1. Overview
The EPEVER Tracer-AN series MPPT Solar Charge Controller, including the Tracer4210AN G3 model, is designed for solar power systems. It features an advanced Maximum Power Point Tracking (MPPT) control algorithm to efficiently harvest energy from solar modules. This controller is suitable for various applications such as RVs, residential systems, and outdoor monitoring.
Key features include:
- Advanced MPPT technology with efficiency no less than 99.5%.
- Ultra-fast tracking speed and guaranteed tracking efficiency.
- Minimizes maximum power point loss rate and loss time.
- Wide MPP operating voltage range.
- High-quality components for perfecting system performance, with a maximum conversion efficiency of 98%.
- Accurate recognition and tracking of multiple-peaks maximum power point.
- Charging power and current limitation function.
- Compatible with lead-acid and lithium-ion batteries.
- Battery temperature compensation function.
- Real-time energy statistics function.
- Overheating power reduction function.
- Multiple load work modes.
- Professional protection chip for the communication port, providing 5VDC power supply, over-current, and short-circuit protection.
- RS-485 communication bus interface and Modbus communication protocol for various communication requirements.
- Monitoring and parameter setting via mobile phone APP or PC software.
- Full-load operation without capacity drop within the working environment temperature range.
- Extensive electronic protection.



The controller features an LCD display, SELECT and ENTER buttons for navigation, and various terminals for solar panel, battery, load, temperature sensor, and a COM port (RJ45).
For a visual overview of the product, please watch the following video:
2. Important Safety Instructions
Please read and save this manual for future reference. This manual contains critical safety, installation, and operation information for the Tracer AN series controller.
General Safety Information
- Read all instructions and warnings carefully before installation.
- The controller contains no user-serviceable components. DO NOT disassemble or attempt to repair the controller.
- Mount the controller indoors, protected from elements and water.
- Install the controller in a well-ventilated area. The heat sink can become very hot during operation.
- Install appropriate external fuses/breakers.
- Switch off all PV array connections and battery fuses/breakers before installation or adjustment.
- Ensure power connections remain tight to prevent excessive heating from loose connections.
Specific Warnings and Cautions
- WARNING: Explosive Risk! Equalizing flooded batteries produces explosive gases. Ensure good ventilation for the battery box. Never install the controller in a sealed enclosure with flooded batteries. Battery fumes can corrode and destroy controller circuits.
- CAUTION: Equipment Damage! Over-charging or excessive gassing can damage battery plates. Review battery requirements carefully. Equalization may increase battery voltage to levels that damage sensitive DC loads. Verify all load allowable input voltages are 11% greater than the equalizing charging set point voltage.
- WARNING: Risk of Electric Shock! When wiring solar modules, the PV array can produce open circuit voltages exceeding 100V in sunlight.
- CAUTION: The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
- CAUTION: When wiring, do not close the circuit breaker or fuse. Ensure positive and negative poles are connected correctly.
- CAUTION: A fuse (1.25 to 2 times the rated current of the controller) must be installed on the battery side, not more than 150mm from the battery.
- CAUTION: For areas with frequent lightning strikes, an external surge arrester must be installed.
- CAUTION: If an inverter is connected, connect it directly to the battery, not to the load side of the controller.
- CAUTION: For common-negative systems, if common-positive equipment is used and the positive electrode is grounded, the controller may be damaged.
- WARNING: If the PV array's open-circuit voltage exceeds the "maximum PV open-circuit voltage" rating (e.g., 50V for Tracer**06AN or 96V for Tracer**10AN at lowest environmental temperature), the controller may be damaged.
- WARNING: If the PV array is reverse connected with 1.5 times rated controller power (watts), the controller will be damaged.
- WARNING: The required accuracy of the Protection Circuit Module (PCM) for lithium batteries must be at least 0.2V. Deviations higher than 0.2V may lead to system malfunction, for which the manufacturer assumes no liability.
- WARNING: Before any operations, ensure all power is turned off before performing any maintenance or inspection operations.
3. Installation Instructions
3.1 General Installation Notes
- Always wear eye protection when handling batteries, especially flooded lead-acid types. Have fresh water available for washing any contact with battery acid.
- Keep batteries away from metal objects to prevent short circuits.
- Ensure good ventilation where batteries are charging to dissipate explosive gases.
- Avoid loose power connections and corroded wires, which can cause overheating and fire. Secure cables with clamps.
- Lead-acid and lithium batteries are recommended. Consult battery manufacturer for other types.
- Battery connection can be to a single battery or a bank of batteries.
- Multiple controllers of the same model can be installed in parallel on the same battery bank for higher charging current. Each controller needs its own solar module(s).
- Select system cables according to 5A/mm² or less current density, in accordance with Article 690 of the National Electrical Code, NFPA 70.
3.2 PV Array Requirements
The controller is compatible with various PV modules. The number of PV modules in series depends on the open circuit voltage (Voc) and maximum power point voltage (VMpp) of the MPPT controller. The following table provides reference values for the Tracer1210/2210/3210/4210AN models:
| System voltage | 36 cell Voc<23V | 48 cell Voc<31V | 54 cell Voc<34V | 60 cell Voc<38V | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 | 2 | 1 | 2 | 1 |
| 24V | 4 | 3 | 2 | 2 | 2 | 2 | 2 | 2 |
| System voltage | 72 cell Voc<46V | 96 cell Voc<62V | Thin-Film Module Voc>80V | ||
|---|---|---|---|---|---|
| Max. | Best | Max. | Best | ||
| 12V | 2 | 1 | 1 | 1 | 1 |
| 24V | 2 | 1 | 1 | 1 | 1 |
Note: These values are calculated under standard test conditions (STC: Irradiance 1000W/m², Module Temperature 25℃, Air Mass 1.5).
3.3 Wire Size
Wiring and installation must comply with all national and local electrical code requirements. The following tables provide recommended wire sizes:
PV Wire Size
| Model | Max. PV input current | Max. PV wire size* |
|---|---|---|
| Tracer1206AN/Tracer1210AN | 10A | 4mm²/12AWG |
| Tracer2206AN/Tracer2210AN | 20A | 6mm²/10AWG |
| Tracer3210AN | 30A | 10mm²/8AWG |
| Tracer4210AN | 40A | 16mm²/6AWG |
*These are the maximum wire sizes that will fit the controller terminals. Isc = short circuit current (amps), Voc = open circuit voltage.
Battery and Load Wire Size
| Model | Rated charge current | Rated discharge current | Battery wire size | Load wire size |
|---|---|---|---|---|
| Tracer1206AN/Tracer1210AN | 10A | 10A | 4mm²/12AWG | 4mm²/12AWG |
| Tracer2206AN/Tracer2210AN | 20A | 20A | 6mm²/10AWG | 6mm²/10AWG |
| Tracer3210AN | 30A | 30A | 10mm²/8AWG | 10mm²/8AWG |
| Tracer4210AN | 40A | 40A | 16mm²/6AWG | 16mm²/6AWG |
3.4 Mounting
The controller should be installed in a location with sufficient airflow around its radiators. A minimum clearance of 150mm from the upper and lower edges is required for natural thermal convection.

Installation Procedure:
- Determine Installation Location and Heat-dissipation Space: Ensure adequate airflow.
- Connect the System: Connect in the order of battery → load → PV array. Disconnect in the reverse order.
- Grounding: The Tracer AN series is a common-negative controller. All negative terminals (PV array, battery, load) can be grounded simultaneously, or any one can be grounded. The shell's grounding terminal must be grounded to shield electromagnetic interference and prevent electric shock.
- Connect Accessories:
- Remote Temperature Sensor (RTS300R47K3.81A): Connect the cable to the designated port and place the other end near the battery. If not connected or damaged, the controller will use a default temperature of 25°C for charging/discharging.
- RS485 Communication: Connect accessories like USB to RS485 cable (CC-USB-RS485-150U), OTG cable (OTG-12CM), eBox-WIFI-01, eBox-BLE-01, or eLOG01 for monitoring and parameter setting via PC software or mobile APP. Refer to the accessories section for details.
- Power On the Controller: Close the battery fuse to power on. Check the battery indicator (green indicates normal operation). Then close the fuses/circuit breakers for the load and PV array. The system will operate in preprogrammed mode.

For detailed wiring diagrams including accessories, please refer to the full PDF user manual available at EPEVER Tracer-AN Series User Manual (PDF).
4. Operation
4.1 Button Functions
| Mode | Note |
|---|---|
| Load ON/OFF | In load manual mode, use the "ENTER" button to turn the load On/Off. |
| Clear Fault | Press the “ENTER” button. |
| Browsing Mode | Press the "SELECT” button. |
| Setting Mode | Press "ENTER" for 5s to enter setting mode. Use "SELECT" to set parameters, "ENTER" to confirm or exit after 10s. |
4.2 Interface Icons and Fault Indications
The LCD displays various icons to indicate system status:
| Item | Icon | Status |
|---|---|---|
| PV array | ☀ | Day |
| 🌙 | Night | |
| ☀︎ / ☁︎ | No charging / Charging | |
| PV | PV | PV Voltage, Current, Power |
| Battery | 🔋 | Battery capacity, In Charging |
| BATT. | Battery Voltage, Current, Temperature | |
| BATT. TYPE | Battery Type | |
| Load | 💡 | Load ON |
| 💡 (crossed out) | Load OFF | |
| LOAD | Load Voltage, Current, Load mode |
Fault Indication
| Status | Icon | Description |
|---|---|---|
| Battery over discharged | 🔋 (empty, blinking) | Battery level empty, battery frame blinks, fault icon blinks. |
| Battery over voltage | 🔋 (full, blinking) | Battery level full, battery frame blinks, fault icon blinks. |
| Battery over temperature | 🔋 (current value, blinking) | Battery level shows current value, battery frame blinks, fault icon blinks. |
| Load failure | 💡 (blinking) | Load overload or short circuit. |
Note: If load current exceeds nominal value by 1.02-1.05, 1.05-1.25, 1.25-1.35, or 1.35-1.5 times, the controller will automatically turn off loads in 50s, 30s, 10s, and 2s respectively.
4.3 Settings
The controller allows for various settings adjustments:
- Clear Generated Energy: Press and hold "ENTER" for 5s under the PV power interface until the value flashes, then press "ENTER" again to clear.
- Switch Battery Temperature Unit: Press and hold "ENTER" for 5s under the battery temperature interface.
- Battery Type: Select from Sealed (Default), Gel, Flooded, or User. For custom parameters, select "User" battery type.
- Battery Voltage Control Parameters: These parameters are for 12V systems at 25°C. Double the values for 24V systems.
| Voltage Parameter | Sealed | Gel | Flooded | User (Range) |
|---|---|---|---|---|
| Over Voltage Disconnect Voltage | 16.0V | 16.0V | 16.0V | 9~17V |
| Charging Limit Voltage | 15.0V | 15.0V | 15.0V | 9~17V |
| Over Voltage Reconnect Voltage | 15.0V | 15.0V | 15.0V | 9~17V |
| Equalize Charging Voltage | 14.6V | - | 14.8V | 9~17V |
| Boost Charging Voltage | 14.4V | 14.2V | 14.6V | 9~17V |
| Float Charging Voltage | 13.8V | 13.8V | 13.8V | 9~17V |
| Boost Reconnect Charging Voltage | 13.2V | 13.2V | 13.2V | 9~17V |
| Low Voltage Reconnect Voltage | 12.6V | 12.6V | 12.6V | 9~17V |
| Under Voltage Warning Reconnect Voltage | 12.2V | 12.2V | 12.2V | 9~17V |
| Under Voltage Warning Voltage | 12.0V | 12.0V | 12.0V | 9~17V |
| Low Voltage Disconnect Voltage | 11.1V | 11.1V | 11.1V | 9~17V |
| Discharging Limit Voltage | 10.6V | 10.6V | 10.6V | 9~17V |
| Equalize Duration | 120 min | - | 120 min | 0~180 min |
| Boost Duration | 120 min | 120 min | 120 min | 10~180 min |
Note: For lithium batteries, specific rules apply for setting control voltage values. Consult the engineer for diversification of lithium battery types.
4.4 Load Working Modes
The controller supports multiple load work modes:
| Mode Code | Timer 1 | Timer 2 |
|---|---|---|
| 100 | Light ON/OFF | Disabled |
| 101 | Load on for 1 hour since sunset | Load on for 1 hour before sunrise |
| 102 | Load on for 2 hours since sunset | Load on for 2 hours before sunrise |
| 103-113 | Load on for 3-13 hours since sunset | Load on for 3-13 hours before sunrise |
| 114 | Load on for 14 hours since sunset | Load on for 14 hours before sunrise |
| 115 | Load on for 15 hours | Load on for 15 hours |
| 116 | Test mode | Disabled |
| 117 | Manual mode (Default load ON) | Disabled |
Note: Timer2 is disabled when Light ON/OFF, Test mode, and Manual mode are set via Timer1.

4.5 Accessories (Optional)
The controller supports various optional accessories for enhanced monitoring and control:
| Accessory | Description |
|---|---|
| Remote Temperature Sensor (RTS300R47K3.81A) | Acquires battery temperature for compensation of control parameters. Standard cable length is 3m. Connects to the 4th port on the controller. |
| USB to RS485 cable (CC-USB-RS485-150U) | Monitors controllers on the network using Solar Station PC software. Cable length is 1.5m. Connects to the RS-485 Port. |
| OTG cable (OTG-12CM) | Connects to mobile devices for real-time monitoring and parameter modification via mobile APP. |
| Remote Meter (MT50) | Displays operating data and faults on a backlit LCD screen. Easy-to-operate with numeric display. |
| WIFI Serial Adapter (eBox-WIFI-01) | Connects controller to mobile APP via WIFI for monitoring and parameter setting. |
| RS485 to Bluetooth Adapter (eBox-BLE-01) | Connects controller to mobile APP via Bluetooth for monitoring and parameter setting. |
| Logger (eLOG01) | Records operating data and monitors real-time status via PC software. |
Note: For detailed setting and operation of accessories, refer to their respective instructions.

5. Maintenance
Regular maintenance is crucial for optimal performance. The following tasks are recommended at least twice per year:
- Ensure the controller is firmly installed in a clean and dry environment.
- Verify there are no obstructions to airflow around the controller. Clean any dirt or fragments from the radiator.
- Check all exposed wires for insulation damage (e.g., from solarization, friction, insects, or rodents). Repair or replace damaged wires as needed.
- Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
- Confirm that the LED indicators are consistent with expected operation. Address any troubleshooting or error indications promptly.
- Ensure all system components are tightly and correctly grounded.
- Check terminals for corrosion, insulation damage, high temperature, or discolored signs. Tighten terminal screws to the suggested torque.
- Inspect for dirt, nesting insects, and corrosion. Clean as necessary.
- Verify the lightning arrester is in good condition. Replace if necessary to prevent damage to the controller and other equipment.
WARNING: Risk of Electric Shock! Always ensure all power is turned off before performing any maintenance or inspection operations.
6. Troubleshooting
This section provides solutions for common issues. If the problem persists, contact customer support.
| Possible Reason | Faults Indication | Troubleshooting |
|---|---|---|
| PV array disconnection | Charging LED indicator off during daytime when sunshine falls on PV modules properly. | Confirm that PV and battery wire connections are correct and tight. |
| Battery voltage is lower than 8V | Wire connection is correct, the controller is not working. | Check the voltage of battery. At least 8V voltage to activate the controller. |
| Battery over voltage | Battery level shows full, battery frame blinks, fault icon blinks. | Check if battery voltage is higher than OVD (over voltage disconnect voltage), and disconnect the PV. |
| Battery over discharged | Battery level shows empty, battery frame blinks, fault icon blinks. | When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover. |
| Battery Overheating | Battery level shows empty, battery frame blinks, fault icon blinks. | The controller will automatically turn the system off. It will resume when temperature declines below 55 °C. |
| Load Overload | 1. The load has no output. 2. Load and fault icon blink. | 1. Reduce the number of electrical equipment. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
| Load Short Circuit | Load and fault icon blink. | 1. Check load connections carefully, clear the fault. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
7. Technical Specifications
7.1 Electrical Parameters (Tracer4210AN)
| Item | Tracer4210AN |
|---|---|
| System nominal voltage | 12/24VDC Auto |
| Rated charge current | 40A |
| Rated discharge current | 40A |
| Battery voltage range | 8~32V |
| Max. PV open circuit voltage | 100V (at 25°C environment temperature) |
| MPP voltage range | (Battery voltage +2V)~72V |
| Max. PV input power | 520W/12V, 1040W/24V |
| Self-consumption | ≤12mA |
| Discharge circuit voltage drop | ≤0.23V |
| Temperature compensate coefficient | -3mV/°C/2V (Default) |
| Grounding | Common negative |
| RS485 interface | 5VDC/100mA |
| LCD backlight time | 60S (Default) |
Note: When a lead-acid battery is used, the controller does not have low temperature protection. At minimum operating environment temperature. At 25°C environment temperature. When a lithium-ion battery is used, the system voltage cannot be identified automatically.
7.2 Environmental Parameters
| Item | Value |
|---|---|
| Working environment temperature | -25℃~+50℃ (100% input and output) |
| Storage temperature range | -20℃~+70℃ |
| Relative humidity | ≤95%, N.C. |
| Enclosure | IP30 |
The controller can operate at full load within the working environment temperature. If the internal temperature reaches 81°C, the reducing power charging mode activates. Refer to the troubleshooting section for more details.
7.3 Mechanical Parameters (Tracer4210AN)
| Item | Tracer4210AN |
|---|---|
| Dimension (L x W x H) | 252x180x63mm |
| Mounting dimension | 210x171mm |
| Mounting hole size | Φ5mm |
| Terminal | 6AWG(16mm²) |
| Recommended cable | 6AWG(16mm²) |
| Weight | 1.65kg |

8. User Tips
- Battery Type Selection: If you need to customize charging parameters, always select "User" battery type in the settings. The default types (Sealed, Gel, Flooded) have fixed parameters.
- Temperature Sensor Importance: Ensure the remote temperature sensor is properly connected and placed near the battery. If it's disconnected or damaged, the controller will default to 25°C, which might not be optimal for your battery's lifespan, especially in varying climates.
- Wiring Order: Always connect the battery first, then the load, and finally the PV array. Disconnect in the reverse order (PV array, then load, then battery) to prevent damage.
- Monitoring: Utilize the optional accessories like the MT50 remote meter or mobile APP connectivity (via eBox-WIFI-01 or eBox-BLE-01) to monitor your system's performance and adjust settings conveniently.
- Weight Consideration: The Tracer4210AN G3 weighs approximately 1.65kg. Factor this into your mounting plans to ensure a secure installation.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.