SucceBuy 15L Digital Ultrasonic Cleaner

SucceBuy 15L Digital Ultrasonic Cleaner

Instruction Manual

Model: 15L Digital Ultrasonic Cleaner | Brand: SucceBuy

1. Introduction

Thank you for purchasing the SucceBuy Ultrasonic Cleaner. This manual provides essential information for the safe and efficient operation of your device. Please read it thoroughly before use and retain it for future reference.

General Safety Cautions

  • Ensure the power supply is within the rated range before connecting the power cable. Refitting is strictly prohibited. The control panel may be eroded by organic solutions, strong acids, and strong alkalis.
  • Ensure the earth wiring is well connected before starting.
  • Ensure the power key or knob is in the 'OFF' position before starting.
  • Do not operate if the tank is empty, as the ultrasonic generator may be damaged. If heating is needed, the water level should not be less than 2/3 of the tank capacity.
  • Please close the lid to reduce noise and pay attention to water and steam to avoid burning skin when opening the lid.
  • Do not relocate the machine when fluid is in the tank to prevent overflow.
  • Only use water-soluble liquids suitable for benchtop ultrasonic cleaners. Strong acid or flammable cleaners are forbidden.
  • Do not use the machine in severe environments such as:
    • Places where temperature changes fiercely.
    • Places where humidity is too high and is prone to condensation.
    • Places where vibration or impact is strong.
    • Places where corrosive gas or dust exists.
    • Places where water, oil, or chemicals may splash.
    • Places filled with explosive and flammable gas.
  • Shorten the daily working time. It is suggested to stop for a few minutes for heat dissipation after working over 30 minutes.

Important Note: Heater is forbidden when using flammable liquid (such as alcohol, solvent cleaner etc.) to clean objects. Cleaning effect will be much better if using the machine together with proper solvent.

2. Product Overview

The SucceBuy 15L Digital Ultrasonic Cleaner is designed for effective cleaning of various items using advanced ultrasonic technology.

Components and Features

SucceBuy 15L Digital Ultrasonic Cleaner
The SucceBuy 15L Digital Ultrasonic Cleaner, featuring a stainless steel tank, digital control panel, and a cleaning basket. A power cord is also shown.
A short demonstration showcasing the features and cleaning capabilities of the VEVOR Digital Ultrasonic Cleaner, including adding water, using the cleaning basket, operating the digital control panel, and cleaning various items like glasses, jewelry, and watches.

Control Panel

Digital Control Panel Diagram
Detailed view of the digital control panel, indicating Temperature Display, Time Display, TEMP+ and TEMP- buttons for setting temperature (RT-80°C/RT-176°F), TIME+ and TIME- buttons for setting time (0-30min), and ON/OFF switches for heating and time functions.

Dimensions and Capacity

Cleaning Basket and Tank Size Dimensions
Diagrams illustrating the dimensions of the cleaning basket (11.4in/290mm L, 10.2in/258mm W, 3.3in/85mm H) and the 15L tank (13in/330mm L, 11.8in/300mm W, 5.9in/150mm H).
Product Overall Dimensions
An image detailing product specifications, including overall dimensions of the ultrasonic cleaner: 14in/355mm (Length), 12.8in/325mm (Width), and 11.4in/290mm (Height).

Advanced Technology

Advanced Transducer Technology
Illustration of the advanced transducer technology, highlighting the Sandwich Piezoelectric Transducer Structure, 360W Ultrasonic Power, 40KHz Ultrasonic Frequency, and Noise Reduction features.

Construction Details

Humanized Details of Ultrasonic Cleaner
Close-up views of the ultrasonic cleaner's humanized details, including heat dissipation holes for overheat protection, double fuses for electrical safety, a convenient drainage system, and four rubber foot pads for stability.

3. Technical Specifications

FeatureSpecification
Tank MaterialStainless Steel SUS304
Heating Power400W
Ultrasonic Power360W
Frequency40kHz
Power SupplyAC110V/60Hz
Tank Capacity13.5-15L (Actual volume may be smaller due to curved bottom)
Time Setting0 - 30 minutes (LED Digital Display)
Temperature SettingRT-176℉ / RT-80℃
Transducer Quantity6 sets
Tank Size (L x W x H)13 x 11.8 x 5.9 in / 330 x 300 x 150 mm
Product Size (L x W x H)14 x 12.8 x 11.4 in / 355 x 325 x 290 mm
Product Weight9.72 kg / 21.4 lbs
CertificationCE

4. Setup

  1. Unpack the unit and ensure all components are present and undamaged.
  2. Place the unit on a stable, flat working platform in a dry and cool environment.
  3. Ensure the earth wiring is properly connected.
  4. Add water or appropriate cleaning solution to the tank. The water level should be above 2/3 of the tank capacity but not overflowing.
  5. Connect the power cable to a grounded outlet.

Note: Ensure the unit is placed on a stable, flat surface in a dry and cool environment.

5. Operation Instructions

Digital Model Operation

  1. Power On: Ensure the power key is in the 'OFF' position. Connect the unit to power. The default time setting is "05:00".
  2. Time Setting: Press the 'TIME+' button to increase the cleaning time by 1 minute per press. Press the 'TIME-' button to decrease the cleaning time by 1 minute per press. The time range is 0-30 minutes.
  3. Temperature Setting (Heating): The default temperature setting is "50°C" and the actual temperature is displayed. Press 'TEMP+' to increase the temperature by 1°C per press. Press 'TEMP-' to decrease the temperature by 1°C per press. If the set temperature is lower than the actual tank temperature, the heating operation will stop automatically. The heating function is optional.
  4. Start Cleaning: After setting the desired time and temperature, press the 'ON/OFF' button (for time function) once to start the ultrasonic cleaning. The equipment will work automatically.
  5. Stop Cleaning: Press the 'ON/OFF' button (for time function) again to stop the work process.
  6. Power Off: Switch off the unit and disconnect the power supply.

Adjusting Power

This function is only available for power adjustable models. Rotate the power knob clockwise SLOWLY to increase the power from 40% to 100%, and counter-clockwise SLOWLY to decrease sonic power.

6. Maintenance

  • The unit must be opened by authorized specialized personnel only for maintenance and care.
  • Clean the contaminant in the tank frequently.
  • After use, empty out the liquid and clean the tank and the unit with a clean cloth for next use.

7. Troubleshooting

No.ProblemPossible CausesSolutions
1No ultrasonicA. Power supply not connected
B. Fuse broken
C. Cable short circuit
D. Transducer short circuit
E. PCB Board broken
F. Other reasons
A. Check and plug power switch.
B. Check the fitted power supply and change the same specification fuse.
C. Connect fitted cable or replace a new.
D. Inquiry our after service engineer.
E. Check the broken part and change it.
F. Inquiry our after service engineer.
2Time control failureA. Timer knob out of control
B. Timer failure
C. Other reasons
A. Loosen or tighten the screw.
B. Replace timer or digital panel.
C. Inquiry our after service engineer.
3No heatingA. Heater power switch bad linkage
B. Fuse burn out
C. Heating pad burn out
D. Digital display board out of control
E. Other reasons
A. Check heating plug and connect well, Check outlet line with multimeter: if OK and resistance value is few hundred OHMS.
B. Change the same specification fuse.
C. Replace the bad heating pad if open circuit.
D. Check the broken part and change it.
E. Inquiry our after service engineer.
4Temperature control failureA. Thermostat loosen
B. Thermostat tube broken
C. Digital display out of control
D. Other reasons
A. Fasten the thermostat header.
B. Replace thermostat.
C. Check the broken part and change it.
D. Inquiry our after service engineer.
5Not well cleaningA. Not strong ultrasonic cleaning
B. Too high too low liquid surface
C. Too high too low temperature
D. Not suitable cleaning liquid
E. Other reasons
A. Connect ultrasonic button and adjust.
B. Adjust liquid into the best surface.
C. Adjust temperature into the most fitted.
D. Stop and switch off power supply, replace suitable liquid after the previous liquid cool down.
E. Inquiry our after service engineer.
6Electric leakageA. Customer side not grounded
B. Machine not grounded
A. To ensure grounded.
B. Check if machine earth wire loosen.

8. Applications

The ultrasonic cleaner is suitable for a wide range of applications, both professional and household.

Versatile Uses of Ultrasonic Cleaner
A collage showing various items that can be cleaned with the ultrasonic cleaner, including jewelry, watches, tools, dental instruments, eyeglasses, and laboratory glassware.

Typical Items and Industries

  • Electronic Factory: PCB, integrated circuits, power tubes, silicon wafers, diodes, lead frames, capillaries, trays.
  • Car Workshops: Engine parts, fuel injectors, small components.
  • Industrial and Mining Area: Industrial parts, tools, small machinery components.
  • Laboratories: Lab instruments, glassware, optical devices, filters.
  • Hospitals & Dental Clinics: Medical instruments, dental tools, dentures.
  • Watch Shops: Watches, watch parts, jewelry.
  • Optical Shops: Eyeglasses, optical lenses, contact lens accessories.
  • Jewelry Shops: Jewelry, rings, necklaces, bracelets, diamonds.
  • Mobile Phone Repair Shops: Small electronic components, circuit boards.
  • Household Use: Cutlery, combs, toothbrushes, coins, small household items.

9. User Tips

For optimal cleaning results, always use appropriate cleaning solutions for the items being cleaned. Ensure items are fully submerged but not overcrowded in the cleaning basket. Regularly check the water level and replace the cleaning solution as needed for consistent performance.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official product documentation or contact the manufacturer's customer service.

A detailed user manual is available in PDF format: Download User Manual (PDF)

Related Documents - 15L Digital Ultrasonic Cleaner

Preview Pipe Inspection System Instruction Manual - SucceBuy
Comprehensive instruction manual for the SucceBuy Pipe Inspection System. Learn about its features, detailed specifications for various camera types (A, B, C) and monitor options, system installation, and charging procedures. Ideal for inspecting pipes, drains, and hard-to-reach areas.
Preview VEVOR Ultrasonic Cleaner: Instruction Manual and Specifications
Comprehensive instruction manual for VEVOR Ultrasonic Cleaners, detailing operation, maintenance, safety precautions, and technical specifications for both mechanical and digital models. Covers a wide range of applications across various industries.
Preview VEVOR Ultrasonic Cleaners User Manual - JPS Series Models
User manual for VEVOR Ultrasonic Cleaners, covering models JPS-10A, JPS-20A, JPS-30A, JPS-40A, JPS-60A, JPS-80A, JPS-100A, and SS5. Includes safety instructions, operation guides, technical specifications, and maintenance tips.
Preview VEVOR Ultrasonic Cleaners User Manual: Operation and Safety Guide
This user manual from VEVOR details the operation, safety, and maintenance of their ultrasonic cleaning machines. These devices utilize high-frequency sound waves to efficiently clean a wide range of items, from delicate jewelry and optical lenses to industrial parts and laboratory equipment.
Preview UKOKE Ultrasonic Cleaner 4820: Instruction Manual & User Guide
Comprehensive instruction manual for the UKOKE Ultrasonic Cleaner 4820. Learn about its applications, features, operation, cleaning methods, and important safety instructions for optimal use in homes and professional settings.
Preview Aocktobar Ultrasonic Cleaner ZX-895: Usage Guide & Cleaning Tips
Learn how to properly use and maintain your Aocktobar Ultrasonic Jewelry Cleaner (Model ZX-895) for optimal performance. This guide covers essential cleaning tips, warnings, and best practices for jewelry, glasses, and watches.