1. Product Overview
The Relfar FWH20-DC30A-V4-T is an intelligent double pendulum handheld laser cleaning head designed for efficient rust removal and surface cleaning. It features a lightweight design, high scanning speed, and a wide scanning range, making it suitable for various industrial cleaning applications.



2. Safety Information
WARNING: Laser products can cause serious injury if not handled properly. Always follow safety guidelines.
- Before operating the laser, ensure the front end flip cover plate is opened.
- Always wear special fiber laser protective glasses during operation to protect your eyes from laser radiation.
- Keep the product clean and prevent cooling liquid, condensate water, or any foreign matter from entering the cavity. Contamination can impact functionality and related parts.
- Be aware of alarm messages such as safety clamp alarm, machine alarm, underpressure alarm, and lens temperature alarm, and address them promptly.
3. Specifications
The following table details the key parameters of the Relfar FWH20-DC30A-V4-T Intelligent Double Pendulum Handheld Cleaning Head:
| Name | Parameter |
|---|---|
| Model | FWH20-DC30A-V4-T |
| Fiber interface | QBH |
| Wavelength scope | 1,070±20nm |
| Rated power | ≤3000W |
| Collimation focal length | F40mm |
| Focus focal length | F800mm |
| Scanning Range | 300mm long *300mm wide |
| Scanning speed | 20,000mm/s |
| Auxiliary pressure | ≥0.5~0.8Mpa |
| Effective clear aperture | φ22 |
| Swing type | Line, Circle, Ellipse, Rectangle, Grid, etc. |
| Weight | 0.96Kg |
4. Unpacking and Components
Carefully unpack the product and verify that all components are present according to the packing list below:
| Number | Name | Article / Specifications | Quantity |
|---|---|---|---|
| 1 | Smart double swing handheld cleaning head | FWH20-DC30A-V4-T | 1 |
| 2 | 24V switch power supply | S-60-24 | 1 |
| 3 | ± 15V switching power supply | HF60W-D-L | 1 |
| 5 | Display card buckle | / | 4 |
| 6 | Display screen | 7-inch screen | 1 |
| 7 | Display screen connection cable | 1.5m-black with 6pin male ends | 1 |
| 8 | Handheld laser welding system V4 | RDCleanV4-DWPro | 1 |
| 9 | Protective lenses | D30*2 | 4 |

5. Installation
5.1 Pipe Connection
The system requires connections for cooling water and auxiliary protective gas.
- Cooling Water Circuit: A 6mm air tube is connected to the cooling water inlet and outlet. The excess heat is dissipated through the internal structural member water route to ensure cleaning performance.
- Auxiliary Protective Gas: A 6mm air tube is connected for butt welding gas protection. The recommended input pressure is 0.5-0.8MPa. Compressed air (oil-water filtration required) or argon/nitrogen can be used.

5.2 Optical Fiber Input Installation
- Rotate the QBH counter-clockwise to loosen it from the limiting position. Lift up the rotating mantle and rotate it counter-clockwise until the head of the optical fiber is compressed.
- When the two bosses are aligned with the opening slot, rotate the gland anti-clockwise, remove them upward, and replace the lens.
- Align the red dot on the fiber optic head with the QBH red dot, and slowly insert the fiber optic head into the QBH.


5.3 Electrical Connections
The system involves several electrical interfaces. Refer to the detailed wiring diagram and interface definitions for proper connection.

5.3.1 CN2 Laser Interface
The laser interface is an 8PIN green terminal. Table 6.5.1 shows the definition of the laser interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | PWM+ | Modulated signal + | Duty cycle adjustable from 1% to 99%, 24V level |
| 2 | PWM- | Modulated signal - | Duty cycle adjustable from 1% to 99%, 24V level |
| 3 | DA | Simulated voltage output | 0-10V analog voltage, used for adjusting the peak power of the laser |
| 4 | GND | Power reference ground | Generally, it connects to the laser control interface DA- |
| 5 | OVCC | +24V power output | Power supply, capable of delivering a maximum output of 500mA |
| 6 | Enable | Laser enable signal | 24V voltage level, with high level as the valid state |
| 7 | Alarm_in | Laser failure alarm input | — |
| 8 | GATE | Red light indication signal | 24V voltage level, with low level as the active state |
| 9 | GND | Signal reference ground | — |
| 10 | GND | Signal reference ground | — |
5.3.2 CN3 Temperature Sensor Interface
The temperature sensor interface CN3 is a 4PIN green terminal. Table 6.6.1 shows the definition of the temperature sensor interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | +5V_out | Sensor P interface | +5V power supply, maximum output is 500mA |
| 2 | Light | Sensor L interface | — |
| 3 | Temp | Sensor T interface | — |
| 4 | GND | Sensor G interface | — |
5.3.3 CN4 Reserved Serial Port Interface
The CN4 reserved serial port interface is a 5-pin green terminal without wiring. Table 6.8.1 shows the definition of the CN4 interface.
| Pin | Signal | Definition | Description |
|---|---|---|---|
| 1 | OVCC | +24V power supply, 500mA | Power supply |
| 2 | 485+ | TXD signal | Serial communication TXD signal |
| 3 | 485- | RXD signal | Serial communication RXD signal |
| 4 | GND | GND | — |
| 5 | Input0 | Reserved input interface | — |
5.3.4 CN5 Power Supply Interface
The power supply interface is a 6PIN green terminal, providing a power interface for the mainboard and galvanometer. Table 6.3.1 shows the definition of the CN5 power supply interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | 24V+ | Power supply input | +24V external power input and power supply output current: above 2A |
| 2 | 24V- | Power reference ground | — |
| 3 | PGND | External shielding ground | Generally connecting to ground or enclosure |
| 4 | +15V | Power supply input | +15V external power input and power supply output current: above 2A |
| 5 | GND | Power reference ground | — |
| 6 | -15V | Power supply input | -15V external power input and power supply output current: above 2A |
5.3.5 CN6 External Start and Interlock Interface
The CN6 interface is a 4PIN green terminal. Table 6.9.1 shows the definition of the CN6 interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | GND | Reference ground | Generally connecting to the start button switch on the welding head. |
| 2 | Start | External start switch input | Generally connecting to the start button switch on the welding head. |
| 3 | Injector | Safety clamp signal input | The pin must be connected to the safety clamp and the safety clamp shall be clamped onto the metal material before welding. |
| 4 | Interlock | Safety lock signal input | The pin must be connected to the nozzle of the handheld head. The nozzle touches the metal material at the moment of welding. |
5.3.6 CN7 General Input Interface 1
The CN7 interface is a 6PIN green terminal and of NPN type. Table 6.10.1 shows the definition of the CN7 interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | GND | Reference ground | — |
| 2 | Cool | Water-cooling machine alarm input | NPN type input |
| 3 | GND | Reference ground | — |
| 4 | Input1 | Reserved | NPN type input |
| 5 | Input2 | Reserved | NPN type input |
| 6 | Input3 | Reserved | NPN type input |
5.3.7 CN8 General Output Interface
The CN8 interface is a 6-pin green terminal. By using the OC output, it can directly drive relays with a maximum current of up to 500mA. The wiring diagram is shown below.

5.3.8 CN9 Common Input Interface 2
The CN9 interface is a 4-pin green terminal of NPN type. Table 6.12.1 shows the definition of the CN9 interface.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | GND | Reference ground | — |
| 2 | Input4 | Underpressure alarm input | — |
| 3 | Input5 | Reserved | — |
| 4 | OVCC | +24V power output | Power supply, maximum output is 500mA |
5.3.9 Galvanometer Interface
The system provides two DB9 galvanometer interfaces, one DB9 male connector and one DB9 female connector.
6. Operation
6.1 HMI Operation
The handheld laser welding system operation panel (HMI) features a TFT touch screen for convenient operation. It displays real-time IO state, alarm information, and running status.

Key parameters and settings:
- Scanning parameter: Used to set the parameters related to the scanning processing of the galvanometer.
- Parameter number: Multiple groups of different cleaning parameters can be set by parameter numbers.
- Scanning type: 9 types of scanning waveforms are available for setting dual-axis galvanometer.
- Scanning speed: Used to set the scanning speed of the galvanometer.
- Laser power: Used to set the percentage of the peak power of the laser.
- Laser frequency: Used to set the PWM frequency of the laser.
- Duty ratio: Used to set PWM signal duty ratio of continuous laser.
- Scanning length: Used to set the length of the laser scan.
- Double click light extraction enabling: Click the button once and the laser will come out. Double click twice to turn off.
- Delay in enabling gas: Delay in enabling gas can be set when processing is delayed for a period of time by pressing the external start button.
- Delay in disenabling gas: Delay in disenabling gas can be set when processing is disenabling. Stop blowing after stopping laser emission, and then delaying for a period of time when processing is stopped.
- Scale factor: This parameter is used to set the maximum range of the galvanometer.
6.2 Processing Module Switching
To switch to 300mm cleaning mode, input password '666666' on the HMI. After confirming, the replacement of the component will be remembered.

6.3 APP Operation (RDWelder Mobile APP)
The RDWelder mobile APP provides remote control and monitoring capabilities for the laser cleaning head. It supports various applications including single pendulum welding/cleaning and double pendulum welding/cleaning.
6.3.1 APP Download
- Android: Scan the QR code below or visit this link.
- Apple (iOS): Search for "RDWelder" in the App Store.

6.3.2 APP Connection
The handheld APP and control card support two connection modes: AP mode and STA mode.
- AP Mode: In AP mode, the APP is directly connected to the control card. The control card emits a WiFi hotspot signal. Users can connect mobile devices to this WiFi hotspot. After connection, the board card can be controlled using the APP.
- STA Mode: In STA mode, the APP and the control card are connected to the cloud via the Internet. After setting the control card to STA mode, it is necessary to connect to WiFi to access the network. Access the server through traffic data to obtain the device status and perform operation control.


6.3.3 APP Functions
The RDWelder mobile APP provides the following main functions:
- Home Page: Supports management of process parameters, processing status, blowing adjustment, and entry to the Technology Center.
- Process: Welding process library, where users can manage process parameters.
- Diagnosis: Manage the status of the equipment, support the query of alarm records, and enable central correction.
- Settings: Go to the parameter setting page to manage ordinary setting parameters. You can enter the authorization management. After entering the password, you can manage advanced parameters.
- My: Personal user page for managing personal information.

6.4 Cleaning Demonstration Video
Watch this video to see the Relfar FWH20-DC30A-V4-T in action, demonstrating different scanning patterns and cleaning effectiveness on rusted surfaces.
7. Maintenance
7.1 Structure of Optics Lens
The assembly of the optics lens is completed in a dust-free plant. Only the front-end first protective glass can be disassembled for maintenance. Other modules are not designed for user disassembly. Ensure cleaning of collimating lens, focus lens, and galvanometer lens is performed in a clean environment.

7.2 Cleaning of Optics Lens
When the optics lenses require cleaning, follow these steps:
- Gather necessary tools: 2mm inner-hexagon wrench, dust-free cotton swab, isopropyl alcohol, and canned dry and pure compressed air.
- Spray isopropyl alcohol onto a dust-free cotton swab.
- Align the lens to your eyes, gently pinch the side edge of the lens with your left thumb and index finger.
- Hold the dust-free cotton swab with your right hand and gently wipe the front and back of the lens in a single direction (bottom to top or left to right). Avoid wiping back and forth to prevent secondary contamination.
- Blow the surface of the lens with compressed air to remove any remaining particles.
- Confirm the lens surface is free from foreign matter after cleaning.

7.3 Disassembly and Assembly of Protective Glass
To change the protective lens:
- When the two bosses are aligned with the opening slot, rotate the gland anti-clockwise, remove them upward, and replace the lens.
- The drawer gap should be installed upwards.

7.4 Monitoring and Protection Device
The HMI allows for setting temperature parameters for protective glass and monitoring various alarms.
- Lens Temperature Alarm: Set the lens temperature alarm limit value (e.g., 50 degrees). If the lens temperature exceeds this value, an alarm will be triggered.
- Monitor other alarms such as underpressure alarm, cooling-water machine alarm, and laser alarm on the HMI.

8. Troubleshooting
If you encounter issues with the laser cleaning head, refer to the following common problems and solutions:
- Alarm Messages: The HMI will display specific alarm messages (e.g., safety clamp, machine, underpressure, lens temperature). Address the cause of the alarm as indicated.
- No Laser Emission: Check if the front end flip cover plate is open and if the safety interlocks (safety clamp, nozzle contact) are engaged. Verify laser parameters on the HMI.
- Poor Cleaning Performance: Check the scanning speed, laser power, and scanning pattern settings. Ensure the optics lenses are clean and free from contamination.
- Connection Issues (APP): Verify WiFi connection settings in both AP and STA modes. Ensure the device is properly registered in the APP's device list.
For complex issues not resolved by the above, please contact technical support.
9. User Tips
- Optimize Cleaning Patterns: Experiment with the 9 available scanning waveforms (line, circle, ellipse, rectangle, grid, etc.) to find the most effective pattern for different types of rust and materials. The video demonstration shows how different patterns can achieve varying cleaning results.
- Adjust Scanning Width: The device supports adjustable scanning widths (e.g., 200mm vs 300mm). Utilize the wider scanning range for larger surfaces to improve efficiency, and a narrower range for precision work.
- Leverage APP Features: Use the RDWelder mobile APP for remote monitoring and management of device parameters. The Technology Center within the APP can provide additional resources and application videos.
- Regular Maintenance: Keep the optics lenses clean as per the maintenance instructions to ensure consistent and high-quality cleaning performance. Contamination can significantly reduce efficiency.
10. Support Information
For further assistance, technical documentation, or remote support, please use the following resources:
- Technology Center: Access the Technology Center via the RDWelder APP for product information, instruction manuals, and application videos.
- Remote Assistance: Within the RDWelder APP, navigate to "My Applications" and select "Remote Assistance" for direct support.
- Contact Information:
Email: josepha@demarkchina.com
Whatsapp: +86 18371977353
Website: www.demarkchina.cn