1. Introduction
The Epever UPower-Hi series is an advanced inverter/charger designed for diversified energy management in solar, utility, and generator hybrid systems. It integrates utility/generator, solar, and battery charging, along with utility bypass and inverter output to AC loads. This system allows users to prioritize energy sources based on their needs, using utility power as a supplement to maximize solar energy utilization. The UPower-Hi inverter/charger is engineered to deliver high-quality, stable, and reliable electrical energy for various off-grid applications.

2. Safety Instructions
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- Installation must be performed by qualified personnel.
- Ensure all power sources (solar, utility, battery) are disconnected before installation or maintenance.
- Use appropriate personal protective equipment (PPE) including insulated gloves and eye protection.
- Do not operate the inverter if it is damaged or appears to be malfunctioning.
- Ensure proper grounding of the inverter.
- Keep the inverter away from flammable materials, moisture, and direct sunlight.
- Ensure adequate ventilation around the inverter to prevent overheating.
- The inverter is designed for indoor use (IP30 enclosure).
3. Product Components
The UPower-Hi series inverter/charger consists of the main unit and several key interfaces:
- Main Inverter/Charger Unit: Houses the power conversion electronics, MPPT charge controller, and battery charger.
- 4.2-inch LCD Display: Provides real-time monitoring of system parameters and allows for configuration adjustments.
- Input/Output Terminals: Connections for AC utility input, AC load output, DC solar panel input, and battery bank.
- Communication Ports: Includes an RS485 isolated communication port for optional WiFi or GPRS remote control, and a BMS-Link port for lithium battery communication.



4. Setup and Installation
4.1 Physical Installation
The inverter should be mounted in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for proper airflow. Refer to the installation dimension drawing for precise mounting requirements.

4.2 Electrical Connections
All electrical connections must comply with local and national electrical codes. Use appropriately sized cables and circuit breakers for all connections. Ensure all connections are tight and secure.

- Battery Connection: Connect the battery bank to the DC input terminals. Ensure correct polarity. The inverter supports 24VDC or 48VDC battery systems depending on the model. Equipped with battery-side surge protection and reverse protection.
- Solar Panel Connection: Connect the solar panels to the PV input terminals. Observe maximum PV open circuit voltage and MPPT voltage range as specified in the technical data.
- AC Utility Input: Connect the AC utility grid to the AC input terminals. An AC breaker should be installed between the utility and the inverter.
- AC Load Output: Connect your AC loads to the AC output terminals. An AC breaker should be installed between the inverter and the loads.
- Grounding: Ensure the inverter is properly grounded to prevent electrical hazards.
4.3 Communication Connections
- RS485 Port: For optional WiFi or GPRS remote control modules.
- BMS-Link Port: For communication with compatible Lithium Battery Management Systems (BMS) for charge and discharge control.
5. Operating Instructions
5.1 Powering On/Off
- To Power On: Ensure all connections are secure. First, connect the battery, then the solar panels, and finally the AC utility (if used). The inverter will initiate its startup sequence.
- To Power Off: Disconnect the AC utility, then the solar panels, and finally the battery.
5.2 LCD Display and Control
The 4.2-inch LCD display provides a rich user interface for monitoring system status and configuring parameters. Use the ESC, UP, DOWN, and SET/ENTER buttons to navigate menus and adjust settings.
5.3 Operating Modes
The UPower-Hi series offers flexible operating modes:
- Charging Modes:
- Solar Only: Prioritizes solar power for battery charging.
- Solar Priority: Uses solar power primarily, supplementing with utility power if solar is insufficient.
- Utility & Solar: Uses both utility and solar power for charging.
- AC Output Modes:
- Utility Priority: AC loads are primarily powered by the utility grid, with the inverter providing backup from batteries/solar if the grid is unavailable.
- Inverter Priority: AC loads are primarily powered by the inverter (from batteries/solar), with the utility grid used as a backup.
5.4 Configurable Parameters
Users can configure various parameters via the LCD display or remote communication, including:
- Battery charging current.
- Battery discharging current.
- Grid charging current.
- Battery type (e.g., AGM, Gel, Flooded, Lithium).
- Self-learning SOC function for optimized battery management.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris.
- Connection Checks: Annually inspect all electrical connections (battery, solar, AC input/output) for tightness and corrosion. Re-tighten if necessary.
- Environmental Check: Ensure the operating environment remains within specified temperature and humidity ranges.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to improve performance or add features.
7. Troubleshooting
If you encounter issues, refer to the following basic troubleshooting steps. For complex problems, contact technical support.
- No Power/Display Off: Check battery connections and voltage. Ensure AC input and solar input are connected and active.
- No AC Output: Check AC output breaker. Verify inverter is in an active output mode (Utility Priority or Inverter Priority). Check for overload conditions.
- Battery Not Charging: Check solar panel connections and voltage. Verify utility input is present if using utility charging. Check charging mode settings.
- Error Codes: The LCD display will show specific error codes. Consult the full user manual (PDF) for a detailed list of error codes and their remedies.
- Overload Protection: If an overload occurs, the inverter may shut down. Reduce the load and restart the inverter.
8. Technical Specifications
| Item | UP2000-HM6022 | UP3000-HM10022 | UP3000-HM5042 | UP5000-HM8042 |
|---|---|---|---|---|
| Rated battery voltage | 24VDC | 48VDC | ||
| Battery input voltage | 21.6~32VDC | 43.2~64VDC | ||
| Max. battery charging current | 60A | 100A | 50A | 80A |
| Inverter output | ||||
| Continuous output power | 2000W | 3000W | 3000W | 5000W |
| Max. surge power(3S) | 4000W | 6000W | 6000W | 8000W |
| Output voltage range | 220VAC(-6%~+3%), 230VAC(-10%~+3%) | |||
| Output frequency | 50/60±0.2% | |||
| Output wave | Pure Sine Wave | |||
| Load power factor | 0.2-1(Load power ≤ Continuous output power) | |||
| Distortion THD | THD≤3%(Resistive load) | |||
| 80% rated output efficiency | 92% | 92% | 92% | 92% |
| Max. Rated output efficiency | 91% | 91% | 90% | 91% |
| Max. output efficiency | 93% | 93% | 93% | 93% |
| Switch time | 10ms (Utility to Inverter), 15ms (Inverter to Utility) | |||
| Utility charging | ||||
| Utility input voltage | 176VAC~264VAC (Default), 90VAC~280VAC (Programmable) | |||
| Utility input frequency | 40~65Hz | |||
| Max. utility charge current | 60A (30A if 90-180VAC) | 80A (40A if 90-180VAC) | 40A (20A if 90-180VAC) | 60A (30A if 90-180VAC) |
| Solar charging | ||||
| Max. PV open circuit voltage | 450V (min. temp), 395V (25°C) | 500V (min. temp), 440V (25°C) | ||
| MPPT voltage range | 80~350V | 120~400V | ||
| Max. PV input power | 2500W | 4000W | 4000W | 4000W |
| Max. PV charging power | 1725W | 2875W | 2875W | 4000W |
| Max. PV charging current | 60A | 100A | 50A | 80A |
| Equalize charging voltage | 29.2V (AGM default) | 58.4V (AGM default) | ||
| Boost charging voltage | 28.8V (AGM default) | 57.6V (AGM default) | ||
| Float charging voltage | 27.6V (AGM default) | 55.2V (AGM default) | ||
| Low voltage disconnect voltage | 21.6V (AGM default) | 43.2V (AGM default) | ||
| Tracking efficiency | ≥99.5% | |||
| Temp. compensate coefficient | -3mV/°C/2V (Default) | |||
| General | ||||
| Surge current | 50A | 60A | 56A | 95A |
| Zero load consumption | <1.8A | <1.2A | ||
| (without PV and utility connection, turn on the load output) | ||||
| Standby current | <1.2A | <0.7A | ||
| (without PV and utility connection, turn off the load output) | ||||
| Mechanical Parameters | ||||
| Dimension(H x W x D) | 607.5x381.6x127mm | 642.5x381.6x149mm | 607.5x381.6x149mm | 642.5x381.6x149mm |
| Mounting size | 585*300mm | 620*300mm | 585*300mm | 620*300mm |
| Mounting hole size | Φ10mm | |||
| Net Weight | 15kg | 19kg | 18kg | 19kg |
| Enclosure | IP30 | |||
| Relative humidity | < 95% (N.C.) | |||
| Environment temperature | -20°C to 50°C | |||
9. User Tips
- Model Selection: When purchasing, ensure you select the correct model (e.g., 3KW for 24V or 5KW for 48V) that matches your system requirements. Refer to the specifications table for detailed power and voltage ratings.
- Battery Compatibility: The inverter is designed to work perfectly with lithium battery systems, offering surge current and reverse connection protections. Ensure your battery type is correctly configured in the inverter settings.
- Remote Monitoring: Consider utilizing the optional WiFi or GPRS remote control modules via the RS485 port for convenient monitoring and management of your system from a distance.
10. Warranty and Support
The Epever UPower-Hi series inverter comes with a warranty period of More than 3 years, ensuring peace of mind regarding product quality and reliability.