EPEVER UP3000-HM10021(RTU)

Contents

EPEVER UP3000-HM10021(RTU) Solar Inverter User Manual

Model: UP3000-HM10021(RTU)

Brand: EPEVER

1. Introduction

The EPEVER UPower-Hi Series inverter/charger is an advanced energy management device designed for solar, utility, and generator power supply to AC loads. It optimizes solar energy utilization by allowing users to choose energy sources based on actual needs, supplementing power as required. This inverter/charger is suitable for solar energy, utility/oil generator hybrid systems, offering high-quality, high-stability, and high-reliability electrical energy.

Front view of the EPEVER UP3000-HM10021(RTU) inverter/charger, highlighting 100A battery charging current and 24VDC rated battery voltage.
Front view of the EPEVER UP3000-HM10021(RTU) inverter/charger, highlighting 100A battery charging current and 24VDC rated battery voltage.

2. Safety Instructions

Please read all instructions and warnings in this manual carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

  • Ensure all wiring is performed by qualified personnel.
  • Do not disassemble or attempt to repair the inverter/charger yourself.
  • Keep the device away from water, moisture, and flammable materials.
  • Ensure proper ventilation around the unit to prevent overheating.
  • Always disconnect power sources before performing any maintenance or wiring.
  • Use appropriate personal protective equipment (PPE) during installation.

3. Product Overview

3.1 Features

Overview and Features of the EPEVER UPower-Hi Series inverter/charger, detailing its capabilities and key functionalities.
Overview and Features of the EPEVER UPower-Hi Series inverter/charger.
  • Supports both battery mode and non-battery mode operation.
  • Integrated surge current and reverse connection protections for lithium battery systems.
  • Three charging modes: Solar Only, Solar Priority, and Utility & Solar.
  • Two AC output modes: Utility Priority and Inverter Priority.
  • High tracking efficiency of MPPT, no less than 99.5%.
  • PFC technology for high power factor AC to DC charging, reducing power grid capacity requirements.
  • Advanced SPWM technology and pure sine wave output.
  • Configurable battery charging current and discharging current.
  • Configurable grid charging current.
  • Self-learning SOC function.
  • 4.2-inch LCD for monitoring and modifying system parameters.
  • Optional WiFi or GPRS Remote control via the RS485 isolated communication port.
  • BMS-Link port and optional BMS-Link communication protocol module.

3.2 Components

Rear panel connections of the EPEVER UP3000-HM10021(RTU) inverter, showing AC input, AC output, DC input, and WiFi/GPRS port.
Rear panel connections of the EPEVER UP3000-HM10021(RTU) inverter.

The inverter/charger features a robust design with clearly labeled connection points:

  • Front Panel: LCD display for system status and parameter settings, control buttons.
  • Rear Panel:
    • AC Input: Terminals for connecting the utility grid or generator AC power (N, L, N+).
    • AC Output: Terminals for connecting AC loads (N, L, N+).
    • DC Input: Terminals for connecting battery bank (DC INPUT) and solar PV array (DC INPUT).
    • WiFi/GPRS Port: For optional remote monitoring modules.
    • Ventilation Grilles: Located on the sides for heat dissipation.

4. Setup

Proper installation is crucial for the safe and efficient operation of your EPEVER inverter/charger. Always follow local electrical codes and safety regulations.

4.1 Mounting

  • Choose a dry, well-ventilated area, protected from direct sunlight, high temperatures, and moisture.
  • Mount the inverter vertically on a non-flammable surface, ensuring sufficient clearance around the unit for air circulation (refer to the ventilation grilles on the sides).
  • Use appropriate mounting hardware to secure the unit firmly.

4.2 Wiring Connections

Refer to the rear panel diagram (Figure 3.2) for connection points.

  1. Battery Connection: Connect the battery bank to the DC INPUT terminals. Ensure correct polarity (positive to positive, negative to negative). Use appropriately sized cables and fuses. The inverter supports a 24VDC rated battery voltage.
  2. Solar PV Array Connection: Connect the solar PV array to the DC INPUT terminals. Observe correct polarity and ensure the open-circuit voltage of the PV array does not exceed the maximum input voltage specified in the technical specifications.
  3. AC Input Connection: Connect the utility grid or generator AC power to the AC INPUT terminals (N, L, N+).
  4. AC Output Connection: Connect your AC loads to the AC OUTPUT terminals (N, L, N+).
  5. Grounding: Ensure the inverter chassis is properly grounded according to local electrical codes.
  6. Optional Communication: If using remote monitoring, connect the WiFi or GPRS module to the designated port.

WARNING: Incorrect wiring can cause severe damage to the inverter, batteries, and connected loads, and poses a risk of electric shock or fire. Double-check all connections before applying power.

5. Operating Instructions

Once installed and wired correctly, the inverter/charger can be configured and operated via its 4.2-inch LCD display and control buttons.

5.1 Initial Power-Up

  1. Ensure all connections are secure.
  2. Turn on the battery breaker.
  3. Turn on the solar PV array breaker (if applicable).
  4. Turn on the AC input breaker (if connected to utility/generator).
  5. The inverter will initiate and the LCD will display system status.

5.2 LCD Display and Navigation

The LCD provides real-time data on battery status, solar input, AC input/output, and load. Use the control buttons to navigate through menus and adjust settings.

5.3 Charging Modes

The inverter offers three configurable charging modes:

  • Solar Only: Prioritizes solar power for battery charging.
  • Solar Priority: Uses solar power first, then supplements with utility/generator if solar is insufficient.
  • Utility & Solar: Uses both utility/generator and solar power for charging.

5.4 AC Output Modes

The inverter supports two AC output modes:

  • Utility Priority: AC loads are primarily powered by the utility grid/generator. The inverter provides power only when the utility is unavailable or insufficient.
  • Inverter Priority: AC loads are primarily powered by the inverter (from batteries/solar). The utility grid/generator acts as a backup.

5.5 Parameter Configuration

Through the LCD menu, you can configure various parameters such as battery type, charging current limits (100A max for this model), discharging current limits, and grid charging current. Refer to the detailed user manual (if available) for specific menu navigation and parameter descriptions.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter/charger.

  • Cleaning: Periodically clean the exterior of the inverter, especially the ventilation grilles, to prevent dust buildup. Use a dry, soft cloth. Do not use liquid cleaners.
  • Connections Check: Annually inspect all electrical connections for tightness and corrosion. Re-tighten if necessary.
  • Battery Inspection: Follow the maintenance guidelines for your specific battery type. Ensure battery terminals are clean and free of corrosion.
  • Environmental Check: Ensure the installation environment remains within the specified temperature and humidity ranges.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates for improved performance or new features.

7. Troubleshooting

This section provides general guidance for common issues. For complex problems, contact technical support.

  • No Power Output: Check battery connections, battery voltage, AC input connection (if applicable), and all circuit breakers/fuses.
  • Inverter Overheating: Ensure adequate ventilation. Clean any dust from the cooling fins. Reduce load if continuously overloaded.
  • Low Battery Voltage Alarm: Check battery health and charging sources (solar, utility). Ensure charging parameters are correctly set.
  • Abnormal LCD Display: Try restarting the inverter. If the issue persists, contact support.
  • No Solar Charging: Check PV array connections, ensure PV voltage is within the inverter's operating range, and verify solar charging mode settings.

8. Specifications

The following table details the technical specifications for the EPEVER UP3000-HM10021(RTU) model.

Technical Specifications table for EPEVER UP3000-HM10021 and other models, including battery voltage, inverter output, solar charging, and mechanical parameters.
Technical Specifications for EPEVER UPower-Hi Series.
ItemUP3000-HM10021
Rated battery voltage24VDC
Battery input voltage range21.6~32VDC
Max. battery charging current100A
Inverter output
Continuous output power3000W
Max. surge power (3S)6000W
Output voltage range110VAC (3%~+3%), 120VAC (10%~+3%)
Output frequency50/60±0.2Hz
Output wavePure Sine Wave
Load power factor0.2-1 (Load power ≤ Continuous output power)
Distortion THDTHD≤5% (Resistive load)
Max. output efficiency92%
Max. rated output efficiency92%
Switch time10ms (Switch from the utility output to the inverter output), 15ms (Switch from the inverter output to the utility output)
Utility charging
Utility input voltage88VAC~132VAC (Default), 80VAC~140VAC (Programmable)
Utility input frequency40~65Hz
Max. utility charging current80A
Solar charging
Max. PV open circuit voltage250V (At minimum operating environment temperature), 220V (At 25°C environment temperature)
MPPT voltage range60~200V
Max. PV input power3000W
Max. PV charging current100A
Equalize charging voltage29.2V (AGM default)
Boost charging voltage28.8V (AGM default)
Float charging voltage27.6V (AGM default)
Low voltage disconnect voltage21.6V (AGM default)
Tracking efficiency≥99.5%
Temp. compensate coefficient-3mV/°C/2V (Default)
General
Surge current60A
Zero load consumption≤1.6A (without PV and utility connection, turn on the load output)
Standby current≤1.0A (without PV and utility connection, turn off the load output)
Mechanical Parameters
Dimension (H x W x D)620*300mm
Mounting size585*300mm
Mounting hole sizeΦ10mm
Net Weight19kg
EnclosureIP20
Relative humidity≤95% (N.C.)
Environment temperature-20°C~50°C

9. User Tips

  • Optimize Battery Settings: Carefully configure battery type and charging parameters to match your specific battery chemistry (e.g., AGM, Lithium) for optimal performance and lifespan.
  • Monitor Performance: Regularly check the LCD display for system status and performance metrics. Consider using the optional WiFi/GPRS module for remote monitoring.
  • Load Management: Be mindful of the inverter's continuous and surge power ratings to avoid overloading, especially with inductive loads.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt and product serial number handy when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.