1. Introduction and Overview
The EPEVER XTRA-N G3/XTRA-N G3 BLE series controllers are advanced Maximum Power Point Tracking (MPPT) solar charge controllers designed with a new concept. The XTRA-N G3 BLE series features a built-in Bluetooth module, enabling convenient parameter reading and modification via a smartphone application.
These controllers utilize an advanced MPPT control algorithm for ultra-fast tracking speed and high efficiency (up to 99.5% tracking efficiency, 98.5% DC/DC transfer efficiency). They are capable of accurately recognizing and tracking multi-peak maximum power points to optimize PV utilization.
Key features include independent voltage regulation (allowing direct load connection without a battery), support for various battery types (including lithium batteries), stable self-activation for lithium batteries, and comprehensive electronic protections (overcharge, over-discharge, PV & battery reverse polarity). The low self-consumption design extends system standby time, and the IP33 enclosure provides dustproof and waterproof protection. These controllers are suitable for RVs, household systems, and monitoring fields.
Video: Overview of the EPEVER XTRA-N G3 BLE Series MPPT Charge Controller, highlighting its features and internal electronics.
Image: Key features of the EPEVER MPPT Solar Charge Controller, including MPPT Technology, Safety-Based Automatic Overcharge Limiting, High Protection Level IP33, Energy-Saving, Comprehensive Electronic Protection, and Temperature Compensation.
2. Important Safety Instructions
Please read and follow all instructions and warnings carefully before installation and operation to ensure safe and efficient use of your MPPT solar charge controller.
2.1. Safety Instructions for Installation
- Read all instructions and warnings in the manual.
- Do not disassemble or attempt to repair the controller; it contains no user-serviceable components.
- Mount the controller indoors, avoiding exposure to moisture.
- Install the controller in a well-ventilated area. The heat sink can become very hot during operation.
- Install appropriate external fast-acting fuses/breakers.
- Disconnect all PV array connections and fuses/breakers before any controller installation or adjustment.
- Ensure power connections are tight to prevent excessive heating.
WARNING: Do not install the controller in humid, high salt spray, corrosive, greasy, flammable, explosive, or dusty environments.
2.2. Other Safety Instructions (FCC Compliance)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
- Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment.
- This equipment has been tested and found to comply with limits for a Class B digital device.
- If interference occurs, try reorienting/relocating the receiving antenna, increasing separation between equipment and receiver, or connecting the equipment to a different circuit. Consult a technician for help.
- This equipment complies with FCC radiation exposure limits for an uncontrolled environment. Maintain a minimum distance of 20cm between the radiator and your body.
3. Installation
3.1. Attentions
- Be careful when installing batteries, especially flooded lead-acid batteries. Wear eye protection and have fresh water available.
- Keep batteries away from metal objects to prevent short circuits.
- Ensure good ventilation, as explosive battery gases may be present during charging.
- Never install the controller in a sealed enclosure with flooded batteries.
- Ensure tight power connections and use cable clamps to prevent high heat and fire hazards.
- The controller supports lead-acid and lithium batteries.
- System cables should be selected according to 5A/mm² current density or less, following NFPA 70.
- Grounding wire size should not be less than 4mm².
- Tighten wiring screws to at least 1.2N.m.
3.2. PV Array Requirements
The controller maximizes solar energy conversion. The series number of PV modules depends on the open-circuit voltage (Voc) and maximum power point voltage (VMpp) of the MPPT controller. Refer to the tables below for guidance.
CAUTION: When PV modules are connected in series, the open-circuit voltage of the PV array must not exceed 46V (for XTRA**06N G3/BLE), 92V (for XTRA**10N G3/BLE), or 138V (for XTRA**15N G3/BLE) at 25°C. Exceeding these limits may damage the controller.
3.3. Wire Size
Wiring and installation must conform to national and local electrical codes.
PV Wire Size
The minimum PV wire size can be calculated using the PV array's short circuit current (ISC). When PV modules are in series, the ISC equals a single PV module's ISC. When in parallel, the ISC equals the sum of the PV modules' ISC. The PV array's ISC must not exceed the controller's maximum PV input current.
| Model | Max. PV input current | Max. PV wire size* | Circuit breaker |
|---|---|---|---|
| XTRA1206/1210N G3/BLE | 10A | 4mm²/12AWG | 16A/125V/2P |
| XTRA2206/2210N G3/BLE | 20A | 6mm²/10AWG | 32A/125V/2P |
| XTRA3210/3215/3415N G3/BLE | 30A | 10mm²/8AWG | 40A/125V/2P |
| XTRA4210/4215/4415N G3/BLE | 40A | 16mm²/6AWG | 63A/125V/2P |
* These are the maximum wire sizes that will fit the controller terminals.
Battery and Load Wire Size
The battery and load wire size must conform to the rated current. The reference size is as below:
| Model | Rated charge current | Rated discharge current | Battery wire size | Load wire size | Circuit breaker |
|---|---|---|---|---|---|
| XTRA1206/1210N G3/BLE | 10A | 10A | 4mm²/12AWG | 4mm²/12AWG | 16A/125V/2P |
| XTRA2206/2210N G3/BLE | 20A | 20A | 6mm²/10AWG | 6mm²/10AWG | 32A/125V/2P |
| XTRA3210/3215/3415N G3/BLE | 30A | 30A | 10mm²/8AWG | 10mm²/8AWG | 40A/125V/2P |
| XTRA4210/4215/4415N G3/BLE | 40A | 40A | 16mm²/6AWG | 16mm²/6AWG | 63A/125V/2P |
3.4. Mounting
The controller should be installed in a location with sufficient airflow. Ensure a minimum clearance of 150mm from the upper and lower edges for natural thermal convection.
Image: Mounting dimensions for the EPEVER Solar Charge Controller, showing 150mm clearance on all sides for proper ventilation.
WARNING: Risk of explosion! Never install the controller in a sealed enclosure with flooded batteries. Risk of electric shock! Disconnect the breaker before wiring solar modules.
3.5. Connection Diagram
Connect the system in the order of Battery → Load → PV array. Disconnect in the reverse order.
Battery Mode
Image: Schematic wiring diagram for the controller in Battery Mode, showing connections for PV array, battery, and load with circuit breakers and fuse.
No-battery Mode
When no battery is present, the XTRA-N G3/BLE series can be directly connected to an inverter. The inverter should be connected to the battery terminals of the controller. Ensure PV input power is greater than the load output power divided by inverter conversion efficiency and controller conversion efficiency.
Image: Schematic wiring diagram for the controller in No-battery Mode, showing connections for PV array and inverter.
3.6. Grounding
XTRA-N G3/BLE series are common-negative controllers. All negative terminals can be grounded simultaneously or individually. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.
3.7. Connect Accessories
- Remote Temperature Sensor Cable: Connect the cable to the controller's interface and place the other end near the battery. If not connected, the controller defaults to 25°C without temperature compensation.
- RS485 Communication: Refer to the 'Parameters Setting' section for details on connecting accessories for RS485 communication.
3.8. Powering on the Controller
Connect the battery's fast-acting fuse to power the controller. Check the battery indicator's status (it should be green). Then connect the fast-acting fuse and circuit breaker of the load and PV array. The system will operate in preprogrammed mode.
CAUTION: If the controller is not operating properly or the battery indicator shows an abnormality, refer to the 'Troubleshooting' section.
4. Display Units
4.1. Indicator
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| PV | Green | On Solid | PV charges the battery with a low current |
| PV | Green | OFF | 1. No sunlight 2. Connection error 3. Low PV voltage |
| Battery | Green | Slowly Flashing(1Hz) | Normal charging |
| Battery | Green | Fast Flashing(4Hz) | PV Over voltage |
| Battery | Green | On Solid | Normal |
| Battery | Green | Slowly Flashing(1Hz) | Full |
| Battery | Green | Fast Flashing(4Hz) | Overvoltage |
| Battery | Orange | On Solid | Under voltage |
| Battery | Red | On Solid | Over discharged |
| Battery | Red | Slowly Flashing(1Hz) | Battery Overheating Lithium battery Low temperature |
| Load | Yellow | On Solid | Load ON |
| Load | Yellow | OFF | Load OFF |
| PV & BATT LED | fast flashing | Controller Overheating System voltage error |
Note: When a lead-acid battery is used, the controller doesn’t have low-temperature protection. When a lithium battery is used, the system voltage can’t be identified automatically.
4.2. Button Functions
| Button | Action | Function |
|---|---|---|
| PV/+ | Press | PV browsing interface |
| PV/+ | Press & hold 5s | Setting data + Setting LCD cycle time, enabling/disabling COM port |
| BATT/- | Press | BATT browsing interface |
| BATT/- | Press & hold 5s | Cursor displacement during setting Setting battery type, capacity, temperature unit |
| LOAD/- | Press | Controller load browsing interface |
| LOAD/- | Press & hold 5s | Setting data Setting load working mode |
| SET | Press | Enter into setting interface Switch setting interface to browsing interface Confirm setting parameter |
| O/ESC | Press | Exit setting interface |
4.3. Display Icons
| Icon | Information |
|---|---|
| Sun icon | Day |
| Moon icon | Night |
| Charging icon | Charging |
| Not charging icon | Not charging |
| Discharging icon | Discharging |
| Not discharging icon | Not discharging |
5. Parameters Setting
5.1. Supported Battery Types
| Type | Description |
|---|---|
| Sealed | Default lead-acid battery type |
| Gel | Gel lead-acid battery type |
| Flooded | Flooded lead-acid battery type |
| LiFePO4 | Lithium Iron Phosphate (4S/8S/15S/16S) |
| Li(NiCoMn)O2 | Lithium Nickel Manganese Cobalt Oxide (3S/6S/7S/13S/14S) |
| User | Customizable battery parameters |
Note: If the controller supports 48V system voltage, LiFePO4 F15/F16 and Li(NiCoMn)O2 N13/N14 will be displayed.
5.2. Local Setting (via LCD)
When the default battery type is selected, voltage parameters cannot be modified. To change them, select the "USE" type.
- Enter "USE" battery type: Press the BATT/- button to browse battery parameters, then press SET to enter the setting interface. Long-press BATT/- to enter the battery-type interface. Use PV/+ or LOAD/- to select "USE" and press SET to confirm.
- Set battery parameters: Under the "USE" interface, press SET to enter the "SYS" interface. Press SET again to display the current "SYS" value. Use PV/+ or LOAD/- to modify the parameter and SET to confirm. Repeat for other parameters like Boost Charging Voltage (BCV), Float Charging Voltage (FCV), Low Voltage Reconnect (LVR), and Low Voltage Disconnect (LVD).
- Temperature Units: Long-press BATT/- to enter the battery-type interface, then press SET twice to jump to the temperature unit's interface. Use PV/+ or LOAD/- to set units and SET to confirm.
- LCD Cycle Time: The default is 2s (range 0-20s). Press PV/+ to browse PV parameters, then SET to enter the setting interface. Long-press PV/+ to enter the LCD cycle time interface. Use PV/+ or LOAD/- to set the time and SET to confirm.
- Clear Accumulated Electricity: Press PV/+ to browse PV parameters, then SET to enter the setting interface. Long-press PV/+ to enter the LCD cycle time interface. Hold PV/+ and LOAD/- for 5 seconds to clear accumulated electricity.
5.3. Remote Setting
Parameters can be set remotely using various methods:
- PC Software: Connect the controller's RJ45 interface to a PC via a USB to RS485 cable. Set voltage parameters via the PC software when "USE" battery type is selected.
- APP (External WiFi Module): Connect an external WiFi module to the RS485 communication port. Use the EPEVER APP to set voltage parameters after selecting "USE" battery type.
- APP (External Bluetooth Module): Connect an external Bluetooth module to the RS485 communication port. Use the EPEVER APP to set voltage parameters after selecting "USE" battery type.
- APP (Built-in Bluetooth Module - XTRA-N G3 BLE Series only): Connect your mobile phone to the built-in Bluetooth module. Use the EPEVER APP to set voltage parameters after selecting "USE" battery type.
- MT52 Remote Meter: Connect the controller to an MT52 remote meter via a standard network cable. Set voltage parameters via the MT52 after selecting "USE" battery type.
5.4. Load Modes
The controller supports multiple load work modes:
- Manual Control (Default): Control load ON/OFF via buttons or remote commands (PC software, APP, or remote meter).
- Light ON/OFF: Load turns ON at dusk and OFF at dawn.
- Light ON + Timer: Load turns ON at dusk and stays ON for a set duration, then turns OFF.
- Time Control: Control load ON/OFF based on real-time clock settings.
CAUTION: When selecting Light ON/OFF, Test mode, and Manual mode, only Timer 1 can be set; Timer 2 is disabled.
6. Protection Features
The EPEVER MPPT Solar Charge Controller includes comprehensive electronic protections to ensure system reliability and durability.
| Protection | Instructions/Behavior |
|---|---|
| PV Over Current/Over Power | If PV array current/power exceeds rated values, the controller will charge at rated current/power. WARNING: PV open-circuit voltage must not exceed maximum PV open-circuit voltage if charging current is higher than rated. |
| PV Short Circuit | Controller will not be damaged if short-circuited when not charging. WARNING: Do not short-circuit PV array during charging. |
| PV Reverse Polarity | Controller will not be damaged and operates normally after polarity is corrected. CAUTION: Controller may be damaged if PV array is connected reversely and actual operating power exceeds 1.5 times rated charging power. |
| Night Reverse Charging | Prevents battery discharge to PV module at night. |
| Battery Reverse Polarity | Battery can be reversely connected when PV is disconnected or reversely connected. Correct wiring to resume. WARNING: Controller may be damaged if PV connection is correct and battery connection is reversed. |
| Battery Over Voltage | Controller stops charging when battery voltage exceeds Over Voltage Disconnect Voltage. |
| Battery Over-Discharge | Controller stops battery discharging when voltage is below Low Voltage Disconnect Voltage. |
| Battery Over-Heating | Controller stops working if temperature exceeds 65°C, resumes below 55°C. |
| Lithium Battery Low Temperature | Controller stops charging/discharging if temperature is below Low Temperature Protection Threshold (LTPT), resumes above LTPT. |
| Load Short Circuit | Controller automatically cuts off output if load is short-circuited (≥ 4 times rated load current). Resumes after 5 attempts, or by pressing Load button, restarting, or waiting one night-day cycle. |
| Overload | Controller automatically cuts off output if load is overloading (≥ 1.02 times rated load current). Resumes after 5 attempts, or by pressing Load button, restarting, or waiting one night-day cycle. |
| Controller Over-Heating | Controller stops working if internal temperature exceeds 85°C, resumes below 75°C. Reduced charging power mode activates at 81°C. |
| TVS High Voltage Transients | Internal circuitry protects against high-voltage surge pulses. For areas with frequent lightning, an external surge arrester is recommended. |
Image: Graph illustrating the charging power reduction mode based on internal temperature for XTRA4215N G3/BLE 24V system.
7. Troubleshooting
If you encounter any issues with your EPEVER MPPT Solar Charge Controller, refer to the table below for common problems and their solutions.
| Possible Reason | Faults | Troubleshooting |
|---|---|---|
| PV array disconnection | Charging LED indicator off during daytime with sunshine. | Confirm PV wire connections are correct and tight. |
| Battery voltage is lower than 8V | Wire connection correct, controller not working. | Check battery voltage. At least 8V needed to activate. |
| Battery over voltage | Green charging indicator fast flashes. Battery level full, frame and fault icon blink. | Check if battery voltage is higher than OVD (over voltage disconnect voltage), disconnect PV. |
| Battery over-discharged | Red charging indicator ON solid. Battery level empty, frame and fault icon blink. | When battery voltage is restored to or above LVR (low voltage reconnect voltage), load will recover. |
| Battery Overheating | Red battery indicator slow flashes. Battery frame and fault icon blink. | Controller automatically turns off. Resumes when temperature declines below 55°C. |
| System voltage error | PV and BATT indicators fast flash. | Check if battery voltage matches system voltage level. Change battery or modify system voltage level. (Can be ignored for no-battery application if voltage levels match). |
| Load Short Circuit | No load output. LCD blinks "E001." Load and fault icons blink. | Check load connection, cancel fault. Restart controller. Or wait one night-day cycle. |
| Load Overload | No load output. LCD blinks "E002." Load and fault icons blink. | Reduce electric equipment. Restart controller. Or wait one night-day cycle. |
8. Maintenance
Perform the following inspections and maintenance tasks at least twice yearly for optimal performance:
- Ensure the controller is firmly installed in a clean and dry environment.
- Ensure no obstructions to airflow around the controller. Clean any dirt or fragments from the heat sink.
- Check all exposed wires for insulation damage (sun exposure, friction, pests). Repair or replace as needed.
- Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
- Verify LED indicators match expected status. Take corrective action for any troubleshooting or error indications.
- Confirm all system components are properly grounded.
- Confirm terminals have no corrosion, insulation damage, high temperature, or discolored signs. Tighten terminal screws to the suggested torque.
- Clean dirt, nesting insects, and corrosion.
- Check the lightning arrester's condition. Replace if necessary to protect the controller and other equipment.
WARNING: Risk of electric shock! Ensure all power is turned off before performing any inspections or operations.
9. Technical Specifications
9.1. Electrical Parameters
| Item | XTRA1206N G3/BLE | XTRA2206N G3/BLE | XTRA1210N G3/BLE | XTRA2210N G3/BLE | XTRA3210N G3/BLE | XTRA4210N G3/BLE |
|---|---|---|---|---|---|---|
| Battery Rated Voltage | 12/24VDC★ Auto | |||||
| Rated Charging Current | 10A | 20A | 10A | 20A | 30A | 40A |
| Rated Discharging Current | 10A | 20A | 10A | 20A | 30A | 40A |
| Controller Work Voltage Range | 8~31V | |||||
| PV Maximum Open-circuit Voltage | 60V (at min. operating temp) 46V (at 25°C) |
100V (at min. operating temp) 92V (at 25°C) |
||||
| MPPT Voltage Range | (Battery voltage+2V)~36V | (Battery voltage+2V)~72V | ||||
| Rated Charging Power | 130W/12V 260W/24V |
260W/12V 520W/24V |
130W/12V 260W/24V |
260W/12V 520W/24V |
390W/12V 780W/24V |
520W/12V 1040W/24V |
| Maximum Conversion Efficiency | 97.9% | 98.3% | 98.2% | 98.3% | 98.6% | 98.6% |
| Maximum Load Efficiency | 97% | 96.7% | 96.2% | 96.4% | 96.6% | 96.5% |
| Discharge-circuit Voltage Drop | ≤0.23V | |||||
| Temperature Compensation | -3mV/°C/2V (Default) | |||||
| Grounding Type | Common negative | |||||
| RS485 Port | 5VDC/200mA(RJ45) | |||||
| LCD Backlight Time | Default: 60S, Range: 0~999S (0S: backlight ON all the time) | |||||
| Item | XTRA3215N G3/BLE | XTRA4215N G3/BLE | XTRA3415N G3/BLE | XTRA4415N G3/BLE |
|---|---|---|---|---|
| Battery Rated Voltage | 12/24VDC★ Auto | 12/24/36/48VDC★ Auto | ||
| Rated Charging Current | 30A | 40A | 30A | 40A |
| Rated Discharging Current | 30A | 40A | 30A | 40A |
| Controller Work Voltage Range | 8~31V | 8~31V | 8~62V | 8~62V |
| PV Maximum Open-circuit Voltage | 150V (at min. operating temp) 138V (at 25°C) |
|||
| MPPT Voltage Range | (Battery voltage+2V)~108V | |||
| Rated Charging Power | 390W/12V 780W/24V |
520W/12V 1040W/24V |
390W/12V 780W/24V 1170W/36V 1560W/48V |
520W/12V 1040W/24V 1560W/36V 2080W/48V |
| Maximum Conversion Efficiency | 97.6% | 97.9% | 98.1% | 98.5% |
| Maximum Load Efficiency | 95.1% | 95.4% | 96.9% | 97.2% |
9.2. Mechanical Parameters
| Item | XTRA1206N G3/BLE | XTRA2206N G3/BLE | XTRA1210N G3/BLE | XTRA2210N G3/BLE | XTRA3210N G3/BLE | XTRA4210N G3/BLE |
|---|---|---|---|---|---|---|
| Dimension (L x W x H) | 175×143×48mm | 217×158×56.5mm | 175×143×48mm | 217×158×56.5mm | 230×165×63mm | 255×185×67.8mm |
| Mounting Size (L x W) | 120×134mm | 160×149mm | 120×134mm | 160×149mm | 173×156mm | 200×176mm |
| Mounting Hole Size | Φ5mm | |||||
| Terminal | 12AWG(4mm²) | 6AWG(16mm²) | 12AWG(4mm²) | 6AWG(16mm²) | 6AWG(16mm²) | 6AWG(16mm²) |
| Recommended Wire Size | 12AWG(4mm²) | 10AWG(6mm²) | 12AWG(4mm²) | 10AWG(6mm²) | 8AWG(10mm²) | 6AWG(16mm²) |
| Net Weight | 0.58kg | 0.97kg | 0.59kg | 0.97kg | 1.30kg | 1.72kg |
| Item | XTRA3215N G3/BLE | XTRA4215N G3/BLE | XTRA3415N G3/BLE | XTRA4415N G3/BLE |
|---|---|---|---|---|
| Dimension (L x W x H) | 255×185×67.8mm | 255×187×75.7mm | 255×187×75.7mm | 255×189×83.2mm |
| Mounting Size (L x W) | 200×176mm | 200×178mm | 200×178mm | 200×180mm |
| Mounting Hole Size | Φ5mm | |||
| Terminal | 6AWG(16mm²) | 6AWG(16mm²) | 6AWG(16mm²) | 6AWG(16mm²) |
| Recommended Wire Size | 8AWG(10mm²) | 6AWG(16mm²) | 8AWG(10mm²) | 6AWG(16mm²) |
| Net Weight | 1.66kg | 2.08kg | 2.16kg | 2.60kg |
9.3. Environmental Parameters
| Item | XTRA1206/2206/1210/2210/3210/4210N G3/BLE | XTRA3215/4215/3415/4415N G3/BLE |
|---|---|---|
| Work Temperature Range | -25°C ~ +50°C | -25°C ~ +45°C |
| Storage Temperature Range | -20°C ~ +70°C | |
| Relative Humidity | ≤95%, N.C. | |
| Enclosure | IP33 (3-protection against solid objects: protected against solids objects over 2.5mm. 3-protected against sprays to 60° from the vertical.) | |
| Pollution Degree | PD2 | |
Note: When a lithium battery is used, the system voltage can't be identified automatically. The temperature compensation coefficient must be "0" and can't be changed. The controller can fully load working in the work temperature range. When the internal temperature reaches 81°C, the reducing charging power mode is turned on.
10. Conversion Efficiency Curves
The manual provides detailed conversion efficiency curves for various models and voltage configurations. These graphs illustrate the controller's efficiency across different rated power outputs and MPP voltages.
Image: MPPT Technology Tracking Efficiency graph, showing current (A) vs. voltage (V) and the Maximum Power Point (MPP).
For specific models and configurations, refer to the full PDF manual for detailed graphs such as:
- 13V Conversion Efficiency Curves for Solar Module MPP Voltage (17V, 34V)
- 26V Conversion Efficiency Curves for Solar Module MPP Voltage (34V, 45V, 51V, 68V, 102V)
- 39V Conversion Efficiency Curves for Solar Module MPP Voltage (65V, 102V, 115V, 119V)
- 52V Conversion Efficiency Curves for Solar Module MPP Voltage (68V, 102V, 119V)
11. User Tips
- App Control: The built-in Bluetooth and companion app (SolarGuardian) make configuration and monitoring much easier. Pairing is simple and flawless.
- Quality: Users praise the high quality and massive heating sink, indicating good thermal management.
- Packaging: Products arrive well-packaged, ensuring safe delivery.
12. Warranty and Support
For detailed warranty information, service terms, and technical support, please refer to the complete user manual PDF provided by EPEVER. The manufacturer, HUIZHOU EPEVER TECHNOLOGY CO., LTD., is responsible for product support.
Reference: For the full user manual with detailed diagrams and comprehensive instructions, please download the PDF: EPEVER MPPT Solar Charge Controller User Manual (PDF).