EPEVER TRACER AN series (2210AN, 3210AN, 4210AN)

Contents

EPEVER TRACER MPPT Solar Charge Controller User Manual

Models: TRACER AN series (2210AN, 3210AN, 4210AN)

1. Introduction

The EPEVER Tracer AN series MPPT solar charge controller is an advanced, efficient, and economical product designed for solar power systems. It features a common negative design and an advanced Maximum Power Point Tracking (MPPT) control algorithm, which minimizes power point loss rate and quickly tracks the maximum power point of the PV array. This ensures maximum energy extraction from solar modules under various conditions.

The controller utilizes a three-stage charging mode based on a digital control circuit, effectively prolonging battery life. It incorporates comprehensive electronic protection functions, including overcharging and over-discharging protection, to prevent damage from incorrect installation or system failure. This modular solar controller is suitable for a wide range of applications, including communication base stations, household systems, and field monitoring.

Key Features:

  • Advanced MPPT technology with efficiency no less than 99.5%.
  • Ultra-fast tracking speed and guaranteed tracking efficiency.
  • Advanced MPPT control algorithm to minimize maximum power point loss rate and loss time.
  • Wide MPP operating voltage range.
  • High-quality components ensuring system performance with maximum conversion efficiency of 98%.
  • Accurate recognition and tracking of multiple-peaks maximum power point.
  • Charging power and current limitation function.
  • Compatible with lead-acid and lithium-ion batteries.
  • Battery temperature compensation function.
  • Real-time energy statistics function.
  • Overheating power reduction function.
  • Multiple load work modes.
  • Communication port with professional protection chip, providing 5VDC power supply, over-current, and short-circuit protection.
  • RS-485 communication bus interface and Modbus communication protocol for versatile communication requirements.
  • Monitor and set parameters via mobile phone APP or PC software.
  • Full-load operation without capacity drop within the working environment temperature range.
  • Extensive electronic protection.

2. Safety Instructions

Please read all instructions and warnings in this manual carefully before installation and operation. Keep this manual for future reference.

  • Ensure all wiring is correctly sized and terminated.
  • Always connect the battery first, then the solar panel, and finally the load. Disconnect in reverse order.
  • Do not short-circuit the battery terminals or solar panel terminals.
  • Ensure proper ventilation around the controller.
  • Avoid exposure to water or excessive humidity.
  • Only qualified personnel should perform installation and maintenance.

3. Product Overview

3.1 Product Characteristics and Components

EPEVER Tracer MPPT Solar Charge Controller front view
Front view of the EPEVER Tracer MPPT Solar Charge Controller.
EPEVER Tracer MPPT Solar Charge Controller bottom terminals
Bottom view showing terminals of the EPEVER Tracer MPPT Solar Charge Controller.
Diagram identifying product characteristics: SELECT button, RTS interface, PV terminals, Battery terminals, Load terminals, RS485 communication interface, Mounting Hole, ENTER button, LCD
Figure 1: Product Characteristics and Component Identification.

Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature setting of 25°C.

3.2 Model Naming Convention:

Example of Tracer model naming convention: Tracer 1210 AN, indicating Common Negative System, Max. PV open circuit voltage 100V, System Voltage 12/24VDC, Charge & discharge current 10A, Product Series
Example: Tracer 1210 AN model breakdown.

The model number indicates key specifications:

  • Tracer: Product Series
  • 12: Charge & discharge current (e.g., 10A, 20A, 30A, 40A)
  • 10: System Voltage (12V/24VDC)
  • AN: Max. PV open circuit voltage (100V) and Common Negative System

4. Installation and Setup

4.1 Mounting the Controller

Mount the controller vertically on a wall or other suitable surface. Ensure adequate airflow around the unit for heat dissipation. Use the mounting holes provided.

Top-down dimension diagram of the EPEVER Tracer controller, showing mounting hole positions and overall dimensions.
Controller Mounting Dimensions (Example: Tracer 1210AN/2210AN).
Bottom-up dimension diagram of the Tracer4210AN controller, showing mounting hole positions and overall dimensions.
Controller Mounting Dimensions (Example: Tracer 4210AN).

4.2 Wiring Connections

Follow the connection sequence carefully to avoid damage. Always connect the battery first, then the solar panel, and finally the DC load.

  1. Connect the Battery: Connect the battery to the controller's battery terminals (marked with + and -). Ensure correct polarity.
  2. Connect the DC Load: Connect the DC load to the controller's load terminals (marked with a light bulb icon). Ensure correct polarity.
  3. Connect the Solar Panel: Connect the solar panel to the controller's PV terminals (marked with a solar panel icon). Ensure correct polarity.
Wiring diagram showing connections for battery, DC load, and solar panel to the EPEVER Tracer MPPT Solar Charge Controller. Includes fuses for battery and load.
Connecting Step: Battery, DC Load, and Solar Panel.

Important: Ensure all connections are tight and secure. Incorrect wiring can damage the controller or other components.

4.3 Accessory Connections

The controller supports various accessories for enhanced monitoring and control. Refer to the specific accessory's instructions for detailed setup.

Diagram showing the EPEVER Tracer controller connected to various accessories like Remote Temperature Sensor (RTS), MT50 Remote Meter, eBox-WiFi-01, eBox-BLE-01, eLOG01, and PC via USB or RS485.
Accessory Connection Diagram.
Accessory Descriptions
Item Icon Description
Remote Temperature Sensor (RTS300R47K3.81A) Remote Temperature Sensor icon Acquisition of battery temperature for undertaking temperature compensation of control parameters. Standard length is 3m (customizable). RTS300R47K3.81A connects to the port (4th) on the controller. NOTE: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature 25°C.
USB to RS485 cable (CC-USB-RS485-150U) USB to RS485 cable icon Used to monitor each controller on the network using Solar Station PC software. Length is 1.5m. The CC-USB-RS485-150U connects to the RS-485 Port on the controller.
OTG cable (OTG-12CM) OTG cable icon Used to connect a mobile communication cable and achieve real-time monitoring of the controller and modification of parameters by using mobile APP software.
Remote Meter (MT50) Remote Meter MT50 icon MT50 can display various operating data and fault of the system. The information is displayed on a backlit LCD screen, the buttons are easy-to-operate, and the numeric display is readable.
WiFi Serial Adapter (eBox-WIFI-01) WiFi Serial Adapter eBox-WIFI-01 icon After the controller is connected with the eBox-WIFI-01 through the standard Ethernet cable (parallel cable), the operating status and related parameters of the controller can be monitored by the mobile APP software through WiFi signals.
RS485 to Bluetooth Adapter (eBox-BLE-01) RS485 to Bluetooth Adapter eBox-BLE-01 icon After the controller is connected with the eBox-BLE-01 through the standard Ethernet cable (parallel cable), the operating status and related parameters of the controller can be monitored by the mobile APP software through Bluetooth signals.
eLogger (eLOG01) eLogger eLOG01 icon After the controller is connected with the eLOG-01 through the RS485 communication cable, it can record the operating data of the controller or monitor the real-time operating status of the controller via PC software.

5. Operation

5.1 Button Functions

Controller Button Functions
Mode Note
Load ON/OFF In load manual mode, press the "ENTER" button to turn the load On/Off.
Clear Fault Press the "ENTER" button.
Browsing Mode Press the "SELECT" button.
Setting Mode Press the "ENTER" button and hold for 5s to enter the setting mode. Press the "SELECT" button to set parameters. Press the "ENTER" button to confirm parameters or exit setting mode automatically after 10s.

5.2 LCD Display Interface

The LCD provides real-time system status and parameters. The display includes various icons and numerical values.

Table of LCD icons and their meanings: PV array (Day, Night, No charging, Charging, PV Voltage/Current/Power), Battery (Battery capacity, In Charging, Battery Voltage/Current/Temperature, Battery Type), Load (Load ON, Load OFF, Load Voltage/Current/Load mode).
LCD Display Icons and their Status.
Sequence of LCD screens showing different browsing interfaces: PV voltage, current, kWh, load type, battery voltage, battery temperature.
Browse Interface Screens.

5.3 Settings

To enter setting mode, press and hold the "ENTER" button for 5 seconds.

  1. Clear Generated Energy:
    • Step 1: Press and hold the "ENTER" button for 5s under the PV power interface until the value flashes.
    • Step 2: Press the "ENTER" button again to clear the generated energy.
  2. Switch Battery Temperature Unit:
    • Press and hold the "ENTER" button for 5s under the battery temperature interface.
  3. Battery Type Selection:
    Sequence of LCD screens showing battery type selection: Sealed (Default), Gel, Flooded, User.
    Battery Type Selection Interface.

    CAUTION: When the default battery type is selected, the battery voltage control parameters will be set by default and cannot be changed. To change these parameters, select "User" battery type.

    • Step 1: Press the "ENTER" button and hold for 5s under the battery interface.
    • Step 2: Press the "SELECT" button when the battery type interface is flashing.
    • Step 3: Press the "ENTER" button to confirm the battery type.

    CAUTION: Please refer to the Battery Voltage Control Parameters table for user-defined battery control voltage settings.

Battery Voltage Control Parameters (12V system at 25°C)
Voltage Sealed Gel Flooded User
Over Voltage Disconnect Voltage16.0V16.0V16.0V9~17V
Charging Limit Voltage15.0V15.0V15.0V9~17V
Over Voltage Reconnect Voltage15.0V15.0V15.0V9~17V
Equalize Charging Voltage14.6V—14.8V9~17V
Boost Charging Voltage14.4V14.2V14.6V9~17V
Float Charging Voltage13.8V13.8V13.8V9~17V
Boost Reconnect Charging13.2V13.2V13.2V9~17V
Low Voltage Reconnect Voltage12.6V12.6V12.6V9~17V
Under Voltage Warning Reconnect Voltage12.2V12.2V12.2V9~17V
Under Voltage Warning Voltage12.0V12.0V12.0V9~17V
Low Voltage Disconnect Voltage11.1V11.1V11.1V9~17V
Discharging Limit Voltage10.6V10.6V10.6V9~17V
Equalize Duration120 min—120 min0~180 min
Boost Duration120 min120 min120 min10~180 min

Note: For 24V systems, double the values in the table.

6. Maintenance

Regular maintenance ensures optimal performance and longevity of your solar charge controller.

  • Cleanliness: Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
  • Connections: Periodically check all wiring connections for tightness and corrosion. Loose connections can cause overheating and poor performance.
  • Ventilation: Ensure that the ventilation openings are not blocked to allow proper heat dissipation.
  • Environmental Check: Verify that the operating environment remains within the specified temperature and humidity ranges.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your controller has the latest features and bug fixes.

7. Troubleshooting

The controller's LCD display provides fault indications to help diagnose issues.

Table of fault indications: Battery over discharged, Battery over voltage, Battery over temperature, Load failure (overload or short circuit). Includes icons and descriptions.
Fault Indications and Descriptions.

Common Troubleshooting Steps:

  • No Display/Power:
    • Check battery connections and voltage.
    • Ensure the battery is not completely discharged.
  • No Charging:
    • Verify solar panel connections and voltage.
    • Check for shading on solar panels.
    • Ensure battery voltage is within acceptable range for charging.
  • Load Not Working:
    • Check load connections and ensure the load is not overloaded or short-circuited.
    • Verify battery voltage is above the low voltage disconnect setting.
    • Check load work mode settings.
  • Overheating:
    • Ensure proper ventilation around the controller.
    • Reduce load or solar input if consistently overheating.

8. Specifications

8.1 Electrical Parameters

Electrical Parameters
Item Tracer 1206AN Tracer 2206AN Tracer 1210AN Tracer 2210AN Tracer 3210AN Tracer 4210AN
System nominal voltage12/24VDC Auto
Rated charge current10A20A10A20A30A40A
Rated discharge current10A20A10A20A30A40A
Battery voltage range8~32V
Max. PV open circuit voltage60V (46V)100V (92V)
MPP voltage range(Battery voltage +2V)~36V(Battery voltage +2V)~72V
Max. PV input power130W/12V, 260W/24V260W/12V, 520W/24V130W/12V, 260W/24V260W/12V, 520W/24V390W/12V, 780W/24V520W/12V, 1040W/24V
Self-consumption≤12mA
Discharge circuit voltage drop≤0.23V
Temperature compensate coefficient-3mV/°C/2V (Default)
GroundingCommon negative
RS485 interface5VDC/100mA
LCD backlight time60S (Default)

Notes:

  1. When a lead-acid battery is used, the controller hasn't the low temperature protection.
  2. At minimum operating environment temperature.
  3. At 25°C environment temperature.
  4. When a lithium-ion battery is used, the system voltage can't be identified automatically.

8.2 Environmental Parameters

Environmental Parameters
Item Value
Working environment temperature-25°C~+50°C (100% input and output)
Storage temperature range-20°C~+70°C
Relative humidity≤95%, N.C.
EnclosureIP30

8.3 Mechanical Parameters

Mechanical Parameters
Item Tracer1206AN / Tracer1210AN Tracer2206AN / Tracer2210AN Tracer3210AN Tracer4210AN
Dimension172x139 x 44mm220x154x 52mm228x164x55mm252x180x63mm
Mounting dimension130x130mm170x145mm170x164mm210x171mm
Mounting hole sizeΦ5mm
Terminal Recommended cable12AWG(4mm²)10AWG(6mm²)8AWG(10mm²)6AWG(16mm²)
Weight0.57kg0.94kg1.26kg1.65kg

8.4 Conversion Efficiency Curves

Graph showing 12V Conversion Efficiency Curves, with efficiency percentage on Y-axis and Charging Power W on X-axis. Curves for 17V and 34V are shown.
12V Conversion Efficiency Curves.
Graph showing 24V Conversion Efficiency Curves, with efficiency percentage on Y-axis and Charging Power W on X-axis. Curves for 34V, 51V, and 68V are shown.
24V Conversion Efficiency Curves.

9. Warranty and Support

For warranty information and technical support, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.

Typical warranty covers manufacturing defects under normal use. Damage due to improper installation, misuse, or environmental factors may not be covered.

10. User Tips

  • Optimal Panel Sizing: Ensure your solar panel array's voltage and power are within the controller's specified limits for maximum efficiency and to prevent damage.
  • Battery Compatibility: Always select the correct battery type in the controller settings (Sealed, Gel, Flooded, or User) to ensure proper charging algorithms and battery longevity.
  • Remote Monitoring: Utilize the optional WiFi or Bluetooth adapters with the mobile app for convenient remote monitoring of your system's performance and to adjust settings without direct access to the controller.
  • Cable Sizing: Use appropriately sized cables for all connections (PV, Battery, Load) to minimize voltage drop and ensure safe operation, especially for higher current models.
  • Environmental Protection: While the controller has an IP30 enclosure, consider installing it in a protected environment to shield it from direct weather exposure and extreme conditions, which can extend its lifespan.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.