input4Underpressure alarm input—
3Input5Reserved—
4OVCC+24V power outputPower supply, maximum output is 500mA

4. Operating Instructions

4.1 HMI Operating Instruction

The handheld laser welding control system operating panel (HMI) adopts a 7-inch configuration TFT touch screen with beautiful interface and convenient operation. It can set laser related parameters. On the main interface, the input and output IO status, alarm information and motion state can be displayed in real time.

HMI Main Interface
Figure 8: HMI Main Interface

HMI Functions:

  • Swing off: to set galvanometer motor swing on or off.
  • Safety lock: to start or close the safety lock. When the lock is started, during the welding, the laser will stop when the welding head does not touch the welding material.
  • Automatic wire feeding off: to control whether to start automatic wire feeding during welding. It will start automatic wire feeding only when laser emits light.
  • Emit laser: to start emitting laser or stopping emitting laser.
  • Alarm status area: when alarm signal enables, protective gas low pressure, cool water flow alarm, laser alarm and temperature alarm status will be displayed in real time.

4.2 Parameter Setting

Parameter setting includes: Home page, System parameter, Wire feeding parameter and Diagnosis page.

  • Home page: used to set parameters related to laser, swing and process library when welding.
  • Process library: click the white box area in process library. The set process library parameter can be selected.
  • Welding mode: to set welding mode, continuous and pulse modes.
  • Power: to set the peak power of laser when welding.
  • PWM frequency: used to set the frequency of laser PWM modulating signal.
  • Duty cycle: used to set duty cycle of PWM signal with the range from 1% to 100%.
  • Swing frequency: used to set motor swing frequency.
  • Swing length: used to set motor swing length.
  • Wire feeding parameter: used to set system parameter, including wire feeding, slow rise and fall parameters.
  • Light emission time: the time that processing lasts when single point welding mode is set.
HMI Parameter Setting
Figure 9: HMI Parameter Setting Interface

4.3 Processing Mode Switch

For welding mode switching to 110mm cleaning mode, inputting password 666666 will be reminded by clicking [Processing Type] on the panel pursuant to [System Parameter]->[Authorization]->[Processing Type]. After the password is put correctly, enter the system type selection interface.

Processing Mode Switch
Figure 10: Processing Mode Switch Interface

4.4 System Switching

The system is easy to switch, the nozzle can be replaced, and the maximum cleaning width of welding seam is 1-12 mm.

System Switching Interface
Figure 11: System Switching Interface

4.5 APP Function

The RDWelder mobile APP supports single pendulum welding, double pendulum welding and double pendulum cleaning. After the APP is connected to the board card, it can automatically adapt to the current processing mode of the control card.

Welding mode:

  • [Home Page]: Supports management of process parameters, processing status, blowing adjustment, and wire feeding control. The entry to < Technology Center > is located in the upper right corner.
  • [Process]: Welding process library, where users can manage process parameters.
  • [Diagnosis]: Manage the status of the equipment, support the query of alarm records, and enable central correction.
  • [Settings]: Go to the parameter setting page to manage ordinary setting parameters. You can enter the authorization management. After entering the password, you can manage advanced parameters.
  • [My]: Personal user page for managing personal information.

Cleaning mode:

  • [Home Page]: Supports management of process parameters, processing status, and blowing adjustment. The entry to < Technology Center > is located in the upper right corner.
  • [Diagnosis]: Manage the status of the equipment, support the query of alarm records, and enable central correction.
  • [Settings]: Go to the parameter setting page to manage ordinary setting parameters. You can enter the authorization management. After entering the password, you can manage advanced parameters.
  • [My]: Personal user page for managing personal information.
APP Function Interface
Figure 12: RDWelder Mobile APP Function Interface

4.6 Smart Cloud Login

By visiting https://fiot.chanelink.com/, address, see page client login page. The figure below shows the user account login, new user registration, password can be recovered, and so on.

Smart Cloud Login Interface
Figure 13: Smart Cloud Login Interface

4.7 Product Function Demonstration Video

Play video
Watch video online

Video 1: Product function demonstration including welding, cutting, and cleaning.

5. Maintenance

5.1 Structure of Optics Lens

Replaceable components should be equipped in the dust-free plant. In principle, the modules of the optical lens can't be assembled or disassembled except the drawer of protective lens. If you have to check the collimating lens, focusing lens and galvanometer lens, please disassemble them in the clean environment.

Structure of Optics Lens Diagram
Figure 14: Structure of Optics Lens (D16*F50 collimation lens, 27*14*2 reflector, D20*F150 focus lens, D20*2 protective glass)

5.2 Cleaning of Optics Lens

Tool: dust-free gloves or dust-free fingertips, dust-free cotton swab, isopropyl alcohol and canned dry pure compressed air.

Spray the isopropyl alcohol onto the dust-free cotton swab, make the lens face your eyes, gently pinch the side edge of the lens with the thumb and forefinger of your left hand, wipe the front and back of the lens in one direction from left to right or from top to bottom with dust-free cotton swab held in the right hand (remember not to wipe the lens back and forth to avoid the second contamination), and blow the surface of the lens with dry pure compressed air to ensure there is no dust on the lens.

Cleaning of Optics Lens Diagram
Figure 15: Correct and Incorrect Lens Cleaning Methods

5.3 Disassembly and Assembly of Optics Lens

Tool: 2mm inner hexagon wrench, special fixture wrench, clean cotton swab and alcohol.

The disassembly of lens should be operated with hand wearing dust-free gloves or fingertips in clean environment.

Disassembly and Assembly of Optics Lens Diagram
Figure 16: Disassembly of Optics Lens (Focus lens, M2.5 internal hexagon screw, focus drawer module)
Disassembly and Assembly of Optics Lens Diagram Continued
Figure 17: Disassembly and Assembly of Optics Lens (Collimating drawer module, M2.5 internal hexagon screw, D16*F50 collimating lens)

5.4 Changing Protective Glass

Steps:

  1. Change protective glass 01: Step 1: hold both sides of the green drawer handle module 1 in hand and pull out the protective lens horizontally. Take care of the dust, seal the port exposed on cavity with masking tape to stop the entry of dust into the cavity and replace the protective glass. Step 2: the cover is gently pressed down and rotated 90°. Loosen it when the two sides align with the two notches. Take out the cover and change the protective lens.
  2. Change protective glass 02: Step 1: take out the green drawer handle module 1 and pull out the protective lens horizontally. Take care of the dust, seal the port exposed on cavity with masking tape to stop the entry of dust into the cavity and replace the protective glass. Step 2: the cover is gently pressed down and rotated 90°. Loosen it when the two sides align with the two notches. Take out the cover and change the protective lens.
Changing Protective Glass Diagram
Figure 18: Changing Protective Glass (Cap pressing, D20*2 protective glass (02), 20.5*16*2.3 elastic sealing ring, drawer handle module 2, D20*2 protective glass (01), drawer handle module 1)

5.5 Module Replacement and Assembly

9.2 Module replacement

Wire feeding bracket module: loosen the 2-M3 screw and take out the module (Figure 1). Copper nozzle connecting part: loosen the 4-M2.5 screw and take out the module (Figure 2).

Module Replacement Diagram
Figure 19: Module Replacement (Figure 1: Wire feeding bracket module, Figure 2: Copper nozzle connecting part)

9.3 Assembly and Replacement

Outer case assembly: install them in order of 1, 2 and 3. Focusing drawer assembly: loosen 4-M2.5 screw and take out the focusing module directly. Pay attention that the side with a small dot in the middle is on the top when replacing and cleaning the focusing module. And the replaced welding focusing module should be protected from dust for easy replacement.

Assembly and Replacement Diagram
Figure 20: Assembly and Replacement (Marking point for installation)

5.6 Electrical Material List

The following table lists the electrical materials included.

S/NNameIllustrationQuantityRemarks
1Intelligent pendulum air cooled hand welding headIntelligent pendulum air cooled hand welding head1PCS
224V power pack24V power pack1PCS
315V power pack15V power pack1PCS
4Ground clamp componentGround clamp component1PCS
57-inch display screen7-inch display screen1PCS
6Touchscreen 6-core connection cable - 1.5m - BlackTouchscreen 6-core connection cable1PCS
7Handheld Laser Welding System V4Handheld Laser Welding System V41PCS

6. Troubleshooting

The system provides various alarm signals to indicate potential issues. When an alarm signal is triggered, the alarm icon is blue; when it is triggered, the alarm icon is blue and red alternately.

  • Lens temperature alarm: enable lens temperature alarm. When the temperature exceeds the limited value, the alarm signal will be generated.
  • Lens temperature alarm limited value: the limited value of lens temperature.
  • Laser alarm enable: used to enable laser alarm. When laser generates alarm, the alarm signal will be generated.
  • Laser alarm level: used to set laser alarm to trigger the level logic.
  • Water-cooling machine alarm enable: used to enable water cooling machine alarm. When the water cooling machine generates alarm, the alarm signal will be generated.
  • Water-cooling machine alarm level: used to set water-cooling machine alarm to trigger the level logic.
  • Low pressure alarm enable: used to enable gas alarm. When gas low pressure generates alarm, the alarm signal will be generated.
  • Low pressure level: used to set low pressure alarm to trigger the level logic.
Temperature Parameter Setting
Figure 21: Temperature Parameter Setting Interface

7. User Tips

  • For optimal welding results, ensure the material is clean and free of rust or debris before starting.
  • Regularly check and clean the optics lens to maintain laser performance and prolong the lifespan of the welding head.
  • When switching between welding, cutting, and cleaning modes, always verify the correct nozzle and parameters are selected on the HMI or APP.
  • Utilize the mobile APP for convenient remote management and monitoring of equipment status and parameters.

8. Warranty and Support

For technical support, product information, instruction manuals, and application videos, please visit the Technology Center via the mobile APP or contact us directly.

DMK Laser Contact Information
Figure 22: Contact Information for DMK Laser

Contact Information:

  • Email: josepha@demarkchina.com
  • Whatsapp: +86 18602752729
  • WeChat: +86 18371977353
  • Address: 2F, Building 7, Jiuyang Industrial Park, 57 Hexin West Road, Baoan District, Shenzhen, Guangdong Province
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.