EPever Tracer-AN G3 MPPT Solar Charge Controller

Contents

EPEVER Tracer-AN G3 MPPT Solar Charge Controller User Manual

Models: Tracer1206AN G3, Tracer1210AN G3, Tracer2206AN G3, Tracer2210AN G3, Tracer3210AN G3, Tracer4210AN G3 (and BLE variants)

This manual provides essential information for the safe and efficient operation of your EPEVER MPPT Solar Charge Controller.

1. General Information

The Tracer-AN G3/Tracer-AN G3 BLE series controllers are designed with advanced MPPT (Maximum Power Point Tracking) technology to maximize solar energy harvesting. They feature a self-adaptive three-stage charging mode to prolong battery lifespan and ensure system stability. The G3 BLE series includes a built-in Bluetooth module for convenient parameter reading and writing via a phone application.

Key Features:

  • Advanced MPPT technology with ≥99.5% tracking efficiency.
  • Maximum DC/DC conversion efficiency of 98%.
  • Support for multiple battery types, including lithium batteries, with stable self-activation.
  • Comprehensive electronic protections (low voltage, over voltage, overcurrent, short circuit, etc.).
  • RS485 communication interface for remote monitoring (with optional 4G/Wi-Fi modules).
  • Multiple load work modes.
  • Constant voltage output function.
  • Low self-consumption (<10mA).
Tracer-AN G3 newest version of 2024 features
Figure 1.1: Tracer-AN G3 Newest Version Features, highlighting No-Battery Mode, Constant Voltage Output, MPPT Algorithm, Lithium Battery Compatibility, Seamless Operation, Ultra-quiet & Low power, 6 load working mode, Durability & Protection.

2. Important Safety Instructions

Please read and retain this manual for future reference. Adherence to these instructions is crucial for safe operation and to prevent damage to the controller.

  • Read all instructions and warnings carefully before installation.
  • No user-serviceable components inside; do not disassemble or attempt repairs.
  • Mount the controller indoors in a well-ventilated area, away from moisture.
  • Install appropriate external fast-acting fuses/breakers.
  • Disconnect PV array and battery fuses/breakers before installation or adjustment.
  • Ensure power connections are tight to prevent overheating.

WARNING: Do not install in humid, high salt spray, corrosive, greasy, flammable, explosive, or dusty environments.

Disclaimers:

The warranty does not cover damage resulting from:

  • Improper use or unsuitable environment.
  • Current/voltage/power exceeding controller limits.
  • Working temperature outside the rated range.
  • Failure to follow instructions or stickers (e.g., arc, fire, explosion).
  • Unauthorized dismantling or attempted repair.
  • Force majeure.
  • Damage during transportation or handling.

3. Setup (Installation)

3.1 Product Characteristics:

Familiarize yourself with the controller's components and interfaces.

Product Characteristics diagram with numbered components
Figure 3.1: Product Characteristics. 1: SELECT button, 2: RTS Interface, 3: PV Terminals, 4: Battery Terminals, 5: Load Terminals, 6: RS485 communication interface, 7: Mounting Hole Φ5mm, 8: ENTER button, 9: LCD.

Note: If the temperature sensor is not connected or damaged, the controller will charge/discharge at a default temperature of 25 °C (no temperature compensation).

3.2 Connection Diagram:

Follow the connection order carefully to ensure proper system setup.

Wiring diagram for MPPT Solar Charge Controller, PV Panel, Battery, DC Load, and optional Inverter
Figure 3.2: System Wiring Diagram. Connect in order: 1. Battery, 2. DC Load, 3. PV Panel, 4. Inverter (optional). Disconnect in reverse order: 4-3-2-1.

CAUTION: Battery must be connected first! Never connect the solar panel array to the controller without or before connecting the battery. Do not connect any inverter/wind/alternator or charger directly to the charge controller; connect them with the battery and add a fuse.

3.3 Requirements for the PV Array and Wire Size:

The PV array's output current varies. Refer to the PV module's specifications for ISC (short circuit current) to calculate minimum wire size. The total ISC of the PV array must not exceed the controller's maximum PV input current.

Table 3.1: Max. PV Input Current and Wire Size
Model Max. PV input current Max. PV wire size
Tracer1206/1210AN G3/BLE 10A 4mm²/12AWG
Tracer2206/2210AN G3/BLE 20A 6mm²/10AWG
Tracer3210AN G3/BLE 30A 10mm²/8AWG
Tracer4210AN G3/BLE 40A 16mm²/6AWG

CAUTION: The total voltage must not exceed the PV maximum open-circuit voltage. For Tracer**06AN G3/BLE, it's 46V, and for Tracer**10AN G3/BLE, it's 92V at 25°C.

3.4 Mounting:

Determine the installation location and ensure adequate heat dissipation space. The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.

Mounting diagram showing required clearance around the controller
Figure 3.3: Mounting with 150mm clearance above and below.

3.5 Grounding:

Tracer-AN G3/BLE series are common-negative controllers. Negative terminals of the PV array, battery, and load can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.

CAUTION: It is recommended to use a common-negative controller for common-negative systems (e.g., RV systems). Using a common-positive controller with a grounded positive electrode in a common-negative system may damage the controller.

3.6 Connect Accessories:

Connect the remote temperature sensor cable to the RTS interface and place the other end close to the battery. For RS485 communication, an isolator is recommended.

3.7 Power On:

Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (should be lit green). Then connect the fast-acting fuse and circuit breaker of the load and PV array. The system will then operate in preprogrammed mode.

CAUTION: If the controller is not operating properly or the battery indicator shows an abnormality, refer to the Troubleshooting section.

4. Operating Instructions

4.1 LCD Display and Buttons:

The LCD displays system status, and buttons allow for navigation and setting adjustments.

Table 4.1: Button Functions
Mode Note
Load ON/OFF Turn load On/Off via ENTER button in manual load mode.
Clear fault Press ENTER button.
Browsing mode Press SELECT button.
Setting mode Press ENTER for 5s to enter setting mode. Use SELECT to set parameters, ENTER to confirm. Exits after 10s of inactivity.
LCD display showing load control modes
Figure 4.1: Multiple Load Control Mode options (Manual, Dusk to Down with Timer, Timer, Dust to Down) with LCD display.

4.2 Battery Charging Stages:

The controller employs a three-stage charging algorithm to optimize battery health and lifespan.

  • Bulk Charging: Controller operates in constant current mode, delivering maximum current until the battery reaches the constant voltage set point.
  • Constant Charging: MPPT charging stops, and charging current gradually drops. Includes Equalize Charging (every 28th of the month for 120 minutes) and Boost Charging (default 2 hours).
  • Float Charging: Battery voltage is reduced to a float charging preset voltage. Loads can draw power from the solar panel, ensuring the battery remains fully charged.
Load Working Mode comparison between Tracer-AN and Tracer-AN G3
Figure 4.2: Load Working Mode comparison, showing 4 modes for Tracer-AN and 6 modes for Tracer-AN G3 (Manual, Light ON/OFF, Light ON/OFF+Timer 1, Light ON/OFF+Timer 2, Real-time Control, Always ON Mode).

4.3 Setting Battery Parameters:

Battery parameters can be set locally via the LCD or remotely via PC software, APP, or remote meter (MT52).

  • Local Setting (LCD): Press and hold ENTER to enter battery type interface. Use SELECT to change type, ENTER to confirm. For 'USE' battery type, specific voltage parameters can be adjusted.
  • Remote Setting (PC Software): Connect controller's RJ45 port to PC via USB to RS485 cable. Set parameters via PC software.
  • Remote Setting (APP): Connect controller to an external WiFi 2.4G adapter or Bluetooth adapter (G3 BLE series has built-in Bluetooth). Set parameters via the mobile APP.
  • Remote Setting (MT52): Connect controller to MT52 remote meter via network cable. Set parameters via MT52.

Note: The 'USE' battery type allows for custom voltage settings. If a default battery type is selected, these parameters cannot be modified. For lithium batteries, the system voltage is not automatically identified.

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your solar charge controller. Perform these inspections at least twice yearly.

  • Ensure no obstructions to airflow around the controller. Clean any dirt or fragments from the radiator.
  • Check all naked wires for damage (sun exposure, wear, insects, etc.). Repair or replace as needed.
  • Verify indicator display matches actual operation. Address any troubleshooting or error conditions.
  • Confirm terminals have no corrosion, insulation damage, or signs of overheating. Tighten terminal screws to the suggested torque.
  • Clean dirt, nesting insects, and corrosion.
  • Check the lightning arrester (if installed) and replace if necessary.

CAUTION: Risk of electric shock! Ensure the power is turned off before performing any maintenance operations.

6. Troubleshooting

This section provides guidance for common issues. For more detailed information, refer to the full user manual PDF.

Table 6.1: Common Faults and Solutions
Faults Symptoms/Indicators Troubleshooting
PV array open-circuit LCD shows no PV input despite direct sunlight. Confirm PV array connection is correct and tight.
Battery voltage is lower than 8V Controller not working. Check battery voltage (at least 8V to activate controller).
Battery over voltage Battery frame blink, fault icon blink. Check if battery voltage is higher than OVD (over voltage disconnect voltage) and disconnect PV array.
Battery over-discharged Battery frame blink. Recharge battery. Load will recover when battery voltage is restored to or above LVR (low voltage reconnect voltage).
Battery overheating Battery frame blink. Controller resumes when temperature declines below 55 °C.
Overload Load off. Reduce number of electric devices. Restart controller or press button to clear faults.
Load short-circuit Load and fault icon blink. Check load connections carefully, clear fault. Restart controller or press button to clear faults.

Note: If the load current exceeds rated value by 1.02-1.5 times, the controller will automatically turn off loads after varying delays (50s, 30s, 10s, 2s respectively).

7. Specifications

Detailed electrical and mechanical parameters for the Tracer-AN G3 series controllers.

Table of specifications for Tracer1210AN, Tracer2210AN, Tracer3210AN, Tracer4210AN models
Figure 7.1: Electrical and Mechanical Specifications for Tracer-AN G3 series (10A-40A).

Key specifications include:

  • Nominal System Voltage: 12/24VDC Auto
  • Battery Type: Lead-acid (Sealed/Gel/Flooded), Lithium (LiFePO4/Li(NiCoMn)O2), User-defined
  • Rated Charge Current: 10A, 20A, 30A, 40A (depending on model)
  • Max. PV Open Circuit Voltage: 100V (at minimum operating environment temperature)
  • MPPT Voltage Range: (Battery Voltage + 2V) ~ 72V
  • Max. Conversion Efficiency: ≤98.0%
  • Tracking Efficiency: ≥99.5%
  • Enclosure: IP30
  • Communication: RS485 (RJ45)
  • Operating Temperature: -25°C to +45°C (100% loads working)

8. User Tips

  • Verify Model: Always confirm the exact model number (e.g., Tracer-AN G3 or Tracer-AN G3 BLE) received against the product description. Differences exist, particularly regarding built-in Bluetooth and specific lithium battery settings.
  • Lithium Battery Settings: If using lithium batteries, ensure your controller model supports them and that you correctly configure the battery type and parameters. The G3 BLE models offer more advanced lithium battery compatibility and easier setup via APP.
  • Wire Sizing: For long distances between the PV array and controller, or between the controller and battery, use larger gauge wires than the minimum recommended to reduce voltage drop and improve overall system performance.
  • Fuse Protection: Always install appropriate fuses on the battery side and for any connected inverters or loads to protect the system from overcurrents.

9. Warranty and Support

For detailed warranty information, technical support, and further inquiries, please refer to the official EPEVER documentation or contact the manufacturer directly.

A comprehensive user manual in PDF format is available for download: EPEVER MPPT Solar Charge Controller User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.