1. Overview
The Tracer-AN series charge controller utilizes advanced MPPT (Maximum Power Point Tracking) technology to efficiently track the maximum power point (MPP) of a solar array. This ensures optimal solar energy harvesting, providing up to 30% more power compared to traditional PWM charge controllers. Designed to work with solar panels for on-grid applications, this series supports a maximum open-circuit voltage (Voc) of 100V. The integrated multifunction LCD vividly displays system status and parameters.

Key Features:
- Advanced MPPT algorithm with tracking efficiency no less than 99.5%.
- Ultra-fast tracking speed and guaranteed tracking efficiency.
- Maximum DC/DC conversion efficiency of 98%.
- Automatic limitation of charging current and power.
- Wider MPPT working voltage range.
- Support for lead-acid and lithium batteries; voltage parameters are configurable.
- Programmable temperature compensation feature.
- Real-time energy statistics function.
- High-temperature charging automatic power reduction function.
- Multiple load work modes.
- High quality and low failure rate components for extended service life.
- 100% charging and discharging in the environment temperature range.
- Standard Modbus communication protocol via RS485 for extended communication distance.
- Power protection chip for 5VDC/200mA output with over-current and short-circuit protections.
- Support for monitoring and parameter setting via APP or PC software.
- Comprehensive electronic protection.
2. Important Safety Instructions
Please review these instructions carefully before installation and operation to ensure safe and proper use of your Tracer-AN series MPPT solar controller.
- Read all instructions and warnings thoroughly before installation.
- The controller contains no user-serviceable components. Do not disassemble or attempt repairs.
- Mount the controller indoors. Avoid exposure to moisture or water ingress.
- Install the controller in a well-ventilated area. The heat sink may become hot during operation.
- It is recommended to install appropriate external fast-acting fuses/breakers.
- Disconnect PV array connections and battery fuses/breakers before any installation or adjustment.
- Ensure all power connections are tight to prevent excessive heating from loose connections.
WARNING
Do not install the controller in humid, salt spray, corrosive, greasy, flammable, explosive, or dusty environments.
3. Product Characteristics


Component Identification:
| No. | Feature | No. | Feature |
|---|---|---|---|
| 1 | SELECT button | 6 | RS485 port |
| 2 | RTS Interface | 7 | Mounting Hole Φ5mm |
| 3 | PV Terminals | 8 | ENTER button |
| 4 | Battery Terminals | 9 | LCD |
| 5 | Load Terminals |
Note: If the remote temperature sensor is not connected or is damaged, the controller will charge or discharge the battery at the default temperature setting of 25°C (no temperature compensation).
4. Installation
4.1 General Attentions
- Wear eye protection when installing open-type lead-acid batteries and rinse with clean water if battery acid contact occurs.
- Keep the battery away from metal objects to prevent short circuits.
- Ensure the environment is well-ventilated, especially when charging, due to potential acid gas generation.
- Avoid direct sunlight and rain infiltration when installing outdoors.
- Ensure tight power connections and secure cables with clamps to prevent high heat, wire insulation melting, or fire.
- Only charge lead-acid and lithium-ion batteries within the controller's specified range.
- The battery connector can be wired to a single battery or a bank of batteries.
- Select system cables with a current density of 5A/mm² or less.
4.2 Mounting
The controller requires at least 150mm of clearance above and below for proper airflow and heat dissipation. Ventilation is highly recommended if mounted in an enclosure.

WARNING
- Risk of explosion! Never install the controller in a sealed enclosure with flooded batteries. Do not install the controller in a confined area where battery gas can accumulate.
- Risk of electric shock! The PV array can generate a high open-circuit voltage. Disconnect the breaker or fast-acting fuse first, and be careful when wiring.
4.3 Wiring Diagram and Connection Order
Connect the solar system in the following order: 1. Battery → 2. Load → 3. PV Array. Disconnect the system in the reverse order: 3. PV Array → 2. Load → 1. Battery.

CAUTION
- Do not connect the circuit breaker or fast-acting fuse during wiring. Ensure correct electrode polarity.
- A fast-acting fuse (1.25 to 2 times the controller's rated current) must be installed on the battery side, no longer than 150mm from the battery.
4.4 PV Array Requirements
The controller is compatible with various PV modules. The following tables provide guidance for serial connections based on open-circuit voltage (Voc) and maximum power point voltage (VMPP).
Tracer1206AN/Tracer2206AN:
| System voltage | 36cell (Voc< 23V) | 48cell (Voc< 31V) | 54cell (Voc< 34V) | 60cell (Voc< 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 2 | 2 | 1 | 1 | 1 | 1 | 1 | 1 |
| 24V | 2 | 2 | - | - | - | - | - | - |
| System voltage | 72cell (Voc< 46V) | 96cell (Voc< 62V) | Thin-Film module (Voc> 80V) | ||
|---|---|---|---|---|---|
| Max. | Best | Max. | Best | ||
| 12V | 1 | 1 | - | - | - |
| 24V | 1 | 1 | 1 | 1 | 1 |
Tracer1210/2210/3210/4210AN:
| System voltage | 36cell (Voc< 23V) | 48cell (Voc< 31V) | 54cell (Voc< 34V) | 60cell (Voc< 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 | 2 | 1 | 2 | 1 |
| 24V | 4 | 3 | 2 | 2 | 2 | 2 | 2 | 2 |
| System voltage | 72cell (Voc< 46V) | 96cell (Voc< 62V) | Thin-Film module (Voc> 80V) | ||
|---|---|---|---|---|---|
| Max. | Best | Max. | Best | ||
| 12V | 2 | 1 | 1 | 1 | 1 |
| 24V | 2 | 1 | 1 | 1 | 1 |
CAUTION
The above parameters are calculated under STC (Standard Test Condition): module temperature 25°C, air mass 1.5, irradiance 1000W/m². The total voltage must not exceed the PV open circuit voltage (46V for Tracer**06AN or 92V for Tracer**10AN at 25°C environment temperature).
4.5 Wire Size
The PV array's output current varies with size, connection method, and sunlight angle. The minimum wire size can be calculated using the ISC (short circuit current) value from the PV module's specifications. The PV array's ISC must not exceed the controller's maximum PV input current.
| Model | Max. PV input current | Max. PV wire size |
|---|---|---|
| Tracer1206AN / Tracer1210AN | 10A | 4mm²/12AWG |
| Tracer2206AN / Tracer2210AN | 20A | 6mm²/10AWG |
| Tracer3210AN | 30A | 10mm²/8AWG |
| Tracer4210AN | 40A | 16mm²/6AWG |
The battery and load wire size should conform to the rated current. The following table provides reference sizes:
| Model | Rated charge current | Rated discharge current | Battery wire size | Load wire size |
|---|---|---|---|---|
| Tracer1206AN / Tracer1210AN | 10A | 10A | 4mm²/12AWG | 4mm²/12AWG |
| Tracer2206AN / Tracer2210AN | 20A | 20A | 6mm²/10AWG | 6mm²/10AWG |
| Tracer3210AN | 30A | 30A | 10mm²/8AWG | 10mm²/8AWG |
| Tracer4210AN | 40A | 40A | 16mm²/6AWG | 16mm²/6AWG |
CAUTION
- Wire sizes are for reference only. For long distances between the PV array/controller or controller/battery, use larger wires to reduce voltage drop.
- The recommended wire is selected for the battery based on the condition that its terminals are not connected to any additional inverter.
4.6 Grounding
Tracer-AN series controllers are common-negative. Negative terminals of the PV array, battery, and load can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on the controller's shell must be grounded to shield electromagnetic interference and prevent electric shock.
CAUTION
It is recommended to use a common-negative controller for common-negative systems (e.g., RV systems). The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in a common-negative system.
4.7 Connecting Accessories
Temperature Sensor
Connect one end of the remote temperature sensor cable to the controller's interface and place the other end close to the battery.

CAUTION
If the remote temperature sensor is not connected or damaged, the controller will charge or discharge the battery at the default 25°C setting (no temperature compensation).
RS485 Communication
The RS485 port allows for communication with external devices. Refer to the 'Setting' section for configuration.
CAUTION
The internal circuit of the RS485 port has no isolation design. Connecting an RS485 communication isolator to the port is recommended before communicating.
4.8 Powering On the Controller
Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (it should be lit green for normal operation). Then, connect the fast-acting fuse and circuit breaker of the load and PV array. The system will then operate in preprogrammed mode.
CAUTION
If the controller is not operating properly or the battery indicator shows an abnormality, refer to the 'Troubleshooting' section.
5. Operation
5.1 Buttons
The controller features two buttons: SELECT and ENTER, for navigation and setting parameters.
| Mode | Note |
|---|---|
| Load ON/OFF | Toggle load On/Off via the ENTER button in manual load mode. |
| Clear fault | Press the ENTER button. |
| Browsing mode | Press the SELECT button to cycle through display interfaces. |
| Setting mode | Press and hold ENTER for 5s to enter setting mode. Use SELECT to set parameters and ENTER to confirm. Exits automatically after 10s of inactivity. |
5.2 Interface Display
The LCD provides real-time status and operational data.

Status Description:
| Name | Icon | Status |
|---|---|---|
| PV array | Solar panel icon | Day / Night |
| Battery | Battery icon | No charge / Charging / Battery capacity / Battery Voltage, Current, Temperature / Battery type |
| Load | Light bulb icon | Load ON / Load OFF / Current/Consumed energy/Load mode |
Error Codes:
| Status | Icon | Instruction |
|---|---|---|
| Battery over-discharged | Battery icon with exclamation | Battery level empty, frame blink, fault icon blink |
| Battery over voltage | Battery icon with exclamation | Battery level full, frame blink, fault icon blink |
| Battery overheating | Battery icon with exclamation | Battery level current value, frame blink, fault icon blink |
| Load failure | Light bulb icon with exclamation | Overload, Load short circuit |
Note: When the load current exceeds 1.02-1.05 times, 1.05-1.25 times, 1.25-1.35 times, and 1.35-1.5 times the rated value, the controller will automatically turn off the loads in 50, 30, 10, and 2 seconds respectively.
5.3 Settings
5.3.1 Clear Generated Energy
- Press and hold the ENTER button for 5s under the PV-generated energy interface; the value will flash.
- Press the ENTER button again to clear the generated energy.
5.3.2 Switch Battery Temperature Unit
Press and hold the button for 5s under the battery temperature interface to switch the temperature unit.
5.3.3 Battery Type Setting
The controller supports various battery types. You can set the battery type locally or remotely.
Supported Battery Types:
| No. | Type | Description |
|---|---|---|
| 1 | Battery | Sealed (default), Gel, Flooded |
| 2 | Lithium battery | LiFePO4 (4S/12V; 8S/24V), Li(NiCoMn)O2 (3S/12V; 6S/24V; 7S/24V) |
| 3 | User | Customizable parameters |

Local Setting of Battery Type:
- Press the SELECT button to navigate to the battery voltage interface.
- Press and hold the ENTER button until the battery-type interface flashes.
- Press the SELECT button to change the battery type.
- Press the ENTER button to confirm.
Remote Setting of Battery Parameters:
- Via Remote Meter (MT50): Connect the controller to the MT50 remote meter via a standard network cable. After selecting 'USE' as the battery type, set voltage parameters on the MT50.
- Via PC Software: Connect the controller's RJ45 interface to a PC's USB interface using a USB to RS485 cable. Set voltage parameters via the PC software after selecting 'USE' as the battery type.
- Via Phone APP (Android or iOS): Connect the controller to an external WIFI or Bluetooth module via a standard network cable. Set voltage parameters via the APP after selecting 'USE' as the battery type.

5.3.4 Load Modes
The controller supports various load work modes. When the LCD shows the load type interface, you can set the load mode.
| Code (1**) | Timer 1 | Code (2**) | Timer 2 |
|---|---|---|---|
| 100 | Light ON/OFF | 2n | Disabled |
| 101 | Load on for 1 hour since sunset | 201 | Load on for 1 hour before sunrise |
| 102 | Load on for 2 hours since sunset | 202 | Load on for 2 hours before sunrise |
| 103~113 | Load on for 3~13 hours since sunset | 203~213 | Load on for 3~13 hours before sunrise |
| 114 | Load on for 14 hours since sunset | 214 | Load on for 14 hours before sunrise |
| 115 | Load on for 15 hours since sunset | 215 | Load on for 15 hours before sunrise |
| 116 | Test mode | 2n | Disabled |
| 117 | Manual mode (Default load ON) | 2n | Disabled |
CAUTION
When selecting Light ON/OFF, Test mode, or Manual mode, only Timer 1 can be set, and Timer 2 is disabled.
6. Maintenance
Regular inspection and maintenance are crucial for optimal performance. The following tasks are recommended at least twice yearly:
- Ensure no obstructions block airflow around the controller. Clean any dirt or debris from the radiator.
- Inspect all exposed wires for insulation damage (due to sun, friction, dryness, insects, or rodents). Repair or replace damaged wires as needed.
- Verify that the indicator display matches actual operation. Address any troubleshooting or error conditions promptly.
- Check terminals for corrosion, insulation damage, high temperature signs, or discoloration. Tighten terminal screws to the recommended torque.
- Clean dirt, nesting insects, and corrosion from the unit.
- Confirm the lightning arrester is in good condition. Replace if necessary to prevent damage to the controller and other equipment.
CAUTION
Risk of electric shock! Ensure that the power is turned off before performing any maintenance operations.
7. Troubleshooting
This section provides solutions for common issues you might encounter with your EPEVER MPPT Solar Charge Controller.
| Fault | Troubleshooting |
|---|---|
| PV array open-circuit (LCD shows no PV activity despite direct sunlight) | Confirm that the PV array connection is correct and tight. |
| Battery voltage is lower than 8V | Check the battery's voltage (at least 8V is needed to activate the controller). |
| Battery over voltage (Battery frame blinks) | Check if the battery voltage is higher than OVD (over voltage disconnect voltage) and disconnect the PV array connection. |
| Battery discharged (Battery frame blinks) | When battery voltage restores to or above LVR (low voltage reconnect voltage), the load will recover. Use other methods to recharge the battery. |
| Battery overheating (Battery frame blinks) | The controller will resume once the temperature declines below 55°C. |
| Overload (Load off) | Reduce the number of electric devices. Restart the controller or press the button to clear faults. |
| Load short-circuit (Load and fault icons) | Carefully check load connections and clear the fault. Restart the controller or press the button to clear faults. |
| PV Over Current | If actual PV array charging current/power exceeds rated, controller will charge at rated current/power. |
| PV short-circuit protection | Controller is not damaged if PV array is short-circuited when not charging. WARNING: Do not short-circuit PV array during charging. |
| PV reverse polarity protection | Controller not damaged, resumes work after correcting mis-wiring. CAUTION: If PV array is reversed and actual power is 1.5x controller's rated power, controller may be damaged. |
| Night reverse charging protection | Prevents battery discharge to PV module at night. |
| Battery reverse protection | Controller not damaged, resumes normal operation after correcting mis-wiring. CAUTION: For lithium batteries, if battery connection is reversed while PV array is correct, controller will be damaged. |
| Device overheating protection | Controller stops working if internal temperature > 85°C, resumes when < 75°C. |
| TVS high voltage transients protection | Internal TVS protects against high-voltage surge pulses. For areas with frequent lightning, an external surge arrester is recommended. |
8. Specifications
Electrical Parameters
| Parameter | Tracer1206AN / Tracer1210AN | Tracer2206AN / Tracer2210AN | Tracer3210AN | Tracer4210AN | ||
|---|---|---|---|---|---|---|
| 1206AN | 1210AN | 2206AN | 2210AN | |||
| System rated voltage | 12/24VDC Auto-recognition | |||||
| Rated charging current | 10A | 10A | 20A | 20A | 30A | 40A |
| Rated discharge current | 10A | 10A | 20A | 20A | 30A | 40A |
| Controller working voltage range | 8~32V | |||||
| Max. PV open circuit voltage | 60V (46V at 25°C) | 100V (92V at 25°C) | ||||
| MPPT voltage range | (Battery voltage +2V)~36V | (Battery voltage +2V)~72V | ||||
| PV rated charge power (12V/24V) | 130W/260W | 260W/520W | 390W/780W | 520W/1040W | ||
| Self-consumption | ≤12mA | |||||
| Discharge circuit voltage drop | ≤0.23V | |||||
| Temperature compensate coefficient | -3mV/°C/2V (Default) | |||||
| Grounding type | Common negative | |||||
| RS485 port | 5VDC/200mA | |||||
| LCD backlight time | Default:60S, Range:0~999S (0 seconds: backlight is ON all the time) | |||||
Environmental Parameters
| Parameter | Value |
|---|---|
| Environment temperature | -25°C~+45°C (100% loads working) |
| Storage temperature | -20°C~+70°C |
| Relative humidity | < 95% (N.C.) |
| Enclosure | IP30 |
Mechanical Parameters
| Model | Tracer1206AN / Tracer1210AN | Tracer2206AN / Tracer2210AN | Tracer3210AN | Tracer4210AN | ||
|---|---|---|---|---|---|---|
| 1206AN | 1210AN | 2206AN | 2210AN | |||
| Dimension (L x W x H) | 172x139x44mm | 220x154x52mm | 228x164x55mm | 252x180x63mm | ||
| Mounting size (L x W) | 124x130mm | 170x145mm | 170x155mm | 204x171mm | ||
| Mounting hole size | Φ5mm | |||||
| Wire size / Recommended cable | 12AWG(4mm²) | 6AWG(16mm²) | 8AWG(10mm²) | 6AWG(16mm²) | ||
| Net Weight | 0.57kg | 0.94kg | 1.26kg | 1.65kg | ||
For detailed conversion efficiency curves, please refer to the full user manual PDF: EPEVER MPPT Solar Charge Controller User Manual (PDF).
9. User Tips
- Battery First: Always connect the battery to the charge controller BEFORE connecting the solar panel array. Disconnect in reverse order.
- No Direct Inverter/Charger Connection: Do NOT connect any inverter, wind turbine, alternator, or other charger directly to the charge controller. Always connect these through the battery, and ensure a fuse is in place.
- Wire Sizing: If there is a significant distance between the PV array and the controller, or between the controller and the battery, use larger gauge wires than the minimum recommended to minimize voltage drop and improve system performance.
- Lithium Battery Programming: To program parameters for lithium batteries, you can use a Remote Meter (like the MT50), PC Software (requires an RS485 cable like CC-USB-RS485-150U), or a Phone App (Android or iOS, requires a WIFI or BLE module).
10. Frequently Asked Questions
- Q: What should I do if the controller is not operating properly?
- A: Refer to the 'Troubleshooting' section in this manual. Check all connections, ensure correct polarity, and verify battery voltage. If issues persist, consult the full PDF manual or contact support.
- Q: Can I install the controller outdoors?
- A: The controller should be mounted indoors. Avoid direct sunlight, rain, and harsh environmental conditions like high humidity, salt spray, or explosive atmospheres.
- Q: How do I know if my battery type is correctly set?
- A: You can check and set the battery type via the controller's LCD interface or remotely using an MT50 remote meter, PC software, or mobile app. Ensure the selected type matches your battery chemistry (e.g., Sealed, Gel, Flooded, LiFePO4, Li(NiCoMn)O2).