1. Introduction
The IPower Plus series is a new line of pure sine wave inverters designed for compatibility with lithium battery systems. These inverters feature advanced input surge current suppression technology, which effectively protects lithium battery cells and their Battery Management Systems (BMS) from surge current damage. Utilizing a smart voltage and current double closed-loop control algorithm, the inverter offers faster response times and enhanced resistance to load impacts. The internal design incorporates high-quality, high-power-density components to ensure stable, reliable, and sufficient power output for extended use. Optional communication solutions allow users to monitor operational status in real-time and configure parameters remotely.
This equipment is suitable for various applications requiring DC to AC conversion, including solar AC power systems, vehicle systems, RV power supplies, security monitoring systems, emergency lighting systems, field power systems, and household power systems. With its EMC (Electro Magnetic Compatibility) characteristics, the inverter is also ideal for environments demanding higher power quality.
2. Features
- Completely isolated input and output design.
- Smart voltage and current double closed-loop control for faster response and improved reliability.
- EMC characteristics suitable for high-quality power systems.
- Advanced SPWM technology and pure sine wave output.
- Input surge current suppression technology, supporting lithium battery systems.
- High resistance to impact loads (e.g., air conditioners, washing machines, refrigerators).
- High power density and high-quality components for reliability.
- Output power factor up to 1.
- Low no-load and standby loss.
- Low THD (Total Harmonic Distortion).
- High conversion efficiency.
- Extensive protection features: input reverse polarity, input overvoltage, input low voltage, output overload, short circuit, and overheating.
- Air cooling controlled by dual conditions (temperature and load).
- 180-degree rotatable LCD design for simplified system wiring.
- One-click control of operational status.
- User-friendly LCD design for easy monitoring and parameter configuration.
- Supports phone Apps and PC software for remote control.
- Output voltage 220/230VAC and frequency 50/60Hz optional.
- USB ports (5VDC/Max.1A) for powering DC fans and charging electronic equipment.
- External switch contact design for remote control.
- IEC62109, EN61000, RoHS approved.
- Parameters can be monitored via inverter LCD, remote LCD, phone Apps, and PC software.
- Note: USB function is unavailable for 48V input inverters.
3. Product Overview
3.1 Inverter Components
3.2 LCD Display and Buttons
| No. | Component | Function/Indicator |
|---|---|---|
| 1 | LCD | Displays system information and parameters. |
| 2 | UP/Setting button | Navigates up or enters settings. |
| 3 | Fault indicator (red) | Indicates system faults. |
| 4 | Working status indicator (Blue) | Indicates operational status (solid blue for ON, slow flashing for 1/4Hz, fast flashing for 1Hz, OFF for no power). |
| 5 | DOWN/Enter button | Navigates down or confirms selection. |
| 6 | Output ON/OFF button | Controls the inverter's AC output. |
| 6 | Screws of the LCD | Secures the LCD panel. |
4. Setup Instructions
Before installation, ensure the inverter is placed in a well-ventilated area, away from direct sunlight, high temperatures, and moisture. Always disconnect power sources before making any connections.
4.1 General Connection Diagram
- Battery Connection: Connect the battery to the DC INPUT terminals on the inverter. Ensure correct polarity: red cable to the positive (+) terminal and black cable to the negative (-) terminal.
- AC Output Connection: Connect your domestic appliances to the AC OUTPUT terminals of the inverter.
- Verify Connections: Double-check all connections for tightness and correct polarity before proceeding.
4.2 Detailed Connection Diagrams by Model
Refer to the specific diagram for your inverter model to ensure correct wiring of all ports.
5. Operating Instructions
5.1 Powering On/Off
- After all connections are securely made, press the Output ON/OFF button (No. 6 in Figure 3.5) to turn on the inverter.
- The blue Working Status Indicator (No. 4 in Figure 3.5) will illuminate, and the LCD will display operational data.
- To power off, press the Output ON/OFF button again.
5.2 LCD Display Navigation
The LCD provides real-time monitoring of various parameters. Use the UP/Setting (No. 2) and DOWN/Enter (No. 5) buttons to navigate through the display interfaces.
The display typically cycles through the following information:
- Battery voltage
- Output voltage
- Output current
- Output power
- Output frequency
5.3 Rotating the LCD Display
The LCD display can be rotated 180 degrees to simplify system wiring and viewing, especially when the inverter is mounted in different orientations.
6. Maintenance
- Regular Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are not obstructed.
- Connection Checks: Periodically inspect all electrical connections (battery, AC output) to ensure they are tight and free from corrosion.
- Environmental Conditions: Ensure the inverter operates within its specified temperature and humidity ranges. Avoid exposure to water or excessive moisture.
- Battery Health: Monitor your battery's health and charge level, as a healthy battery is crucial for inverter performance.
7. Troubleshooting
- No Output Power: Check battery connections, battery voltage, and ensure the inverter is turned on. Verify that the load does not exceed the inverter's capacity.
- Fault Indicator On: Refer to the inverter's specific fault codes (if available in the full manual) or disconnect all loads and restart the inverter. If the fault persists, contact support.
- Overload Protection: If the inverter shuts down due to overload, reduce the connected load and restart the inverter.
- Overheating: Ensure adequate ventilation around the inverter. Clear any obstructions from the cooling fans.
8. Specifications
| Parameter | IP1000-Plus Series | IP1500-Plus Series | IP2000-Plus Series | IP3000-Plus Series | IP4000-Plus Series |
|---|---|---|---|---|---|
| Continuous Output Power | 1000W@35℃ | 1500W@35℃ | 2000W@35℃ | 3000W@35℃ | 4000W@35℃ |
| Surge Power | 2000W@5S | 3000W@5S | 4000W@5S | 6000W@5S | 8000W@5S |
| Surge Current (Power On) | <100A | <100A | <100A (1x/2x), <50A (4x) | <100A (1x/2x), <65A (4x) | <65A |
| Output Voltage | 110VAC(±3%); 120VAC(-7%~+3%) or 220VAC(±3%); 230VAC(-7%~+3%) | 220VAC(±3%); 230VAC(-7%~+3%) | |||
| Output Frequency | 50/60Hz±0.2% | ||||
| Output Wave | Pure Sine Wave | ||||
| Output Distortion THD | ≤4% (Resistive load) | ≤4% (Resistive load) | ≤3% (Resistive load) | ≤3% (Resistive load) | ≤3% (Resistive load) |
| Load Power Factor | 0.2~1 (Load power ≤ Continuous output power) | ||||
| Rated Input Voltage | 12V/24VDC | 12V/24V/48VDC | 12V/24V/48VDC | 12V/24V/48VDC | 48VDC |
| Input Voltage Range | 10.8~16.0VDC / 21.6~32.0VDC | 10.8~16.0VDC / 21.6~32.0VDC / 43.2~64.0VDC | 10.8~16.0VDC / 21.6~32.0VDC / 43.2~64.0VDC | 10.8~16.0VDC / 21.6~32.0VDC / 43.2~64.0VDC | 43.2~64.0VDC |
| Rated Output Efficiency | >87% (11-Plus), >89% (12-Plus) | >88% (11-Plus), >89% (12-Plus) | >85% (11-Plus), >91% (12-Plus) | >87% (11-Plus), >90% (12-Plus) | >91% |
| Max. Output Efficiency (30% loads) | >92% (11-Plus), >93% (12-Plus) | >93% (11-Plus), >93% (12-Plus) | >92% (11-Plus), >93% (12-Plus) | >94% (11-Plus), >94% (12-Plus) | >94% |
| Idle Current | <0.2A | <0.2A | <0.2A | <0.2A | <0.6A |
| No-load Current | <0.8A (11-Plus), <1.1A (12-Plus) | <1.0A (11-Plus), <1.2A (12-Plus) | <0.9A (11-Plus), <1.0A (12-Plus) | <1.6A (11-Plus), <1.0A (12-Plus) | <0.6A |
| USB Output | 5VDC/Max.1A (Unavailable for 48V input inverters) | ||||
| RS485 Com. Port | 5VDC/200mA | ||||
| Input Terminal | M6 (IP1000/1500/2000), M10 (IP3000) | ||||
| Dimension (L×W×H) | 371×231.5×123mm | 387×231.5×123mm | 421×231.5×123mm | 550×274×148mm (11-Plus), 521×274×148mm (12-Plus) | 516×231.5×123mm |
| Mounting Dimension | 345×145mm | 361×145mm | 395×145mm | 525×145mm (11-Plus), 495×145mm (12-Plus) | 490×145mm |
| Mounting Hole Size | Φ6mm | ||||
| Net Weight | 5.8kg | 6kg | 6.5kg | 13kg (11-Plus), 8kg (12-Plus) | 8kg |
| Operating Temperature Range | -20℃~+60℃ (Refer to the derating curve) | ||||
| Relative Humidity | < 95% (N.C.) | ||||
| Enclosure | IP20 | ||||
9. User Tips
- Ventilation is Key: Always ensure your inverter has ample space for airflow. Proper ventilation prevents overheating and prolongs the life of the unit.
- Match Load to Inverter: Do not exceed the continuous output power of your inverter. For appliances with high startup surges (like refrigerators or pumps), ensure the inverter's surge power capacity can handle it.
- Battery Compatibility: Confirm your battery type (e.g., Lead-acid, Lithium) and voltage (12V, 24V, 48V) are compatible with your specific inverter model.
- Cable Sizing: Use appropriately sized cables for battery connections to minimize voltage drop and ensure efficient power transfer.
- Remote Monitoring: Utilize the available phone Apps or PC software for remote monitoring and parameter configuration, especially for systems in hard-to-reach locations.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official Epever website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.