1. Introduction
The Relfar FWH30-D10C V4 is an intelligent double pendulum handheld laser welding head designed for versatile industrial applications. This 4-in-1 device supports welding, cleaning, cutting, and weld seam cleaning functions, offering high precision and efficiency. This manual provides detailed instructions for the safe and effective use, setup, maintenance, and troubleshooting of your laser welding head.

Video 1.1: Product function demonstration showing welding, cutting, weld seam cleaning, and cleaning operations.
2. Specifications
2.1 Product Parameters
| Name | Parameter |
|---|---|
| Model | FWH30-D10C-V4-T |
| Fiber interface | QBH |
| Wavelength scope | 1,070±20nm |
| Rated power | ≤ 3,000W |
| Collimation focal length | 40mm |
| Focus focal length | 150mm |
| Swing type | —、〇、∞、✕、◎、△、⊕ |
| Regulating scope of focal point | -10mm~+10mm |
| Regulating scope of light spot | 0~5mm |
| Auxiliary pressure | ≤1Mpa |
| Weight | 1.0Kg |
2.2 Product Properties
- Material: Stainless steel
- Type: Hand Tool Parts
- Origin: Mainland China
2.3 Package Contents

The package includes:
- Intelligent handheld welding head (FWH30-D10C-V4-T) - 1 PCS
- Ground clamp (10m) - 1 PCS
- 24V switch power supply (S-60-24) - 1 PCS
- ±15V switching power supply (HF60W-D-L) - 1 PCS
- Display card buckle - 4 PCS
- 7-inch display screen - 1 PCS
- Display screen connection cable (1.5m, black with 6pin male ends) - 1 PCS
- Handheld laser Welding system V4 (RDWdelderV4-SWPro) - 1 PCS
- Various welding/cutting/cleaning nozzles and accessories (Internal thread 0.8, 1.0, 1.2, 1.6; Cutting torch; Guide tube; Protective lenses D25*2; Guide wire tip 0.8, 1.0, 1.2, 1.6; Clean nozzle 1.6; Clean the focus component F1000; Clean the gas ring assembly H08-122B; Sprueweld cleaning H03-196B (F150)) - 1 set
3. Setup
3.1 System Wiring
The following figure illustrates the schematic diagram for wiring the entire system. Refer to the schematic diagram for system wiring. Refer to relevant chapters for detailed interface definition.

Note:
- Do not connect the reserved pin in the mainboard.
3.2 Pipe Connection
Cooling water circuit and auxiliary protective gas connection are essential for proper operation.

Connection of cooling water and shielding gas and usage requirements:
- Cooling Water: The 6mm air tube is connected. The main function is that the excess heat is taken away by cooling through the internal structural member water route when the heat is produced by the light path in the cavity to ensure the welding performance. The series connection of cooling water pipeline is required, with one-in and one-out water circulation connected.
- Protective Gas: The 6mm air tube is connected for butt welding gas protection, with input pressure ≤1Mpa. Regularly used gases are: argon, nitrogen and compressed air (oil-water filtration required).
3.3 Optical Fiber Input Installation
The QBH is a horizontal arrangement to take out the dustproof seal cover.

- Align the red dot on the fiber optic head with the QBH red dot, and slowly insert the fiber optic head into the QBH.
- The QBH is screwed to the locking state: Rotate it to the limiting position clockwise (hearing the "click"), lift up the rotating mantle, and clockwise rotate the mantle until the head of optical fiber is compressed.

3.4 HMI Touch Screen Interface
The HMI interface is a 6PIN green terminal and power supply to and communication with HMI by the mainboard are performed via the port. The definition of HMI interface is shown in the table below.
| Pin | Signal | Definition | Instruction |
|---|---|---|---|
| 1 | OVCC | +24V power output, 500mA | Panel power supply |
| 2 | TXD_HMI | Connecting to the HMI sending end | Serial port communication TXD signal |
| 3 | RXD_HMI | Connecting to the HMI receiving end | Serial port communication RXD signal |
| 4 | TXD | Reserved communication interface | RS232 reserved communication interface |
| 5 | RXD | Reserved communication interface | RS232 reserved communication interface |
| 6 | GND | Power reference ground | — |
3.5 APP Connection
The RDWelder mobile APP is an application suitable for remote control of handheld welding products, supporting various types of product applications such as single pendulum welding, double pendulum welding, single pendulum cleaning, and double pendulum cleaning. Users can connect the board card through this APP to achieve the purpose of wireless connection control. It can effectively solve the problem of the processing station being far from the equipment and constantly traveling back and forth. It supports remote viewing of equipment status and parameter adjustment, facilitating equipment management and maintenance. The APP also has rich technical center resources. It is provided for customers to install and maintain equipment, review process data, assist in troubleshooting, and refer to application cases.
3.5.1 AP Mode Connection
In AP mode, the APP is directly connected to the control card. The control card emits a WiFi hotspot signal. Customers can use mobile devices such as mobile phones to connect to the WiFi hotspot signal emitted by the control card. After the connection is completed, the board card can be controlled using the APP. Both the touchscreen and the APP use WiFi ICONS for status display.

Board card Settings:
- Click the upper right corner of the touch screen to enter the WiFi configuration page and configure the WiFi hotspot.
- Set the connection mode to AP and set the name and password of the WiFi hotspot. If the WiFi is turned on, you need to first click the <Turned On> button to turn off the WiFi. When the WiFi icon goes off, you will enter the configurable WiFi setting state.
- After the configuration is completed, click the <Turn on WiFi> button, and the system will turn on WiFi again.
3.5.2 STA Mode Connection
In STA mode, the APP and the control card are connected to the cloud via the Internet. After setting the control card to STA mode, it is necessary to connect to WiFi to access the network. Access the server through traffic data to obtain the device status and perform operation control. Both the touchscreen and the APP use Internet of Things cloud ICONS for status display.

APP Settings:
- Click the icon on your mobile phone to launch the APP.
- The device connection status in the upper left corner of the motor enters the <Device Management> page.
- Select the direct connection of the device, enter the phone Settings page to set up the WiFi connection, and connect to the WiFi hotspot of the control card.
- After the connection is completed, you can enter the APP to check that the mobile APP has been connected to the device.
3.5.3 APP Download Method
Android: Scan the QR code below or visit the provided URL.

URL: https://mantisolo.com/versionQrCode.html?qrform=6e7a13d4f48d72e6e025b0b12af8e3bc13&company_code=003&platform=APP
Apple: Search for “RDWelder” in the App Store.
4. Operating Instructions
4.1 HMI Operation Introduction
The handheld laser welding control system operating panel ("HMI" for short) adopts a 7-inch configuration TFT touch screen with beautiful interface and convenient operation. It can set laser related parameters. On the main interface, the input and output IO status, alarm information and motion state can be displayed in real time. Refer to the following figure for the HMI main interface.

Key Functions:
- Swing off: to set galvanometer motor swing on or off
- Safety lock: to start or close the safety lock. When the lock is started, during the welding, the laser will stop when the welding head does not touch the welding material.
- Automatic wire feeding off: to control whether to start automatic wire feeding during welding. It will start automatic wire feeding only when laser emits light.
- Emit laser: to start emitting laser or stopping emitting laser
- Alarm status area: when alarm signal enables, protective gas low pressure, cool water flow alarm, laser alarm and temperature alarm status will be displayed in real time. When the safety lock is started, its status will be displayed in real time. When the alarm signal is not triggered, the alarm icon is blue; when it is triggered, the alarm icon is blue and red alternately.
- Homepage/ Wire feeding parameter/ Diagnosis/ System parameter: to display the type of parameter on the current page. Click an icon to enter the switch of the corresponding parameter page. For instance, if the icon on the homepage turns on, the parameter in the current display area is the parameter of the homepage. When it needs to switch to wire feeding parameter, just click the position of wire feeding, and the icon of this parameter will turn on.
- Blowing manually/ Wire feeder: for manual blowing test and the wire feeding and wire withdrawing tests of wire feeder. For example, long press manual blowing key, and it will blow all the time; loosen this key, and it will stop blowing. For manual wire feeding and wire withdrawing, long press the corresponding small triangle area.
4.2 Parameter Setting
Parameter setting includes: Home page, System parameter, Wire feeding parameter and Diagnosis page.
- Home page: used to set parameters related to laser, swing and process library when welding.
- Process library: click the white box area in process library. The set process library parameter can be selected.
- Welding mode: to set welding mode, continuous and pulse modes.
- Power: to set the peak power of laser when welding
- PWM frequency: used to set the frequency of laser PWM modulating signal
- Duty cycle: used to set duty cycle of PWM signal with the range from 1% to 100%
- Swing frequency: used to set motor swing frequency
- Swing length: used to set motor swing length
- Maximum frequency: set the maximum frequency of laser PWM signal. When PWM frequency set by welding parameter exceeds the maximum frequency, the frequency will be limited to the maximum value.
- Maximum swing length: set the maximum length during swing. When the length set by welding parameter exceeds the maximum length, the length will be limited to the maximum length.
- Wire feeding step: used to set the step during motor wire feeding.
- Direction of motor wire feeding: used to set the direction polarity of motor wire feeding.
- Galvanometer correction coefficient: when there is a nuance in the set length and the actual length, it can be modified by this parameter. When there is no need for correction, it is usually set as 1.
4.3 Welding Mode
The welding mode allows for precise control over laser power, frequency, and swing parameters to achieve optimal weld quality. The video demonstrates welding operations and the resulting clean weld seam.
4.4 Cutting Mode
The cutting mode enables efficient material separation. Ensure the correct cutting nozzle is installed and parameters are set according to the material and desired cut. The video shows the cutting process and the resulting clean cut.
4.5 Weld Seam Cleaning Mode
This mode is used to clean weld seams, removing discoloration and impurities. The video illustrates the weld seam cleaning process and its effectiveness.
4.6 Cleaning Mode
The cleaning mode is designed for surface preparation and rust removal. Adjust parameters for laser power, scanning speed, and scanning length/width based on the material and level of contamination. The video demonstrates the cleaning process on a rusted surface.
5. Maintenance
Regular maintenance is crucial for the longevity and optimal performance of your Relfar laser welding head. Always ensure the device is powered off and disconnected before performing any maintenance.
5.1 Structure of Optics Lens
The assembly is completed in a dust-free plant at the time of replacement of parts. In principle, other modules are forbidden to be dismounted except that the protective glass drawer can be disassembled and assembled. If it is necessary to check the collimating lens, focus lens and galvanometer lens, the product shall be put into a clean environment for disassembly.

5.2 Cleaning of Optics Lens
- When the optics lens are cleaned, the operation method and attention points are as follows:
- Tools: Dust-free gloves or dust-free fingerstall, dust-free wiping cotton swab, isopropyl alcohol, and canned dry and pure compressed air.
- Spray the isopropyl alcohol onto the dust-free cotton swab, align the lens to eyes, gently pinch the side edge of the lens with left thumb and index finger and hold the dust-free cotton swab with right hand to gently wipe the front and back of the lens in a single direction from bottom to top or from left to right (avoid wiping back and forth to avert the secondary contamination of lens), blow the surface of the lens with filling dry and pure compressed air and confirm the surface of lens is free from foreign matters after cleaning.

5.3 Disassembly and Assembly of Optics Lens
5.3.1 Disassembly and assembly of collimation lens
Tools: 2mm inner-hexagon wrench, dust-free cotton swab, alcohol
- The disassembly and assembly shall be completed in a clean place. When the lens are dismounted, the dust-free gloves or dust-free fingerstall.
- Disassembly and assembly steps:
- Clean up all the dust on the surface of the laser head firstly.
- Loosen the M2.5 hex socket head cap screw in the figure by hand with a 2mm hex wrench.
- Remove the collimation handle horizontally, and pull out the collimation drawer module.
- Seal the port with textured paper to prevent the dust from entering the cavity, resulting in pollution.
- Rotate the gland for 90° after pressing it downward gently and take out the gland by two bosses aligning to left/right opening to replace the collimation lens.

5.3.2 Disassembly and assembly of focus lens
Follow similar steps as for the collimation lens, ensuring a clean environment and careful handling.

5.3.3 Disassembly and assembly of protective glass
Follow similar steps as for the collimation lens, ensuring a clean environment and careful handling.

5.4 Module Dismantling and Replacement

Wire Feed Holder Module: Loosen the 2-M3 screw to take out the module (Figure 1).
Brass Nozzle Connecting Base: Loosen the 3-M2.5 screw to take out the module (Figure 2).
Jacket Installation: Installation pursuant to the sequence-1, 2 and 3.
Installation of Focus Drawer: Loosen the 4-M2.5 screw to directly draw out the focus module. Notice the small dot in the middle is in the upper part when the focus module is replaced and cleaned. The welding focus module replaced shall be subject to dustproof protection for use and replacement.

5.5 Processing Module Switching
To switch between processing modes (e.g., welding to cleaning), follow these steps:
- For welding mode switching to 100mm cleaning mode, input password-666666 will be reminded by clicking [Processing Type] on the panel pursuant to [System Parameter]->[Authorization]->[Processing Type]. After the password is put correctly, enter the system type selection interface, as shown in the figure.

5.5.1 Hint of module replacement
After the user chooses the processing type, the system shall use the text and picture for prompting for the gun head component to be replaced. The system will remind power-on anew by clicking [Confirm] after the user confirms the corresponding hardware components and replacement conditions. The equipment is powered down by the use interface to replace the corresponding component.
5.5.2 Switch completion
After the replacement of hardware component by the user is over, the equipment can be powered on anew. Whether you confirm the replacement of the hardware component will be reminded again at the moment. The user shall click [Confirm] after confirming the replacement of component is over and the system processing mode switch will be over.

5.6 Welding Seam Cleaning and Replacement
Remove the welding nozzle and replace the special nozzle for welding seam cleaning.

5.6.1 System switching
The system is easy to switch, and the maximum width of welding seam cleaning is 12 mm.

6. Troubleshooting
The system is equipped with various monitoring and protection devices to ensure safe operation. In case of an alarm, refer to the HMI display for specific error messages.
6.1 Monitoring Protection Device
The HMI displays real-time alarm status. When an alarm signal is not triggered, the icon is blue; when triggered, it alternates between blue and red.

Common alarms and their causes:
- Lens temperature alarm: Indicates the temperature of the protective lens exceeds the set limit. The alarm signal will be generated.
- Laser alarm: Indicates a laser emission issue. The alarm signal will be generated.
- Water-cooling machine alarm: Indicates a problem with the water cooling system. The alarm signal will be generated.
- Low pressure alarm: Indicates low protective gas pressure. The alarm signal will be generated.
If an alarm occurs, identify the specific issue from the HMI, check relevant connections (e.g., water pipes, gas lines), ensure proper lens temperature, and verify laser functionality. If the problem persists, contact technical support.
7. User Tips
- Always wear appropriate personal protective equipment (PPE), including laser safety glasses, during operation.
- Ensure the work area is well-ventilated to dissipate fumes and gases produced during welding, cutting, or cleaning.
- Regularly check and clean the optical lenses to maintain optimal performance and prevent damage.
- Before starting any operation, verify that all connections (power, water, gas, fiber optic) are secure and correctly installed.
- Familiarize yourself with the HMI and APP interfaces to quickly adjust parameters and monitor system status.
- For precise control, utilize the APP's remote management features to adjust parameters and monitor device status from a distance.
8. Support
For technical assistance, inquiries, or further information, please contact Relfar Intelligent Technology Co., Ltd. using the details below:

- Web: www.relfar.com
- Tel: 0755-23143635
- Address: 2F, Building 7, Jiuyang Industrial Park, 57 Hexiu West Road, Baoan District, Shenzhen, Guangdong Province
- Email: josepha@demarkchina.com
- Whatsapp: +86 18371977353
- Website: www.demarkchina.cn