1. Introduction
This manual provides detailed instructions for the safe and effective use of the Relfar FWH30-D20C-V4-T Intelligent Double Pendulum Handheld Laser Welding Head. This advanced 4-in-1 weld gun features a 3000W laser and dual wire feeding capabilities, designed for precision welding applications. Please read this manual thoroughly before operating the equipment to ensure proper setup, operation, and maintenance.
2. Safety Precautions
WARNING: Laser radiation can cause severe injury. Always wear appropriate personal protective equipment (PPE), including laser safety glasses, and ensure all safety interlocks are functional before operation.
- Always operate the laser welding head in a well-ventilated area.
- Ensure all electrical connections are secure and properly grounded.
- Never look directly into the laser beam or at the welding arc without proper eye protection.
- Keep flammable materials away from the welding area.
- The system includes an alarm status area that displays critical alerts such as protective gas low pressure, cooling water flow alarms, laser alarms, and temperature alarms. Monitor these alarms closely during operation.
- Do not attempt to disassemble or repair the unit unless specifically instructed in this manual by qualified personnel.
- Ensure the safety lock is engaged when the welding head is not in use.
3. Package Contents
Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your supplier.
Figure 3.1: Overview of the complete Relfar FWH30-D20C-V4-T kit.
| S/N | Name | Quantity |
|---|---|---|
| 1 | Intelligent handheld welding head | 1 PCS |
| 2 | 24V power pack | 1 PCS |
| 3 | 15V power pack | 1 PCS |
| 4 | Ground clamp component | 1 PCS |
| 5 | 7-inch display screen | 1 PCS |
| 6 | Touchscreen 6-core connection cable - 1.5m - Black | 1 PCS |
| 7 | Handheld Laser Welding System V4 | 1 PCS |
4. Specifications
Key technical specifications for the Relfar FWH30-D20C-V4-T laser welding head:
Figure 4.1: Technical Specifications.
| Parameter | Value |
|---|---|
| Name | Intelligent double pendulum |
| Model | FWH30-D20C-V4-T |
| Fiber interface | QBH |
| Wavelength scope | 1070±20nm |
| Rated power | ≤3000W |
| Collimation focal length | 40mm |
| Focus focal length | 200mm |
| Swing type | Various patterns (e.g., line, circle, figure-eight) |
| Regulating scope of focal point | -10mm~+10mm |
| Regulating scope of light spot | 0~8mm |
| Auxiliary pressure | ≤1Mpa |
| Weight | 1.0Kg |
| Material | Stainless steel |
| Type | Hand Tool Parts |
4.1 Handheld Laser Control System V4 Dimensions
Figure 4.2: Overall dimensions of the Handheld Laser Control System V4 main board (196.8 * 111.8 * 52 mm).
5. Setup
5.1 Pipe Connection
Proper connection of cooling water and auxiliary protective gas is essential for operation.
Figure 5.1: Cooling water circuit and auxiliary protective gas connection points.
- Cooling Water: Connect the 6mm water pipe to the designated inlet. The main function is to dissipate excess heat.
- Auxiliary Protective Gas: Connect the 6mm air tube to the designated inlet. Regularly used gases include argon, nitrogen, and compressed air. If using compressed air, ensure it is oil-water filtered.
5.2 System Wiring
Follow the schematic diagram for wiring the entire system. Refer to the detailed interface definitions in the relevant chapters of the full manual (if available).
Figure 5.2: System wiring diagram for the Handheld Laser Control System V4. Note: Do not connect the reserved pin in the mainboard.
5.2.1 CN2 Laser Interface
The laser interface is an 8PIN green terminal. Table 5.1 defines the laser interface pins.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | PWM+ | Modulated signal + | Duty cycle adjustable from 1% to 99%, 24V level |
| 2 | PWM- | Modulated signal - | Duty cycle adjustable from 1% to 99%, 24V level |
| 3 | DA | Simulated voltage output | 0-10V analog voltage, used for adjusting the peak power of the laser |
| 4 | GND | Power reference ground | Generally, it connects to the laser control interface DA. |
| 5 | OVCC | +24V power output | Power supply, capable of delivering a maximum output of 500mA |
| 6 | Enable | Laser enable signal | 24V voltage level, with high level as the active state |
| 7 | Alarm_in | Laser failure alarm input | — |
| 8 | GATE | Red light indication signal | 24V voltage level, with low level as the active state |
| 9 | GND | Signal reference ground | — |
| 10 | GND | Signal reference ground | — |
Table 5.1: CN2 Laser Interface Pin Definitions.
5.2.2 CN6 External Start and Interlock Interface
The CN6 interface is a 4PIN green terminal. Table 5.2 defines the CN6 interface pins.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | GND | Reference ground | Generally connecting to the start button switch on the welding head. |
| 2 | Start | External start switch input | Generally connecting to the start button switch on the welding head. |
| 3 | Injector | Safety clamp signal input | The pin must be connected to the safety clamp and the safety clamp shall be clamped onto the metal material before welding. |
| 4 | Interlock | Safety lock signal input | The pin must be connected to the nozzle of the handheld head. The nozzle touches the metal material at the moment of welding. |
Table 5.2: CN6 External Start and Interlock Interface Pin Definitions.
5.3 APP Setup and Connection
The RDWelder mobile APP supports single pendulum welding, double pendulum welding, and cleaning functions. After the APP is connected to the board card, it automatically adapts to the current processing mode of the control card.
5.3.1 APP Download
To download the RDWelder APP:
- Android: Scan the QR code below or visit this link.
- Apple (iOS): Search for "RDWelder" in the App Store.
Figure 5.3: QR Code for Android APP Download.
5.3.2 APP WiFi Connection
After the WiFi hotspot configuration is complete, the WiFi configuration mode will be turned off, the WiFi icon will light up, and the mobile phone APP can connect to the WiFi on the board card.
Figure 5.4: APP WiFi Settings Interface.
- Click the icon on your mobile phone to launch the APP.
- The device connection status in the upper left corner of the motor enters the < Device Management > page.
- Select the direct connection of the device, enter the phone Settings page to set up the WiFi connection, and connect to the WiFi hotspot of the control card.
- After the connection is completed, you can enter the APP to check that the mobile APP has been connected to the device.
6. Operation
The Relfar FWH30-D20C-V4-T offers various modes and settings for precise laser welding and cleaning.
Video 6.1: Demonstration of the laser welding head in operation, showing the welding process and the resulting weld seam.
6.1 HMI Operation Introduction
The handheld laser welding control system operates via a 7-inch TFT touch screen, providing a user-friendly interface for setting parameters, monitoring status, and managing alarms.
Figure 6.1: Main interface of the HMI (Human-Machine Interface).
6.1.1 Parameter Setting
The HMI allows access to various settings:
- Home page: Used to set parameters related to laser, swing, and process library.
- System parameter: General system configurations.
- Wire feeding parameter: Settings for the dual wire feeder.
- Diagnosis page: For system diagnostics and troubleshooting.
Specific parameters include:
- Welding mode: Select between continuous and pulse welding modes.
- Power: Set the peak power of the laser.
- PWM frequency: Adjust the frequency of the laser's PWM modulating signal.
- Duty cycle: Set the duty cycle of the PWM signal (range 1% to 100%).
- Swing frequency: Set the galvanometer motor swing frequency.
- Swing on/off: Toggle galvanometer motor swing.
- Safety lock: Start or close the safety lock. The laser will stop emitting if the welding head does not touch the material when the safety lock is active.
- Automatic wire feeding on/off: Control automatic wire feeding.
- Emit laser: Start or stop laser emission.
- Alarm status area: Displays real-time alarms for protective gas low pressure, cooling water flow, laser, and temperature.
6.2 Processing Module Switching (Welding/Cleaning)
To switch between welding mode and 100mm cleaning mode:
- On the HMI panel, navigate to
[System Parameter] -> [Authorization] -> [Processing Type]. - Input the password
666666when prompted. - After entering the correct password, you can select the desired processing type.
Figure 6.2: Selecting processing type (Welding or Cleaning).
6.3 System Switching for Welding Seam Cleaning
The system allows for easy switching to welding seam cleaning mode. The maximum width for welding seam cleaning is 12 mm.
Figure 6.3: System switching interface for adjusting welding seam cleaning parameters.
6.4 APP Functions
The RDWelder APP provides comprehensive control and monitoring capabilities:
Figure 6.4: RDWelder APP interface for welding and cleaning modes, diagnosis, and settings.
- Welding mode: Supports management of process parameters, processing status, blowing adjustment, and wire feeding control.
- Cleaning mode: Similar to welding mode, with specific parameters for cleaning operations.
- Diagnosis: Manages the status of the equipment, supports querying alarm records, and enables central correction.
- Settings: Access to general settings and authorization management.
- My: Personal user page for managing personal information.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your laser welding head.
7.1 Cleaning of Optics Lens
The optics lens must be cleaned in a dust-free environment. Other modules should not be disassembled unless the protective glass drawer can be disassembled and assembled. If checking collimating lens, focus lens, and galvanometer lens, the product must be in a clean environment for disassembly.
Tools required: Dust-free gloves, dust-free cotton swab, isopropyl alcohol, canned dry and pure compressed air.
Procedure:
- Spray isopropyl alcohol onto a dust-free cotton swab.
- Align the lens to your eyes.
- Gently pinch the side edge of the lens with your left thumb and index finger.
- Hold the dust-free cotton swab with your right hand and gently wipe the front and back of the lens in a single direction (from bottom to top or from left to right).
- Avoid wiping back and forth to prevent secondary contamination.
- Blow the surface of the lens with filtered dry and pure compressed air to confirm the surface is free from foreign matter.
Figure 7.1: Correct (green check) and Incorrect (red cross) lens cleaning methods.
7.2 Disassembly and Assembly of Focus Lens
This procedure must be completed in a clean, dust-free environment. Ensure you wear dust-free gloves or fingerstalls.
Tools required: 2mm hexagon key wrench, dust-free cotton swab, ethyl alcohol, masking tape.
Procedure:
- Loosen the M2.5 hex socket head cap screw by hand with a 2mm hex wrench.
- Take out the focus drawer module by direct drawing/pulling in the horizontal direction.
- Seal the port with textured paper to prevent dust from entering the cavity, resulting in pollution.
- Rotate the gland for 90° after pressing it downward gently and take out the gland by two bosses aligning to left/right opening to replace the focus lens.
Note: Orientation of installed lens in the concave and convex direction is important.
Figure 7.2: Focus lens disassembly diagram.
7.3 Welding Nozzle Replacement
To replace the welding nozzle, simply remove the old nozzle and replace it with a special nozzle for welding seam cleaning.
Figure 7.3: Schematic diagram for welding nozzle replacement.
8. Troubleshooting
This section provides guidance on common issues and their resolutions.
8.1 Temperature Parameter Setting of Protective Lens
To prevent overheating and potential damage, monitor and set the temperature alarm for the protective lens.
Figure 8.1: HMI interface for setting protective lens temperature parameters.
Procedure:
- Navigate to
[Home Page] -> [System Parameter] -> [Equipment Parameter] -> [Input Password: 666666] -> next page -> lens temperature alarm limit value. - It is suggested to set the set value of lens temperature to 50.
- After the lens temperature exceeds the set value, the alarm caution will arise on the home page and the display light on the side of the handheld plumb joint will turn to red.
8.2 General Alarms
The system's alarm status area provides real-time feedback on operational issues. If an alarm signal is triggered, the alarm icon will be blue, and the alarm message will be displayed in red and alternately.
- Protective Gas Low Pressure: Check gas supply and connections.
- Cooling Water Flow Alarm: Ensure the cooling system is functioning correctly and water flow is adequate.
- Laser Alarm: Indicates an issue with the laser source. Consult the full manual or contact support.
- Temperature Alarm: Indicates overheating. Check cooling, ambient temperature, and lens temperature settings.
9. User Tips
- Regular Cleaning: Adhere strictly to the lens cleaning procedures to maintain optimal laser performance and prevent damage. Dust and debris can significantly impact weld quality and laser lifespan.
- Gas Purity: Always use high-purity protective gases (argon, nitrogen) or ensure compressed air is thoroughly filtered for oil and water to prevent contamination of the weld and optics.
- Parameter Optimization: Experiment with different welding modes (continuous/pulse) and parameters (power, frequency, duty cycle, swing type) on scrap material to find the optimal settings for your specific material and application.
- APP Utilization: Leverage the RDWelder APP for remote monitoring and parameter adjustment, which can enhance efficiency and convenience during operation.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Ensure you have your product model number (FWH30-D20C-V4-T) and purchase details available when contacting support.
The product may be eligible for free returns within 90 days, as per seller policy. Please refer to your purchase agreement for specific terms.