1. Introduction and Overview

The EPEVER Tracer AN series MPPT Solar Charge Controller is an advanced, artistic, economical, and practical solution for solar power systems. Based on a common negative design and an advanced Maximum Power Point Tracking (MPPT) control algorithm, it features an LCD for displaying running status. This controller is designed to maximize energy harvest from solar modules under various conditions, offering a 10%-30% increase in energy utilization compared to traditional PWM charging methods.

Key features include ultra-fast tracking speed, accurate recognition of multiple-peak maximum power points, and robust protection mechanisms. It is compatible with both lead-acid and lithium-ion batteries and offers various load work modes, making it suitable for diverse applications.

EPEVER Tracer 10420AN MPPT Solar Charge Controller front view
Figure 1: EPEVER Tracer 10420AN MPPT Solar Charge Controller
Video 1: Overview of the EPEVER Tracer AN Series Solar Charge Controller.

2. Features

  • Advanced MPPT technology, with efficiency no less than 99.5%.
  • Ultra-fast tracking speed and guaranteed tracking efficiency.
  • Advanced MPPT control algorithm to minimize maximum power point loss rate and loss time.
  • Wide MPP operating voltage range.
  • High quality components, perfecting system performance, with maximum conversion efficiency of 98%.
  • Accurate recognition and tracking of multiple-peaks maximum power point.
  • Utilizes international famous brands of ST and IR's components for high quality and low failure rate, ensuring product longevity.
  • Charging power and current limitation function.
  • Compatible with lead-acid (Sealed/Gel/Flooded) and lithium-ion batteries (LiFePO4/Li(NiCoMn)O2).
  • Battery temperature compensation function.
  • Real-time energy statistics function.
  • Overheating power reduction function.
  • Multiple load work modes.
  • Communication port adopts professional protection chip, providing 5VDC power supply with over-current and short-circuit protection.
  • RS-485 communication bus interface and Modbus communication protocol for various communication requirements.
  • Monitor and set parameters via mobile phone APP or PC software.
  • Full-load operation without any drop in capacity within the range of working environment temperature.
  • Extensive electronic protection.

3. Specifications

The following table details the specifications for the Tracer AN series controllers, including the Tracer 10420AN model.

Parameter Tracer6415AN Tracer8420AN Tracer10415AN Tracer10420AN
Battery type Lead-acid (Sealed/Gel/Flooded)/Lithium (LiFePO4/Li(NiCoMn)O2)/User
Battery input voltage range 8V - 68V
Rated charge current 50A 60A 80A 100A
Rated charge power 625W/12V, 1250W/24V, 1875W/36V, 2500W/48V 750W/12V, 1500W/24V, 2250W/36V, 3000W/48V 1000W/12V, 2000W/24V, 3000W/36V, 4000W/48V 1250W/12V, 2500W/24V, 3750W/36V, 5000W/48V
Max. conversion efficiency 98.30% 98.60% 98.50% 98.50%
Tracking efficiency ≥99.5%
Max. PV open circuit voltage 150V (At minimum operating environment temperature), 138V (At 25°C environment temperature) 200V (At minimum operating environment temperature), 180V (At 25°C environment temperature)
MPP voltage range (Battery Voltage +2V) ~ 108V (Battery Voltage +2V) ~ 144V
Equalization voltage Sealed:14.6V, Flooded:14.8V, User-defined:9-17V
Boost voltage Gel:14.2V, Sealed:14.4V, Flooded:14.6V, User-defined:9-17V
Float voltage Gel/Sealed/Flooded:13.8V, User-defined:9-17V
Low voltage reconnect voltage Gel/Sealed/Flooded:12.6V, User-defined:9-17V
Self-consumption 98mA/12V, 66mA/24V, 50mA/36V, 46mA/48V
Temperature compensation (for lead-acid battery) -3mV/°C/2V (Default)
Relative humidity 5% to 95% (N.C.)
Enclosure IP20
Communication interface RS485 (5VDC/200mA, Two RJ45 ports in parallel)
Grounding Common negative
Operating temperature range -25°C ~ +60°C (derating above 45°C)
Dimension (LxWxH)mm 261×216×119 340×236×119 394×242×143
Net weight 4.5kg 5.7kg 8kg 9.1kg

Notes: 1. The controller cannot automatically identify system voltage if lithium batteries are connected. 2. The voltage point is for 12V system; multiply by 2 for 24V, 3 for 36V, and 4 for 48V systems.

Detailed specifications table for EPEVER Tracer AN series solar charge controllers
Figure 2: Detailed Specifications Table.

4. Safety Information

  • Read all instructions carefully before installation and operation.
  • Ensure all wiring is correctly polarized and securely connected to prevent damage to the controller or other components.
  • Always disconnect power from the solar array and battery before installing or adjusting the controller.
  • Use appropriate circuit breakers or fuses for all connections to protect against overcurrent.
  • Install the controller in a well-ventilated area, away from flammable materials and direct sunlight.
  • Do not disassemble or attempt to repair the controller yourself. Refer to qualified personnel for service.
  • Keep children away from the solar power system components.

5. Installation and Setup

Proper installation is crucial for the safe and efficient operation of your solar charge controller. Follow these steps carefully:

  1. Mounting: Choose a suitable location for mounting the controller. Ensure adequate ventilation and protection from moisture and direct sunlight. Use the mounting holes provided on the controller.
  2. Wiring Sequence: Connect the components in the following order to ensure safety and proper function:
    • Connect the battery to the controller's battery terminals.
    • Connect the solar panel array to the controller's PV terminals.
    • Connect the load to the controller's load terminals (if applicable).
    • Connect the grounding terminal to earth ground.
  3. Terminal Connections: Ensure all wire connections are tight and secure. Refer to the connection diagram for correct terminal identification.
  4. Optional Accessories: If using optional accessories such as a remote temperature sensor (RTS), MT50 remote meter, EBOX-WiFi, or RS485 cable for PC connection, connect them to the designated ports.
Detailed connection diagram for the EPEVER MPPT solar charge controller, showing connections to PV, battery, load, and optional accessories.
Figure 3: Connection Diagram. Note: Actual wiring may vary; consult local electrical codes.
Close-up view of the EPEVER solar charge controller terminals, including battery, PV, load, fuse, and communication ports.
Figure 4: Controller Terminal Layout. Labels: 1. Fuse, 2. Battery Terminals, 3. PV Terminals, 4. Load control relay, 5. RBVS Port, 6. Utility/Generator relay ON, 7. Utility/Generator relay OFF, 8. RS485 port (5VDC/200mA), 9. RTS Port, 10. Generator and load relay enable, 11. PV reverse polarity alarm indicator, 12. Grounding Terminal, 13. SELECT button, 14. Charging LED indicator, 15. Fault LED indicator, 16. ENTER button.

6. Operation

The controller features an intuitive LCD display and two buttons for navigation and settings.

  1. LCD Display: The back-light LCD displays various system parameters such as PV working status, charging current, battery voltage, load work mode, generated energy, and temperature.
  2. Buttons:
    • SELECT button: Used to browse through different display screens and navigate menu options.
    • ENTER button: Used to confirm selections, enter settings, and control the load relay (on/off).
  3. Setting Parameters: Through the menu, you can set various parameters including battery type, clear generated energy statistics, and switch the battery temperature unit.
  4. Load Control: The load output can be controlled manually or automatically based on programmed settings.
Diagram showing the LCD display and button functions for browsing and setting parameters on the EPEVER solar charge controller.
Figure 5: Display and Operation Flow. Shows how to navigate through screens and adjust settings.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your solar charge controller:

  • Cleanliness: Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
  • Connections: Periodically check all wiring connections for tightness and corrosion. Loose connections can lead to power loss or overheating.
  • Ventilation: Ensure that the ventilation openings are not blocked to allow for proper heat dissipation.
  • Battery Health: Monitor battery voltage and health regularly, especially for lead-acid batteries, to ensure they are being charged correctly.
  • Firmware Updates: Check the EPEVER website for any available firmware updates to ensure your controller has the latest features and bug fixes.

8. Troubleshooting

If you encounter issues with your controller, refer to the following common troubleshooting steps:

  • No Display/Power:
    • Check battery connections and ensure the battery voltage is within the operating range.
    • Verify the fuse is intact and not blown.
  • No Charging:
    • Ensure solar panels are connected correctly and receiving sufficient sunlight.
    • Check PV input voltage and current.
    • Verify that the battery type settings are correct for your battery.
  • Load Not Working:
    • Check load connections and ensure the load is not drawing excessive current.
    • Verify the load control settings on the controller.
    • Check for low battery voltage disconnect.
  • Error Codes/Fault Indicators: Refer to the controller's LCD display for any fault codes. Consult the full EPEVER manual (if available) for specific error code interpretations.

9. User Tips

  • System Sizing: Always ensure your solar panel array and battery bank are appropriately sized for your controller's specifications to prevent overloading or underperformance.
  • Battery Type Setting: Double-check the battery type setting in the controller's menu to match your specific battery chemistry (e.g., Sealed, Gel, Flooded, LiFePO4). Incorrect settings can damage your batteries.
  • Remote Monitoring: Utilize the RS485 communication port with an EBOX-WiFi or PC software for remote monitoring and advanced parameter configuration. This allows for better system management and troubleshooting.
  • Temperature Sensor: For optimal battery charging, especially with lead-acid batteries, ensure the remote temperature sensor (RTS) is properly installed and connected to the battery.

10. Warranty and Support

For warranty information, technical support, or service inquiries regarding your EPEVER Tracer AN series solar charge controller, please contact your original point of purchase or visit the official EPEVER website. When contacting support, please have your model number (Tracer 10420AN) and serial number readily available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.