1. Introduction
The EPEVER Tracer AN series MPPT Solar Charge Controller is designed with a common positive grounding and features an advanced Maximum Power Point Tracking (MPPT) control algorithm. This technology enables the controller to quickly and accurately track the maximum power point (MPP) of the solar array under any conditions, thereby improving energy efficiency and maximizing solar energy harvest.

Key Features:
- Advanced MPPT technology for optimal power harvesting.
- High tracking efficiency of no less than 99.5%.
- Peak conversion efficiency of 98%.
- Accurate recognition and tracking of multiple power points.
- Multi-function LCD for intuitive display of system information.
- Common positive grounding design for system compatibility.
- RS485 port with industrial standard MODBUS open architecture for communication.
- Fully programmable functions via PC software or remote meter.
2. Product Components and Optional Accessories
The Tracer AN series controller comes with essential components for its operation. Additionally, several optional accessories are available to enhance functionality and monitoring capabilities.

Optional Accessories:
- Remote Meter (MT50): Allows users to set controller parameters and monitor system status via an LCD display.
- Data Logger (eLOG01): Provides real-time parameter recording of the product through the RS485 communication mode.
- Bluetooth Adapter (Box-BLE-01): Includes a 2m communication cable for connecting the controller to a mobile device via Bluetooth (for controllers with an RS485 port).
- WiFi Adapter (eBox-WIFI-01): Includes a 2m communication cable for connecting the controller to a network via WiFi (for controllers with an RS485 port).
- Remote Temperature Sensor (RTS300R47K3.81A): A 3-meter sensor for accurate battery temperature compensation.
- Communication Cable (CC-USB-RS485-150U): A 1.5-meter USB to RS485 PC communication cable for connecting the controller to a computer.
- OTG Cable (OTG-12CM): Used to connect the controller to a mobile application.
3. Specifications
| Item No. | Tracer 5210AN | Tracer 6210AN | Tracer 5415AN | Tracer 6415AN | Tracer 8415AN | Tracer 10415AN | Tracer 5420AN | Tracer 6420AN | Tracer 8420AN | Tracer 10420AN | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal system voltage | 12/24VDC Auto | 12/24VDC Auto | |||||||||||
| Battery input voltage | 8V~32V | 8V~68V | |||||||||||
| Battery type | Sealed (default) / Gel / Flooded / User | ||||||||||||
| Battery fuse | 80A/58V | 150A/58V | 80A/58V | 150A/58V | |||||||||
| Rated charge current | 50A | 60A | 50A | 60A | 80A | 100A | 50A | 60A | 80A | 100A | |||
| Rated charge power | 625W/12V 1250W/24V | 750W/12V 1500W/24V | 625W/12V 1250W/24V 1875W/36V 2500W/48V | 750W/12V 1500W/24V 2250W/36V 3000W/48V | 1000W/12V 2000W/24V 3000W/36V 4000W/48V | 1250W/12V 2500W/24V 3750W/36V 5000W/48V | 625W/12V 1250W/24V 1875W/36V 2500W/48V | 750W/12V 1500W/24V 2250W/36V 3000W/48V | 1000W/12V 2000W/24V 3000W/36V 4000W/48V | 1250W/12V 2500W/24V 3750W/36V 5000W/48V | |||
| Max. PV open circuit voltage | 100V (92V) | 150V (138V) | 200V (180V) | ||||||||||
| MPP voltage range | (Battery voltage +2V) ~ 72V | (Battery voltage +2V) ~ 108V | (Battery voltage +2V) ~ 144V | ||||||||||
| Tracking efficiency | >99.5% | ||||||||||||
| Max. conversion efficiency | 98.0% | 98.0% | 98.3% | 98.6% | 98.5% | 98.6% | 98.3% | 98.1% | 98.5% | 98.5% | |||
| Full load efficiency | 97.0% | 97.0% | 97.8% | 98.0% | 98.0% | 98.0% | 97.1% | 97.5% | 97.5% | 97.6% | |||
| Self-consumption | 98mA/12V, 60mA/24V, 50mA/36V, 46mA/48V | ||||||||||||
| Grounding | Common negative grounding | ||||||||||||
| Temperature compensate coefficient | -3mV/℃/2V (Default) | ||||||||||||
| LCD backlight time | 60S (Default), Range: 0~999S (0S: backlight is ON all the time) | ||||||||||||
4. Installation and Setup
Proper installation is crucial for the safe and efficient operation of your solar charge controller. Please follow these steps carefully.
4.1 Mounting the Controller
- Choose a well-ventilated, dry location away from direct sunlight, high temperatures, and water.
- Ensure there is sufficient space around the controller for heat dissipation.
- Mount the controller vertically on a wall or other stable surface using appropriate fasteners.
4.2 Wiring Sequence
Always connect components in the specified order to prevent damage to the controller or other system components. Use appropriate wire gauges for your system's current and distance.

- Connect the Battery: Connect the battery to the controller's battery terminals (marked with a battery symbol). Ensure correct polarity (+ to + and - to -). The controller will detect the system voltage automatically.
- Connect the Solar Panel: Connect the solar panel array to the controller's PV terminals (marked with a solar panel symbol). Ensure correct polarity.
- Connect the Load (Optional): If using a DC load directly from the controller, connect it to the load terminals (marked with a light bulb symbol). Ensure correct polarity.
WARNING: Incorrect wiring sequence can damage the controller and other components. Always connect the battery first, then the solar panel, and finally the load.
5. Operation
The Tracer AN series controller features a multi-function LCD display and control buttons for easy monitoring and parameter adjustment.
5.1 LCD Display and Buttons

- SELECT Button: Used to navigate through different display screens and menu options.
- ENTER Button: Used to confirm selections or enter a menu for parameter modification.
The LCD intuitively displays various system information such as battery voltage, charging current, solar panel voltage, and load status. Refer to the detailed manual (if available) for a complete list of display screens and their meanings.
5.2 Parameter Programming
The controller's parameters can be fully programmed using:
- Remote Meter (MT50): Connect the MT50 to the controller's RS485 port to access and modify settings.
- PC Software: Use the CC-USB-RS485-150U communication cable to connect the controller to a computer and use the dedicated PC software for advanced configuration.
- Mobile App: Connect via the Bluetooth adapter (Box-BLE-01) or WiFi adapter (eBox-WIFI-01) and the OTG cable (OTG-12CM) to manage settings from a mobile device.
Programmable parameters include battery type, charge voltage settings, load control modes, and more. Always ensure settings match your battery type and system requirements.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your solar charge controller.
- Check Connections: Periodically inspect all wiring connections to ensure they are tight and free from corrosion. Loose connections can cause overheating and system malfunction.
- Clean Terminals: If corrosion is present, disconnect power and clean the terminals thoroughly.
- Inspect for Damage: Check the controller for any physical damage, cracks, or signs of overheating.
- Ensure Ventilation: Make sure the area around the controller is clear of obstructions to allow for proper airflow and heat dissipation. Dust and debris can accumulate and hinder cooling.
- Battery Inspection: Regularly check your battery bank for signs of wear, corrosion, or fluid levels (for flooded batteries).
WARNING: Before performing any maintenance, ensure all power sources (solar panels and battery) are disconnected from the controller.
7. Troubleshooting
This section provides solutions to common issues you might encounter with your Tracer AN series solar charge controller.
Common Issues and Solutions:
- No Display/Controller Not Powering On:
- Check battery connections and ensure they are secure and have correct polarity.
- Verify battery voltage is within the controller's operating range (8V~32V for 12/24V systems, 8V~68V for 12/24/36/48V systems).
- Check the battery fuse for continuity.
- No Charging from Solar Panels:
- Ensure solar panel connections are secure and have correct polarity.
- Check solar panel open circuit voltage (Voc) and ensure it is within the controller's maximum PV open circuit voltage limit (e.g., 100V, 150V, or 200V depending on model).
- Verify there is sufficient sunlight reaching the solar panels.
- Check for any shading on the solar panels.
- Load Not Working:
- Check load connections and ensure correct polarity.
- Verify the load is not exceeding the controller's rated load current.
- Check the battery voltage; if it's too low, the controller may have disconnected the load to protect the battery.
- Ensure the load control mode is correctly configured (e.g., always on, dusk to dawn, timer).
- Controller Overheating:
- Ensure adequate ventilation around the controller.
- Reduce the load or solar input if consistently operating at maximum capacity in high ambient temperatures.
For more complex issues, consult the full product manual or contact technical support.
8. User Tips
No specific user tips were available from buyer reviews or Q&A for this product at this time. However, general best practices for solar charge controllers include:
- Always ensure your battery bank is adequately sized for your solar array and load to prevent over-discharge or under-charging.
- If using a remote temperature sensor, ensure it is properly attached to the battery for accurate temperature compensation, which is vital for battery health.
- Regularly monitor your system's performance via the LCD display or optional remote monitoring tools to catch potential issues early.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt and product serial number handy when contacting support.