EPEVER TEP Series
Contents
EPEVER TEP Series MPPT Solar Charge Controller User Manual
Models: TES6415, TES8415, TES10415, TES6425, TES7425, TES8425, TES10425
1. General Information
The EPEVER TEP Series MPPT Solar Charge Controller is designed to optimize power harvesting from solar panels. It utilizes an advanced MPPT control algorithm for efficient tracking and response to maximum power points, ensuring high conversion efficiency across various sunlight conditions.
This controller supports no-battery mode operation, allowing direct connection of loads to battery terminals. It is compatible with major lithium battery types, offering comprehensive compatibility and stable load supply. The low-power design minimizes static power consumption, extending system standby time.
Key features include charging current and power limits, automatic power reduction at high temperatures for system stability, and IP32 water-proof and dust-proof protection. It incorporates short-circuit protection and an isolated RS485 communication interface for remote monitoring via optional WiFi, Bluetooth, TCP, or 4G modules. The communication port can be enabled or disabled to further reduce static power consumption.
The self-adaptive three-stage charging mode extends battery life and improves system performance. Comprehensive electronic protections (overcharge, over-discharge, PV reverse polarity) ensure safe and stable operation. It supports parallel charging for up to 6 controllers, suitable for RVs, boats, industrial monitoring, and small to medium-scale solar power systems.
Features:
- Low power consumption with static loss less than 50mA.
- No-battery mode operation.
- Advanced MPPT technology, with maximum tracking efficiency not less than 99.5%.
- Supports two PV inputs to improve PV utilization (for TES8425, TES10415, TES10425 models).
- Conversion efficiency up to 98.5%.
- Supports multiple battery types, including lithium batteries.
- Stable self-activation for lithium batteries.
- Supports local setting of main control parameters.
- RS485 communication interface for remote monitoring (optional WiFi, Bluetooth, TCP, 4G modules).
- Dual limits for rated charging power and charging current.
- Automatic power reduction when charging at high temperature.
- Comprehensive electronic protections.
- Rated IP32 protection level.
- Built-in BMS communication port.
- Built-in CAN parallel communication port.
- Real-time data logging, event logging, and energy statistics.
- Compliant with IEC62109, EMC, and other relevant standards.

2. Important Safety Instructions
Please keep this manual for future reference.
- Read all instructions and warnings carefully before installation.
- No user-serviceable components inside; do not attempt to disassemble or repair the controller.
- Install indoors to avoid component exposure and water ingress.
- Install in a well-ventilated place; heat sink temperature can be very high during operation.
- Do not install in humid, salt spray, corrosive, greasy, flammable, explosive, or dusty environments.
- Install proper fast-acting fuses/breakers externally.
- Disconnect PV array connections and battery fast-acting fuse/breakers before installation and adjustment.
- Check wiring tightness to prevent heat accumulation from loose connections.
- The entire system should be installed and operated by professional personnel.
DANGER:
Indicates a high-level hazard that, if not avoided, will result in serious injury or death.
WARNING:
Indicates a medium-level hazard that, if not avoided, could result in death or serious injury.
CAUTION:
Indicates a low-level hazard that, if not avoided, could result in minor or moderate injury.
NOTICE:
Indicates an important reminder during operation which, if ignored, may result in an equipment error alarm.
Tip:
Indicates recommendation for reference.
Read through the user manual before any operations.
3. Product Exterior and Components
The TEP Series Solar Charge Controller features a robust design with clearly labeled indicators, buttons, and an LCD display for easy monitoring and control.


3.1 Appearance and Ports
The controller's front panel includes an indicator, an LCD display, and control buttons. The bottom panel houses various connection ports.
| No. | Description |
|---|---|
| 1 | Indicator |
| 2 | LCD |
| 3 | Buttons |
| 4 | CAN/RTS/BMS COM interface (Multi-function multiplexed port) |
| 5 | COM port (RJ45, with isolation design, 5VDC/200mA) |
| 6 | Battery terminals |
| 7 | PV1 terminals |
| 8 | PV2 terminals |
| 9 | Grounding terminal |
The CAN/RTS/BMS COM interface (Port 4) is a multi-function multiplexed port. When using lithium batteries with BMS, connect the BMS-Link module and lithium batteries through this port. The BMS-Link module converts different BMS protocols to EPEVER's standard protocols for communication. For Pylon or EPEVER batteries with specific BMS protocol numbers (21, 10, 27, 34), direct connection to port 4 is possible by removing the BMS-Link module and setting the BMS protocol number accordingly. Communication cables (CC-RJ45-RJ45-PYLON-200 or CC-RJ45-RJ45-150) may be required.
If the system lacks BMS function, set "BPRO (BMS protocol number)" to 32 and connect a remote temperature sensor (RTS-D47K) to port 4 to detect battery temperature. If no remote temperature sensor is connected, the default battery charging temperature is 25°C without compensation.
The BMS interface shares port 4 with the CAN interface. Pin definitions for this port are:
| Pin | Definition | Pin | Definition |
|---|---|---|---|
| 1 | / | 5 | CAN-L |
| 2 | / | 6 | RS485-A |
| 3 | RS485-B | 7 | / |
| 4 | CAN-H | 8 | GND |
The parallel COM port pins for multiple controllers are defined as: Pin 4 (CAN-H), Pin 5 (CAN-L), Pin 8 (GND).
The RS485 communication interface (COM port) utilizes the MODBUS protocol for remote monitoring via various modules (WiFi, Bluetooth, TCP, 4G). RS485 interface (RJ45) pins are: GND, A, B, 5VDC.
3.2 Indicators, Buttons, and LCD
The LCD provides clear information when viewed within a 90° angle. The controller features an indicator light, an LCD screen, and control buttons for interaction.
Indicator (PV and BATT)
| Indicator | Color | Status | Description |
|---|---|---|---|
| PV | Green | Solid ON | PV voltage higher than turn-off voltage, but no charging. |
| Green | Solid OFF | No sunlight; Connection error; PV low voltage. | |
| Green | Slowly flashing (1Hz) | Charging normally. | |
| Green | Fast flashing (4Hz) | PV input overvoltage, PV mode error, PV input reverse connection, PV power too low. | |
| BATT | Green | Solid ON | Battery is normal. |
| Green | Slowly flashing (1Hz) | Battery fully charged, SOC low battery alarm. | |
| Green | Fast flashing (4Hz) | Battery overvoltage, cell overvoltage. | |
| Orange | Solid ON | Battery Undervoltage (including battery pack undervoltage), cell undervoltage. | |
| Red | Solid ON | Battery over discharging. | |
| BATT | Red | Slowly flashing (1Hz) | Battery over temperature, battery low temperature, cell over temperature, cell low temperature, BMS charging protection, BMS discharging protection. |
| BATT | Red | Fast flashing (4Hz) | BMS other faults, BMS sensor fault, lithium battery rated voltage identification error alarm. |
| PV (fast flashing green) & BATT (fast flashing orange) | Equipment over temperature, DSP communication failure. | ||
Buttons Operation
| Button Icon | Operation | Description |
|---|---|---|
| ↻ | Press (< 50ms) | Exit the current interface. |
| ▲▼ | Press (< 50ms) | Browse interface: Up/Down; Set browsing interface: Up/Down; Parameters setting interface: Increase or decrease parameter value as per step size. |
| Press and hold (> 2.5s) | Browse interface: invalid; Set browsing interface: invalid; Parameters setting interface: Increase or decrease parameter value quickly as per step size. | |
| ↻ | Press (< 50ms) | Confirm the setting parameters. |
| Press and hold (> 2.5s) | Switch real-time interface to setting browsing interface; Switch setting browsing interface to parameter settings interface; Confirm setting parameters. |
LCD Icons and Status
| Name | Icon | Status |
|---|---|---|
| PV array | ☀ | Day |
| ☽ | Night | |
| ☉ | Not charging | |
| ☀☉ | Charging (B, E, F refer to bulk, equalization, and float charging respectively) | |
| PV1/PV2 | PV1/PV2 | Displays input voltage, current, power, and energy for PV1 and PV2. |
| Battery | BAT | Displays battery voltage, charging current, charging/discharging power, SOC, and temperature. |
3.3 Dimensions
The physical dimensions of the controller vary slightly by model. All dimensions are in millimeters (mm).
- TES6415: 270mm (L) × 305mm (W) × 91mm (H)
- TES6425/TES8415: 270mm (L) × 305mm (W) × 105mm (H)
- TES7425: 270mm (L) × 305mm (W) × 105mm (H)
- TES8425/TES10415: 308mm (L) × 308mm (W) × 119mm (H)
- TES10425: 308mm (L) × 308mm (W) × 119mm (H)
Mounting Hole Size for all models: Φ6.5mm.
4. Installation and Connection
4.1 Precautions
- Wear protective goggles when installing flooded lead-acid batteries. Rinse with clean water if contact with battery acid occurs.
- Guard battery and PV connections against inadvertent contact. Install the controller in an enclosure.
- Keep the battery away from metal objects to prevent short circuits.
- Ensure good ventilation as acidic gases may be generated during battery charging.
- Avoid direct sunlight and rain for outdoor installations.
- Do not install in humid, salt spray, corrosive, greasy, flammable, explosive, or dusty environments.
- Ensure tight power connections and secure cables with ties to prevent swaying, which can cause high heat, melting insulation, or fire.
- Only charge lead-acid and lithium-ion batteries within the controller's control range.
- The battery terminals can connect to a single battery or a group of batteries. Instructions apply to both.
- Select system connection cables with a current density no greater than 5A/mm².
- Strip wires to an appropriate length; exposed metal should not protrude from the terminal block.
- Grounding wire cross-sectional area should be at least 4mm² (refer to IEC62109).
- Tighten wiring screws to a torque of at least 1.2 N·m.
4.2 Installation Requirements
Ensure sufficient airflow through the controller's heat sink. Leave at least 150mm of clearance above and below the controller for natural convection. If mounted in a closed cabinet, ensure heat can be dissipated.
Heat Dissipation Space: The controller requires a minimum of 150mm clearance above and below for proper heat dissipation. This ensures optimal performance and longevity.
4.3 Wire Size
Wiring and installation must comply with national and local electrical codes.
Recommended PV Array Wire Size
PV array output current varies. Minimum PV cable specifications are based on PV Isc (short circuit current). Refer to the PV module specifications sheet for Isc values. Isc remains unchanged for series connections; for parallel connections, it's the sum of parallel modules' Isc. PV array's Isc must not exceed the controller's maximum PV input current.
| Model | Maximum Input Current | Maximum Wire Size |
|---|---|---|
| TES6415, TES6425 | 60A | 16mm²/6AWG |
| TES7425 | 75A | 25mm²/4AWG |
| TES8415 | 80A | 25mm²/4AWG |
| TES8425 | 40A*2 | 16mm²/6AWG |
| TES10415, TES10425 | 50A*2 | 16mm²/6AWG |
NOTICE:
- When PV modules connect in series at the lowest temperature, total voltage must not exceed controller's maximum PV open circuit voltage 150V (for TES**15 models).
- When PV modules connect in series at 25°C, total voltage must not exceed controller's maximum PV open circuit voltage 135V (for TES**15 models).
- When PV modules connect in series at the lowest temperature, total voltage must not exceed controller's maximum PV open circuit voltage 250V (for TES**25 models).
- When PV modules connect in series at 25°C, total voltage must not exceed controller's maximum PV open circuit voltage 225V (for TES**25 models).
Recommended Battery Wire Size
Battery wire size should be selected according to the rated current. If there is a long distance between the controller and the battery, thicker cables can be used to reduce voltage drop and improve system performance.
| Model | Rated Charging Current | Maximum Wire Size |
|---|---|---|
| TES6415, TES6425 | 60A | 16mm²/6AWG |
| TES7425 | 75A | 25mm²/4AWG |
| TES8415, TES8425 | 80A | 25mm²/4AWG |
| TES10415, TES10425 | 100A | 35mm²/2AWG |
NOTICE:
The wire size is only for reference. If there is a long distance between the PV array and the controller or between the controller and the battery, thicker cables can be used to reduce voltage drop and improve system performance.
4.4 Device Connection
DANGER:
- Risk of explosion! Never install the controller in an enclosed space with flooded batteries or where battery gas can accumulate.
- Electric shock hazard! PV array can generate very high open circuit voltage. Disconnect the circuit breaker or fast-acting fuse before wiring.
- TES series controllers do not have battery reverse polarity protection. Do not reverse battery connections, as this may damage the controller.
Connect the controller in the sequence: ① Ground > ② Battery > ③ PV array > ④ Optional accessories. Disconnect in reverse order.
4.4.1 Connecting the Ground Cable (PE)
The TES series is a common negative controller. Negative terminals of the PV array and battery can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on the shell must be grounded to effectively shield external electromagnetic interference and prevent electric shock.
NOTICE:
For common-negative systems (e.g., RV systems), a common-negative controller is recommended. Using a common-positive controller with a grounded positive electrode in a common-negative system may damage the controller.
4.4.2 Connecting the Battery
NOTICE:
- Do not connect the circuit breaker or fast-acting fuse when wiring. Ensure "+" and "-" poles are connected correctly.
- A fast-acting fuse (1.25 to 2 times the controller's rated current) must be installed on the battery side, no more than 150mm from the battery.
- If connecting an inverter, connect it directly to the battery.
Wiring Diagram for Battery Connection: Connect the battery to the BATT terminals. Ensure correct polarity. An external fuse should be installed on the positive battery cable close to the battery.
4.4.3 Connecting the PV Modules
DANGER:
Electric shock hazard! The PV array can generate very high voltage. Disconnect the circuit breaker before wiring, and ensure that the leads of "+" and "-" poles are connected correctly.
PV Independent Input: This mode allows the PV array to directly power the load without a battery. Ensure the connected load's input voltage range exceeds the system's rated voltage at the BATT terminals. The wiring involves connecting PV1 and PV2 to the controller, with circuit breakers on both positive lines, and then connecting the controller's battery terminals to an inverter (DC/AC Inverter) which powers the load. A circuit breaker is also present on the inverter's AC output. Communication modules can be connected to the COM port.
PV Parallel Input: This mode is used when multiple controllers are operating in parallel. The wiring involves connecting PV arrays to each controller (PV1 and PV2), with circuit breakers. The battery terminals of each controller are connected to a common battery bank. An inverter can be connected to the battery bank to power the load. Communication modules can be connected to the COM port of each controller.
NOTICE:
- Ensure battery connection cable length is less than 3 meters.
- Ensure communication cable length is less than 3 meters.
- Recommended PV connection cable length is less than 3 meters to meet EN/IEC61000-6-4 standard. If over 3 meters, it may not meet the standard.
- If the controller is used in an area with frequent lightning strikes, an external surge arrester must be installed at the PV input and utility input terminals.
4.4.4 Connecting the Accessories
a) Connect the BMS-Link module: For lithium batteries with BMS function, connect the BMS-Link module to port 4. Set the BMS protocol number (BPRO, UBS). The BMS-Link module converts BMS protocols for communication between the controller and lithium battery BMS. The controller will connect automatically if the correct protocol number is set.
b) Connect the remote temperature sensor (model: RTS-D47K): If the battery has no BMS, attach RTS-D47K close to the battery to detect its temperature. This data is transmitted via RS485 communication to improve system safety. Set the BMS protocol number to 32 when connecting the remote temperature sensor to the BMS port. If not connected, the default battery charging/discharging temperature is 25°C without compensation.
c) Connect the communication module: Connect communication modules (WiFi, Bluetooth, TCP, or 4G) to the RS485 COM port. This allows remote monitoring and parameter modification via a mobile APP. Refer to the user manuals of the specific communication modules for setting methods (4G module needs separate power).
5. Operation
5.1 Checking Before Powering On
- Verify that the controller is installed correctly and securely.
- Confirm that all terminal wirings are connected correctly.
5.2 Operating the Device
Connect the battery's fast-acting fuse to power on the controller. Ensure the LCD displays normally and the charge control terminal is properly inserted. Then, connect the PV array's circuit breaker. The charging indicator should flash slowly during PV charging.
Tip:
If the controller does not work properly or the fault indicator shows an error after powering on, refer to the Troubleshooting section.
5.3 Parameter Setting
The controller allows viewing real-time data and adjusting various parameters via the LCD and buttons.
5.3.1 PV Real-time Data
After powering on, press the 'Enter' button (↻) on the LCD initial interface to cycle through PV real-time data. You can view PV1 input voltage, PV1 input current, PV1 input power, PV1 input energy, PV2 input voltage, PV2 input current, PV2 input power, and PV2 input energy. Models with a single PV input will only display PV1 data.
The display sequence typically shows: PV voltage, PV current, PV power, PV energy (kWh).
5.3.2 Battery Real-time Data
From the "PV2 input energy" interface, click the 'Up' or 'Down' button (▲▼) to display battery real-time data. This includes battery voltage, battery charging current, battery charging/discharging power, battery SOC, and battery temperature.
The display sequence typically shows: Battery voltage, Battery current, Battery power, Battery SOC, Battery temperature.
5.3.3 Setting Steps
- In the PV/battery real-time data browsing interface, press and hold the 'Enter' button (↻) to enter the parameter setting interface.
- Press the 'Up' or 'Down' button (▲▼) to select the parameter to be set.
- Press and hold the 'Enter' button (↻) to enter the setting interface for the selected parameter (the parameter value will blink).
- Modify the parameter value by pressing the 'Up' or 'Down' button (▲▼).
- Press the 'Enter' button (↻) to confirm the new parameter value.
- Press the 'Exit' button (↻) to exit the parameter setting interface and return to the real-time data browsing interface.
5.3.4 Parameters List
The following table outlines the default values and setting ranges for controller parameters accessible via the LCD. Some parameters are read-only; others can be modified via PC or APP.
| No. | Parameter | Default | User Define |
|---|---|---|---|
| 1 | BT (Battery Type) | AGM | 48V system: AGM, GEL, FLD, LFP15S, LFP16S, NCM13S, NCM14S, USER 24V system: AGM, GEL, FLD, LFP8S, NCM6S, NCM7S, USER 12V system: AGM, GEL, FLD, LFP4S, NCM3S, USER |
| 2 | BC (Battery Capacity) | 100Ah | 1-4,000Ah (Small step 1Ah for ≤200Ah, 10Ah for >200Ah; Large step 5Ah for ≤200Ah, 50Ah for >200Ah). Note: Set accurately for correct display. |
| 3 | RVL (Rated Voltage Level) | 0 | 0 (auto-recognition), 12V, 24V, 36V, 48V. Note: Restart controller after modification. |
| 4 | OVD (Overvoltage Disconnect Voltage) | 16.0V (12V system) | 9.0-17.0V (12V), 18.0-34.0V (24V), 36.0-68.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 5 | CVL (Charging Voltage Limit) | 15.0V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 6 | OVR (Overvoltage Recovery Voltage) | 15.0V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 7 | ECV (Equalization Charging Voltage) | 14.6V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 8 | BCV (Bulk Charging Voltage) | 14.4V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 9 | FCV (Float Charging Voltage) | 13.8V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 10 | BVR (Bulk Voltage Recovery) | 13.2V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 11 | LVR (Low Voltage Recovery Voltage) | 12.6V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 12 | UVAR (Undervoltage Alarm Recovery Voltage) | 12.2V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 13 | UVA (Undervoltage Alarm Voltage) | 12.0V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 14 | LVD (Low Voltage Disconnect Voltage) | 11.1V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 15 | DVL (Discharging Voltage Limit) | 10.6V (12V system) | 9.0-15.5V (12V), 18.0-31.0V (24V), 36.0-62.0V (48V). Step size: 0.1V (small), 1V (large). (Only visible when BT is "USER") |
| 16 | ECT (Equalize Charging Time) | 120M | 0-180 minutes. Step size: 1 minute (small), 10 minutes (large). (Only visible when BT is "USER") |
| 17 | BCT (Bulk Charging Time) | 120M | 0-180 minutes. Step size: 1 minute (small), 10 minutes (large). (Only visible when BT is "USER") |
| 18 | LBP (Lithium Battery Protection) | OFF | OFF: Disable, ON: Enable. |
| 19 | LTCL (Low Temperature Charging Limit) | -5°C | -45°C to 10°C. Step size: 1°C (small), 10°C (large). (Goes into effect when LBP is ON) |
| 20 | MCC (Battery Max Charging Current) | 60A (TES6415/TES6425) | TES6415/TES6425: 1-60A. TES7425: 1-75A. TES8415/TES8425: 1-80A. TES10415/TES10425: 1-100A. Step size: 1A (small), 10A (large). (Cannot be modified if BMS is connected) |
| 21 | BPRO (BMS Protocol) | 32 | 1-230. Step size: 1 (small), 10 (large). |
| 22 | PCM (PV Connection Mode) | INDE | INDE (Independent Input), CENt (Parallel Input). Note: For single PV input, default is INDE (parameter invalid). |
| 23 | ADDR (Address) | 1 | 1-200. Step size: 1 (small), 10 (large). |
| 24 | BAUD (Baudrate) | 1152 | 1152, 96, 24. Note: Restart controller after modification. |
| 25 | TU (Temperature Unit) | °C | °C, °F. |
| 26 | SCT (Screen Cycle Time) | 2S | 0-100S. Step size: 1S (small), 10S (large). (0S means real-time interface not automatically switched) |
| 27 | CPE (Com Port Enable) | ON | OFF, ON. (ON: communication port enabled. OFF: external communication turned off when no PV input or charging, otherwise turned on.) |
| 28 | CAE (Clear Accumulated Energy) | OFF | OFF, ON. (ON: accumulated energy cleared once.) |
| 29 | PMCC (Parallel Battery Max Charging Current) | 1,200A | 100-1,200A. Step size: 10A (small), 100A (large). (Limits total current for parallel charging. Invalid if exceeds max charging current of individual controller * quantity of parallel controllers.) |
| 30 | RFS (Restore Factory Settings) | OFF | OFF, ON. (ON: factory settings restored once.) |
| 31 | AFV (ARM Firmware Version) | -- | Read-only. |
| 32 | DFV (DSP Firmware Version) | -- | Read-only. |
5.3.5 Battery Voltage Control Parameters
The voltage control parameters vary by battery type (AGM, GEL, FLD, LFP, NCM) and system voltage (12V, 24V, 48V). When setting battery type to "USER", these parameters can be customized. The values for 24V and 48V systems are multiples of the 12V system values.
Lead-acid battery parameters (12V system example):
| Voltage Control Parameters | AGM | GEL | FLD | User Define |
|---|---|---|---|---|
| Overvoltage Disconnect Voltage | 16.0V | 16.0V | 16.0V | 9-17V |
| Charging Voltage Limit Voltage | 15.0V | 15.0V | 15.0V | 9-15.5V |
| Overvoltage Recovery Voltage | 15.0V | 15.0V | 15.0V | 9-15.5V |
| Equalization Charging Voltage | 14.6V | -- | 14.8V | 9-15.5V |
| Bulk Charging Voltage | 14.4V | 14.2V | 14.6V | 9-15.5V |
| Float Charging Voltage | 13.8V | 13.8V | 13.8V | 9-15.5V |
| Bulk Recovery Voltage | 13.2V | 13.2V | 13.2V | 9-15.5V |
| Low Voltage Recovery Voltage | 12.6V | 12.6V | 12.6V | 9-15.5V |
| Undervoltage Alarm Recovery Voltage | 12.2V | 12.2V | 12.2V | 9-15.5V |
| Undervoltage Alarm Voltage | 12.0V | 12.0V | 12.0V | 9-15.5V |
| Low Voltage Disconnect Voltage | 11.1V | 11.1V | 11.1V | 9-15.5V |
| Discharging Voltage Limit Voltage | 10.6V | 10.6V | 10.6V | 9-15.5V |
| Equalization Charging Time | 120 minutes | -- | 120 minutes | 0-180 minutes |
| Bulk Charging Time | 120 minutes | 120 minutes | 120 minutes | 10-180 minutes |
When the battery type is changed to lithium battery, lithium battery protection is automatically enabled, and default values of "ECT" and "BCT" change to 10 minutes. When changed to "AGM, GEL or FLD", lithium battery protection is disabled, and "ECT" and "BCT" change to 120 minutes. When changed to "USER", lithium battery protection, "ECT" and "BCT" remain the same as the previous battery type.
To customize parameters for "USER" battery type, follow these logic rules:
- Overvoltage Disconnect Voltage > Charging Voltage Limit Voltage ≥ Equalization Charging Voltage > Bulk Charging Voltage ≥ Float Charging Voltage > Bulk Recovery Voltage.
- Overvoltage Disconnect Voltage > Overvoltage Recovery Voltage.
- Low Voltage Recovery Voltage > Low Voltage Disconnect Voltage ≥ Discharging Voltage Limit Voltage.
- Undervoltage Alarm Recovery Voltage > Undervoltage Alarm Voltage ≥ Discharging Voltage Limit Voltage.
- Bulk Recovery Voltage > Low Voltage Recovery Voltage.
5.3.6 Control Strategy Under Lithium Battery Protocol
When BMS is connected and BPRO (BMS protocol) is set correctly, and "UBS (Use BMS Settings)" is ON, the system follows specific control strategies:
| No. | Status/Condition | Control Strategy |
|---|---|---|
| 1 | Battery forced charge request appears. | Forced charge battery with charging current value provided by BMS. |
| 2 | BMS sends an exit forced charge command. | Exit forced charge mode and resume normal operating mode. |
| 3 | Read charging voltage upper limit and discharging voltage lower limit from BMS. | Each control voltage is converted according to the "Conversion Relationship of Each Control Voltage" table. System charges according to converted voltage value, LCD displays converted voltage. Note: If BMS communication is normal but voltage limits cannot be read, system charges according to user-set values. |
| 4 | Read charging limit current from BMS. | Limit charging current as the read charging limit value. |
| 5 | Turn off charging meter and display BCF. | BMS uploads battery full charge status (Battery is fully charged). |
| 6 | BMS voltage and current limiting parameters are taking effect. | Controller limits charging according to maximum charging current uploaded by BMS, and meter displays BLC. |
For maximum charging voltage and minimum discharging voltage of lithium battery, refer to its specification sheet.
Conversion Relationship of Each Control Voltage:
| No. | LCD | Control Voltage | Converted Voltage |
|---|---|---|---|
| 1 | OVD | Overvoltage Disconnect Voltage | Charging Voltage Upper Limit + 0.3 × Level |
| 2 | CLV | Charging Limit Voltage | Charging Voltage Upper Limit (Battery Pack Overvoltage Alarm Voltage) |
| 3 | OVR | Overvoltage Recovery Voltage | Charging Voltage Upper Limit |
| 4 | ECV | Equalization Charging Voltage | Charging Voltage Upper Limit - 0.1 × Level |
| 5 | BCV | Bulk Charging Voltage | Charging limit voltage - 0.1 × Level |
| 6 | FCV | Float Charging Voltage | Charging limit voltage - 0.1 × Level |
| 7 | BVR | Bulk Recovery Voltage | Charging Voltage Upper Limit - 0.8 × Level |
| 8 | LVR | Low Voltage Recovery Voltage | Discharging Voltage Lower Limit + 0.7 × Level |
| 9 | UVR | Undervoltage Alarm Recovery Voltage | Discharging Voltage Lower Limit + 0.7 × Level |
| 10 | UVW | Undervoltage Alarm Voltage | Discharging Voltage Lower Limit + 0.4 × Level |
| 11 | LVD | Low Voltage Disconnect Voltage | Discharging limit voltage (Battery Pack Undervoltage Alarm Voltage) |
| 12 | DLV | Discharging Limit Voltage | Discharging limit voltage - 0.7 × Level |
5.3.7 Setting Parameters Remotely
a) Setting "USER" voltage parameters by PC software: Connect the controller's COM port to a PC USB port using a USB to RS485 communication cable (optional accessory). This enables setting custom battery type parameters via PC software.
b) Setting by APP (WiFi/Bluetooth module): Connect an optional WiFi or Bluetooth module to the controller's COM port. Set "USER" voltage parameters on the APP via WiFi or Bluetooth signal. Refer to the cloud APP manual for specific setting methods.
6. Maintenance
To maintain long-term working performance, it is recommended to inspect the following items twice a year:
- Ensure proper ventilation and heat dissipation around the controller; clean dirt or debris from the heat sink.
- Check insulation of exposed cables for damage (sunlight, friction, insects, rodents). Repair or replace if necessary.
- Verify indicator and display consistency with equipment operation; note and address any fault/error displays.
- Inspect terminal blocks for corrosion, insulation damage, or high-temperature burn marks; ensure terminal screws are tight.
- If the lightning arrester has failed, replace it promptly to prevent damage to the controller or other equipment.
DANGER:
Electric shock hazard! Ensure the power supply of the controller is disconnected when performing any maintenance operations!
7. Troubleshooting
This section provides common issues, their error codes, possible reasons, and troubleshooting steps.
| Status | Error Code | Possible Reasons | Troubleshooting |
|---|---|---|---|
| PV indicator is fast flashing green. | POV | PV Overvoltage | Check if connected PV open circuit voltage is higher than max PV open circuit voltage. Alarm clears when PV open circuit voltage is below max PV open circuit voltage minus 5V. |
| PME | PV Work Mode Error | Check if PV connection method is consistent with "PCM (PV Connection Mode)" settings. | |
| RPP | PV Reverse Polarity Protection | Check if PV is connected correctly. | |
| PPL | PV Power Low | Wait for sufficient sunlight for fault to clear. | |
| BATT indicator is solid orange. | BUV | Battery Undervoltage Alarm | Disconnect loads, check if battery voltage is too low. After charging and voltage restores above "UVAR", it resumes normal operation or recharge by other methods. |
| CUV | Cell Undervoltage Protection | Check BMS communication status or BMS parameters. | |
| BATT indicator is solid red. | BOD | Battery Over Discharging Protection | Disconnect loads, check if battery voltage is too low. After charging and voltage restores above "LVR", it resumes normal operation or recharge by other methods. |
| BATT indicator is slowly flashing red. | LBVE | Lithium Battery Rated Voltage Identification Error | Check if lithium battery is connected correctly or if BMS uploaded voltage is consistent with controller battery terminals voltage. |
| BOV | Battery Overvoltage Protection | Disconnect charging, measure battery voltage. Check if battery voltage matches rated voltage level or if "OVD" setting is inconsistent. Alarm clears when voltage drops below "OVR". | |
| COV | Cell Overvoltage Protection | Check BMS communication status or BMS parameters. | |
| BOT | Battery Over Temperature | Ensure battery is in cool, well-ventilated place. Check if actual charging/discharging current exceeds "Battery Max Charging Current". If BMS connected, "MCC" is read-only. Controller resumes normal charging/discharging when temperature drops below "BATT OTPR". | |
| BLT | Battery Low Temperature | Check if ambient temperature is lower than "LTCL". Controller resumes normal operation when ambient temperature is higher than "LTCL + 2°C". | |
| COT | Cell Over Temperature Protection | Check BMS communication status or BMS parameters. | |
| CLT | Cell Low Temperature | Check BMS communication status or BMS parameters. | |
| BATT indicator is slowly flashing green. | BCP | Charging Protection (BMS) | Charge the battery to LBAR (Low Battery Alarm Recovery SOC). |
| BDP | Discharging Protection (BMS) | Charge the battery to LBAR (Low Battery Alarm Recovery SOC). | |
| SLBP | Low Battery Protection (SOC) | Charge the battery to LBAR (Low Battery Alarm Recovery SOC). | |
| - | BOCD | Over Current Discharging Alarm (BMS) | Check BMS communication status or BMS parameters. |
| BOCC | Over Current Charging Alarm (BMS) | Check BMS communication status or BMS parameters. | |
| - | BLC | Battery Limit Charging | BMS is normal, no troubleshooting needed. |
| - | PIDR | Parallel ID Repetition | Check if IDs of parallel equipment are repeated. |
| PV indicator is fast flashing green. | DOT | Device Over Temperature | Ensure controller is in cool, well-ventilated place. Controller resumes normal charging when temperature drops below "DOT". |
| BATT indicator is fast flashing orange. | DCF | DSP Communication Fault | Turn off controller, wait 5 minutes, then turn on. If error persists, contact technical support. |
8. Technical Specifications
The following tables detail the technical specifications for the EPEVER TEP Series Solar Charge Controllers.
8.1 PV Input (DC) Specifications
| Parameter | TES6415 / TES8415 / TES10415 | TES6425 / TES7425 / TES8425 / TES10425 |
|---|---|---|
| Maximum Open-circuit Voltage | 150V (@lowest temperature); 135V (@25°C) | 250V (@lowest temperature); 225V (@25°C) |
| MPPT Voltage Range | (Battery voltage plus 2V, and > 20V) to 108V (@25°C) for 150V models; (Battery voltage plus 2V, and > 20V) to 180V (@25°C) for 250V models | |
| Number of MPPTs | 1 | 2 |
8.2 Battery Specifications
| Parameter | Value |
|---|---|
| Battery Type | AGM (Default)/GEL/FLD/User |
| Lithium Battery Type | LFP/NCM/User |
| Rated Voltage | 12/24/48VDC or Auto |
| Rated Charging Current | 60A (TES6415/TES6425), 75A (TES7425), 80A (TES8415/TES8425), 100A (TES10415/TES10425) |
| Rated Charging Power | TES6415/TES6425: 780W/1560W/3120W TES7425: 975W/1950W/3900W TES8415/TES8425: 1040W/2080W/4160W TES10415/TES10425: 1300W/2600W/5200W |
| Temperature Compensation Coefficient | -3mV/°C/2V (Default) |
8.3 Controller Specifications
| Parameter | Value |
|---|---|
| Output Voltage Range | 8-62V |
| Static Loss (Enabled Communication) | 98mA/12V; 60mA/24V; 46mA/48V |
| Static Loss (Disabled Communication) | 48mA/12V; 25mA/24V; 14mA/48V |
| Grounding Type | Common negative grounding |
| Communication Method | 5VDC/200mA (RJ45) |
8.4 Efficiency
| Parameter | Value |
|---|---|
| Tracking Efficiency | ≥ 99.5% |
| Maximum Conversion Efficiency | 98.3% (TES6415/TES8415/TES10415); 98.5% (TES6425/TES7425/TES8425/TES10425) |
8.5 Environmental Parameters
| Parameter | Value |
|---|---|
| Operating Temperature | -25°C to +60°C (> 40°C derating) |
| LCD Operating Temperature | -20°C to +70°C |
| Storage Temperature | -30°C to +70°C |
| Relative Humidity | 5%-95% (N.C.) |
| Altitude | < 5,000m (> 2,000m derating) |
| Ingress Protection | IP32 |
| Pollution Degree | II |
8.6 Mechanical Parameters
| Parameter | TES6415 | TES8415 | TES10415 | TES6425 | TES7425 | TES8425 | TES10425 | |
|---|---|---|---|---|---|---|---|---|
| Dimensions (L × W × H) | 270×305×91mm | 270×305×105mm | 308×308×119mm | 270×305×105mm | 270×305×122mm | 308×308×119mm | 308×308×119mm | |
| Mounting Hole Size | Φ6.5mm | |||||||
| Weight | 3.85kg | 4.9kg | 6.55kg | 4.85kg | 5.5kg | 6.50kg | 6.6kg | |
| Recommended Cable Size | 6AWG/16mm² | 2AWG/35mm² | ||||||
8.7 Certifications
EN/IEC61000-6-2; EN/IEC61000-6-4; EN/IEC62109-1; IEC62321
9. Warranty and Technical Support
9.1 Disclaimers and Warranty Conditions
Before using the product, read this manual carefully to understand and use it correctly. Improper use may cause serious injury, product damage, or property loss. By using this product, you acknowledge and accept all terms and contents in this manual. BEIJING EPSOLAR TECHNOLOGY CO., LTD. is not liable for losses caused by failure to use the product in accordance with this manual.
The warranty does not apply to the following conditions:
- Damage caused by improper use or inappropriate environments (humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other harsh environments).
- Actual current/voltage/power exceeding the controller's limit value.
- Damage caused by operating temperature exceeding the rated temperature range.
- Electric arc, fire, explosion, and other accidents caused by failure to follow controller labels or manual instructions.
- Unauthorized disassembly and maintenance of the controller.
- Damage caused by force majeure (lightning strikes, rainstorms, mountain torrents, utility failures).
- Damage occurred during transportation or loading/unloading the controller.
For the latest product information and manual updates, please visit the official EPEVER website: www.epever.com.
A PDF version of the user manual is available for download: EPEVER TEP Series User Manual (PDF).
9.2 Technical Support
For technical inquiries regarding EPEVER products, please contact them through the following channels:
- Service Hotline: 010-82894896 / 82894112, 0752-3889706, 0755-89236770
- Email: sales@epever.com
- Website: www.epever.com
Any changes to the product or manual are subject to change without prior notice. Version number: V1.0.