FNIRSI FAM-02

FNIRSI FAM-02 High Precision Anemometer User Manual

Model: FAM-02

1. Introduction

The FNIRSI FAM-02 is a professional-grade, high-precision handheld instrument designed for comprehensive environmental monitoring. It accurately measures wind speed, ambient temperature, and relative humidity. Featuring a robust eight-blade wind wheel for quick response, a clear display with dual themes, five types of unit switching, and a triple alarm system (sound, light, and vibration), the FAM-02 is suitable for various applications requiring precise environmental data.

FNIRSI FAM-02 Anemometer with key features listed
Figure 1: FNIRSI FAM-02 Anemometer highlighting its features: Curve recording, Dual theme display, Five types of unit switching, and Triple alarm.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present and in good condition:

  • FNIRSI FAM-02 Anemometer Unit
  • User Manual
  • Charging Cable (if applicable)
  • Protective Case (if included)

3. Setup

3.1 Battery Installation and Charging

The FAM-02 comes with a built-in battery. Before first use, ensure the device is fully charged using the provided charging cable. Connect the cable to the device's charging port and a suitable USB power source. The charging indicator on the device will show its status.

3.2 Initial Power On

Press and hold the power button (usually located on the side or front panel) for a few seconds until the display illuminates. The device will perform a self-test and then enter the default measurement mode.

Full view of the FNIRSI FAM-02 handheld anemometer
Figure 2: Full view of the FAM-02 Anemometer, showing its compact design and controls.

3.3 Basic Settings

Upon initial power-on or after a factory reset, you may need to configure basic settings:

  • **Unit Switching**: Navigate through the settings menu to select your preferred units for wind speed (e.g., m/s, km/h, mph, knots, ft/min), temperature (°C/°F), and humidity (%). The device supports five types of unit switching for wind speed.
  • **Theme Display**: The device offers a dual theme display. Access the display settings to switch between available themes for optimal readability in different lighting conditions.
  • **Alarm Thresholds**: Set the desired wind speed threshold for the triple alarm function.

4. Operating Instructions

4.1 Power On/Off

  • **Power On**: Press and hold the power button until the screen turns on.
  • **Power Off**: Press and hold the power button until the screen turns off, or allow the device to auto-power off after a period of inactivity (configurable in settings).

4.2 Taking Measurements

Hold the device upright, ensuring the wind wheel is exposed to the airflow you wish to measure. The device will simultaneously display wind speed, temperature, and humidity on the screen.

Display showing simultaneous wind speed, temperature, and humidity readings
Figure 3: The FAM-02 display showing simultaneous readings for wind speed, temperature, and humidity.

4.3 Curve Recording Mode

The FAM-02 features a curve recording mode to visualize wind speed changes over a period of time. To activate this mode, navigate to the 'Curve Recording' option in the menu. The display will show a graphical representation of the wind speed data, making trends more intuitive to observe.

Curve recording mode display, illustrating historical wind speed data
Figure 4: The curve recording mode provides a visual history of wind speed changes.

4.4 Strong Wind Warning

When the measured wind speed reaches or exceeds the preset threshold, the device will activate its triple alarm system, providing alerts through sound, light, and vibration. This feature is crucial for safety and timely awareness in high-wind conditions.

Anemometer displaying a strong wind warning with visual alarm
Figure 5: The device indicating a strong wind warning with a visual alert.

5. Maintenance

5.1 Cleaning

  • Regularly clean the exterior of the device with a soft, dry cloth.
  • For the wind wheel, use a soft brush or compressed air to gently remove any dust or debris that might impede its rotation. Avoid using liquids or harsh chemicals.
Close-up of the eight-blade wind wheel for precise sensing
Figure 6: Close-up of the eight-blade wind wheel, emphasizing the need for clear rotation.

5.2 Storage

When not in use, store the FAM-02 in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.

5.3 Battery Care

Avoid fully discharging the battery frequently. Recharge the device when the battery level is low to maintain optimal battery health.

6. Troubleshooting

  • **Device not powering on**: Ensure the battery is charged. If the issue persists, try connecting to a different charging source.
  • **Inaccurate readings**: Check if the wind wheel is obstructed or dirty. Ensure the device is held correctly in the airflow.
  • **Alarm not triggering**: Verify that the alarm threshold is set correctly in the device settings.
  • **Display issues**: Try restarting the device. If the problem continues, ensure the device is not exposed to extreme temperatures.

7. Specifications

FeatureDescription
BrandFNIRSI
Model NumberFAM-02
TypeAnemometer
MeasurementsWind Speed, Temperature, Humidity
Wind WheelEight-blade, Quick Response
DisplayDual Theme Display
Unit SwitchingFive types for Wind Speed
Alarm SystemTriple (Sound, Light, Vibration)
Battery IncludedYes
OriginMainland China
Package Dimensions10cm (Length) x 10cm (Width) x 10cm (Height)
Package Weight0.34 kg

8. User Tips

  • For the most accurate wind speed readings, ensure the device is held in an open area, free from obstructions that could create turbulence.
  • When using the curve recording mode, allow sufficient time for data collection to observe meaningful trends.
  • Regularly check and clean the wind wheel to prevent debris from affecting measurement accuracy.
  • Keep the device away from strong electromagnetic fields, which could interfere with its sensors.

9. Warranty and Support

The FNIRSI FAM-02 is a Certified Original product. For any manufacturing defects or issues arising from normal use, please refer to the manufacturer's warranty policy. The product is typically covered by a standard manufacturer's warranty. For support, please contact the retailer or manufacturer directly. Free returns are available within 90 days of purchase, subject to the retailer's terms and conditions.

Related Documents - FAM-02

Preview FNIRSI FAM-02 Digitální Anemometr: Uživatelská Příručka
Podrobná uživatelská příručka pro digitální anemometr FNIRSI FAM-02. Zjistěte, jak používat tento 3v1 měřič rychlosti větru, teploty a vlhkosti s barevným displejem.
Preview FNIRSI 2C23T 双通道示波器万用表手册
FNIRSI 2C23T 是一款集示波器、万用表和信号发生器于一体的三合一便携式数字测试仪器。它拥有 50MS/s 采样率、10MHz 带宽、高达 ±400V 的电压测量能力,以及 2.8 英寸高清显示屏和 3000mAh 电池,提供全面的测试解决方案。
Preview FNIRSI FDM-02 Color Screen Digital Sound Level Meter User Manual
User manual for the FNIRSI FDM-02 Color Screen Digital Sound Level Meter, providing detailed information on its features, operation, technical specifications, maintenance, troubleshooting, and warranty.
Preview FNIRSI IR40 Smart Rangefinder User Manual
Comprehensive user manual for the FNIRSI IR40 Smart Rangefinder, detailing its features, measurement modes, specifications, connectivity, and safety guidelines for accurate distance measurement.
Preview FNIRSI USB Meter Tool Manual (V0.2) - User Guide
Comprehensive manual for the FNIRSI USB Meter Tool (V0.2), covering connection, data recording, protocol triggering (QC2.0, QC3.0, Huawei FCP/SCP, Samsung AFC), system functions, alarms, and troubleshooting.
Preview FNIRSI DSO153 Digital Oscilloscope: Instruction Manual & Specifications
Comprehensive instruction manual for the FNIRSI DSO153 handheld digital oscilloscope. Learn about its features, panel layout, button functions, technical parameters, screen indications, firmware updates, and contact information.