1. Introduction
This manual provides essential information for the safe and effective use of the Relfar Plug-in Type Galvanometer Motor, designed for integration into compatible laser welding and cleaning heads. This motor is a critical component responsible for precise beam steering, enabling high-speed and accurate laser processing. Please read this manual thoroughly before installation and operation to ensure optimal performance and longevity of the product.
2. Product Overview
The Relfar Galvanometer Motor is a high-quality, plug-in type component engineered for demanding laser applications. It features a robust stainless steel construction and is available in various models to suit different laser head configurations (X-axis or Y-axis movement). Each motor is equipped with a precision mirror for directing the laser beam.





3. Specifications
The Relfar Galvanometer Motors are manufactured from stainless steel and are designed as plug-in components. They are produced in Mainland China and comply with various quality certifications including ROHS, CE, 3C, and FC.

General Properties:
- Material: Stainless steel
- Type: Galvanometer Motor (X-axis or Y-axis)
- High-concerned chemical: None
- Origin: Mainland China
Available Models:
| Model | Axis | Specification (e.g., Size/Variant) |
|---|---|---|
| FWH20-C11A | X / Y | 32mm |
| FWH20-C20A | X / Y | 36mm |
| FWH20-DC30A | X / Y | 22mm |
| FWH20-S10A | X / Y | 23mm |
| FWH20-S20A | X / Y | 24mm |
| FWH20-S10C | X / Y | 21mm |
| FWH20-S20C | X / Y | 27mm |
| FWH20-ES10A | Y | 10mm |
| FWH30-D10A | X / Y | 34mm |
| FWH30-D20A | X / Y | 25mm |
| FWH30-D10C | X / Y | 30mm |
| FWH30-D20C | X / Y | 6mm |
| FWH30-DS10E | X / Y | 8mm |
| FWH30-DS20E | X / Y | 9mm |
4. Setup and Installation
The Relfar Galvanometer Motor is designed as a plug-in component for specific Relfar laser welding and cleaning heads. Proper installation is crucial for performance and safety.
Safety Precautions:
- Always ensure the laser system is powered off and disconnected from the power source before attempting any installation or maintenance.
- Wear appropriate personal protective equipment (PPE), including laser safety glasses, when working with laser components.
- Handle the galvanometer motor and its mirror with extreme care to avoid damage to the optical surface. Avoid touching the mirror directly.
Installation Steps:
- Prepare the Laser Head: Refer to the specific manual for your Relfar laser welding/cleaning head for instructions on how to access the galvanometer motor slot. This may involve removing covers or other components.
- Identify Motor Axis: Ensure you are installing the correct motor (X-axis or Y-axis) into its designated slot within the laser head.
- Insert the Motor: Carefully align the galvanometer motor with the slot in the laser head. Gently push the motor into place, ensuring the electrical connector mates correctly. Do not force the motor.
- Secure the Motor: Once seated, secure the motor using any retaining screws or clamps provided by the laser head manufacturer.
- Inspect Connections: Double-check all electrical connections to ensure they are firm and correctly oriented.
- Reassemble Laser Head: Reattach any covers or components that were removed during the installation process.
- Initial Power-Up: After installation, power on the laser system according to its manual and perform initial calibration or diagnostic checks to confirm proper motor function.
5. Operating Instructions
The Relfar Galvanometer Motor functions as a precision beam steering component within a larger laser system. Its operation is controlled by the laser system's software and hardware. This section provides general guidelines; always refer to the operating manual of your specific Relfar laser welding or cleaning head for detailed instructions.
General Operation:
- System Integration: The galvanometer motor receives control signals from the laser system's controller to precisely position its mirror.
- Software Control: Laser patterns, scanning speeds, and other parameters are typically set via the laser system's control software.
- Beam Path: Ensure the laser beam path is clear and properly aligned before operation.
- Environmental Conditions: Operate the laser system, including the galvanometer motor, within the recommended environmental conditions (temperature, humidity) specified by the laser head manufacturer.
Important Considerations:
- Avoid sudden impacts or vibrations to the laser head during operation, as this can affect motor performance and mirror alignment.
- Monitor the laser system for any unusual noises or movements from the galvanometer motors, which could indicate a problem.
6. Maintenance
Regular maintenance of the galvanometer motor, particularly its optical mirror, is essential to maintain optimal laser performance and extend the lifespan of the component.
Cleaning the Mirror:
- Frequency: The cleaning frequency depends on the operating environment and usage. Inspect the mirror regularly for dust, debris, or smudges.
- Procedure:
- Power off and disconnect the laser system.
- Carefully access the galvanometer motor within the laser head.
- Use a clean, dry, oil-free compressed air source to gently blow off any loose dust particles from the mirror surface. Hold the can upright to prevent propellant discharge.
- If smudges or stubborn particles remain, use a lint-free optical wipe moistened with optical-grade isopropyl alcohol or a specialized lens cleaning solution. Wipe gently in one direction across the mirror surface. Do not rub.
- Allow the mirror to dry completely before reassembling the laser head.
- Caution: Never use abrasive materials or harsh chemicals on the mirror. Avoid touching the mirror surface with bare hands.
General Inspection:
- Periodically check the motor's mounting for any looseness.
- Inspect electrical connections for signs of wear or corrosion.
- Ensure the area around the galvanometer motor is free from excessive dust or contaminants.
7. Troubleshooting
This section outlines common issues and potential solutions for the Relfar Galvanometer Motor. For complex problems, always contact technical support.
Common Issues:
- Motor Not Responding:
- Check electrical connections to the motor and the laser system controller.
- Verify power supply to the laser head and motor.
- Consult the laser system's manual for diagnostic procedures related to galvanometer errors.
- Inaccurate Laser Patterns / Poor Quality:
- Inspect the galvanometer mirror for dirt, smudges, or damage (refer to Maintenance section).
- Check for any physical obstructions preventing free movement of the motor.
- Perform a calibration routine as per your laser system's instructions.
- Ensure the motor is securely mounted and not loose.
- Unusual Noise from Motor:
- This could indicate mechanical wear or an obstruction. Power off the system immediately.
- Inspect for any foreign objects near the motor.
- If the noise persists, contact technical support.
General Advice:
- Always ensure the laser system's software and firmware are up to date.
- Keep a log of any issues encountered, including error codes and troubleshooting steps taken, to assist technical support.
8. User Tips
No specific user tips are available at this time. Please refer to the general operating and maintenance guidelines provided in this manual.
9. Warranty & Support
Relfar products, including these galvanometer motors, are manufactured by Demark (Wuhan) Science&Technology Co., Ltd., a company with 25 years of experience in laser technology. For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized distributor.
Contact Information:

- Contact Person: Vivi (Ms.) Manager
- Email: vivi@demarkchina.com
- Wechat: +8613545735512
- Website: www.demarkchina.cn
When contacting support, please provide your product model number and a detailed description of the issue.