1. Product Overview
The Tracer-AN G3 series controllers, based on a new design concept, are advanced MPPT solar charge controllers. They are designed to efficiently manage power from solar panels to charge batteries and power loads in various applications, including RVs, household systems, and outdoor monitoring.
These controllers utilize an advanced MPPT control algorithm to minimize power loss and maximize energy harvesting from the PV array. Compared to traditional PWM charging, MPPT solar controllers can increase energy utilization by 10%-30%. Features like charging current limit, charging power limit, and high-temperature charging automatic power reduction ensure system stability even with excess PV modules or high operating temperatures.
The Tracer-AN series features a self-adaptive three-stage charging mode based on a digital control circuit, which effectively prolongs battery lifespan and improves system performance. Comprehensive electronic protections ensure reliability and durability.
Key Features:
- High-quality components (ST or IR) for extended service life.
- Advanced MPPT technology with a maximum tracking efficiency higher than 99.5%.
- MPPT control algorithm minimizes lost rate and time.
- Accurate recognition and tracking of multi-peak maximum power points.
- Wider Maximum Power Point (MPP) running voltage to optimize PV utilization.
- Maximum DC/DC conversion efficiency of 98%.
- Supports multiple battery types, including lithium batteries.
- Equipped with a stable self-activation function for lithium batteries.
- Battery voltage parameters can be set on the LCD.
- Battery temperature compensation.
- Limits charging power and current to no higher than the rated value.
- Real-time energy statistics function.
- Automatic charging power reduction for over-temperature conditions.
- RS485 communication interface with optional 4G or Wi-Fi modules for remote monitoring.
- Standard Modbus communication protocol for extended communication distance.
- Power protection chip for RS485 port (5VDC/200mA, over-current, short-circuit protections).
- Parameters can be set via PC software, APP, or remote meter.
- Constant voltage output function.
- Comprehensive electronic protections.
- Multiple load work modes.
- Low self-consumption (lower than 10mA).
- Operation at full load without charging power reduction in the working temperature range.



2. Important Safety Instructions
Please keep this manual for future reference. This manual contains the safety, installation, and operation instructions for the Tracer-AN G3 series MPPT solar charge controller.
General Safety Guidelines:
- Read all instructions and warnings carefully in the manual before installation.
- No user-serviceable components are inside the controller. Do not disassemble or attempt to repair the controller.
- Mount the controller indoors. Avoid exposure to components and do not allow water to enter the controller.
- Install the controller in a well-ventilated place. The controller's heat sink may become hot during operation.
- It is suggested to install appropriate external fast-acting fuses/breakers.
- Disconnect PV array connections and the battery's fast-acting fuse/breakers before controller installation and adjustment.
- Power connections must remain tight to avoid excessive heating from a loose connection.
NOTICE:
Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
Disclaimers:
The warranty does not apply to the following conditions:
- Damage caused by improper use or inappropriate environment (such as humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments).
- The actual current/voltage/power exceeds the limit value of the controller.
- Damage caused by working temperature exceeding the rated range.
- Arc, fire, explosion, and other accidents caused by failure to follow the controller stickers or manual instructions.
- Unauthorized dismantling or attempted repair.
- Damage caused by force majeure.
- Damage occurred during transportation or handling.
3. Installation Instructions
3.1 Installation Precautions:
- Read the instructions to familiarize yourself with the installation steps before installation.
- Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
- Be careful when installing the batteries. Wear eye protection when installing open-type lead-acid batteries and rinse with clean water immediately if battery acid contacts skin.
- Keep the battery away from any metal objects to prevent short circuits.
- Acid gas may be generated when the battery is charged. Ensure the surrounding environment is well ventilated.
- Avoid direct sunlight and rain infiltration when installing outdoors.
- Loose power connectors and corroded wires may produce high heat, melting wire insulation, burning surrounding materials, or causing a fire. Ensure tight connections and secure cables with cable clamps to prevent swaying in moving applications.
- Only charge lead-acid and lithium-ion batteries within the control range of this controller.
- The battery connector may be wired to another battery or a bank of batteries. The following instructions refer to a singular battery, but the connection can be made to either one battery or a group of batteries in a battery bank.
- Select system cables according to 5A/mm² or less current density.
- The grounding wire size should not be less than 4mm².
- The torque for tightening wiring screws should not be less than 1.2 N·m.
3.2 Requirements for the PV Array:
The controller needs to suit various types of PV modules and maximize solar energy conversion. The serial connection of PV modules suitable for different controllers can be calculated based on the open-circuit voltage (Voc) and the maximum power point voltage (VMPP) of the MPPT controller.
NOTICE:
The total voltage must not exceed the PV maximum open-circuit voltage when the PV modules are connected in series. The PV maximum open-circuit voltage is 46V (Tracer**06AN G3) or 92V (Tracer**10AN G3) at 25°C environment temperature.
3.3 Wire Size:
The wiring and installation methods must conform to national and local electrical code requirements.
PV Wire Size:
The PV array's output current varies with size, connection method, and sunlight angle. The minimum wire size can be calculated using the ISC (short circuit current) from the PV module's specifications. When PV modules are connected in series, the total ISC equals any PV module's ISC. When PV modules are connected in parallel, the total ISC equals the sum of the PV module's ISC. The PV array's ISC must not exceed the controller's maximum PV input current.
| Model | Max. PV Input Current | Max. PV Wire Size | Circuit Breaker |
|---|---|---|---|
| Tracer1206/1210AN G3 | 10A | 4mm²/12AWG | 16A/125V/2 P |
| Tracer2206/2210AN G3 | 20A | 6mm²/10AWG | 32A/125V/2 P |
| Tracer3210AN G3 | 30A | 10mm²/8AWG | 40A/125V/2 P |
| Tracer4210AN G3 | 40A | 16mm²/6AWG | 63A/125V/2 P |
Battery and Load Wire Size:
The battery and load wire size should conform to the rated current.
| Model | Rated Charge Current | Rated Discharge Current | Battery Wire Size | Load Wire Size | Circuit Breaker |
|---|---|---|---|---|---|
| Tracer1206/1210AN G3 | 10A | 10A | 4mm²/12AWG | 4mm²/12AWG | 16A/125V/2 P |
| Tracer2206/2210AN G3 | 20A | 20A | 6mm²/10AWG | 6mm²/10AWG | 32A/125V/2 P |
| Tracer3210AN G3 | 30A | 30A | 10mm²/8AWG | 10mm²/8AWG | 40A/125V/2 P |
NOTICE:
- The wire size is only for reference. If there is a long distance between the PV array and the controller or between the controller and the battery, larger wires can be used to reduce voltage drop and improve performance.
- The recommended wire is selected for the battery according to the conditions that its terminals are not connected to any additional inverter.
3.4 Mounting:
DANGER:
- Explosion hazard! Never install the controller in a sealed enclosure with FLD batteries! Do not install the controller in a confined area where battery gas can accumulate.
- Electric shock hazard! The PV array may generate a high open-circuit voltage when wiring the PV modules. Disconnect the breaker or fast-acting fuse first, and be careful when wiring.
The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
Step 1: Determine Installation Location and Heat-Dissipation Space.

Step 2: Connect the System (Wiring Diagram)
Connect the system in the order of ①battery > ②load > ③PV array. Disconnect in the reverse order.

NOTICE:
- Do not connect the circuit breaker or fast-acting fuse during wiring. Ensure electrode polarity is correctly connected.
- A fast-acting fuse (1.25 to 2 times the controller's rated current) must be installed on the battery side, no longer than 150mm from the battery.
- The cable length of the battery should not exceed 3 meters.
- The recommended cable length of the PV array should not exceed 3 meters. (Note: If the cable length of the PV array is less than 3 meters, the system meets EN/IEC61000-6-3 requirements. If more than 3 meters, the system may not meet EN/IEC61000-6-3 requirements).
- If the controller is used in an area with frequent lightning strikes or an unattended area, an external surge arrester must be installed.
- If an inverter is to be connected to the system, connect the inverter directly to the battery, not to the load side of the controller.
Step 3: Grounding
Tracer-AN G3 series are common-negative controllers. Negative terminals of the PV array, the battery, and the load can be grounded simultaneously, or any negative terminal can be ungrounded. However, the grounding terminal on the controller's shell must be grounded to shield electromagnetic interference and avoid electric shock.
NOTICE:
It is recommended to use a common-negative controller for common-negative systems, such as RV systems. The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in the common-negative system.
Step 4: Connect Accessories
Connect the temperature sensor:
| Accessory Type | Description | Model | Image |
|---|---|---|---|
| Included Accessory | Connect the temperature sensor | RT-MF58R47K3.81A | ![]() |
| Optional Accessory | Remote temperature sensor | RTS300R47K3.81A | ![]() |
NOTICE:
If the remote temperature sensor is not connected or is damaged, the controller will charge or discharge the battery at the default 25 °C (no temperature compensation).
Connect the accessories for RS485 communication: Refer to Section 4.3 Setting for details.
Note:
The internal circuit of the RS485 port has no isolation design. Connecting an RS485 communication isolator to the port is recommended before communicating.
Step 5: Power on the Controller
Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (the controller operates normally when the indicator is lit green). Connect the fast-acting fuse and circuit breaker of the load and PV array. The system will then operate in preprogrammed mode.
Note:
If the controller is not operating properly or the battery indicator on the controller shows an abnormality, please refer to Section 7. Troubleshooting.
4. Operation
4.1 LCD Display and Buttons:
The display screen can be viewed clearly when the angle between the end-user's horizontal sight and the display screen is within 90°. If the angle exceeds 90°, the information on the display screen cannot be viewed clearly.
| Mode | Note |
|---|---|
| Load ON/OFF | Turn the load On/Off via the ENTER button in manual load mode. |
| Clear fault | Press the ENTER button. |
| Browsing mode | Press the SELECT button. |
| Setting mode | Press the ENTER button and hold for 5s to enter setting mode. Press the SELECT button to set parameters. Press the ENTER button to confirm settings or no operation for 10s to exit automatically. |
4.2 Battery Charging Stages:
The controller employs a three-stage battery charging algorithm: Bulk Charging, Constant Charging (Equalize/Boost), and Float Charging. This method helps extend the battery's lifespan.

a) Bulk Charging:
The battery voltage has not yet reached the constant voltage (Equalize or Boost Charging Voltage). The controller operates in constant current mode, delivering its maximum current to the batteries (MPPT Charging). When the battery voltage reaches the constant voltage set point, the controller will start to operate in constant charging mode.
b) Constant Charging:
When the battery voltage reaches the constant voltage set point, the controller enters constant charging mode. MPPT charging stops, and the charging current gradually drops. Constant charging has two stages: equalize charging and boost charging. These processes are not repeated. Equalized charging starts on the 28th of each month.
- Boost Charging: The default duration of the boost charging stage is generally 2 hours. This duration and preset value can be adjusted. The system switches to float charging when the duration equals the set value.
DANGER:
Explosion hazard! Equalizing FLD batteries produces explosive gases. Well ventilation of the battery box is recommended.
NOTICE:
- Equalization may increase battery voltage to a level that damages sensitive DC loads. Verify that the load's allowable input voltages are greater than the equalize charging voltage.
- Over-charging and excessive gas precipitation can damage battery plates and activate material shedding. Too high an equalized charging or for too long can cause damage. Carefully review the specific requirements of the battery used in the system.
Some battery types benefit from equalizing charging, which stirs electrolytes, balances battery voltage, and facilitates chemical reactions. Equalize charging increases battery voltage above the standard complement voltage, gasifying the battery electrolyte.
If the controller automatically controls the next charge for equalizing charging, the equalizing charging time is 120 minutes. Equalize and boost charges are not carried out constantly in a full charge process to avoid too much gas precipitation or overheating of the battery.
NOTICE:
- Due to installation environment or load work, the system may not stabilize the battery voltage at a constant voltage. The controller will accumulate the time when the battery voltage is equal to the set value. When the accumulative time is equal to 3 hours, the system will automatically switch to float charging.
- If the controller time is not adjusted, the controller will equalize charging following its internal timer.
c) Float Charging:
After the constant charging stage, the controller reduces the battery voltage to the float charging preset voltage by reducing the charging current. During the floating charge stage, the battery is weakly charged to maintain a fully charged state. Loads can obtain almost all power from the solar panel. If loads' power exceeds the solar array's power, the controller will no longer maintain the battery voltage in the float charging stage. When the battery voltage drops below the boost voltage reconnect voltage, the system exits float charging and re-enters bulk charging.
4.3 Setting Parameters:
a) Primary and Secondary Modes:
The Primary mode is used for BMS communication. The Secondary mode is used for RS485 communication, allowing battery parameters to be set remotely via PC host computer software or APP. To switch modes: Press the SELECT button to switch to the first TYPE interface; press ENTER, and the value will flash; press SELECT to switch the mode ('nn' for primary, 'S' for secondary); press ENTER to confirm.
b) BMS Protocol Number:
When using lithium batteries with BMS, after connecting the controller to a BMS-Link module and lithium batteries, the BMS protocol number allows conversion of different lithium battery manufacturers' protocols into standard protocols. This enables communication between the controller and the lithium battery BMS. The BMS protocol number can be found on the manufacturers' websites. Normal communication requires proper setting of this number.
To set the BMS protocol number: In Primary mode (first TYPE interface displays 'nn'), press SELECT to switch to the second TYPE interface; press ENTER to switch to the BMS protocol number (default 01, scope: 0-231); press SELECT to confirm.
After the controller reads BMS detection:
- Charging/discharging switch logic control is based on BMS detection.
- Available BMS protection voltage is read, and actual working voltage can be predicted. If BMS is disconnected or invalid, the device works based on the set voltage.
- Available BMS current limit is read, and current limit charging is conducted based on the smaller of the BMS current limit and the originally set current limit.
c) Clear Generated Energy:
Step 1: Press and hold the ENTER button for 5s under the PV-generated energy interface; the value will flash.
Step 2: Press the ENTER button to clear the generated energy.
d) Switch Battery Temperature Unit:
Press and hold the button for 5s under the battery temperature interface to switch the temperature unit.
e) Battery Type Settings:
The controller supports various battery types. You can set the battery type locally or remotely.
Supported Battery Types:
- Battery: Sealed (default), Gel, FLD
- Lithium battery: LiFePO4 (4S/12V; 8S/24V), Li(NiCoMn)O2 (3S/12V; 6S/24V; 7S/24V)
- User: Customizable parameters
Local Setting of Battery Type:
Step 1: Press the SELECT button to jump to the battery voltage interface.
Step 2: Press and hold the ENTER button until the battery-type interface flashes.
Step 3: Press the SELECT button to change the battery type (e.g., Sealed, Gel, FLD, LCNM3S, LFP8S, LFP4S, LCNM6S, LCNM7S, User).
Step 4: Press the ENTER button to confirm.
Under the "USE" battery type, specific battery parameters can be set via the LCD. For other battery types, parameters are fixed.
Remote Setting of Battery Parameters:
Before setting battery parameters remotely, the communication mode must be set to Secondary mode.
By PC Software: Connect the controller's RJ45 port to the PC's USB interface via a USB to RS485 cable. When selecting "USE" as the battery type, set voltage parameters using the PC software.
By APP (via external WiFi 2.4G adapter): Connect the controller to an external WiFi 2.4G adapter via the RS485 communication port. Set voltage parameters via the APP after selecting "USE" as the battery type. Refer to the cloud APP manual for details.
By APP (via external Bluetooth adapter): Connect the controller to an external Bluetooth adapter via the RS485 communication port. Set voltage parameters via the APP after selecting "USE" as the battery type. Refer to the cloud APP manual for details.
By MT52 Remote Meter: Connect the controller to the MT52 remote meter via a standard network cable. After selecting "USE" as the battery type, set voltage parameters using the MT52. Refer to the MT52 manual for details.
f) Load Modes:
The controller offers multiple load control modes:
| Mode Code | Timer 1 Description | Timer 2 Description |
|---|---|---|
| 100 | Light ON/OFF | Disabled |
| 101 | Load ON for 1 hour since sunset | Load ON for 1 hour before sunrise |
| 102 | Load ON for 2 hours since sunset | Load ON for 2 hours before sunrise |
| 103-113 | Load ON for 3-13 hours since sunset | Load ON for 3-13 hours before sunrise |
| 114 | Load ON for 14 hours since sunset | Load ON for 14 hours before sunrise |
| 115 | Load ON for 15 hours since sunset | Load ON for 15 hours before sunrise |
| 116 | Test mode | Disabled |
| 117 | Manual mode (Default load ON) | |
| 118 | Always ON mode (suitable for 24-hour power supply) | Disabled |
Note:
When selecting Light ON/OFF, Test mode, and Manual mode, only Timer 1 can be set, and Timer 2 is disabled and displays "2n".
Setting Load Mode: Set load modes via PC software, APP, or remote meter (MT52). Refer to Subsection 4.3.e for detailed connection diagrams and settings.
5. Extensive Protections
The Tracer-AN G3 series controller incorporates comprehensive electronic protections to ensure system reliability and durability.

| Protection | Instruction |
|---|---|
| PV Overcurrent | If the actual PV array's charging current or power exceeds the controller's rated values, the controller will charge the battery at the rated current or power. |
| PV Short-circuit | The controller will not be damaged if the PV array is short-circuited when not in the PV charging state. Note: It is forbidden to short-circuit the PV array during charging, as this may damage the controller. |
| PV Reverse Polarity | If the PV array polarity is reversed, the controller will not be damaged and can operate normally after correction. Note: If the PV array is reversed and its actual power is 1.5 times the controller's rated power, the controller may be damaged. |
| Night Reverse Charging | Prevents the battery from discharging to the PV module at night. |
| Battery Reverse Polarity | The battery can be reversely connected when the PV is disconnected or reversely connected. Correct the wire connection to resume work. Note: The controller will be damaged if the PV connection is correct and the battery connection is reversed! |
| Battery Overvoltage | When the battery voltage reaches the overvoltage disconnect voltage, the PV array automatically stops charging to prevent battery damage. |
| Battery Over-discharging | Battery discharging automatically stops when the battery voltage is lower than the low voltage disconnect voltage. |
| Battery Overheating | The controller detects battery temperature via an external sensor. The battery stops working if its temperature exceeds 65°C and resumes below 55°C. |
| Lithium Battery Low Temperature | If the temperature detected by the optional temperature sensor is lower than the Low-Temperature Protection Threshold (LTPT), the controller stops charging and discharging. It resumes when the temperature is higher than LTPT (default 0°C, settable -40°C to 10°C). |
| Load Short Circuit | If a short circuit occurs on the load side (four times the rated load current), the controller automatically cuts off output. It attempts to resume five times (delay 5s, 10s, 15s, 20s, 25s). To restart auto-recovery, press the Load button, restart the controller, or wait for a night-to-day change (night time > 3 hours). |
| Overload | If the load current exceeds 1.05 times the controller's rating, the controller cuts off output after a delay. It attempts to resume five times (delay 5s, 10s, 15s, 20s, 25s). To restart auto-recovery, press the Load button, restart the controller, or wait for a night-to-day change (night time > 3 hours). |
| Device Overheating | An internal temperature sensor detects controller temperature. The controller stops working if internal temperature is higher than 85°C and resumes below 75°C. When internal temperature reaches 81°C, charging power is automatically reduced (5%, 10%, 20%, 40% for each 1°C increase). If it exceeds 85°C, charging stops. Resumes below 75°C. |
| TVS High Voltage Transients | The controller's internal circuitry includes Transient Voltage Suppressors (TVS) for protection against high-voltage surge pulses with less energy. For areas with frequent lightning strikes, an external surge arrester is recommended. |
6. Maintenance
The following inspections and maintenance tasks are recommended at least twice yearly for good performance:
- Ensure no block on airflow around the controller. Clear any dirt and fragments on the radiator.
- Check all naked wires to ensure insulation is not damaged by sun exposure, frictional wear, dryness, insects, or rats. Repair or replace wires if necessary.
- Verify the indicator display is consistent with actual operation. Pay attention to any troubleshooting or error conditions and take necessary corrective action.
- Confirm that terminals have no corrosion, damaged insulation, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
- Clear dirt, nesting insects, and corrosion in time.
- Check and confirm that the lightning arrester is in good condition. Replace if necessary to avoid damaging the controller and other equipment.
DANGER:
Electric shock hazard! Ensure the power is turned off before performing any maintenance operations, and then follow the corresponding inspections and operations.
7. Troubleshooting
This section provides solutions for common issues you might encounter with your Tracer3210AN G3 controller.
| Fault | Faults Description | Troubleshooting |
|---|---|---|
| PV array open-circuit | When there is plenty of direct sunlight on the PV array, the LCD shows no PV input. | Confirm whether the connection of the PV array is correct and tight. |
| The battery voltage is lower than 8V. | The wire connection is correct; the controller is not working. | Check the battery's voltage (at least 8V is needed to activate the controller). |
| Battery overvoltage | Battery frame blink, fault icon blink. | Check whether the battery voltage is higher than OVD (overvoltage disconnect voltage) and disconnect the PV array connection. |
| Battery over-discharged | Battery frame blink, fault icon blink. | ① When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover. ② Take other ways to recharge the battery. |
| Battery overheating | Battery frame blink, fault icon blink. | While the temperature declines below 55°C, the controller will resume. |
| Overload | Load and fault icon blink. | ① Reduce the number of electric devices. ② Restart the controller or press the button to clear faults. |
| Load short-circuit | Load and fault icon blink. | ① Check carefully load connections, clear the fault. ② Restart the controller or press the button to clear faults. |
8. Technical Specifications
The following tables detail the electrical, environmental, and mechanical parameters for the Tracer-AN G3 series, including the Tracer3210AN G3 model.
Electrical Parameters:
| Parameter | Tracer1206AN G3 | Tracer2206AN G3 | Tracer1210AN G3 | Tracer2210AN G3 | Tracer3210AN G3 | Tracer4210AN G3 |
|---|---|---|---|---|---|---|
| Battery Rated Voltage | 12/24VDC Auto-recognition | |||||
| Rated Charging Current | 10A | 20A | 10A | 20A | 30A | 40A |
| Rated Discharge Current | 10A | 20A | 10A | 20A | 30A | 40A |
| Controller Work Voltage Range | 8-31V | |||||
| PV Maximum Open-circuit Voltage | 60V (At minimum operating environment temperature) 46V (At 25°C) | 100V (At minimum operating environment temperature) 92V (At 25°C) | ||||
| MPPT Voltage Range | (Battery voltage + 2V) to 36V | (Battery voltage + 2V) to 72V | ||||
| Rated Charging Power | 130W/12V 260W/24V | 260W/12V 520W/24V | 130W/12V 260W/24V | 260W/12V 520W/24V | 390W/12V 780W/24V | 520W/12V 1040W/24V |
| Static Losses | ≤ 8mA (12V) ≤ 5mA (24V) | |||||
| Discharge-circuit Voltage Drop | ≤ 0.23V | |||||
| Temperature Compensation | -3mV/°C/2V (Default) | |||||
| Grounding Type | Common negative | |||||
| RS485 Port | 5VDC/200mA (RJ45) | |||||
| LCD Backlight Time | Default: 60s, Range: 0-999s (0s: backlight is ON all the time) | |||||
Environmental Parameters:
| Parameter | Value |
|---|---|
| Work Temperature Range | -25°C to +45°C (100% loads working) |
| Storage Temperature Range | -20°C to +70°C |
| Relative Humidity | < 95% (N.C.) |
| Enclosure | IP30 |
Mechanical Parameters:
| Parameter | Tracer1206/1210AN G3 | Tracer2206/2210AN G3 | Tracer3210AN G3 | Tracer4210AN G3 |
|---|---|---|---|---|
| Dimension (L × W × H) | 172mm × 139mm × 44mm | 220mm × 154mm × 52mm | 228mm × 164mm × 55mm | 252mm × 180mm × 63mm |
| Mounting Size (L × W) | 124mm × 130mm | 170mm × 145mm | 170mm × 155mm | 204mm × 171mm |
| Mounting Hole Size | Φ5mm | |||
| Terminal | 12AWG (4mm²) | 6AWG (16mm²) | 6AWG (16mm²) | 6AWG (16mm²) |
| Recommended Wire Size | 12AWG (4mm²) | 10AWG (6mm²) | 8AWG (10mm²) | 6AWG (16mm²) |
| Net Weight | 0.57kg | 0.94kg | 1.26kg | 1.65kg |
9. User Tips
- Always double-check all wiring connections, especially polarity, before powering on the controller to prevent damage.
- Ensure your battery type settings on the controller match your actual battery to optimize charging and prolong battery life.
- For optimal performance and longevity, ensure adequate ventilation around the controller to prevent overheating.
- If using an inverter, connect it directly to the battery terminals, not to the load terminals of the controller, to avoid potential issues.
- Regularly inspect wiring and terminals for tightness and signs of wear or corrosion as part of routine maintenance.
10. Warranty and Support
EPEVER products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please contact EPEVER customer support. Keep your purchase receipt as proof of purchase for warranty claims.
11. Contact Information
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
Phone: +86-752-3889706
Email: info@epever.com
Website: www.epever.com