EPEVER DR2106N-DDS

Contents

EPEVER MPPT Dual Battery Solar Charge Controller

Model: DR2106N-DDS

User Manual

1. Introduction

The EPEVER DuoRacer series MPPT Dual Battery Solar Charge Controller is designed for off-grid photovoltaic systems in recreational vehicles (RVs), yachts, and similar applications. Utilizing advanced MPPT (Maximum Power Point Tracking) technology, this controller efficiently charges two independent batteries simultaneously: a main battery (BATT1) and a starting battery (BATT2).

The controller supports various battery types for the main battery, including lithium batteries, and employs a trickle charging mode for the starting battery to prolong its lifespan. It also features a built-in AES (Automatic Energy Saving) control signal for car refrigerators, optimizing photovoltaic energy utilization. Comprehensive electronic protection ensures safe, stable, and long-term operation of your solar power system.

2. Key Features

  • MPPT tracking efficiency of not less than 99.5%.
  • Wide maximum power point operating voltage range to enhance photovoltaic module utilization.
  • Automatic limit function for rated charging power and charging current (BATT1).
  • Adaptive three-stage charging mode, controlled by digital circuit (BATT1).
  • BATT2 uses trickle charging mode to extend battery life.
  • Locally configurable battery types for BATT1.
  • Compatible with lead-acid and lithium batteries (BATT1).
  • Low power consumption operating mode.
  • Full load operation within the operating ambient temperature range without derating.
  • Optional LED and LCD display operation modules.
  • Car refrigerator control signal with AES for optimal photovoltaic energy use.
  • Standard Modbus communication protocol based on RS485 communication bus.

3. Product Overview

The following diagram illustrates the main components and ports of the DR2106N-DDS controller:

Labeled diagram of EPEVER MPPT Dual Battery Solar Charge Controller ports
Figure 3.1: Controller Components and Ports
1 - Mounting hole size Ø5mm
2 - LCD (Refer to chapter 3 for details)
3 - Grounding Terminal
4 - Remote temperature sensor (RTS) port
5 - PV terminals
6 - BATT1 terminals (Main battery)
7 - BATT2 terminals (Start battery)
8 - RS485 Communication port (2)
9 - AES (signal) output port (2)
10 - Terminal protection cover

Watch this video for an unboxing and visual overview of the EPEVER MPPT Dual Battery Solar Charge Controller:

Video 3.2: EPEVER MPPT Solar Charge Controller Unboxing and Overview

4. Specifications

The following table details the technical specifications for the DuoRacer series, with the DR2106N-DDS model highlighted:

ParameterDR1106N-DDSDR2106N-DDSDR3106N-DDS
BATT1 rated voltage12VDC12VDC12VDC
BATT2 rated voltage12VDC12VDC12VDC
BATT1 rated charge current10A20A30A
BATT2 rated charge current1A1A1A
Battery input voltage range8.5V~16V8.5V~16V8.5V~16V
Max. PV open circuit voltage60V (at minimum operating environment temperature); 46V (at 25℃ environment temperature)
MPP voltage range(Battery Voltage+2V) ~ 36V
Rated charge power130W/12V260W/12V390W/12V
Max. conversion efficiency96.3%96.9%97.4%
Full load efficiency95.5%94.6%94.2%
Self-consumption12mA/12V; 6mA/12V; (Low-power mode)
Temperature compensation-3mV/℃/2V (default)
GroundingCommon negative
BATT2 full voltage13.8V/12V13.8V/12V13.8V/12V
BATT2 charge return voltage13V/12V13V/12V13V/12V
Operating Temp. range-20℃~+50℃ (DDS); -30℃~+50℃ (DDB)
EnclosureIP33
Dimensions (L*W*H)mm227.2×143×58243.7×158×63247.2×165×68.5
Net weight0.8KG1.1KG1.4KG

5. Installation and Wiring

Proper installation is crucial for the safe and efficient operation of your solar charge controller. Please follow these guidelines carefully.

5.1 System Overview

The DuoRacer controller is designed to integrate seamlessly into RV and marine solar systems, charging both your main service battery and your engine start battery.

Diagram showing EPEVER MPPT Dual Battery Solar Charge Controller installed in an RV
Figure 5.1: Typical RV/Camper Installation Diagram
This diagram illustrates the controller connecting to the PV array, Main Battery (BAT1), Start Battery (BAT2), and an optional MT11 remote meter.

5.2 Wiring Diagram

Follow the wiring diagram below for correct connections. Ensure all connections are secure and properly insulated.

Detailed wiring diagram for EPEVER MPPT Dual Battery Solar Charge Controller
Figure 5.2: Detailed Wiring Diagram
This diagram shows the connections for the PV array (3), Main Battery (2), Start Battery (1), and optional accessories like the Remote Temperature Sensor (RTS) and AES-ADP for a refrigerator. Ensure appropriate fuses and breakers are installed as shown.
  1. Connect the Start Battery (BATT2): Connect the positive and negative terminals of the start battery to the BATT2 terminals on the controller.
  2. Connect the Main Battery (BATT1): Connect the positive and negative terminals of the main battery to the BATT1 terminals on the controller.
  3. Connect the PV Array: Connect the positive and negative leads from your solar panel(s) to the PV terminals on the controller. Ensure correct polarity.
  4. Connect Grounding Terminal: Connect the grounding terminal (3) to earth ground.
  5. Connect Remote Temperature Sensor (RTS): If using, connect the RTS (4) to the designated port to ensure accurate temperature compensation for battery charging.
  6. Connect AES (signal) output port: If using a car refrigerator with AES functionality, connect it to the AES output port (9).
  7. Connect RS485 Communication port: For external communication or monitoring devices (e.g., MT11 remote meter), connect to the RS485 ports (8).
  8. Secure Terminal Protection Cover: Once all wiring is complete and verified, install the terminal protection cover (10).

Important Safety Note: Always connect batteries to the controller BEFORE connecting the solar panels. Disconnect in the reverse order (PV first, then batteries).

6. Operating Instructions

The controller features an LCD display and buttons for monitoring and configuration. Refer to the product overview (Figure 3.1) for button locations.

6.1 Display Information

The LCD displays real-time system status, including battery voltage, charging current, PV voltage, and error codes. Use the 'MENU' and 'DOWN/SET' buttons to navigate through different display screens.

6.2 Parameter Settings

To adjust parameters such as battery type for BATT1 or other charging settings:

  1. Press and hold the 'DOWN/SET' button to enter the parameter setting mode.
  2. Use the 'MENU' button to cycle through available parameters.
  3. Use the 'DOWN/SET' button to change the value of the selected parameter.
  4. Press and hold the 'MENU' button to save changes and exit the setting mode.

Consult the detailed manual (if available) for specific parameter definitions and recommended values for your battery type.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your solar charge controller.

  • Cleanliness: Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
  • Connections: Periodically check all wiring connections for tightness and corrosion. Loose connections can cause overheating and damage.
  • Ventilation: Ensure adequate airflow around the controller's heat sink to prevent overheating. Do not block ventilation openings.
  • Battery Inspection: Regularly inspect your batteries for any signs of damage, swelling, or leaks. Ensure battery terminals are clean.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your controller has the latest features and bug fixes.

8. Troubleshooting

This section provides solutions to common issues you might encounter.

ProblemPossible CauseSolution
No display on LCDNo power from battery or PV; loose connection.Check battery and PV connections. Ensure battery voltage is within operating range.
BATT1 not chargingPV array not connected or insufficient sunlight; faulty PV module; incorrect battery type setting.Verify PV connections and sunlight. Test PV module voltage. Check BATT1 battery type setting.
BATT2 not chargingBATT2 not connected; BATT1 is not charging or is full.Check BATT2 connections. BATT2 only trickle charges when BATT1 is charging or full.
OverheatingPoor ventilation; excessive load.Ensure adequate airflow around the controller. Reduce load if possible.
Error code displayedSystem fault (e.g., over-voltage, short circuit).Refer to the full product manual for specific error code meanings and solutions. Disconnect and reconnect power to reset.

9. User Tips

  • For optimal performance, ensure your solar panels are clean and free from obstructions.
  • Consider installing a remote meter (like the MT11) for easier monitoring of your system's performance from inside your RV or boat.
  • When selecting battery types, always match the controller's settings to your actual battery chemistry (e.g., Lead-Acid, Lithium) for BATT1 to prevent damage and ensure efficient charging.
  • Periodically check the temperature sensor connection if you are using one, as it's vital for accurate temperature compensation.

10. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.