1. Overview
The EPEVER Tracer-AN series MPPT (Maximum Power Point Tracking) solar charge controller is designed to efficiently manage power flow from solar panels to batteries. It utilizes advanced MPPT technology to track the maximum power point of the solar array, ensuring maximum energy harvest. This series supports 12V/24V battery systems and is available in 10A, 20A, 30A, and 40A current ratings. It can handle a maximum PV open circuit voltage of 100V and is compatible with solar panels designed for on-grid applications. The integrated LCD provides real-time system status information.
Key Features:
- MPPT tracking efficiency above 99.5%
- Maximum charge conversion efficiency as high as 98%
- Supports lead-acid (Sealed, Gel, Flooded) and lithium-ion (LiFePO4, Li(NiCoMN)O2) batteries, as well as user-defined types.
- Multiple load work modes for versatile application.
- Charging power and current limitation function.
- High-temperature charging power derating function to protect the device.
- Standard Modbus communication protocol with RS485 interface for external monitoring and control.
- Real-time energy statistics function.
2. Product Components
The Tracer-AN series controller features a clear LCD display and intuitive buttons for operation. Key interfaces are provided for system connections.
| No. | Component | Description |
|---|---|---|
| 1 | SELECT button | Used to navigate menus and select options. |
| 2 | RTS* Interface | Remote Temperature Sensor interface. |
| 3 | PV Terminals | Connection points for solar panel array. |
| 4 | Battery Terminals | Connection points for battery bank. |
| 5 | Load Terminals | Connection points for DC loads. |
| 6 | RS485 communication interface | For connecting to PC, remote meter, or communication modules. |
| 7 | Mounting Hole Φ5mm | For securing the controller to a surface. |
| 8 | ENTER button | Used to confirm selections and enter menus. |
| 9 | LCD | Liquid Crystal Display for system information. |
*Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature setting of 25°C.
3. Setup Instructions
3.1 Safety Precautions
- Ensure all connections are tight and secure to prevent loose connections and overheating.
- Always wear appropriate personal protective equipment (PPE) when working with electrical systems.
- Install the controller in a well-ventilated area, away from flammable materials and direct sunlight.
- Ensure the system voltage is within the controller's specified range.
3.2 Connection Order
It is crucial to follow the correct connection and disconnection order to prevent damage to the controller and other system components.
- Connect the Battery: Connect the battery to the controller first. Ensure correct polarity (positive to positive, negative to negative).
- Connect the Load: Connect the DC load to the controller.
- Connect the PV Array: Finally, connect the solar panel array to the controller.
To disconnect the system, follow the reverse order: 3. PV array → 2. load → 1. battery.
3.3 Important Notes for Installation
- Battery First: The battery must always be connected first. Never connect the solar panel array to the controller without or before connecting the battery.
- No Direct Inverter/Charger Connection: DO NOT connect any inverter, wind turbine, alternator, or external charger directly into the charge controller. These devices should be connected with the battery and an appropriate fuse.
- Wire Sizing: If there is a long distance between the PV array and the controller, or between the controller and the battery, larger gauge wires should be used to minimize voltage drop and improve system performance. Refer to the full manual for recommended wire sizes.
4. Operating Instructions
4.1 Battery Type Selection
The controller supports various battery types. It is essential to select the correct battery type for optimal charging and battery longevity. The default setting is Sealed lead-acid battery.
To program for Lithium Batteries or other user-defined types, you can use one of the following methods:
- Via Remote Meter (MT50): Connect an optional MT50 remote meter to the controller to access and modify battery parameters.
- Via PC Software: Use the EPEVER PC software with an RS485 communication cable (e.g., CC-USB-RS485-150U) to configure settings.
- Via Phone App (Android or iOS): Connect via an optional WiFi or Bluetooth module to use the mobile application for parameter adjustments.
4.2 Load Control Modes
The controller offers multiple load control modes to manage the DC output to your loads:
- Manual: The load can be switched ON/OFF manually via the controller's buttons.
- Dusk to Dawn with Timer: The load automatically turns ON at dusk and turns OFF after a set duration.
- Timer: Allows setting exact ON and OFF times for the load.
- Dusk to Dawn: The load automatically turns ON at dusk and OFF at dawn by detecting PV voltage.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your solar charge controller and overall system.
- Inspect Connections: Periodically check all wiring connections for tightness, corrosion, or damage. Loose connections can cause overheating and system malfunction.
- Clean the Controller: Keep the controller's exterior clean and free from dust and debris. Use a dry cloth for cleaning. Ensure ventilation openings are not blocked.
- Check Battery Health: Monitor battery voltage and performance regularly. Ensure the battery type setting on the controller matches your battery.
- Environmental Check: Ensure the installation environment remains within the specified operating temperature range and humidity levels.
- Firmware Updates: Check the manufacturer's website for any available firmware updates that may improve performance or add features.
6. Troubleshooting
The Tracer-AN series controller is equipped with extensive protection features to safeguard your system. If an issue arises, the controller's LCD may display error codes or indicators. Refer to the full product manual for detailed error code explanations and troubleshooting steps.
Common Protection Features:
- Low Voltage Protection
- Over Temperature Protection
- Over Load Protection
- Over Discharge Protection
- Over Voltage Protection
- Overcurrent Protection
- Short Circuit Protection
- Reverse Current Protection
In case of a fault, the controller will typically attempt to recover automatically once the fault condition is removed. If a persistent issue occurs, consult the detailed troubleshooting guide in the comprehensive user manual or contact EPEVER support.
7. Specifications
Detailed technical specifications for the Tracer-AN series MPPT solar charge controllers:
| Model | Tracer1210AN | Tracer2210AN | Tracer3210AN | Tracer4210AN |
|---|---|---|---|---|
| Nominal system voltage | 12/24VDC/Auto | |||
| Battery type | Lead-acid (Sealed/Gel/Flooded) / Lithium (LiFePO4/Li(NiCoMN)O2) / User | |||
| Battery input voltage range | 8~32V | |||
| Rated charge current | 10A | 20A | 30A | 40A |
| Rated discharge current | 10A | 20A | 30A | 40A |
| Rated charge power | 130W/12V, 260W/24V | 260W/12V, 520W/24V | 390W/12V, 780W/24V | 520W/12V, 1040W/24V |
| Max. conversion efficiency | ≤98.0% | |||
| Tracking efficiency | ≥99.5% | |||
| MPP voltage range | (Battery Voltage+2V)~72V | |||
| Max. PV open circuit voltage | 100V (At minimum operating environment temperature), 92V (At 25℃ environment temperature) | |||
| Equalization voltage | Sealed:14.6V, Flooded:14.8V, User-defined:9-17V | |||
| Boost voltage | Gel:14.2V, Sealed:14.4V, Flooded:14.6V, User-defined:9-17V | |||
| Float voltage | Gel/Sealed/Flooded:13.8V, User-defined:9-17V | |||
| Low voltage reconnect voltage | Gel/Sealed/Flooded:12.6V, User-defined:9-17V | |||
| Low voltage disconnect voltage | Gel/Sealed/Flooded:11.1V, User-defined:9-17V | |||
| Self-consumption | ≤12mA | |||
| Temperature compensation (for lead-acid battery) | -3mV/℃/2V (Default) | |||
| Relative humidity | ≤95%, N.C. | |||
| Enclosure | IP30 | |||
| Communication interface | RS485 (RJ45) | |||
| Grounding | Common Negative | |||
| Operating temperature range | -25℃~+45℃ (100% input and output) | |||
| Dimensions (LxWxH)(mm) | 172 x 139 x 44 | 220 x 154 x 52 | 228 x 164 x 55 | 252 x 180 x 63 |
| Net weight | 0.57kg | 0.94kg | 1.26kg | 1.65kg |
8. User Tips
- Monitor Performance: Regularly check the LCD display for charging status, battery voltage, and load current to ensure optimal system performance.
- Optimize Panel Angle: Adjust your solar panel angle seasonally to maximize sun exposure and energy harvest.
- Consider System Expansion: If you plan to expand your solar array or battery bank in the future, ensure your controller has sufficient capacity or plan for an upgrade.
- Remote Monitoring: Utilize optional accessories like the remote meter (MT50) or communication modules (WiFi/Bluetooth) for convenient remote monitoring and parameter adjustment, especially for lithium batteries.
- Fuse Protection: Always use appropriate fuses on all battery and load connections to protect against short circuits and overcurrents.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.