Relfar FWH20-S10/20, FWH30-D10/20, S-60-24, S-150-24, HF60W-D-L

Rate this product
Contents

Relfar Laser Welding Head Power Supply User Manual

Models: FWH20-S10/20, FWH30-D10/20, S-60-24, S-150-24, HF60W-D-L

Brand: Relfar

1. Introduction

This manual provides essential information for the safe and efficient use of your Relfar Laser Welding Head Power Supply. Please read this manual thoroughly before installation, operation, or maintenance. Keep this manual for future reference.

2. Safety Information

WARNING: HIGH VOLTAGE INSIDE. DO NOT REMOVE THIS COVER. QUALIFIED SERVICE PERSONNEL ONLY.

Improper use of this power supply can result in serious injury or death. Always observe the following safety precautions:

  • Ensure the power supply is disconnected from the main power source before performing any installation, maintenance, or troubleshooting.
  • Only qualified personnel should install, operate, or service this equipment.
  • Do not expose the unit to moisture, rain, or excessive humidity.
  • Ensure adequate ventilation around the power supply to prevent overheating.
  • Verify all connections are secure and correctly wired according to the diagrams provided.
  • Do not operate the unit if it is damaged or malfunctioning.
  • Always use appropriate personal protective equipment (PPE) when working with laser equipment and power supplies.
Side view of S-60-24 Power Supply showing 'High Voltage Inside' warning label.
Figure 2.1: Safety warning label on the power supply.

3. Product Overview

The Relfar Laser Welding Head Power Supply series provides stable DC power for various laser welding and cleaning gun applications. These units are designed for reliability and performance in industrial settings.

Overview of Relfar Laser Welding Head Power Supplies, showing models S-60-24 and HF60W-D-L.
Figure 3.1: Relfar Laser Welding Head Power Supplies (S-60-24 and HF60W-D-L models shown).

3.1. Models and Variants

This product line includes several models, each with specific output characteristics:

  • S-60-24: A compact power supply providing a single 24V DC output.
  • S-150-24: A higher power variant, also providing a 24V DC output.
  • HF60W-D-L: A dual-output power supply providing both +15V and -15V DC outputs.
  • FWH20-S10/20 and FWH30-D10/20 are typically associated with the laser welding/cleaning heads that these power supplies are designed to operate.

4. Specifications

Key specifications for the Relfar Power Supply units are detailed below:

FeatureS-60-24 / S-150-24HF60W-D-L
MaterialStainless Steel
TypePower Tool Parts
OriginMainland China
Input Voltage100-240VAC, 50/60Hz200-240VAC, 0.6A, 50/60Hz
Output Voltage / Current+24V, 2.5A (S-60-24)V1= +15V, 2.0A; V2= -15V, 2.0A
Package Dimensions (Approx.)Length: 20cm, Width: 10cm, Height: 10cm
Package Weight (Approx.)0.3 kg

5. Setup Instructions

Follow these steps for proper installation of your Relfar Power Supply:

  1. Unpacking and Inspection: Carefully remove the power supply from its packaging. Inspect for any visible damage. If damage is found, do not proceed with installation and contact support.
  2. Mounting: Securely mount the power supply in a well-ventilated area, away from heat sources and flammable materials. Ensure proper airflow for cooling.
  3. Wiring (S-60-24 / S-150-24):
    • Connect the AC input (100-240VAC, 50/60Hz) to the terminals labeled 'L' (Live), 'N' (Neutral), and 'FG' (Frame Ground). Ensure proper grounding.
    • Connect the DC output to your laser welding/cleaning head or other load using the terminals labeled '+V' and '-V' (or COM). Observe polarity.
    Rear view of S-60-24 Power Supply with terminal block and label.
    Figure 5.1: S-60-24 Power Supply terminal block for input and output connections.
  4. Wiring (HF60W-D-L):
    • Connect the AC input (200-240VAC, 50/60Hz) to the terminals labeled 'L' (Live), 'N' (Neutral), and 'FG' (Frame Ground). Ensure proper grounding.
    • Connect the DC outputs: V1 (+15V) and V2 (-15V) to your load, using the 'COM' (Common) terminals as reference.
    Top view of HF60W-D-L Power Supply with input/output specifications and terminal labels.
    Figure 5.2: HF60W-D-L Power Supply terminal block with dual output connections.
  5. Final Checks: Double-check all wiring for correctness and security. Ensure no loose wires or short circuits.

6. Operating Instructions

Once the power supply is correctly installed and all connections are verified:

  1. Power On: Connect the power supply to the main AC power source. The unit should power on, and any associated indicators on your laser equipment should illuminate.
  2. Monitor Performance: Observe the operation of your laser welding/cleaning head. Ensure stable power delivery and correct functionality.
  3. Power Off: To shut down, disconnect the power supply from the main AC power source.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your power supply:

  • Cleaning: Periodically clean the exterior of the unit with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Never use liquid cleaners directly on the unit.
  • Inspection: Regularly inspect all cables and connections for signs of wear, damage, or loose contacts.
  • Ventilation: Ensure the installation area maintains good airflow and that the power supply's vents are not obstructed.

WARNING: Do not attempt to open the power supply casing for internal cleaning or repairs. Refer to qualified service personnel.

8. Troubleshooting

If you encounter issues with your Relfar Power Supply, consider the following basic troubleshooting steps:

ProblemPossible CauseSolution
No power / Unit not turning onNo AC input power
Loose power cable
Internal fuse blown
Check main power source and circuit breaker
Ensure power cable is securely connected
Contact qualified service personnel for fuse replacement
Incorrect output voltageIncorrect wiring
Overload
Faulty unit
Verify output wiring polarity and connections
Reduce load on the power supply
Contact qualified service personnel
OverheatingPoor ventilation
Excessive ambient temperature
Overload
Ensure clear airflow around the unit
Operate in a cooler environment
Reduce load on the power supply

If the problem persists after performing these steps, contact customer support.

9. User Tips

No specific user tips are available from reviews or Q&A for this product at this time. Always prioritize safety and follow the instructions in this manual.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the Demarklaser Official Store using the details below:

  • Contact Person: Josepha
  • Email: josepha@demarkchina.com
  • Whatsapp: +86 18371977353
  • Website: www.demarkchina.cn
Contact information for Demarklaser Official Store, including name, email, Whatsapp, and website.
Figure 10.1: Demarklaser Official Store contact details.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?