EPEVER TracerANG3

Contents

EPEVER Tracer-AN G3 MPPT Solar Charge Controller User Manual

Models: Tracer1210AN G3, Tracer2210AN G3, Tracer3210AN G3, Tracer4210AN G3 (10A-40A)

1. Introduction

The EPEVER Tracer-AN G3 series charge controller utilizes advanced Maximum Power Point Tracking (MPPT) technology. This technology enables the controller to rapidly and accurately track the maximum power point (MPP) of the solar array, ensuring optimal solar energy harvesting. It can achieve up to 30% more power generation compared to traditional PWM charge controllers. This series is designed to accept a maximum open circuit voltage (Voc) of 100V, making it compatible with solar panels typically used in on-grid applications. A multi-function LCD provides clear and comprehensive display of the system's operational status.

EPEVER Tracer-AN G3 MPPT Solar Charge Controller with MT52 remote meter and WiFi module options

Image: EPEVER Tracer-AN G3 MPPT Solar Charge Controller with optional accessories.

2. Key Features

Diagram illustrating key features of the EPEVER Tracer-AN G3 MPPT Solar Charge Controller

Image: Overview of the Tracer-AN G3's main features.

  • MPPT Technology: Tracking efficiency ≥99.5% and conversion efficiency of 98% for maximized PV utilization.
  • Safety-Based Automatic Overcharge Limiting: Protects PV system from overcharging.
  • Energy-Saving Design: Ultra-quiet and low-consumption for durability.
  • Comprehensive Electronic Protection: Includes protection against over-discharge, over-temperature, overload, load short circuit, over-voltage, reverse polarity, short circuit, and reverse current.
  • Versatile Battery Support: Compatible with Flooded, Gel, Sealed, Lithium, and User-defined battery types.
  • Temperature Compensation and Self-Activation: Ensures optimal charging performance across varying temperatures.
  • APP Control & Real-time Monitoring: Features an RS485 interface with optional 4G or Wi-Fi modules for remote monitoring and control.
  • Multiple Load Modes: Offers Time Control, Light ON/OFF, and Manual Mode for flexible load management.
  • Adjustable Charging Current: Maximum charging current can be set from 1A up to the rated value.
  • Constant Voltage Output Function: Under specific conditions, the PV array can directly support the system load without requiring a battery.

3. Product Overview and Components

Diagram of EPEVER Tracer-AN G3 MPPT Solar Charge Controller components

Image: Figure 1 Product Characteristics - Labeled components of the controller.

Controller Components
No.Component
1SELECT button
2RTS* Interface
3PV Terminals
4Battery Terminals
5Load Terminals
6RS485 communication interface
7Mounting Hole Φ5mm
8ENTER button
9LCD

Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge at the default temperature setting of 25°C.

4. Setup and Installation

Follow the connection order carefully to ensure safe and proper operation of your solar charging system.

Wiring diagram for EPEVER Tracer-AN G3 MPPT Solar Charge Controller

Image: Detailed wiring diagram showing connections for PV panel, battery, DC load, and optional inverter.

Connection Order:

  1. Connect Battery First: Connect the battery to the controller's battery terminals. Ensure correct polarity.
  2. Connect DC Load: Connect your DC loads to the load terminals.
  3. Connect Solar Panel: Connect the solar PV panel to the PV terminals.
  4. Connect Inverter (Optional): If using an inverter, connect it as shown in the diagram.

Disconnection Order:

To disconnect the system, reverse the connection order:

  1. Disconnect Inverter (if applicable)
  2. Disconnect Solar Panel
  3. Disconnect DC Load
  4. Disconnect Battery Last

Supported Battery Types: The controller supports various battery types including Lead-acid batteries (Sealed, Flooded, GEL, User-defined) and Lithium-ion batteries (LiFePO4, Li(NiCoMn)O2, User-defined).

5. Operating Instructions

Load Working Modes:

The Tracer-AN G3 offers enhanced load working modes for various application scenarios.

Diagram showing different load working modes for Tracer-AN G3 controller

Image: Comparison of load working modes between Tracer-AN and Tracer-AN G3.

The Tracer-AN G3 controller provides 6 distinct load working modes:

  1. Manual Mode: Load is controlled manually via the controller's buttons.
  2. Light ON/OFF Mode: Load turns on automatically at dusk and off at dawn.
  3. Light ON/OFF + Timer Mode 1: Load turns on at dusk and stays on for a set duration (night on and day off).
  4. Light ON/OFF + Timer Mode 2: Load turns on for a set duration after dusk, then turns off until dawn (day on and night off).
  5. Real-time Control Mode: Allows for precise scheduling of load operation.
  6. Always ON Mode: Load remains continuously on.

Monitoring:

The controller features an RS485 interface for communication. Optional 4G or Wi-Fi modules can be connected to enable real-time monitoring and control via a mobile application or PC software.

Diagram showing remote monitoring of the solar charge controller via smartphone app

Image: Remote monitoring setup with optional Wi-Fi module and smartphone app.

Constant Voltage Output Function:

Under specific conditions, the PV array can directly supply power to the system load, bypassing the battery. This feature is useful when the solar input is sufficient to power the loads directly.

Diagram illustrating constant voltage output function where PV directly powers loads

Image: PV array directly powering loads without battery involvement.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your solar charge controller:

  • Cleanliness: Keep the controller clean and free from dust and debris. Ensure ventilation openings are not blocked.
  • Connections: Periodically check all wiring connections for tightness and corrosion. Loose connections can cause overheating and damage.
  • Inspection: Inspect the controller for any signs of physical damage, discoloration, or unusual odors.
  • Environment: Ensure the controller is installed in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.

7. Troubleshooting

If you encounter issues with your EPEVER Tracer-AN G3 MPPT Solar Charge Controller, consider the following general troubleshooting steps:

  • No Display/Power: Check battery connections and ensure the battery voltage is within the controller's operating range. Verify that the battery is charged.
  • No Charging: Ensure solar panels are connected correctly and receiving sufficient sunlight. Check PV voltage and current. Verify that the PV open circuit voltage does not exceed the controller's maximum input.
  • Load Not Working: Check load connections and ensure the load is not exceeding the controller's rated discharge current. Verify the selected load working mode.
  • Error Codes: If the LCD displays an error code, refer to the comprehensive manual (not provided here) for specific definitions and solutions.
  • Temperature Sensor: If the temperature sensor is damaged or short-circuited, the controller will operate at a default temperature of 25°C. Replace the sensor if necessary for accurate temperature compensation.

For detailed troubleshooting and specific error code resolutions, please consult the full product manual provided by EPEVER.

8. Specifications

ModelTracer1210AN G3Tracer2210AN G3Tracer3210AN G3Tracer4210AN G3
Battery rated voltage12/24VDC/Auto
Controller work voltage range8~31V
Rated charge current10A20A30A40A
Rated discharge current10A20A30A40A
Rated charge power130W/12V
260W/24V
260W/12V
520W/24V
390W/12V
780W/24V
520W/12V
1040W/24V
Max. conversion efficiency≤98.0%
Tracking efficiency≥99.5%
MPP voltage range(Battery Voltage+2V)~72V
Max. PV open circuit voltage100V (At minimum operating environment temperature)
92V (At 25℃ environment temperature)
Temperature compensation-3mV/℃/2V (Default)
Relative humidity≤95%, N.C.
EnclosureIP30
Communication interfaceRS485 (RJ45)
GroundingCommon Negative
Operating temperature range-25℃~+45℃ (100% input and output)
Dimensions (LxWxH) (mm)172 x 139 x 44220 x 154 x 52228 x 164 x 55252 x 180 x 63
Net weight0.57kg0.94kg1.26kg1.65kg

9. User Tips

  • Ventilation: Always ensure adequate ventilation around the controller to prevent overheating, which can impact performance and lifespan.
  • Battery Compatibility: Double-check that your battery type is correctly configured in the controller settings to ensure proper charging and prevent damage.
  • Monitoring: Utilize the optional MT52 remote meter or Wi-Fi/Bluetooth modules for real-time monitoring of your system's performance. This helps in identifying potential issues early and optimizing energy harvest.

10. Warranty and Support

EPEVER products are designed for reliability and performance. For any warranty claims, technical support, or service inquiries, please contact your authorized dealer or the manufacturer directly. Ensure you retain your proof of purchase for warranty validation.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.