EPever UP3000-M3322, UP3000-M2142, UP3000-M6322

Contents

EPever UP3000 Series MPPT Solar and Utility Charger Inverter User Manual

Models: UP3000-M3322, UP3000-M2142, UP3000-M6322

Brand: EPever

1. Introduction

The EPever UP3000 series is an advanced MPPT Solar and Utility Charger Inverter designed for efficient power management in various applications. This hybrid inverter combines solar charging, utility charging, and AC output functionalities into a single unit, offering a reliable and stable power solution.

Key technologies integrated include:

  • Optimized MPPT Tracking: The PV charging modules utilize an up-to-date optimized MPPT tracking technology to quickly identify and track the maximum power point of the PV array, maximizing solar energy harvest in real-time.
  • Advanced AC-DC Charging: AC-DC charging modules feature an advanced control algorithm for fully digitalized double closed-loop control of voltage and current, ensuring high control precision and compact design. It supports a wide range of AC input voltages and offers continuously adjustable DC charging voltage/current.
  • Pure Sine Wave DC-AC Inversion: The DC-AC inverter modules are based on a full digital and intelligent design, employing advanced SPWM technology to output a pure sine wave. It converts 24V/48VDC to 220V/230VAC, making it suitable for a wide array of AC loads including household appliances, electric tools, and commercial units.
  • User-Friendly Display: The product features a 4.2-inch LCD display that provides real-time operational data and system status, enhancing user monitoring and control.
  • Comprehensive Protection: Equipped with extensive electronic protection functions, the system ensures safe and stable operation.

2. Features

  • Advanced SPWM technology for pure sine wave output.
  • Fully digitalized voltage and current double closed-loop control.
  • Advanced MPPT technology with tracking efficiency no less than 99.5%.
  • Four charging modes: Solar priority, Utility priority, Utility & Solar, Solar.
  • LCD display for dynamic display of system running data and operating state.
  • Two output modes: Battery and Utility.
  • Common and advanced interfaces provided.
  • Multiple LED indicators for instant operational status.
  • 2P circuit breaker at the utility input end.
  • Independent control of AC output with AC OUT button.
  • Battery temperature compensation function.
  • Extensive electronic protection functions.

3. Product Appearance and Components

Familiarize yourself with the various parts of your EPever UP3000 series inverter/charger.

Diagram showing the front and bottom views of the EPever UP3000 series inverter with numbered components.
Figure 1: Product Appearance and Component Identification
Component List
No.ComponentNo.Component
1Ventilation6RTS* interface
2Captive screw (2 pcs)7Relay interface
3AC output terminals8Remote interface
4Utility input terminals9Inverter/charger switch
5Battery input terminals10PV input terminals

*Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature of 25 °C.

4. Setup and Installation

This section provides guidance for setting up your EPever UP3000 series inverter/charger. Ensure all connections are secure and follow local electrical codes.

4.1 System Connection Diagram

The following diagram illustrates a typical system setup for the inverter/charger, integrating PV array, utility, battery, and AC loads.

System connection diagram showing PV array, utility, inverter/charger, battery, and AC loads.
Figure 2: System Connection Diagram

Warning: Confirm the AC load power is compatible with the power of the inverter/charger. Selecting an AC load exceeding the maximum output power of the inverter/charger is prohibited.

4.2 Product Naming Rule

Understanding the product naming convention helps in identifying specific model features.

Diagram explaining the product naming rule for UPower series inverters, including AC output voltage, battery voltage, PV charge current, AC output power, and series name.
Figure 3: Product Naming Rule and System Modes

4.3 Output and Charging Modes

The inverter/charger supports various operational modes:

  • Two OUTPUT modes: Utility, Battery
  • Four charging modes: Solar priority, Utility priority, Utility & Solar, Solar

Note on Charging Logic:

  • When the battery voltage is lower than the "Restore Auxiliary Module Charging Voltage (VAON)", the utility starts charging. When the battery voltage reaches to "Stop Auxiliary Module Charging Voltage (VAOF)", the utility stops charging.
  • When the battery voltage is lower than the "Restore Auxiliary Module Charging Voltage (VAON)", the solar starts charging. When the battery voltage reaches to "Stop Auxiliary Module Charging Voltage (VAOF)", the solar stops charging.

5. Operation

This section details how to operate your inverter/charger using the front panel buttons and understanding the real-time display.

5.1 Button Operations

Operation Table
ButtonOperationInstruction
ESCPress the ESC buttonExit the current interface
Press the ESC button and hold on 5sClear the faults
UPPress the UP buttonSetting interface: Up/Down
Press the UP button and hold on 5sSetting interface: Up/Down
DOWNPress the DOWN buttonConfirm the setting parameters
Press the DOWN button and hold on 5sBrowse interface: "Browse Parameter" over to "Set Parameter"
SETPress the SET buttonBrowse interface: "Browse Interface" over to "Parameter Setting Interface"
AC OUTPress the AC OUT buttonInverter ON/OFF

5.2 Real-time Interface and Icons

The LCD provides a real-time display of system status using various icons and parameters.

Real-time interface display with icons and their meanings, and a table of settings.
Figure 4: Real-time Interface and Settings
Real-time Interface Icons
IconInstructionIconInstruction
Utility iconUtility connectingPV iconPV connecting
No Utility iconNo Utility connectingNo PV iconNo PV connecting
Load ON iconLoad ONLoad OFF iconLoad OFF
Battery 0-25% iconBattery capacity level 0~25%Battery 25-50% iconBattery capacity level 25~50%
Battery 50-75% iconBattery capacity level 50~75%Battery 75-100% iconBattery capacity level 75~100%
Real-time Interface Settings
ItemSettingContent
INPUTSolar prioritySolar priority
Utility priorityUtility priority
Utility & SolarUtility & Solar
SolarSolar
OUTPUTUtilityUtility
BatteryBattery
LoadAC output voltageAC output voltage
AC output frequencyAC output frequency
Battery voltageBattery voltage
Inverter currentInverter current
BatteryPV charging currentPV charging current
Utility charging currentUtility charging current
Battery SOCBattery SOC
PVPV voltagePV voltage
PV charging powerPV charging power
PV charging currentPV charging current
UtilityUtility input voltageUtility input voltage
Utility charging powerUtility charging power
Utility charging currentUtility charging current
Battery TypeGELGEL
AGMAGM
FLOODFLOOD
USERUSER

6. Maintenance

Regular maintenance ensures optimal performance and longevity of your inverter/charger.

  • Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are not blocked. Use a dry cloth for cleaning; do not use liquids.
  • Connection Checks: Periodically inspect all wiring connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion. Loose connections can cause overheating and damage.
  • Environment: Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, moisture, and flammable materials. Maintain the recommended working environment temperature.
  • Battery Health: Monitor battery voltage and health regularly, especially if using a user-defined battery type, to ensure proper charging and discharge cycles.

7. Troubleshooting and Protection Functions

The EPever UP3000 series inverter/charger is equipped with comprehensive protection functions to safeguard the system. If an issue occurs, the device will typically indicate a fault on the LCD and activate the relevant protection.

7.1 Protection Functions

  • PV Over Current protection
  • PV Reverse Polarity protection
  • Utility input overvoltage protection
  • Utility input under voltage protection
  • Load Short Circuit protection
  • Device overheating protection
  • PV short circuit protection
  • Night Reverse Charging protection
  • Battery overvoltage protection
  • Battery Over Discharge protection
  • Load Overload protection

In case of a fault, refer to the LCD display for error codes or indicators. For persistent issues not resolved by basic checks (e.g., clearing faults via the ESC button), contact technical support.

8. Technical Specifications

Detailed specifications for the UP3000-M3322 and UP3000-M2142 models are provided below.

Technical specifications table for EPever UP3000-M3322 and UP3000-M2142 models, detailing inverter output, utility input, solar charging, and mechanical parameters.
Figure 5: Technical Specifications (UP3000-M3322 & UP3000-M2142)
Key Technical Specifications
ItemUP3000-M3322UP3000-M2142
General
System battery voltage24VDC48VDC
Battery input voltage range21.6~32VDC43.2~64VDC
Inverter Output
Continuous output power2400W2400W
Output power (15min.)3000VA3000VA
Overload power (5s)4800VA4800VA
Max. surge power6000VA6000VA
Output voltage range220VAC±3% / 230VAC (-7%~+3%)
Output frequency50Hz/60Hz
Output wavePure Sine Wave
Power factor0.8
Distortion THD≤3% (24V, 4V or 48V resistive load)
Inverter efficiencymax 95%
Utility Input
Utility input voltage range170VAC~275VAC
Utility charge current30A15A
Transfer time20ms
Solar Charging
Max. PV open circuit voltage100V150V
Max. PV input power780W1040W
PV charging current30A20A
Equalization voltage29.2V58.4V
Boost voltage28.8V57.6V
Float voltage27.6V55.2V
Tracking efficiency≥99.5%
Charging conversion efficiency≥98%
Temperature compensate coefficient-3mV/°C/2V (Default)
Other
No load consumption≤0.8A≤0.6A
EnclosureIP30
Relative humidity< 95% (N.C.)
Working environment temperature-20°C~50°C (100% input and output)
Mechanical Parameters
Dimension444×300×126mm518×310×168mm
Mounting dimension230mm
Mounting hole sizeΦ8mm
Weight9.2kg19.0kg

9. User Tips

  • Optimal Panel Sizing: Ensure your PV array's open circuit voltage and power are within the inverter's specified limits to maximize charging efficiency and prevent damage.
  • Battery Compatibility: Always use batteries compatible with the inverter's voltage (24V or 48V) and ensure they are of sufficient capacity for your load requirements.
  • Ventilation is Key: Proper airflow around the inverter is crucial to prevent overheating, especially during high load or charging periods. Do not obstruct the ventilation openings.
  • Monitor Display: Regularly check the LCD display for real-time system data and any warning icons to quickly identify and address potential issues.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model and serial number available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.