1. Overview
The EPEVER UPower-Hi series is an advanced inverter charger designed for diversified energy management in solar, utility, and generator hybrid systems. It efficiently handles charging from solar, utility, or generator sources and supplies AC loads from utility or inverter power. This system prioritizes solar energy utilization, allowing users to flexibly supplement power from the utility grid as needed. The UPower-Hi series enhances power supply reliability and stability, making it ideal for various off-grid and hybrid power applications.

What is an Inverter/Charger?
An Inverter/Charger, or Combined Inverter Charger, integrates a solar charge controller and an inverter into a single unit. This device converts DC power to AC power and AC power to DC power. This integration offers a cost-effective, efficient, and simplified solution for installation, commissioning, and maintenance in solar energy systems.

2. Key Features
- Flexible Operation: Supports both battery mode and non-battery mode configurations.
- Enhanced Protection: Features surge current and reverse connection protections, ideal for lithium battery systems.
- High MPPT Efficiency: Achieves a Maximum Power Point Tracking (MPPT) efficiency of no less than 99.5%.
- PFC Technology: Utilizes Power Factor Correction (PFC) technology for high power factor AC to DC charging, reducing power grid capacity usage.
- Pure Sine Wave Output: Advanced SPWM technology ensures a pure sine wave output for sensitive electronics.
- Configurable Currents: Allows configuration of battery charging current, discharging current, and grid charging current.
- Smart SOC Function: Incorporates a self-learning State of Charge (SOC) function for optimized battery management.
- User-Friendly Display: Equipped with a 4.2-inch LCD for monitoring system parameters and making adjustments.
- Remote Control Options: Offers optional WiFi and GPRS remote control capabilities via the RS485 isolated communication port.
- BMS Integration: Includes a BMS-Link port and supports an optional BMS-Link communication protocol module for advanced battery management.
3. Applications
The EPEVER UPower-Hi series inverter charger is versatile and suitable for a wide range of applications, providing reliable power in various scenarios:
- Residential: Solar Home systems for household appliances like TVs, refrigerators, computers, microwave ovens, and dishwashers.
- Mobile & Portable: Ideal for Solar Boats, Solar Cars, and Portable Solar Power Generators.
- Off-Grid Systems: Provides stable power where grid access is limited or unavailable.
- Backup Power: Can be integrated into systems requiring backup power from batteries or generators.

4. Product Components and Identification
Familiarize yourself with the various parts and interfaces of your EPEVER UPower-Hi series inverter charger for proper installation and operation.

Part Identification Table

| No. | Item |
|---|---|
| 1 | Utility input terminal |
| 2 | AC output terminal |
| 3 | Terminal covers |
| 4 | Mounting holes (4 Total) |
| 5 | Battery negative input terminal |
| 6 | Battery positive input terminal |
| 7 | PV input terminal (MC4) |
| 8 | External cover |
| 9 | BMS-Link connection port (RJ45, without isolation design) 5VDC/200mA |
| 10 | RTS interface |
| 11 | Dry contact interface |
| 12 | RBVS interface |
| 13 | Cable hole |
| 14 | RS485 interface (DB9 female, with isolation design) 5VDC/200mA |
| 15 | LCD |
| 16 | Power switch |
| 17 | Utility overcurrent protector |
5. Setup
Safety Precautions
- Ensure all power sources are disconnected before installation or maintenance.
- Use appropriate personal protective equipment (PPE).
- All wiring must comply with local and national electrical codes.
- Only qualified personnel should perform installation and wiring.
Mounting the Inverter Charger
The inverter charger should be mounted vertically on a sturdy wall or surface, ensuring adequate ventilation around the unit. Use the four mounting holes provided on the back of the unit.

Wiring Diagrams
The UPower-Hi series supports both battery and non-battery modes. Refer to the diagrams below for correct wiring configurations.
Battery Mode Wiring

General Connection Diagram (Battery and No-Battery Modes)


6. Operating Modes
The UPower-Hi series offers flexible operating modes to optimize energy usage and ensure continuous power supply.
Output Models
- Utility Output: Power is supplied directly from the utility grid.
- Battery Output: Power is supplied from the battery bank via the inverter.
Charging Modes
The inverter charger supports four distinct charging modes, allowing you to prioritize energy sources based on availability and cost.

- Solar Charging: The system primarily charges the battery using solar power.
- Electricity Utility Priority: The utility grid is the primary source for charging the battery and supplying loads. Solar power acts as a supplement.
- Solar Priority: Solar power is the primary source for charging the battery and supplying loads. The utility grid acts as a supplement when solar power is insufficient.
- Hybrid Charging: A combination of solar and utility power is used for charging and supplying loads, optimizing energy flow.
7. Specifications
UP5000-HM8042 Specifications
| Item | UP5000-HM8042 |
|---|---|
| Battery Parameters | |
| Rated battery voltage | 48VDC |
| Battery input voltage | 43.2~64VDC |
| Max. battery charging current | 80A |
| Inverter Output | |
| Continuous output power | 5000W |
| Max. surge power (3S) | 8000W |
| Output voltage range | 220VAC(-6%~+3%), 230VAC(-10%~+3%) |
| Output frequency | 50/60±0.2% |
| Output Wave | Pure Sine Wave |
| Load power factor | 0.2-1 (Load power≤Continuous output power) |
| Distortion THD | THD≤3% (Resistive load) |
| 80% rated output efficiency | 92% |
| Max. Rated output efficiency | 91% |
| Max. output efficiency | 93% |
| Switch time | 10ms (Utility to Inverter); 15ms (Inverter to Utility) |
| Utility Charging | |
| Utility input voltage | 176VAC~264VAC (Default), 90VAC~280VAC (Programmable) |
| Utility input frequency | 40~65Hz |
| Max. utility charge current | 60A (30A if Utility input voltage is 90VAC~180VAC) |
| Solar Charging | |
| Max. PV open circuit voltage | 500V, 440V |
| MPPT voltage range | 120~400V |
| Max. PV input power | 4000W |
| Max. PV charging power | 4000W |
| Max. PV charging current | 80A |
| Equalize charging voltage | 58.4V (AGM default) |
| Boost charging voltage | 57.6V (AGM default) |
| Float charging voltage | 55.2V (AGM default) |
| Low voltage disconnect voltage | 43.2V (AGM default) |
| Tracking efficiency | ≥99.5% |
| Temp. compensate coefficient | -3mV/℃/2V (Default) |
| General | |
| Surge current | 95A |
| Zero load consumption | <1.2A (No PV and utility, AC out is on, fan stops@48V input) |
| Standby current | <0.7A (No PV and utility, AC out is off, fan stops@48V input) |
| Mechanical Parameters | |
| Dimension (H*W*D) | 642.5*381.6*149mm |
| Mounting size | 620*300mm |
| Mounting hole size | φ10mm |
| Net weight | 19kg |
| Environment Parameters | |
| Enclosure | IP30 |
| Relative humidity | <95% (N.C.) |
| Environment temperature | -20℃~50℃ |
| Storage temperature | -25℃~60℃ |
| Altitude | <5000m (If altitude exceeds 1000m, actual output power is reduced per IEC62040.) |
UP3000-HM10022 Specifications
| Item | UP3000-HM10022 |
|---|---|
| Battery Parameters | |
| Rated battery voltage | 24VDC |
| Battery input voltage | 21.6~32VDC |
| Max. battery charging current | 100A |
| Inverter Output | |
| Continuous output power | 3000W |
| Max. surge power (3S) | 6000W |
| Output voltage range | 220VAC(-6%~+3%), 230VAC(-10%~+3%) |
| Output frequency | 50/60±0.2% |
| Output Wave | Pure Sine Wave |
| Load power factor | 0.2-1 (Load power≤Continuous output power) |
| Distortion THD | THD≤3% (Resistive load) |
| 80% rated output efficiency | 92% |
| Max. Rated output efficiency | 91% |
| Max. output efficiency | 93% |
| Switch time | 10ms (Utility to Inverter); 15ms (Inverter to Utility) |
| Utility Charging | |
| Utility input voltage | 176VAC~264VAC (Default), 90VAC~280VAC (Programmable) |
| Utility input frequency | 40~65Hz |
| Max. utility charge current | 80A (40A if Utility input voltage is 90VAC~180VAC) |
| Solar Charging | |
| Max. PV open circuit voltage | 450V, 395V |
| MPPT voltage range | 80~350V |
| Max. PV input power | 4000W |
| Max. PV charging power | 2875W |
| Max. PV charging current | 100A |
| Equalize charging voltage | 29.2V (AGM default) |
| Boost charging voltage | 28.8V (AGM default) |
| Float charging voltage | 27.6V (AGM default) |
| Low voltage disconnect voltage | 21.6V (AGM default) |
| Tracking efficiency | ≥99.5% |
| Temp. compensate coefficient | -3mV/℃/2V (Default) |
| General | |
| Surge current | 60A |
| Zero load consumption | <1.8A (No PV and utility, AC out is on, fan stops@24V input) |
| Standby current | <1.2A (No PV and utility, AC out is off, fan stops@24V input) |
| Mechanical Parameters | |
| Dimension (H*W*D) | 642.5*381.6*149mm |
| Mounting size | 620*300mm |
| Mounting hole size | φ10mm |
| Net weight | 19kg |
| Environment Parameters | |
| Enclosure | IP30 |
| Relative humidity | <95% (N.C.) |
| Environment temperature | -20℃~50℃ |
| Storage temperature | -25℃~60℃ |
| Altitude | <5000m (If altitude exceeds 1000m, actual output power is reduced per IEC62040.) |
8. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter charger.
- Visual Inspection: Periodically check for any visible damage, loose connections, or corrosion on terminals and cables.
- Cleaning: Keep the inverter charger clean and free from dust and debris. Ensure ventilation openings are not blocked. Use a dry cloth for cleaning; do not use liquids.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your device has the latest features and bug fixes.
- Battery Health: If using batteries, regularly monitor their health, voltage, and connections. Ensure they are within the recommended operating parameters.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges.
9. Troubleshooting
This section provides general guidance for common issues. For complex problems, contact EPEVER technical support.
- No Power Output:
- Check if the power switch (16) is ON.
- Verify all input (PV, Utility, Battery) and output (AC Loads) connections are secure.
- Check for any tripped circuit breakers or blown fuses in the system.
- Examine the LCD (15) for error codes or warning messages.
- Battery Not Charging:
- Ensure solar panels are receiving adequate sunlight and are correctly connected to the PV input terminal (7).
- Verify utility input terminal (1) is connected and receiving power if using utility charging.
- Check battery connections (5, 6) and ensure battery voltage is within the acceptable range.
- Confirm charging mode settings on the LCD.
- Inverter Overload:
- Reduce the total load connected to the AC output terminal (2).
- Check the continuous and surge power ratings in the specifications.
- System Shutdowns:
- Could be due to over-temperature, over-voltage, or under-voltage. Check environmental temperature and battery voltage.
- Refer to the LCD for specific shutdown reasons.
10. User Tips
- Optimal Panel Placement: Ensure solar panels are positioned for maximum sun exposure throughout the day to maximize charging efficiency.
- Battery Compatibility: Always use batteries compatible with the inverter's voltage and charging parameters. Lithium batteries are often preferred for their performance and longevity, especially with the inverter's built-in protections.
- Monitor LCD: Regularly check the 4.2-inch LCD display for system status, charging modes, and any alerts to ensure smooth operation.
- Remote Monitoring: Consider utilizing the optional WiFi or GPRS modules for remote monitoring and control, which can provide convenience and early detection of issues.
- Ventilation: Maintain clear airflow around the inverter to prevent overheating, especially in high-power applications.
11. Warranty and Support
EPEVER products are designed for reliability and performance. For detailed warranty information, including terms, conditions, and registration, please refer to the official EPEVER website or the warranty card included with your product.
For technical support, troubleshooting assistance, or service inquiries, please contact EPEVER customer service through their official channels. Ensure you have your product model and serial number ready when seeking support.