1. Introduction
The Mastfuyi FY382C is a fully automatic, True RMS digital clamp meter designed for both beginners and professionals. It offers a wide range of measurement functions including AC/DC voltage, AC current, resistance, capacitance, frequency, temperature, continuity, and diode testing. Equipped with advanced safety features like NCV detection and anti-burn protection, along with a user-friendly color screen and Type-C charging, the FY382C provides reliable and efficient electrical diagnostics.
2. Safety Information
Please read and understand all safety warnings and operating instructions before using this instrument. Failure to do so may result in injury or damage to the meter or equipment under test.
- Always ensure the meter is in the correct function and range before making measurements.
- Do not exceed the maximum input values for any function.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Inspect test leads for damaged insulation or exposed metal before use. Replace if damaged.
- Do not operate the meter if it appears damaged or if the case is open.
- Keep fingers behind the finger guards on the test leads during measurements.
- When using the clamp jaw, ensure the circuit is de-energized if possible, and always wear appropriate personal protective equipment.
Safety Features:
- Full-Range Overload Protection (Anti-Burn): Withstands up to 250V even if the meter is set to an incorrect range, protecting the device from accidental damage.
- Non-Contact Voltage (NCV) Detection: Provides a safer way to detect AC voltage without direct contact. The device emits beeps that vary in intensity according to the voltage level.
- Live/Neutral Wire Identification: Helps distinguish between live and neutral wires for safer testing.



3. Package Contents
Verify that all items are present and in good condition upon unpacking:
- 1 x Mastfuyi FY382C Digital Clamp Meter
- 2 x Measuring Pens (Test Leads)
- 1 x Thermocouple (for temperature measurement)
- 1 x Storage Bag
- 1 x User Manual (this document)
- 1 x USB Type-C Charging Cable

4. Key Features
- Extensive Current Measurement: Measures AC current from 100mA to 600A with a 30mm jaw opening, suitable for various industrial and household applications.
- True RMS: Provides accurate measurements for non-sinusoidal AC waveforms.
- Multi-Parameter Testing: Supports AC/DC voltage (100mV-600V), resistance (0.1Ω-60MΩ), capacitance (0.001nF-60mF), frequency (0.01Hz-999.9Hz), temperature (-20℃~1000℃ / -4℉~1832℉), continuity, and diode tests.
- Dual Display: Shows current and frequency simultaneously while measuring current.
- VFC (Voltage Frequency Control): Function for accurate measurements on variable frequency drives and other frequency-driven devices.
- User-Friendly Design: Features a color LCD screen, intuitive 'LIVE' mode, data hold, auto/manual ranging, auto power-off, flashlight, and low battery indication.
- Rechargeable Battery: Powered by a 3.7V 900mAh Lithium Battery with convenient USB Type-C charging (5V/1A).


5. Setup
5.1 Charging the Battery
The FY382C is equipped with a built-in 3.7V 900mAh Lithium Battery. Before first use, or when the low battery indicator appears, charge the device using the provided USB Type-C cable.
- Connect the USB Type-C charging cable to the meter's charging port.
- Connect the other end of the cable to a standard USB power adapter (5V/1A recommended) or a computer USB port.
- The charging indicator on the meter will show the charging status.
- Once fully charged, disconnect the cable.
5.2 Connecting Test Leads
For voltage, resistance, capacitance, frequency, continuity, diode, and temperature measurements, connect the test leads as follows:
- Insert the red test lead into the 'INPUT' jack.
- Insert the black test lead into the 'COM' (common) jack.
- For temperature measurements, connect the thermocouple to the designated ports, ensuring correct polarity.
6. Operating Modes
The FY382C features a fully automatic mode, simplifying operation. You can also manually select specific functions using the 'SEL' button.
6.1 Power On/Off
- Press the power button (
) to turn the meter on. - The meter will typically start in Auto mode.
- Press and hold the power button to turn the meter off. The meter also features an auto power-off function to conserve battery.
6.2 AC Current Measurement (Clamp Jaw)
Use the clamp jaw for non-contact AC current measurement.
- Rotate the dial to the current measurement function (usually indicated by 'A' or a waveform symbol).
- Open the clamp jaw by pressing the trigger.
- Enclose a single conductor (not a bundle of wires) within the clamp jaw.
- Read the AC current value and frequency on the dual display.

6.3 AC/DC Voltage Measurement
- Connect the test leads to the 'INPUT' and 'COM' jacks.
- Rotate the dial to the voltage measurement function (V). The meter will automatically detect AC or DC voltage in Auto mode.
- Touch the test probes to the circuit points where you want to measure voltage.
- Read the voltage value on the display.
6.4 Resistance Measurement
- Connect the test leads to the 'INPUT' and 'COM' jacks.
- Rotate the dial to the resistance function (Ω).
- Ensure the circuit is de-energized before measuring resistance.
- Touch the test probes across the component or circuit path.
- Read the resistance value on the display.
6.5 Capacitance Measurement
- Connect the test leads to the 'INPUT' and 'COM' jacks.
- Rotate the dial to the capacitance function (F).
- Ensure the capacitor is fully discharged before measurement.
- Touch the test probes to the capacitor terminals.
- Read the capacitance value on the display.
6.6 Frequency Measurement (Hz)
- Connect the test leads to the 'INPUT' and 'COM' jacks.
- Rotate the dial to the frequency function (Hz).
- Touch the test probes to the circuit points where you want to measure frequency.
- Read the frequency value on the display.
6.7 Temperature Measurement
- Connect the thermocouple to the designated ports on the meter.
- Rotate the dial to the temperature function (℃/℉).
- Place the thermocouple probe on or near the object whose temperature you wish to measure.
- Read the temperature value on the display.
6.8 Continuity Test
- Connect the test leads to the 'INPUT' and 'COM' jacks.
- Rotate the dial to the continuity function (usually shared with diode).
- Ensure the circuit is de-energized.
- Touch the test probes across the component or circuit path.
- If there is continuity (low resistance), the meter will emit an audible beep.
6.9 Diode Test
- Connect the test leads to the 'INPUT' and 'COM' jacks.
- Rotate the dial to the diode function (usually shared with continuity).
- Ensure the diode is disconnected from the circuit.
- Touch the red probe to the anode and the black probe to the cathode. The display will show the forward voltage drop.
- Reverse the probes. The display should show 'OL' (open loop) for a good diode.
6.10 NCV (Non-Contact Voltage) Detection
- Rotate the dial to the NCV function.
- Move the top of the clamp meter near the conductor or outlet.
- The meter will beep and the NCV indicator will light up with varying intensity depending on the detected voltage.
6.11 LIVE Wire Detection
- Connect a single test lead (typically the red one) to the 'INPUT' jack.
- Rotate the dial to the 'LIVE' mode.
- Insert the test lead into a socket or touch it to a conductor.
- If inserted into the neutral wire, the device shows no response. If inserted into the live wire, the device emits a rapid beep and indicates 'LIVE' on the display.
6.12 Data Hold
Press the 'HOLD' button to freeze the current reading on the display. Press it again to release.
6.13 Flashlight
The meter includes a built-in flashlight for illuminating dark work areas. Refer to the meter's buttons for flashlight activation (often a dedicated button or a long press of another function button).
7. Maintenance
7.1 Cleaning
- Wipe the meter's case with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Keep the display clean and free from dust.
- Ensure the test leads and input jacks are clean and free from debris.
7.2 Storage
- When not in use, store the meter in its storage bag to protect it from dust and physical damage.
- Store in a cool, dry place, away from direct sunlight and extreme temperatures.
- If storing for an extended period, ensure the battery is partially charged (not fully depleted or fully charged) to prolong its lifespan.
7.3 Battery Care
- Recharge the battery when the low battery indicator appears.
- Avoid completely draining the battery frequently.
- Use only the provided Type-C charging cable or a compatible 5V/1A charger.
8. Troubleshooting
If the meter is not functioning correctly, try the following:
- No display or erratic readings: Check battery charge level and recharge if necessary.
- Incorrect readings: Ensure test leads are properly connected and not damaged. Verify the correct function and range are selected for the measurement. Ensure the circuit is de-energized for resistance, continuity, and diode tests.
- Meter does not turn on: Ensure the battery is charged.
- No continuity beep: Check if the circuit is truly continuous and if the resistance is within the meter's threshold for continuity.
- NCV not detecting: Ensure the NCV sensor is close enough to the AC voltage source.
If problems persist, contact customer support for assistance.
9. Specifications
| Parameter | Specification (FY382C) |
|---|---|
| Color | Black |
| Material | Plastic |
| Screen | LCD Color Screen |
| True RMS | Yes |
| Count | 6000 Counts |
| Tong Head Opening | 30mm |
| AC Current | 100mA-600A |
| AC/DC Voltage | 100mV-600V |
| VFC Voltage | 100mV-600V |
| Resistance | 0.1Ω-60MΩ |
| Capacitance | 0.001nF-60mF |
| Frequency | 0.01Hz-999.9Hz |
| Temperature Range | -20℃~1000℃ / -4℉~1832℉ |
| Continuity | Yes |
| Diode | Yes |
| NCV | Yes |
| Live Wire Mode | Yes |
| Data Hold | Yes |
| Zero Calibration | Yes |
| Auto Ranging | Yes |
| Auto Mode | Yes |
| Auto Power Off | Yes |
| Power Supply | 3.7V 900mAh Lithium Battery |
| Charging Specifications | USB Type-C, 5V/1A |
| Item Size | Approx. 195 * 74 * 30mm / 7.68 * 2.91 * 1.18in |
| Package Weight | Approx. 400g / 14.41oz |

10. User Tips
- For accurate current measurements, always ensure only one conductor passes through the clamp jaw. Measuring multiple conductors will result in a zero reading if currents are balanced.
- When measuring low AC currents, ensure the meter is set to the most sensitive range available for better resolution.
- Utilize the 'HOLD' function to capture readings in hard-to-reach or poorly lit areas.
- The color screen provides clear visibility in various lighting conditions, but avoid direct sunlight to prevent glare.
- Regularly charge your meter to ensure it's ready for use, especially before critical tasks.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or the official Mastfuyi website. Keep your purchase receipt as proof of purchase.