EPEVER Tracer4210AN G3

Contents

EPEVER Tracer4210AN G3 40A MPPT Solar Charge Controller User Manual

Model: Tracer4210AN G3

1. Overview

The EPEVER Tracer-AN series MPPT Solar Charge Controller, including the Tracer4210AN G3 model, is designed for solar power systems. It features an advanced Maximum Power Point Tracking (MPPT) control algorithm to efficiently harvest energy from solar modules. This controller is suitable for various applications such as RVs, residential systems, and outdoor monitoring.

Key features include:

  • Advanced MPPT technology with efficiency no less than 99.5%.
  • Ultra-fast tracking speed and guaranteed tracking efficiency.
  • Minimizes maximum power point loss rate and loss time.
  • Wide MPP operating voltage range.
  • High-quality components for perfecting system performance, with a maximum conversion efficiency of 98%.
  • Accurate recognition and tracking of multiple-peaks maximum power point.
  • Charging power and current limitation function.
  • Compatible with lead-acid and lithium-ion batteries.
  • Battery temperature compensation function.
  • Real-time energy statistics function.
  • Overheating power reduction function.
  • Multiple load work modes.
  • Professional protection chip for the communication port, providing 5VDC power supply, over-current, and short-circuit protection.
  • RS-485 communication bus interface and Modbus communication protocol for various communication requirements.
  • Monitoring and parameter setting via mobile phone APP or PC software.
  • Full-load operation without capacity drop within the working environment temperature range.
  • Extensive electronic protection.
EPEVER Tracer4210AN G3 MPPT Solar Charge Controller front view
Figure 1.1: EPEVER Tracer4210AN G3 MPPT Solar Charge Controller (Front View)
EPEVER Tracer4210AN G3 MPPT Solar Charge Controller angled view showing terminals
Figure 1.2: EPEVER Tracer4210AN G3 MPPT Solar Charge Controller (Angled View)
Detailed view of the EPEVER Tracer4210AN G3 controller's LCD display, buttons, and terminal connections including solar panel, battery, load, temperature sensor, and COM port.
Figure 1.3: Product Characteristics and Terminal Layout

The controller features an LCD display, SELECT and ENTER buttons for navigation, and various terminals for solar panel, battery, load, temperature sensor, and a COM port (RJ45).

For a visual overview of the product, please watch the following video:

Video 1.1: EPEVER Tracer AN Series MPPT Solar Charge Controller Product Showcase

2. Important Safety Instructions

Please read and save this manual for future reference. This manual contains critical safety, installation, and operation information for the Tracer AN series controller.

General Safety Information

  • Read all instructions and warnings carefully before installation.
  • The controller contains no user-serviceable components. DO NOT disassemble or attempt to repair the controller.
  • Mount the controller indoors, protected from elements and water.
  • Install the controller in a well-ventilated area. The heat sink can become very hot during operation.
  • Install appropriate external fuses/breakers.
  • Switch off all PV array connections and battery fuses/breakers before installation or adjustment.
  • Ensure power connections remain tight to prevent excessive heating from loose connections.

Specific Warnings and Cautions

  • WARNING: Explosive Risk! Equalizing flooded batteries produces explosive gases. Ensure good ventilation for the battery box. Never install the controller in a sealed enclosure with flooded batteries. Battery fumes can corrode and destroy controller circuits.
  • CAUTION: Equipment Damage! Over-charging or excessive gassing can damage battery plates. Review battery requirements carefully. Equalization may increase battery voltage to levels that damage sensitive DC loads. Verify all load allowable input voltages are 11% greater than the equalizing charging set point voltage.
  • WARNING: Risk of Electric Shock! When wiring solar modules, the PV array can produce open circuit voltages exceeding 100V in sunlight.
  • CAUTION: The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
  • CAUTION: When wiring, do not close the circuit breaker or fuse. Ensure positive and negative poles are connected correctly.
  • CAUTION: A fuse (1.25 to 2 times the rated current of the controller) must be installed on the battery side, not more than 150mm from the battery.
  • CAUTION: For areas with frequent lightning strikes, an external surge arrester must be installed.
  • CAUTION: If an inverter is connected, connect it directly to the battery, not to the load side of the controller.
  • CAUTION: For common-negative systems, if common-positive equipment is used and the positive electrode is grounded, the controller may be damaged.
  • WARNING: If the PV array's open-circuit voltage exceeds the "maximum PV open-circuit voltage" rating (e.g., 50V for Tracer**06AN or 96V for Tracer**10AN at lowest environmental temperature), the controller may be damaged.
  • WARNING: If the PV array is reverse connected with 1.5 times rated controller power (watts), the controller will be damaged.
  • WARNING: The required accuracy of the Protection Circuit Module (PCM) for lithium batteries must be at least 0.2V. Deviations higher than 0.2V may lead to system malfunction, for which the manufacturer assumes no liability.
  • WARNING: Before any operations, ensure all power is turned off before performing any maintenance or inspection operations.

3. Installation Instructions

3.1 General Installation Notes

  • Always wear eye protection when handling batteries, especially flooded lead-acid types. Have fresh water available for washing any contact with battery acid.
  • Keep batteries away from metal objects to prevent short circuits.
  • Ensure good ventilation where batteries are charging to dissipate explosive gases.
  • Avoid loose power connections and corroded wires, which can cause overheating and fire. Secure cables with clamps.
  • Lead-acid and lithium batteries are recommended. Consult battery manufacturer for other types.
  • Battery connection can be to a single battery or a bank of batteries.
  • Multiple controllers of the same model can be installed in parallel on the same battery bank for higher charging current. Each controller needs its own solar module(s).
  • Select system cables according to 5A/mm² or less current density, in accordance with Article 690 of the National Electrical Code, NFPA 70.

3.2 PV Array Requirements

The controller is compatible with various PV modules. The number of PV modules in series depends on the open circuit voltage (Voc) and maximum power point voltage (VMpp) of the MPPT controller. The following table provides reference values for the Tracer1210/2210/3210/4210AN models:

System voltage36 cell Voc<23V48 cell Voc<31V54 cell Voc<34V60 cell Voc<38V
Max.BestMax.BestMax.BestMax.Best
12V42212121
24V43222222
System voltage72 cell Voc<46V96 cell Voc<62VThin-Film Module Voc>80V
Max.BestMax.Best
12V21111
24V21111

Note: These values are calculated under standard test conditions (STC: Irradiance 1000W/m², Module Temperature 25℃, Air Mass 1.5).

3.3 Wire Size

Wiring and installation must comply with all national and local electrical code requirements. The following tables provide recommended wire sizes:

PV Wire Size

ModelMax. PV input currentMax. PV wire size*
Tracer1206AN/Tracer1210AN10A4mm²/12AWG
Tracer2206AN/Tracer2210AN20A6mm²/10AWG
Tracer3210AN30A10mm²/8AWG
Tracer4210AN40A16mm²/6AWG

*These are the maximum wire sizes that will fit the controller terminals. Isc = short circuit current (amps), Voc = open circuit voltage.

Battery and Load Wire Size

ModelRated charge currentRated discharge currentBattery wire sizeLoad wire size
Tracer1206AN/Tracer1210AN10A10A4mm²/12AWG4mm²/12AWG
Tracer2206AN/Tracer2210AN20A20A6mm²/10AWG6mm²/10AWG
Tracer3210AN30A30A10mm²/8AWG10mm²/8AWG
Tracer4210AN40A40A16mm²/6AWG16mm²/6AWG

3.4 Mounting

The controller should be installed in a location with sufficient airflow around its radiators. A minimum clearance of 150mm from the upper and lower edges is required for natural thermal convection.

Diagram illustrating multiple load control modes including manual, dusk to dawn with timer, timer, and dusk to dawn, along with extensive protections like low voltage, over temperature, over load, over discharge, over voltage, overcurrent, short circuit, and reverse current protection.
Figure 3.1: Controller Layout and Connections

Installation Procedure:

  1. Determine Installation Location and Heat-dissipation Space: Ensure adequate airflow.
  2. Connect the System: Connect in the order of battery → load → PV array. Disconnect in the reverse order.
  3. Grounding: The Tracer AN series is a common-negative controller. All negative terminals (PV array, battery, load) can be grounded simultaneously, or any one can be grounded. The shell's grounding terminal must be grounded to shield electromagnetic interference and prevent electric shock.
  4. Connect Accessories:
    • Remote Temperature Sensor (RTS300R47K3.81A): Connect the cable to the designated port and place the other end near the battery. If not connected or damaged, the controller will use a default temperature of 25°C for charging/discharging.
    • RS485 Communication: Connect accessories like USB to RS485 cable (CC-USB-RS485-150U), OTG cable (OTG-12CM), eBox-WIFI-01, eBox-BLE-01, or eLOG01 for monitoring and parameter setting via PC software or mobile APP. Refer to the accessories section for details.
  5. Power On the Controller: Close the battery fuse to power on. Check the battery indicator (green indicates normal operation). Then close the fuses/circuit breakers for the load and PV array. The system will operate in preprogrammed mode.
Schematic diagram of a solar power system showing connections between solar panels, MPPT controller, battery, inverter, and household loads.
Figure 3.2: Schematic Wiring Diagram for a Solar Power System

For detailed wiring diagrams including accessories, please refer to the full PDF user manual available at EPEVER Tracer-AN Series User Manual (PDF).

4. Operation

4.1 Button Functions

ModeNote
Load ON/OFFIn load manual mode, use the "ENTER" button to turn the load On/Off.
Clear FaultPress the “ENTER” button.
Browsing ModePress the "SELECT” button.
Setting ModePress "ENTER" for 5s to enter setting mode. Use "SELECT" to set parameters, "ENTER" to confirm or exit after 10s.

4.2 Interface Icons and Fault Indications

The LCD displays various icons to indicate system status:

ItemIconStatus
PV array☀Day
🌙Night
☀︎ / ☁︎No charging / Charging
PVPVPV Voltage, Current, Power
Battery🔋Battery capacity, In Charging
BATT.Battery Voltage, Current, Temperature
BATT. TYPEBattery Type
Load💡Load ON
💡 (crossed out)Load OFF
LOADLoad Voltage, Current, Load mode

Fault Indication

StatusIconDescription
Battery over discharged🔋 (empty, blinking)Battery level empty, battery frame blinks, fault icon blinks.
Battery over voltage🔋 (full, blinking)Battery level full, battery frame blinks, fault icon blinks.
Battery over temperature🔋 (current value, blinking)Battery level shows current value, battery frame blinks, fault icon blinks.
Load failure💡 (blinking)Load overload or short circuit.

Note: If load current exceeds nominal value by 1.02-1.05, 1.05-1.25, 1.25-1.35, or 1.35-1.5 times, the controller will automatically turn off loads in 50s, 30s, 10s, and 2s respectively.

4.3 Settings

The controller allows for various settings adjustments:

  • Clear Generated Energy: Press and hold "ENTER" for 5s under the PV power interface until the value flashes, then press "ENTER" again to clear.
  • Switch Battery Temperature Unit: Press and hold "ENTER" for 5s under the battery temperature interface.
  • Battery Type: Select from Sealed (Default), Gel, Flooded, or User. For custom parameters, select "User" battery type.
  • Battery Voltage Control Parameters: These parameters are for 12V systems at 25°C. Double the values for 24V systems.
Voltage ParameterSealedGelFloodedUser (Range)
Over Voltage Disconnect Voltage16.0V16.0V16.0V9~17V
Charging Limit Voltage15.0V15.0V15.0V9~17V
Over Voltage Reconnect Voltage15.0V15.0V15.0V9~17V
Equalize Charging Voltage14.6V-14.8V9~17V
Boost Charging Voltage14.4V14.2V14.6V9~17V
Float Charging Voltage13.8V13.8V13.8V9~17V
Boost Reconnect Charging Voltage13.2V13.2V13.2V9~17V
Low Voltage Reconnect Voltage12.6V12.6V12.6V9~17V
Under Voltage Warning Reconnect Voltage12.2V12.2V12.2V9~17V
Under Voltage Warning Voltage12.0V12.0V12.0V9~17V
Low Voltage Disconnect Voltage11.1V11.1V11.1V9~17V
Discharging Limit Voltage10.6V10.6V10.6V9~17V
Equalize Duration120 min-120 min0~180 min
Boost Duration120 min120 min120 min10~180 min

Note: For lithium batteries, specific rules apply for setting control voltage values. Consult the engineer for diversification of lithium battery types.

4.4 Load Working Modes

The controller supports multiple load work modes:

Mode CodeTimer 1Timer 2
100Light ON/OFFDisabled
101Load on for 1 hour since sunsetLoad on for 1 hour before sunrise
102Load on for 2 hours since sunsetLoad on for 2 hours before sunrise
103-113Load on for 3-13 hours since sunsetLoad on for 3-13 hours before sunrise
114Load on for 14 hours since sunsetLoad on for 14 hours before sunrise
115Load on for 15 hoursLoad on for 15 hours
116Test modeDisabled
117Manual mode (Default load ON)Disabled

Note: Timer2 is disabled when Light ON/OFF, Test mode, and Manual mode are set via Timer1.

Diagram illustrating multiple load control modes including manual, dusk to dawn with timer, timer, and dusk to dawn, along with extensive protections like low voltage, over temperature, over load, over discharge, over voltage, overcurrent, short circuit, and reverse current protection.
Figure 4.1: Multiple Load Control Modes and Extensive Protections

4.5 Accessories (Optional)

The controller supports various optional accessories for enhanced monitoring and control:

AccessoryDescription
Remote Temperature Sensor (RTS300R47K3.81A)Acquires battery temperature for compensation of control parameters. Standard cable length is 3m. Connects to the 4th port on the controller.
USB to RS485 cable (CC-USB-RS485-150U)Monitors controllers on the network using Solar Station PC software. Cable length is 1.5m. Connects to the RS-485 Port.
OTG cable (OTG-12CM)Connects to mobile devices for real-time monitoring and parameter modification via mobile APP.
Remote Meter (MT50)Displays operating data and faults on a backlit LCD screen. Easy-to-operate with numeric display.
WIFI Serial Adapter (eBox-WIFI-01)Connects controller to mobile APP via WIFI for monitoring and parameter setting.
RS485 to Bluetooth Adapter (eBox-BLE-01)Connects controller to mobile APP via Bluetooth for monitoring and parameter setting.
Logger (eLOG01)Records operating data and monitors real-time status via PC software.

Note: For detailed setting and operation of accessories, refer to their respective instructions.

Wiring diagram showing the EPEVER MPPT Solar Charge Controller connected to various optional accessories including MT50 remote meter, eBox-WIFI-01, eBox-BLE-01, OTG-12CM, eLOG01, and PC for monitoring and control.
Figure 4.2: System Wiring Diagram with Optional Accessories

5. Maintenance

Regular maintenance is crucial for optimal performance. The following tasks are recommended at least twice per year:

  • Ensure the controller is firmly installed in a clean and dry environment.
  • Verify there are no obstructions to airflow around the controller. Clean any dirt or fragments from the radiator.
  • Check all exposed wires for insulation damage (e.g., from solarization, friction, insects, or rodents). Repair or replace damaged wires as needed.
  • Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
  • Confirm that the LED indicators are consistent with expected operation. Address any troubleshooting or error indications promptly.
  • Ensure all system components are tightly and correctly grounded.
  • Check terminals for corrosion, insulation damage, high temperature, or discolored signs. Tighten terminal screws to the suggested torque.
  • Inspect for dirt, nesting insects, and corrosion. Clean as necessary.
  • Verify the lightning arrester is in good condition. Replace if necessary to prevent damage to the controller and other equipment.

WARNING: Risk of Electric Shock! Always ensure all power is turned off before performing any maintenance or inspection operations.

6. Troubleshooting

This section provides solutions for common issues. If the problem persists, contact customer support.

Possible ReasonFaults IndicationTroubleshooting
PV array disconnectionCharging LED indicator off during daytime when sunshine falls on PV modules properly.Confirm that PV and battery wire connections are correct and tight.
Battery voltage is lower than 8VWire connection is correct, the controller is not working.Check the voltage of battery. At least 8V voltage to activate the controller.
Battery over voltageBattery level shows full, battery frame blinks, fault icon blinks.Check if battery voltage is higher than OVD (over voltage disconnect voltage), and disconnect the PV.
Battery over dischargedBattery level shows empty, battery frame blinks, fault icon blinks.When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover.
Battery OverheatingBattery level shows empty, battery frame blinks, fault icon blinks.The controller will automatically turn the system off. It will resume when temperature declines below 55 °C.
Load Overload1. The load has no output. 2. Load and fault icon blink.1. Reduce the number of electrical equipment. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours).
Load Short CircuitLoad and fault icon blink.1. Check load connections carefully, clear the fault. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours).

7. Technical Specifications

7.1 Electrical Parameters (Tracer4210AN)

ItemTracer4210AN
System nominal voltage12/24VDC Auto
Rated charge current40A
Rated discharge current40A
Battery voltage range8~32V
Max. PV open circuit voltage100V (at 25°C environment temperature)
MPP voltage range(Battery voltage +2V)~72V
Max. PV input power520W/12V, 1040W/24V
Self-consumption≤12mA
Discharge circuit voltage drop≤0.23V
Temperature compensate coefficient-3mV/°C/2V (Default)
GroundingCommon negative
RS485 interface5VDC/100mA
LCD backlight time60S (Default)

Note: When a lead-acid battery is used, the controller does not have low temperature protection. At minimum operating environment temperature. At 25°C environment temperature. When a lithium-ion battery is used, the system voltage cannot be identified automatically.

7.2 Environmental Parameters

ItemValue
Working environment temperature-25℃~+50℃ (100% input and output)
Storage temperature range-20℃~+70℃
Relative humidity≤95%, N.C.
EnclosureIP30

The controller can operate at full load within the working environment temperature. If the internal temperature reaches 81°C, the reducing power charging mode activates. Refer to the troubleshooting section for more details.

7.3 Mechanical Parameters (Tracer4210AN)

ItemTracer4210AN
Dimension (L x W x H)252x180x63mm
Mounting dimension210x171mm
Mounting hole sizeΦ5mm
Terminal6AWG(16mm²)
Recommended cable6AWG(16mm²)
Weight1.65kg
Side view of the EPEVER Tracer4210AN G3 MPPT Solar Charge Controller, showing the heat sink fins.
Figure 7.1: Tracer4210AN G3 Side View (Heat Sink)

8. User Tips

  • Battery Type Selection: If you need to customize charging parameters, always select "User" battery type in the settings. The default types (Sealed, Gel, Flooded) have fixed parameters.
  • Temperature Sensor Importance: Ensure the remote temperature sensor is properly connected and placed near the battery. If it's disconnected or damaged, the controller will default to 25°C, which might not be optimal for your battery's lifespan, especially in varying climates.
  • Wiring Order: Always connect the battery first, then the load, and finally the PV array. Disconnect in the reverse order (PV array, then load, then battery) to prevent damage.
  • Monitoring: Utilize the optional accessories like the MT50 remote meter or mobile APP connectivity (via eBox-WIFI-01 or eBox-BLE-01) to monitor your system's performance and adjust settings conveniently.
  • Weight Consideration: The Tracer4210AN G3 weighs approximately 1.65kg. Factor this into your mounting plans to ensure a secure installation.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.