EPEVER ET5420NC G3

Contents

EPEVER ET-NC ET5420NC G3 MPPT Solar Charge Controller User Manual

Model: ET5420NC G3

1. Overview

The EPEVER ET-NC G3 MPPT Charge Controller for Battery Storage is a high-efficiency solar charging solution designed for off-grid and hybrid energy systems. With 50A-100A charging capacity and 99.9% MPPT tracking efficiency, it maximizes power generation from solar panels while ensuring stable and reliable battery charging. Compatible with 12V, 24V, and 48V battery systems, it supports both lithium and lead-acid batteries, making it a versatile choice for various solar energy applications.

Equipped with RS485 communication, the ET-NC G3 allows for seamless integration with Bluetooth, WiFi, or 4G modules, enabling real-time remote monitoring and system control. Its CAN bus interface supports parallel operation of up to six controllers, making it ideal for large-scale solar energy storage solutions. Whether used in residential, commercial, or industrial setups, this controller ensures efficient energy management and system scalability.

Built for durability and long-term performance, the ET-NC G3 features a rugged metal housing and IP32/IP43 protection, providing resistance to dust, moisture, and extreme temperatures. Advanced electronic protections, including overcharge, over-discharge, short circuit, and thermal safeguards, help extend battery life and maintain system stability. With its high-efficiency MPPT tracking and smart charging capabilities, this controller is an excellent choice for anyone looking to optimize their off-grid solar battery storage system.

Front view of the EPEVER ET-NC ET5420NC G3 MPPT Solar Charge Controller
Front view of the EPEVER ET-NC ET5420NC G3 MPPT Solar Charge Controller.

2. Key Features

  • Supports 12V/24V/36V/48V systems with charging currents from 50A to 100A.
  • All-metal die-casting shell with IP43 protection (IP32 without terminal cover).
  • Supports two PV inputs (ET10420NC G3 model).
  • Maximum MPPT tracking efficiency: 99.9%; Maximum conversion efficiency: 98.5%.
  • Compatible with various battery types: AGM, Gel, Flooded, LiFePO4, and User-defined.
  • Features a 'No battery mode' for direct load supply with sufficient PV energy.
  • Communication interface with electrical isolation.
  • CAN Communication: Allows parallel operation of up to 6 devices (with or without batteries).
  • BMS Communication: Ensures reliable lithium battery charge/discharge management (requires BMS-LINK module for non-EPEVER batteries).
  • RS485 Communication: Supports optional Bluetooth, WiFi, or 4G modules for remote monitoring.
  • Real-time data recording, event logging, and power statistics function.
  • EMC compliant (CLASS B).

3. Setup and Installation

Before installation, ensure all components are present and undamaged. Mount the controller in a well-ventilated area, away from direct sunlight, high temperatures, and moisture. Maintain adequate clearance around the controller for heat dissipation.

3.1 Mounting

  • Select a vertical mounting surface.
  • Use the mounting dimensions (295 × 130 mm) and hole size (Φ7 mm) provided in the specifications.
  • Ensure proper ventilation around the heat sink.

3.2 Wiring Connections

Follow the connection order carefully to prevent damage to the controller or battery. Always connect the battery first, then the PV array.

  1. Battery Connection: Connect the battery to the 'BATT' terminals on the controller. Ensure correct polarity. The recommended cable size for the ET5420NC G3 is 6AWG/16mm².
  2. PV Array Connection: Connect the solar panel array to the 'PV' terminals on the controller. Ensure correct polarity and that the open-circuit voltage of the PV array does not exceed the controller's maximum input voltage (200V at lowest temperature; 180V at 25°C).
  3. Load Connection (Optional): If using the 'No battery mode' for direct load supply, connect your DC load to the designated load terminals (if available and supported by your specific model configuration).
  4. Communication Ports (Optional): Connect RS485, CAN, or other communication modules as needed for monitoring or parallel operation.
Perspective view of the EPEVER ET-NC ET5420NC G3 MPPT Solar Charge Controller showing terminals
Perspective view showing PV and BATT terminals.
Rear view of the EPEVER ET-NC ET5420NC G3 MPPT Solar Charge Controller showing communication ports
Rear view showing communication ports (RS485, CAN, COM).

4. Operation

Once properly installed, the controller will automatically begin charging the battery from the solar array. The integrated display provides real-time information about the system status.

4.1 Display and Buttons

The front panel features an LCD display and control buttons (Up, Down, Enter, Escape) for navigating menus and adjusting settings. The display shows parameters such as PV voltage, battery voltage, charging current, and system status.

4.2 Battery Type Selection

It is crucial to select the correct battery type in the controller settings to ensure optimal charging and prolong battery life. The controller supports AGM (Default), Gel, Flooded, LiFePO4, and User-defined battery types. Refer to the detailed manual for specific parameter adjustments for each battery type.

4.3 No Battery Mode

The controller can operate in a 'No battery mode' to directly supply power to a DC load when sufficient PV energy is available. This mode is useful for applications where a battery is not required or desired, but stable PV input is necessary.

4.4 Communication

The RS485 and CAN communication ports allow for advanced monitoring and control. Connect optional Bluetooth, WiFi, or 4G modules to the RS485 port for remote access. The CAN bus enables parallel operation of multiple controllers for increased system capacity.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your solar charge controller.

  • Cleanliness: Periodically clean the controller's exterior, especially the heat sink fins, to prevent dust buildup that can impede cooling. Use a dry cloth.
  • Connections: Annually check all wiring connections for tightness and corrosion. Loose connections can cause overheating and power loss.
  • Environment: Ensure the installation environment remains within the specified operating temperature and humidity ranges. Protect the controller from direct water exposure.
  • Firmware: Check the manufacturer's website for any available firmware updates to ensure your controller has the latest features and bug fixes.

6. Troubleshooting

This section provides general guidance for common issues. For detailed error codes and advanced troubleshooting, refer to the comprehensive product manual available from EPEVER.

ProblemPossible CauseSolution
No charging currentPV array not connected, low PV voltage, reversed polarity, or faulty PV module.Check PV connections and polarity. Verify PV voltage is above battery voltage. Inspect PV modules.
Battery not charging fullyIncorrect battery type setting, insufficient PV power, or aging battery.Verify battery type setting. Ensure PV array size is adequate. Test battery health.
Controller display offBattery not connected, battery voltage too low, or faulty battery connection.Check battery connections and polarity. Ensure battery voltage is within operating range.
OverheatingPoor ventilation, excessive ambient temperature, or overloaded system.Improve ventilation. Relocate controller if ambient temperature is too high. Reduce load or increase PV capacity.

7. Technical Specifications

The following table details the technical specifications for the EPEVER ET-NC ET5420NC G3 MPPT Solar Charge Controller.

Technical Specifications table for EPEVER ET-NC ET5420NC G3 MPPT Solar Charge Controller
Detailed Technical Specifications for ET-NC G3 Series.
Parameter CategoryParameterET5420NC G3 Value
Electrical ParametersBattery Rated Voltage12/24/48VDC or Auto
Controller Operating Voltage Range8-62V
Battery TypeAGM (Default) / Gel / Flooded / User / LiFePO4 / Li (NCM/LMO/User)
Rated Charging/Discharging Current50A
Rated Charging Power650W/12V; 1300W/24V; 2600W/48V
Maximum Charging Power650W/12V; 1300W/24V; 2600W/48V
PV Maximum Open-circuit Voltage200V (@ lowest temperature); 180V (@ 25°C)
MPPT Operating Voltage Range(Battery voltage plus 2V, and > 28V) to 144V (@ 25°C)
Tracking Efficiency> 99.5%
Maximum Conversion Efficiency98.3%
Temperature Compensation Coefficient-3mV/°C/2V (Default)
Self-consumption (Enabled Communication)98mA/12V; 60mA/24V; 46mA/48V
Self-consumption (Disabled Communication)48mA/12V; 25mA/24V; 14mA/48V
Communication & GroundingGrounding TypeCommon negative grounding
Dry Contact (Oil Generator)Rated value: 5A/30VDC; Maximum value: 0.5A/60VDC
RS485 Communication Port5VDC/200mA (RJ45)
Mechanical ParametersDimension (L×W×H) IP43 (Controller & White Terminal Cover)307 × 253 × 145 mm
Dimension (L×W×H) IP32 (Controller Only)307 × 202 × 134 mm
Mounting Dimension (L×W)295 × 130 mm
Mounting Hole SizeΦ7 mm
Wiring terminal6AWG/16mm²
Recommended Cable6AWG/16mm²
Net Weight IP32 (Controller Only)4.79 kg
Environmental ParametersOperating Temperature Range-25°C to +60°C (Derating when temperature is higher than 40°C)
LCD Temperature Range-20°C to +70°C
Storage Temperature Range-30°C to +70°C
Relative Humidity5% - 95% (N.C.)
Altitude5,000m (< 2,000m Derating)
EnclosureIP43 (Controller & White Terminal Cover); IP32 (Controller Only)
CertificationSafetyEN/IEC62100-1
EMCEN61000-6-1 / EN61000-6-3
FCC47 CFR Part 15, Subpart B
RoHSIEC62321-5-1

8. User Tips

  • Ventilation is Key: Always ensure your controller has ample airflow, especially during peak charging times or in hot climates, to prevent derating and ensure optimal performance.
  • Check Connections Regularly: Periodically inspect all wiring connections for tightness. Loose connections can lead to voltage drops, reduced efficiency, and potential safety hazards.
  • Battery Compatibility: Double-check that the selected battery type in the controller settings matches your actual battery chemistry (e.g., LiFePO4, AGM). Incorrect settings can damage your battery.
  • Monitor Performance: Utilize the communication features (RS485 with optional modules) to monitor your system's performance. This helps in identifying potential issues early and optimizing energy harvest.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or visit the official EPEVER website. Ensure you have your product model number (ET5420NC G3) and purchase details available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.