1. Introduction
The EPever UP3000 series is an advanced MPPT Solar and Utility Charger Inverter designed for efficient power management in various applications. This hybrid inverter combines solar charging, utility charging, and AC output functionalities into a single unit, offering a reliable and stable power solution.
Key technologies integrated include:
- Optimized MPPT Tracking: The PV charging modules utilize an up-to-date optimized MPPT tracking technology to quickly identify and track the maximum power point of the PV array, maximizing solar energy harvest in real-time.
- Advanced AC-DC Charging: AC-DC charging modules feature an advanced control algorithm for fully digitalized double closed-loop control of voltage and current, ensuring high control precision and compact design. It supports a wide range of AC input voltages and offers continuously adjustable DC charging voltage/current.
- Pure Sine Wave DC-AC Inversion: The DC-AC inverter modules are based on a full digital and intelligent design, employing advanced SPWM technology to output a pure sine wave. It converts 24V/48VDC to 220V/230VAC, making it suitable for a wide array of AC loads including household appliances, electric tools, and commercial units.
- User-Friendly Display: The product features a 4.2-inch LCD display that provides real-time operational data and system status, enhancing user monitoring and control.
- Comprehensive Protection: Equipped with extensive electronic protection functions, the system ensures safe and stable operation.
2. Features
- Advanced SPWM technology for pure sine wave output.
- Fully digitalized voltage and current double closed-loop control.
- Advanced MPPT technology with tracking efficiency no less than 99.5%.
- Four charging modes: Solar priority, Utility priority, Utility & Solar, Solar.
- LCD display for dynamic display of system running data and operating state.
- Two output modes: Battery and Utility.
- Common and advanced interfaces provided.
- Multiple LED indicators for instant operational status.
- 2P circuit breaker at the utility input end.
- Independent control of AC output with AC OUT button.
- Battery temperature compensation function.
- Extensive electronic protection functions.
3. Product Appearance and Components
Familiarize yourself with the various parts of your EPever UP3000 series inverter/charger.

| No. | Component | No. | Component |
|---|---|---|---|
| 1 | Ventilation | 6 | RTS* interface |
| 2 | Captive screw (2 pcs) | 7 | Relay interface |
| 3 | AC output terminals | 8 | Remote interface |
| 4 | Utility input terminals | 9 | Inverter/charger switch |
| 5 | Battery input terminals | 10 | PV input terminals |
*Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature of 25 °C.
4. Setup and Installation
This section provides guidance for setting up your EPever UP3000 series inverter/charger. Ensure all connections are secure and follow local electrical codes.
4.1 System Connection Diagram
The following diagram illustrates a typical system setup for the inverter/charger, integrating PV array, utility, battery, and AC loads.

Warning: Confirm the AC load power is compatible with the power of the inverter/charger. Selecting an AC load exceeding the maximum output power of the inverter/charger is prohibited.
4.2 Product Naming Rule
Understanding the product naming convention helps in identifying specific model features.

4.3 Output and Charging Modes
The inverter/charger supports various operational modes:
- Two OUTPUT modes: Utility, Battery
- Four charging modes: Solar priority, Utility priority, Utility & Solar, Solar
Note on Charging Logic:
- When the battery voltage is lower than the "Restore Auxiliary Module Charging Voltage (VAON)", the utility starts charging. When the battery voltage reaches to "Stop Auxiliary Module Charging Voltage (VAOF)", the utility stops charging.
- When the battery voltage is lower than the "Restore Auxiliary Module Charging Voltage (VAON)", the solar starts charging. When the battery voltage reaches to "Stop Auxiliary Module Charging Voltage (VAOF)", the solar stops charging.
5. Operation
This section details how to operate your inverter/charger using the front panel buttons and understanding the real-time display.
5.1 Button Operations
| Button | Operation | Instruction |
|---|---|---|
| ESC | Press the ESC button | Exit the current interface |
| Press the ESC button and hold on 5s | Clear the faults | |
| UP | Press the UP button | Setting interface: Up/Down |
| Press the UP button and hold on 5s | Setting interface: Up/Down | |
| DOWN | Press the DOWN button | Confirm the setting parameters |
| Press the DOWN button and hold on 5s | Browse interface: "Browse Parameter" over to "Set Parameter" | |
| SET | Press the SET button | Browse interface: "Browse Interface" over to "Parameter Setting Interface" |
| AC OUT | Press the AC OUT button | Inverter ON/OFF |
5.2 Real-time Interface and Icons
The LCD provides a real-time display of system status using various icons and parameters.

| Icon | Instruction | Icon | Instruction |
|---|---|---|---|
| Utility connecting | PV connecting | ||
| No Utility connecting | No PV connecting | ||
| Load ON | Load OFF | ||
| Battery capacity level 0~25% | Battery capacity level 25~50% | ||
| Battery capacity level 50~75% | Battery capacity level 75~100% |
| Item | Setting | Content |
|---|---|---|
| INPUT | Solar priority | Solar priority |
| Utility priority | Utility priority | |
| Utility & Solar | Utility & Solar | |
| Solar | Solar | |
| OUTPUT | Utility | Utility |
| Battery | Battery | |
| Load | AC output voltage | AC output voltage |
| AC output frequency | AC output frequency | |
| Battery voltage | Battery voltage | |
| Inverter current | Inverter current | |
| Battery | PV charging current | PV charging current |
| Utility charging current | Utility charging current | |
| Battery SOC | Battery SOC | |
| PV | PV voltage | PV voltage |
| PV charging power | PV charging power | |
| PV charging current | PV charging current | |
| Utility | Utility input voltage | Utility input voltage |
| Utility charging power | Utility charging power | |
| Utility charging current | Utility charging current | |
| Battery Type | GEL | GEL |
| AGM | AGM | |
| FLOOD | FLOOD | |
| USER | USER |
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter/charger.
- Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are not blocked. Use a dry cloth for cleaning; do not use liquids.
- Connection Checks: Periodically inspect all wiring connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion. Loose connections can cause overheating and damage.
- Environment: Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, moisture, and flammable materials. Maintain the recommended working environment temperature.
- Battery Health: Monitor battery voltage and health regularly, especially if using a user-defined battery type, to ensure proper charging and discharge cycles.
7. Troubleshooting and Protection Functions
The EPever UP3000 series inverter/charger is equipped with comprehensive protection functions to safeguard the system. If an issue occurs, the device will typically indicate a fault on the LCD and activate the relevant protection.
7.1 Protection Functions
- PV Over Current protection
- PV Reverse Polarity protection
- Utility input overvoltage protection
- Utility input under voltage protection
- Load Short Circuit protection
- Device overheating protection
- PV short circuit protection
- Night Reverse Charging protection
- Battery overvoltage protection
- Battery Over Discharge protection
- Load Overload protection
In case of a fault, refer to the LCD display for error codes or indicators. For persistent issues not resolved by basic checks (e.g., clearing faults via the ESC button), contact technical support.
8. Technical Specifications
Detailed specifications for the UP3000-M3322 and UP3000-M2142 models are provided below.

| Item | UP3000-M3322 | UP3000-M2142 |
|---|---|---|
| General | ||
| System battery voltage | 24VDC | 48VDC |
| Battery input voltage range | 21.6~32VDC | 43.2~64VDC |
| Inverter Output | ||
| Continuous output power | 2400W | 2400W |
| Output power (15min.) | 3000VA | 3000VA |
| Overload power (5s) | 4800VA | 4800VA |
| Max. surge power | 6000VA | 6000VA |
| Output voltage range | 220VAC±3% / 230VAC (-7%~+3%) | |
| Output frequency | 50Hz/60Hz | |
| Output wave | Pure Sine Wave | |
| Power factor | 0.8 | |
| Distortion THD | ≤3% (24V, 4V or 48V resistive load) | |
| Inverter efficiency | max 95% | |
| Utility Input | ||
| Utility input voltage range | 170VAC~275VAC | |
| Utility charge current | 30A | 15A |
| Transfer time | 20ms | |
| Solar Charging | ||
| Max. PV open circuit voltage | 100V | 150V |
| Max. PV input power | 780W | 1040W |
| PV charging current | 30A | 20A |
| Equalization voltage | 29.2V | 58.4V |
| Boost voltage | 28.8V | 57.6V |
| Float voltage | 27.6V | 55.2V |
| Tracking efficiency | ≥99.5% | |
| Charging conversion efficiency | ≥98% | |
| Temperature compensate coefficient | -3mV/°C/2V (Default) | |
| Other | ||
| No load consumption | ≤0.8A | ≤0.6A |
| Enclosure | IP30 | |
| Relative humidity | < 95% (N.C.) | |
| Working environment temperature | -20°C~50°C (100% input and output) | |
| Mechanical Parameters | ||
| Dimension | 444×300×126mm | 518×310×168mm |
| Mounting dimension | 230mm | |
| Mounting hole size | Φ8mm | |
| Weight | 9.2kg | 19.0kg |
9. User Tips
- Optimal Panel Sizing: Ensure your PV array's open circuit voltage and power are within the inverter's specified limits to maximize charging efficiency and prevent damage.
- Battery Compatibility: Always use batteries compatible with the inverter's voltage (24V or 48V) and ensure they are of sufficient capacity for your load requirements.
- Ventilation is Key: Proper airflow around the inverter is crucial to prevent overheating, especially during high load or charging periods. Do not obstruct the ventilation openings.
- Monitor Display: Regularly check the LCD display for real-time system data and any warning icons to quickly identify and address potential issues.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model and serial number available when seeking support.