Relfar FWH20-DC30A-V4-T

Contents

Relfar FWH20-DC30A-V4-T Intelligent Double Pendulum Handheld Laser Cleaning Head User Manual

Model: FWH20-DC30A-V4-T

1. Product Overview

The Relfar FWH20-DC30A-V4-T is an intelligent double pendulum handheld laser cleaning head designed for efficient rust removal and surface cleaning. It features a lightweight design, high scanning speed, and a wide scanning range, making it suitable for various industrial cleaning applications.

Relfar FWH20-DC30A-V4-T Intelligent Double Pendulum Handheld Cleaning Head with key features
Figure 1: Relfar FWH20-DC30A-V4-T Handheld Laser Cleaning Head highlighting key features: Scanning range 300mm*300mm, Scanning speed 20000mm/s, and a weight of only 0.96KG.
3D CAD model of the Relfar FWH20-DC30A-V4-T cleaning head
Figure 2: 3D CAD model illustrating the design of the cleaning head.
Close-up of the Relfar FWH20-DC30A-V4-T cleaning head being held
Figure 3: Close-up view of the cleaning head, showing its ergonomic design for handheld use.

2. Safety Information

WARNING: Laser products can cause serious injury if not handled properly. Always follow safety guidelines.

  • Before operating the laser, ensure the front end flip cover plate is opened.
  • Always wear special fiber laser protective glasses during operation to protect your eyes from laser radiation.
  • Keep the product clean and prevent cooling liquid, condensate water, or any foreign matter from entering the cavity. Contamination can impact functionality and related parts.
  • Be aware of alarm messages such as safety clamp alarm, machine alarm, underpressure alarm, and lens temperature alarm, and address them promptly.

3. Specifications

The following table details the key parameters of the Relfar FWH20-DC30A-V4-T Intelligent Double Pendulum Handheld Cleaning Head:

NameParameter
ModelFWH20-DC30A-V4-T
Fiber interfaceQBH
Wavelength scope1,070±20nm
Rated power≤3000W
Collimation focal lengthF40mm
Focus focal lengthF800mm
Scanning Range300mm long *300mm wide
Scanning speed20,000mm/s
Auxiliary pressure≥0.5~0.8Mpa
Effective clear apertureφ22
Swing typeLine, Circle, Ellipse, Rectangle, Grid, etc.
Weight0.96Kg

4. Unpacking and Components

Carefully unpack the product and verify that all components are present according to the packing list below:

NumberNameArticle / SpecificationsQuantity
1Smart double swing handheld cleaning headFWH20-DC30A-V4-T1
224V switch power supplyS-60-241
3± 15V switching power supplyHF60W-D-L1
5Display card buckle/4
6Display screen7-inch screen1
7Display screen connection cable1.5m-black with 6pin male ends1
8Handheld laser welding system V4RDCleanV4-DWPro1
9Protective lensesD30*24
Packing list with images of components
Figure 4: Visual representation of the components included in the product package.

5. Installation

5.1 Pipe Connection

The system requires connections for cooling water and auxiliary protective gas.

  • Cooling Water Circuit: A 6mm air tube is connected to the cooling water inlet and outlet. The excess heat is dissipated through the internal structural member water route to ensure cleaning performance.
  • Auxiliary Protective Gas: A 6mm air tube is connected for butt welding gas protection. The recommended input pressure is 0.5-0.8MPa. Compressed air (oil-water filtration required) or argon/nitrogen can be used.
Cooling water and gas interface connection diagram
Figure 5: Diagram showing the connection points for 6mm water pipes (inlet and outlet) and gas interface.

5.2 Optical Fiber Input Installation

  1. Rotate the QBH counter-clockwise to loosen it from the limiting position. Lift up the rotating mantle and rotate it counter-clockwise until the head of the optical fiber is compressed.
  2. When the two bosses are aligned with the opening slot, rotate the gland anti-clockwise, remove them upward, and replace the lens.
  3. Align the red dot on the fiber optic head with the QBH red dot, and slowly insert the fiber optic head into the QBH.
QBH locking and loosening diagram
Figure 6: Illustration of clockwise locking and counter-clockwise loosening of the QBH.
Optical fiber input installation diagram showing red dot alignment
Figure 7: Diagram showing the alignment of two central red dots for proper fiber optic installation.

5.3 Electrical Connections

The system involves several electrical interfaces. Refer to the detailed wiring diagram and interface definitions for proper connection.

System wiring schematic diagram
Figure 8: Schematic diagram for wiring of the entire system. Note: Do not connect the reserved pin in the mainboard.

5.3.1 CN2 Laser Interface

The laser interface is an 8PIN green terminal. Table 6.5.1 shows the definition of the laser interface.

PinSignalDefinitionInstruction
1PWM+Modulated signal +Duty cycle adjustable from 1% to 99%, 24V level
2PWM-Modulated signal -Duty cycle adjustable from 1% to 99%, 24V level
3DASimulated voltage output0-10V analog voltage, used for adjusting the peak power of the laser
4GNDPower reference groundGenerally, it connects to the laser control interface DA-
5OVCC+24V power outputPower supply, capable of delivering a maximum output of 500mA
6EnableLaser enable signal24V voltage level, with high level as the valid state
7Alarm_inLaser failure alarm input—
8GATERed light indication signal24V voltage level, with low level as the active state
9GNDSignal reference ground—
10GNDSignal reference ground—

5.3.2 CN3 Temperature Sensor Interface

The temperature sensor interface CN3 is a 4PIN green terminal. Table 6.6.1 shows the definition of the temperature sensor interface.

PinSignalDefinitionInstruction
1+5V_outSensor P interface+5V power supply, maximum output is 500mA
2LightSensor L interface—
3TempSensor T interface—
4GNDSensor G interface—

5.3.3 CN4 Reserved Serial Port Interface

The CN4 reserved serial port interface is a 5-pin green terminal without wiring. Table 6.8.1 shows the definition of the CN4 interface.

PinSignalDefinitionDescription
1OVCC+24V power supply, 500mAPower supply
2485+TXD signalSerial communication TXD signal
3485-RXD signalSerial communication RXD signal
4GNDGND—
5Input0Reserved input interface—

5.3.4 CN5 Power Supply Interface

The power supply interface is a 6PIN green terminal, providing a power interface for the mainboard and galvanometer. Table 6.3.1 shows the definition of the CN5 power supply interface.

PinSignalDefinitionInstruction
124V+Power supply input+24V external power input and power supply output current: above 2A
224V-Power reference ground—
3PGNDExternal shielding groundGenerally connecting to ground or enclosure
4+15VPower supply input+15V external power input and power supply output current: above 2A
5GNDPower reference ground—
6-15VPower supply input-15V external power input and power supply output current: above 2A

5.3.5 CN6 External Start and Interlock Interface

The CN6 interface is a 4PIN green terminal. Table 6.9.1 shows the definition of the CN6 interface.

PinSignalDefinitionInstruction
1GNDReference groundGenerally connecting to the start button switch on the welding head.
2StartExternal start switch inputGenerally connecting to the start button switch on the welding head.
3InjectorSafety clamp signal inputThe pin must be connected to the safety clamp and the safety clamp shall be clamped onto the metal material before welding.
4InterlockSafety lock signal inputThe pin must be connected to the nozzle of the handheld head. The nozzle touches the metal material at the moment of welding.

5.3.6 CN7 General Input Interface 1

The CN7 interface is a 6PIN green terminal and of NPN type. Table 6.10.1 shows the definition of the CN7 interface.

PinSignalDefinitionInstruction
1GNDReference ground—
2CoolWater-cooling machine alarm inputNPN type input
3GNDReference ground—
4Input1ReservedNPN type input
5Input2ReservedNPN type input
6Input3ReservedNPN type input

5.3.7 CN8 General Output Interface

The CN8 interface is a 6-pin green terminal. By using the OC output, it can directly drive relays with a maximum current of up to 500mA. The wiring diagram is shown below.

Output terminal relay wiring diagram
Figure 9: Output terminal relay wiring diagram for CN8 interface.

5.3.8 CN9 Common Input Interface 2

The CN9 interface is a 4-pin green terminal of NPN type. Table 6.12.1 shows the definition of the CN9 interface.

PinSignalDefinitionInstruction
1GNDReference ground—
2Input4Underpressure alarm input—
3Input5Reserved—
4OVCC+24V power outputPower supply, maximum output is 500mA

5.3.9 Galvanometer Interface

The system provides two DB9 galvanometer interfaces, one DB9 male connector and one DB9 female connector.

6. Operation

6.1 HMI Operation

The handheld laser welding system operation panel (HMI) features a TFT touch screen for convenient operation. It displays real-time IO state, alarm information, and running status.

HMI main interface showing system parameters
Figure 10: HMI main interface displaying various system parameters and settings.

Key parameters and settings:

  • Scanning parameter: Used to set the parameters related to the scanning processing of the galvanometer.
  • Parameter number: Multiple groups of different cleaning parameters can be set by parameter numbers.
  • Scanning type: 9 types of scanning waveforms are available for setting dual-axis galvanometer.
  • Scanning speed: Used to set the scanning speed of the galvanometer.
  • Laser power: Used to set the percentage of the peak power of the laser.
  • Laser frequency: Used to set the PWM frequency of the laser.
  • Duty ratio: Used to set PWM signal duty ratio of continuous laser.
  • Scanning length: Used to set the length of the laser scan.
  • Double click light extraction enabling: Click the button once and the laser will come out. Double click twice to turn off.
  • Delay in enabling gas: Delay in enabling gas can be set when processing is delayed for a period of time by pressing the external start button.
  • Delay in disenabling gas: Delay in disenabling gas can be set when processing is disenabling. Stop blowing after stopping laser emission, and then delaying for a period of time when processing is stopped.
  • Scale factor: This parameter is used to set the maximum range of the galvanometer.

6.2 Processing Module Switching

To switch to 300mm cleaning mode, input password '666666' on the HMI. After confirming, the replacement of the component will be remembered.

HMI for processing module switching
Figure 11: HMI screen for selecting the type of equipment to be replaced, including welding and cleaning modes.

6.3 APP Operation (RDWelder Mobile APP)

The RDWelder mobile APP provides remote control and monitoring capabilities for the laser cleaning head. It supports various applications including single pendulum welding/cleaning and double pendulum welding/cleaning.

6.3.1 APP Download

  • Android: Scan the QR code below or visit this link.
  • Apple (iOS): Search for "RDWelder" in the App Store.
QR code for Android APP download
Figure 12: QR code for downloading the Android version of the RDWelder APP.

6.3.2 APP Connection

The handheld APP and control card support two connection modes: AP mode and STA mode.

  • AP Mode: In AP mode, the APP is directly connected to the control card. The control card emits a WiFi hotspot signal. Users can connect mobile devices to this WiFi hotspot. After connection, the board card can be controlled using the APP.
  • STA Mode: In STA mode, the APP and the control card are connected to the cloud via the Internet. After setting the control card to STA mode, it is necessary to connect to WiFi to access the network. Access the server through traffic data to obtain the device status and perform operation control.
APP connection steps in AP mode
Figure 13: Steps for connecting the APP in AP mode, showing the WiFi configuration page.
APP connection steps in STA mode
Figure 14: Steps for connecting the APP in STA mode, showing WiFi settings and device management.

6.3.3 APP Functions

The RDWelder mobile APP provides the following main functions:

  • Home Page: Supports management of process parameters, processing status, blowing adjustment, and entry to the Technology Center.
  • Process: Welding process library, where users can manage process parameters.
  • Diagnosis: Manage the status of the equipment, support the query of alarm records, and enable central correction.
  • Settings: Go to the parameter setting page to manage ordinary setting parameters. You can enter the authorization management. After entering the password, you can manage advanced parameters.
  • My: Personal user page for managing personal information.
APP interface for welding and cleaning modes
Figure 15: RDWelder APP interfaces for Welding Mode and Cleaning Mode.

6.4 Cleaning Demonstration Video

Watch this video to see the Relfar FWH20-DC30A-V4-T in action, demonstrating different scanning patterns and cleaning effectiveness on rusted surfaces.

Video 1: Demonstration of the laser cleaning head's performance with various scanning patterns and widths (200mm vs 300mm).

7. Maintenance

7.1 Structure of Optics Lens

The assembly of the optics lens is completed in a dust-free plant. Only the front-end first protective glass can be disassembled for maintenance. Other modules are not designed for user disassembly. Ensure cleaning of collimating lens, focus lens, and galvanometer lens is performed in a clean environment.

Structure of optics lens diagram
Figure 16: Diagram illustrating the structure of the optics lens, including focus lens, protective glass, and galvanometer lenses.

7.2 Cleaning of Optics Lens

When the optics lenses require cleaning, follow these steps:

  1. Gather necessary tools: 2mm inner-hexagon wrench, dust-free cotton swab, isopropyl alcohol, and canned dry and pure compressed air.
  2. Spray isopropyl alcohol onto a dust-free cotton swab.
  3. Align the lens to your eyes, gently pinch the side edge of the lens with your left thumb and index finger.
  4. Hold the dust-free cotton swab with your right hand and gently wipe the front and back of the lens in a single direction (bottom to top or left to right). Avoid wiping back and forth to prevent secondary contamination.
  5. Blow the surface of the lens with compressed air to remove any remaining particles.
  6. Confirm the lens surface is free from foreign matter after cleaning.
Cleaning of optics lens diagram
Figure 17: Visual guide for proper cleaning technique of the optics lens.

7.3 Disassembly and Assembly of Protective Glass

To change the protective lens:

  1. When the two bosses are aligned with the opening slot, rotate the gland anti-clockwise, remove them upward, and replace the lens.
  2. The drawer gap should be installed upwards.
Protective lens replacement diagram
Figure 18: Diagram showing the process of removing and replacing the protective glass.

7.4 Monitoring and Protection Device

The HMI allows for setting temperature parameters for protective glass and monitoring various alarms.

  • Lens Temperature Alarm: Set the lens temperature alarm limit value (e.g., 50 degrees). If the lens temperature exceeds this value, an alarm will be triggered.
  • Monitor other alarms such as underpressure alarm, cooling-water machine alarm, and laser alarm on the HMI.
HMI for temperature monitoring and alarm settings
Figure 19: HMI screen for monitoring lens temperature, cooling water, underpressure, and laser alarms.

8. Troubleshooting

If you encounter issues with the laser cleaning head, refer to the following common problems and solutions:

  • Alarm Messages: The HMI will display specific alarm messages (e.g., safety clamp, machine, underpressure, lens temperature). Address the cause of the alarm as indicated.
  • No Laser Emission: Check if the front end flip cover plate is open and if the safety interlocks (safety clamp, nozzle contact) are engaged. Verify laser parameters on the HMI.
  • Poor Cleaning Performance: Check the scanning speed, laser power, and scanning pattern settings. Ensure the optics lenses are clean and free from contamination.
  • Connection Issues (APP): Verify WiFi connection settings in both AP and STA modes. Ensure the device is properly registered in the APP's device list.

For complex issues not resolved by the above, please contact technical support.

9. User Tips

  • Optimize Cleaning Patterns: Experiment with the 9 available scanning waveforms (line, circle, ellipse, rectangle, grid, etc.) to find the most effective pattern for different types of rust and materials. The video demonstration shows how different patterns can achieve varying cleaning results.
  • Adjust Scanning Width: The device supports adjustable scanning widths (e.g., 200mm vs 300mm). Utilize the wider scanning range for larger surfaces to improve efficiency, and a narrower range for precision work.
  • Leverage APP Features: Use the RDWelder mobile APP for remote monitoring and management of device parameters. The Technology Center within the APP can provide additional resources and application videos.
  • Regular Maintenance: Keep the optics lenses clean as per the maintenance instructions to ensure consistent and high-quality cleaning performance. Contamination can significantly reduce efficiency.

10. Support Information

For further assistance, technical documentation, or remote support, please use the following resources:

  • Technology Center: Access the Technology Center via the RDWelder APP for product information, instruction manuals, and application videos.
  • Remote Assistance: Within the RDWelder APP, navigate to "My Applications" and select "Remote Assistance" for direct support.
  • Contact Information:
    Email: josepha@demarkchina.com
    Whatsapp: +86 18371977353
    Website: www.demarkchina.cn
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.