1. Introduction
The EPEVER ET-NC G3 series MPPT solar charge controller is designed for efficient and reliable solar energy management in various off-grid solar systems. It utilizes advanced Maximum Power Point Tracking (MPPT) technology to maximize energy harvest from photovoltaic (PV) arrays. This manual provides essential information for the safe and effective installation, operation, and maintenance of your ET-NC G3 solar charge controller.

Figure 1: EPEVER ET-NC G3 Series MPPT Charge Controller highlighting key features.
2. Key Features
- System Voltage: Supports 12V/24V/36V/48V DC systems with auto-detection.
- Charging Current: Available in 50A, 75A, and 100A models.
- MPPT Technology: Advanced MPPT tracking efficiency of ≥ 99.5% and maximum conversion efficiency of 98.5%.
- Dual PV Inputs: Equipped with two independent PV inputs for flexible solar array configurations.
- Battery Compatibility: Compatible with various battery types including AGM (Default), Gel, Flooded, and user-defined settings for lead-acid batteries, as well as LiFePO4 and Li(NiCoMn)O2 for lithium batteries.
- Robust Design: All-metal die-casting shell with IP43 enclosure rating (controller & white terminal cover) for enhanced durability and protection.
- Constant Voltage Output: Features a constant voltage output function to enable direct load supply when sufficient PV energy is available.
- Communication Interfaces:
- CAN: Supports parallel operation of up to 6 devices, with or without batteries.
- BMS: Built-in communication for reliable lithium battery charge/discharge management.
- RS485: For external communication, supporting optional Bluetooth, WiFi, or 4G modules for remote monitoring and control.

Figure 2: Overview of EPEVER MPPT Charge Controller features.
3. Installation and Setup
Proper installation is crucial for the safe and efficient operation of your solar charge controller. Please follow these guidelines carefully.
3.1 Mounting the Controller
Mount the controller in a well-ventilated area, away from direct sunlight, high temperatures, and moisture. Ensure there is sufficient clearance around the controller for heat dissipation. The enclosure rating is IP43 (with white terminal cover) or IP32 (controller only).
- Refer to the "Mechanical Parameters" in the Specifications section for mounting dimensions and hole sizes.
- Use appropriate fasteners for your mounting surface.

Figure 3: Front view of the ET-NC G3 controller, showing PV and Battery terminals.
3.2 Wiring Connections
Connect the components in the following order to ensure safety:
- Connect the Battery: Connect the battery to the controller's battery terminals. Ensure correct polarity. The controller will auto-detect the system voltage (12V/24V/48V).
- Connect the PV Array: Connect the solar panels to the controller's PV input terminals (PV1 and PV2). Ensure correct polarity and that the PV open-circuit voltage does not exceed the maximum allowed voltage (200V at lowest temperature, 180V at 25℃).
- Connect Loads (Optional): If using the constant voltage output function, connect your DC loads to the designated load terminals.
Important: Always connect the battery first, then the solar panels. Disconnect in the reverse order (PV first, then battery).

Figure 4: Connection diagram for dual PV inputs (PV1 and PV2).
3.3 Battery Type Configuration
The controller supports various battery types. The default setting is AGM. If you are using a different battery type (Gel, Flooded, LiFePO4, Li(NiCoMn)O2, or user-defined), you must configure the controller accordingly. Refer to the detailed user manual (PDF) for specific steps on how to change battery settings via the controller's display or communication interface.
3.4 Parallel Operation (CAN Communication)
The ET-NC G3 series supports parallel operation of up to 6 devices using CAN communication. This allows for scalable solar solutions to meet higher power demands.

Figure 5: CAN communication setup for parallel operation of multiple ET-NC G3 controllers.
3.5 BMS Communication
For lithium battery systems, the built-in BMS communication ensures reliable charge and discharge management, protecting the battery and optimizing its lifespan.

Figure 6: BMS communication setup for lithium battery systems.
4. Operating Instructions
Once installed and configured, the ET-NC G3 controller operates automatically to manage solar charging.
4.1 Power-Up Sequence
After connecting the battery and PV array, the controller will power up and begin its charging process. The LCD display will show real-time system information.
4.2 Monitoring and Control (RS485)
The controller features an RS485 communication port, allowing connection to optional Bluetooth, WiFi, or 4G modules. These modules enable remote monitoring and control of your solar system via a dedicated mobile application or PC software.

Figure 7: Remote monitoring via mobile app using RS485 communication modules.
4.3 Constant Voltage Output Function
The controller can provide a constant voltage output to directly power DC loads when there is sufficient PV energy, reducing reliance on battery discharge.

Figure 8: Illustration of the constant voltage output function.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your solar charge controller.
- Visual Inspection: Periodically check for any loose connections, damaged wiring, or signs of corrosion.
- Cleaning: Keep the controller's casing and ventilation openings clean and free from dust and debris to ensure proper heat dissipation.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your controller has the latest features and bug fixes.
- Battery Health: Monitor battery voltage and health regularly, especially if using user-defined battery settings.
6. Troubleshooting
This section provides general guidance for common issues. For detailed troubleshooting, please refer to the comprehensive product manual available from EPEVER.
- No Power/Display: Check battery connections and voltage. Ensure the battery is adequately charged.
- No Charging: Verify PV array connections and ensure solar panels are receiving sufficient sunlight. Check PV open-circuit voltage.
- Overcharging/Undercharging: Confirm that the correct battery type is selected in the controller settings.
- Communication Issues: Ensure communication modules are correctly installed and configured. Check cable connections.
7. Specifications
| Parameter | ET5420NC G3 | ET7420NC G3 | ET10420NC G3 |
|---|---|---|---|
| Electrical Parameters | |||
| Battery Rated Voltage | 12/24/48VDC or Auto | ||
| Controller Operating Voltage Range | 8–62V | ||
| Battery Type | AGM (Default) / Gel / Flooded / User | ||
| Lithium Battery Type | LiFePO4 / Li (NiCoMn)O2 / User | ||
| Rated Charging/Discharging Current | 50A | 75A | 100A |
| Rated Charging Power | 650W/12V; 1,300W/24V; 2,600W/48V | 975W/12V; 1,950W/24V; 3,900W/48V | 1,300W/12V; 2,600W/24V; 5,200W/48V |
| Maximum Charging Power | 650W/12V; 1,300W/24V; 2,600W/48V | 975W/12V; 1,950W/24V; 3,900W/48V | 1,300W/12V; 2,600W/24V; 5,200W/48V |
| PV Maximum Open-circuit Voltage | 200V (@ lowest temperature); 180V (@ 25℃) | ||
| MPPT Operating Voltage Range | (Battery voltage plus 2V, and > 28V) to 144V (@ 25 ℃) | ||
| Tracking Efficiency | ≥ 99.5% | ||
| Maximum Conversion Efficiency | 98.3% | 98.1% | 98.5% |
| Temperature Compensation Coefficient | -3mV/℃/2V (Default) | ||
| Self-consumption (Enabled Communication) | 98mA/12V; 60mA/24V; 46mA/48V | ||
| Self-consumption (Disabled Communication) | 48mA/12V; 25mA/24V; 14mA/48V | ||
| Grounding Type | Common negative grounding | ||
| Dry Contact (Oil Generator) | Rated value: 5A/30VDC; Maximum value: 0.5A/60VDC | ||
| RS485 Communication Port | 5VDC/200mA (RJ45) | ||
| Mechanical Parameters | |||
| Dimension (L×W×H) IP43 (Controller & White Terminal Cover) | 307 × 253 ×143mm | 320 × 263 ×158mm | 352 × 263 ×158mm |
| Dimension (L×W×H) IP32 (Controller Only) | 307 × 202 ×134mm | 320 × 212 ×149mm | 352 × 212 ×149mm |
| Mounting Dimension (L×W) | 295 × 130mm | 308 × 140mm | 340 × 140mm |
| Mounting Hole Size | Φ7mm | ||
| Wiring Terminal | 6AWG/16mm2 | 2AWG/35mm2 | 2AWG/35mm2 |
| Recommended Cable | 6AWG/16mm2 | 4AWG/25mm2 | 2AWG/35mm2 |
| Net Weight IP43 (Controller & White Terminal Cover) | 5.00Kg | 6.55Kg | 7.79kg |
| Net Weight IP32 (Controller Only) | 4.79Kg | 6.33Kg | 7.55kg |
| Environmental Parameters | |||
| Operating Temperature Range | -25℃ to +60℃ (Derating when temperature is higher than 40℃) | ||
| LCD temperature range | -20℃ to +70℃ | ||
| Storage Temperature Range | -30℃ to +70℃ | ||
| Relative Humidity | 5%–95% (N.C) | ||
| Altitude | < 5,000M (Derating when altitude is higher than 2,000m) | ||
| Enclosure | IP43 (Controller & White Terminal Cover); IP32 (Controller Only) | ||
| Pollution Degree | PD2 | ||
| Certification | |||
| Safety | EN/IEC62109-1 | ||
| EMC | EN61000-6-1 / EN61000-6-3 | ||
| FCC | 47 CFR Part 15, Subpart B | ||
| ROHS | IEC62321-3-1 | ||
8. User Tips
Based on general user feedback for solar charge controllers:
- Always ensure proper ventilation around the controller to prevent overheating, especially in warmer climates.
- Double-check all wiring connections for tightness and correct polarity before powering on the system. Loose connections can lead to poor performance or damage.
- If using lithium batteries, ensure the BMS communication is correctly set up and functioning to protect the battery.
- Utilize the remote monitoring features (via optional modules) to keep track of your system's performance and identify potential issues early.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized EPEVER dealer or visit the official EPEVER website. Keep your purchase receipt as proof of purchase for warranty claims.