1. Introduction
This manual provides essential information for the safe and efficient use of your Relfar Laser Welding Head Power Supply. Please read this manual thoroughly before installation, operation, or maintenance. Keep this manual for future reference.
2. Safety Information
WARNING: HIGH VOLTAGE INSIDE. DO NOT REMOVE THIS COVER. QUALIFIED SERVICE PERSONNEL ONLY.
Improper use of this power supply can result in serious injury or death. Always observe the following safety precautions:
- Ensure the power supply is disconnected from the main power source before performing any installation, maintenance, or troubleshooting.
- Only qualified personnel should install, operate, or service this equipment.
- Do not expose the unit to moisture, rain, or excessive humidity.
- Ensure adequate ventilation around the power supply to prevent overheating.
- Verify all connections are secure and correctly wired according to the diagrams provided.
- Do not operate the unit if it is damaged or malfunctioning.
- Always use appropriate personal protective equipment (PPE) when working with laser equipment and power supplies.

3. Product Overview
The Relfar Laser Welding Head Power Supply series provides stable DC power for various laser welding and cleaning gun applications. These units are designed for reliability and performance in industrial settings.

3.1. Models and Variants
This product line includes several models, each with specific output characteristics:
- S-60-24: A compact power supply providing a single 24V DC output.
- S-150-24: A higher power variant, also providing a 24V DC output.
- HF60W-D-L: A dual-output power supply providing both +15V and -15V DC outputs.
- FWH20-S10/20 and FWH30-D10/20 are typically associated with the laser welding/cleaning heads that these power supplies are designed to operate.
4. Specifications
Key specifications for the Relfar Power Supply units are detailed below:
| Feature | S-60-24 / S-150-24 | HF60W-D-L |
|---|---|---|
| Material | Stainless Steel | |
| Type | Power Tool Parts | |
| Origin | Mainland China | |
| Input Voltage | 100-240VAC, 50/60Hz | 200-240VAC, 0.6A, 50/60Hz |
| Output Voltage / Current | +24V, 2.5A (S-60-24) | V1= +15V, 2.0A; V2= -15V, 2.0A |
| Package Dimensions (Approx.) | Length: 20cm, Width: 10cm, Height: 10cm | |
| Package Weight (Approx.) | 0.3 kg | |
5. Setup Instructions
Follow these steps for proper installation of your Relfar Power Supply:
- Unpacking and Inspection: Carefully remove the power supply from its packaging. Inspect for any visible damage. If damage is found, do not proceed with installation and contact support.
- Mounting: Securely mount the power supply in a well-ventilated area, away from heat sources and flammable materials. Ensure proper airflow for cooling.
- Wiring (S-60-24 / S-150-24):
- Connect the AC input (100-240VAC, 50/60Hz) to the terminals labeled 'L' (Live), 'N' (Neutral), and 'FG' (Frame Ground). Ensure proper grounding.
- Connect the DC output to your laser welding/cleaning head or other load using the terminals labeled '+V' and '-V' (or COM). Observe polarity.

Figure 5.1: S-60-24 Power Supply terminal block for input and output connections. - Wiring (HF60W-D-L):
- Connect the AC input (200-240VAC, 50/60Hz) to the terminals labeled 'L' (Live), 'N' (Neutral), and 'FG' (Frame Ground). Ensure proper grounding.
- Connect the DC outputs: V1 (+15V) and V2 (-15V) to your load, using the 'COM' (Common) terminals as reference.

Figure 5.2: HF60W-D-L Power Supply terminal block with dual output connections. - Final Checks: Double-check all wiring for correctness and security. Ensure no loose wires or short circuits.
6. Operating Instructions
Once the power supply is correctly installed and all connections are verified:
- Power On: Connect the power supply to the main AC power source. The unit should power on, and any associated indicators on your laser equipment should illuminate.
- Monitor Performance: Observe the operation of your laser welding/cleaning head. Ensure stable power delivery and correct functionality.
- Power Off: To shut down, disconnect the power supply from the main AC power source.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your power supply:
- Cleaning: Periodically clean the exterior of the unit with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Never use liquid cleaners directly on the unit.
- Inspection: Regularly inspect all cables and connections for signs of wear, damage, or loose contacts.
- Ventilation: Ensure the installation area maintains good airflow and that the power supply's vents are not obstructed.
WARNING: Do not attempt to open the power supply casing for internal cleaning or repairs. Refer to qualified service personnel.
8. Troubleshooting
If you encounter issues with your Relfar Power Supply, consider the following basic troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| No power / Unit not turning on | No AC input power Loose power cable Internal fuse blown | Check main power source and circuit breaker Ensure power cable is securely connected Contact qualified service personnel for fuse replacement |
| Incorrect output voltage | Incorrect wiring Overload Faulty unit | Verify output wiring polarity and connections Reduce load on the power supply Contact qualified service personnel |
| Overheating | Poor ventilation Excessive ambient temperature Overload | Ensure clear airflow around the unit Operate in a cooler environment Reduce load on the power supply |
If the problem persists after performing these steps, contact customer support.
9. User Tips
No specific user tips are available from reviews or Q&A for this product at this time. Always prioritize safety and follow the instructions in this manual.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the Demarklaser Official Store using the details below:
- Contact Person: Josepha
- Email: josepha@demarkchina.com
- Whatsapp: +86 18371977353
- Website: www.demarkchina.cn