The EPEVER UPower-Hi Series inverter/charger is an advanced energy management device designed for solar, utility, and generator power supply to AC loads. It optimizes solar energy utilization by allowing users to choose energy sources based on actual needs, supplementing power as required. This inverter/charger is suitable for solar energy, utility/oil generator hybrid systems, offering high-quality, high-stability, and high-reliability electrical energy.

2. Safety Instructions
Please read all instructions and warnings in this manual carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.
- Ensure all wiring is performed by qualified personnel.
- Do not disassemble or attempt to repair the inverter/charger yourself.
- Keep the device away from water, moisture, and flammable materials.
- Ensure proper ventilation around the unit to prevent overheating.
- Always disconnect power sources before performing any maintenance or wiring.
- Use appropriate personal protective equipment (PPE) during installation.
3. Product Overview
3.1 Features

- Supports both battery mode and non-battery mode operation.
- Integrated surge current and reverse connection protections for lithium battery systems.
- Three charging modes: Solar Only, Solar Priority, and Utility & Solar.
- Two AC output modes: Utility Priority and Inverter Priority.
- High tracking efficiency of MPPT, no less than 99.5%.
- PFC technology for high power factor AC to DC charging, reducing power grid capacity requirements.
- Advanced SPWM technology and pure sine wave output.
- Configurable battery charging current and discharging current.
- Configurable grid charging current.
- Self-learning SOC function.
- 4.2-inch LCD for monitoring and modifying system parameters.
- Optional WiFi or GPRS Remote control via the RS485 isolated communication port.
- BMS-Link port and optional BMS-Link communication protocol module.
3.2 Components

The inverter/charger features a robust design with clearly labeled connection points:
- Front Panel: LCD display for system status and parameter settings, control buttons.
- Rear Panel:
- AC Input: Terminals for connecting the utility grid or generator AC power (N, L, N+).
- AC Output: Terminals for connecting AC loads (N, L, N+).
- DC Input: Terminals for connecting battery bank (DC INPUT) and solar PV array (DC INPUT).
- WiFi/GPRS Port: For optional remote monitoring modules.
- Ventilation Grilles: Located on the sides for heat dissipation.
4. Setup
Proper installation is crucial for the safe and efficient operation of your EPEVER inverter/charger. Always follow local electrical codes and safety regulations.
4.1 Mounting
- Choose a dry, well-ventilated area, protected from direct sunlight, high temperatures, and moisture.
- Mount the inverter vertically on a non-flammable surface, ensuring sufficient clearance around the unit for air circulation (refer to the ventilation grilles on the sides).
- Use appropriate mounting hardware to secure the unit firmly.
4.2 Wiring Connections
Refer to the rear panel diagram (Figure 3.2) for connection points.
- Battery Connection: Connect the battery bank to the DC INPUT terminals. Ensure correct polarity (positive to positive, negative to negative). Use appropriately sized cables and fuses. The inverter supports a 24VDC rated battery voltage.
- Solar PV Array Connection: Connect the solar PV array to the DC INPUT terminals. Observe correct polarity and ensure the open-circuit voltage of the PV array does not exceed the maximum input voltage specified in the technical specifications.
- AC Input Connection: Connect the utility grid or generator AC power to the AC INPUT terminals (N, L, N+).
- AC Output Connection: Connect your AC loads to the AC OUTPUT terminals (N, L, N+).
- Grounding: Ensure the inverter chassis is properly grounded according to local electrical codes.
- Optional Communication: If using remote monitoring, connect the WiFi or GPRS module to the designated port.
WARNING: Incorrect wiring can cause severe damage to the inverter, batteries, and connected loads, and poses a risk of electric shock or fire. Double-check all connections before applying power.
5. Operating Instructions
Once installed and wired correctly, the inverter/charger can be configured and operated via its 4.2-inch LCD display and control buttons.
5.1 Initial Power-Up
- Ensure all connections are secure.
- Turn on the battery breaker.
- Turn on the solar PV array breaker (if applicable).
- Turn on the AC input breaker (if connected to utility/generator).
- The inverter will initiate and the LCD will display system status.
5.2 LCD Display and Navigation
The LCD provides real-time data on battery status, solar input, AC input/output, and load. Use the control buttons to navigate through menus and adjust settings.
5.3 Charging Modes
The inverter offers three configurable charging modes:
- Solar Only: Prioritizes solar power for battery charging.
- Solar Priority: Uses solar power first, then supplements with utility/generator if solar is insufficient.
- Utility & Solar: Uses both utility/generator and solar power for charging.
5.4 AC Output Modes
The inverter supports two AC output modes:
- Utility Priority: AC loads are primarily powered by the utility grid/generator. The inverter provides power only when the utility is unavailable or insufficient.
- Inverter Priority: AC loads are primarily powered by the inverter (from batteries/solar). The utility grid/generator acts as a backup.
5.5 Parameter Configuration
Through the LCD menu, you can configure various parameters such as battery type, charging current limits (100A max for this model), discharging current limits, and grid charging current. Refer to the detailed user manual (if available) for specific menu navigation and parameter descriptions.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter/charger.
- Cleaning: Periodically clean the exterior of the inverter, especially the ventilation grilles, to prevent dust buildup. Use a dry, soft cloth. Do not use liquid cleaners.
- Connections Check: Annually inspect all electrical connections for tightness and corrosion. Re-tighten if necessary.
- Battery Inspection: Follow the maintenance guidelines for your specific battery type. Ensure battery terminals are clean and free of corrosion.
- Environmental Check: Ensure the installation environment remains within the specified temperature and humidity ranges.
- Firmware Updates: Check the manufacturer's website for any available firmware updates for improved performance or new features.
7. Troubleshooting
This section provides general guidance for common issues. For complex problems, contact technical support.
- No Power Output: Check battery connections, battery voltage, AC input connection (if applicable), and all circuit breakers/fuses.
- Inverter Overheating: Ensure adequate ventilation. Clean any dust from the cooling fins. Reduce load if continuously overloaded.
- Low Battery Voltage Alarm: Check battery health and charging sources (solar, utility). Ensure charging parameters are correctly set.
- Abnormal LCD Display: Try restarting the inverter. If the issue persists, contact support.
- No Solar Charging: Check PV array connections, ensure PV voltage is within the inverter's operating range, and verify solar charging mode settings.
8. Specifications
The following table details the technical specifications for the EPEVER UP3000-HM10021(RTU) model.

| Item | UP3000-HM10021 |
|---|---|
| Rated battery voltage | 24VDC |
| Battery input voltage range | 21.6~32VDC |
| Max. battery charging current | 100A |
| Inverter output | |
| Continuous output power | 3000W |
| Max. surge power (3S) | 6000W |
| Output voltage range | 110VAC (3%~+3%), 120VAC (10%~+3%) |
| Output frequency | 50/60±0.2Hz |
| Output wave | Pure Sine Wave |
| Load power factor | 0.2-1 (Load power ≤ Continuous output power) |
| Distortion THD | THD≤5% (Resistive load) |
| Max. output efficiency | 92% |
| Max. rated output efficiency | 92% |
| Switch time | 10ms (Switch from the utility output to the inverter output), 15ms (Switch from the inverter output to the utility output) |
| Utility charging | |
| Utility input voltage | 88VAC~132VAC (Default), 80VAC~140VAC (Programmable) |
| Utility input frequency | 40~65Hz |
| Max. utility charging current | 80A |
| Solar charging | |
| Max. PV open circuit voltage | 250V (At minimum operating environment temperature), 220V (At 25°C environment temperature) |
| MPPT voltage range | 60~200V |
| Max. PV input power | 3000W |
| Max. PV charging current | 100A |
| Equalize charging voltage | 29.2V (AGM default) |
| Boost charging voltage | 28.8V (AGM default) |
| Float charging voltage | 27.6V (AGM default) |
| Low voltage disconnect voltage | 21.6V (AGM default) |
| Tracking efficiency | ≥99.5% |
| Temp. compensate coefficient | -3mV/°C/2V (Default) |
| General | |
| Surge current | 60A |
| Zero load consumption | ≤1.6A (without PV and utility connection, turn on the load output) |
| Standby current | ≤1.0A (without PV and utility connection, turn off the load output) |
| Mechanical Parameters | |
| Dimension (H x W x D) | 620*300mm |
| Mounting size | 585*300mm |
| Mounting hole size | Φ10mm |
| Net Weight | 19kg |
| Enclosure | IP20 |
| Relative humidity | ≤95% (N.C.) |
| Environment temperature | -20°C~50°C |
9. User Tips
- Optimize Battery Settings: Carefully configure battery type and charging parameters to match your specific battery chemistry (e.g., AGM, Lithium) for optimal performance and lifespan.
- Monitor Performance: Regularly check the LCD display for system status and performance metrics. Consider using the optional WiFi/GPRS module for remote monitoring.
- Load Management: Be mindful of the inverter's continuous and surge power ratings to avoid overloading, especially with inductive loads.
10. Warranty and Support