EPEVER XTRA-N G3 BLE

Contents

EPEVER XTRA-N G3 MPPT Solar Charge Controller User Manual

Models: 10A, 20A, 30A, 40A (XTRA-N G3 BLE Series)

1. Introduction

Thank you for choosing the EPEVER XTRA-N G3 MPPT Solar Charge Controller. This manual provides essential information for the safe and efficient operation of your solar charge controller. The XTRA-N G3 series utilizes advanced Maximum Power Point Tracking (MPPT) technology to maximize energy harvest from your solar panels and efficiently charge various battery types. Certain models include a built-in Bluetooth module for convenient monitoring and parameter adjustment via a mobile application.

EPEVER XTRA-N G3 MPPT Solar Charge Controller with Bluetooth and APP control

Figure 1: EPEVER XTRA-N G3 MPPT Solar Charge Controller

2. Key Features

  • Advanced MPPT Technology: Tracking efficiency ≥99.5% for optimal power conversion.
  • Versatile Battery Support: Compatible with various battery types including Lithium, Gel, Sealed, and more.
  • No Battery Support: Can operate without a battery in certain configurations.
  • Built-in Bluetooth Module: Enables wireless communication for real-time monitoring and parameter modification via a dedicated mobile APP (for certain models).
  • Constant Voltage Output Function: Prevents voltage spikes and ensures stable power delivery.
  • High Protection Level: IP33 rated for protection against solid objects and water spray.
  • Energy-Saving Design: Ultra-quiet and low-consumption operation for enhanced durability.
  • Comprehensive Electronic Protection: Multiple safeguards against overcharge, over-discharge, reverse polarity, and short circuits.
  • Temperature Compensation: Automatically adjusts charging parameters based on ambient temperature.
  • Self-Activation: Intelligent system activation.
  • Multiple Load Modes: Supports Time Control, Light ON/OFF, and Manual Mode for flexible load management.
Diagram illustrating key features of the EPEVER XTRA-N G3 controller including MPPT, IP33 protection, and electronic safeguards.

Figure 2: Overview of Controller Features

3. Setup and Installation

Proper installation is crucial for the safety and performance of your solar charge controller. Please follow these guidelines carefully.

3.1 Safety Precautions

  • Ensure all connections are tight and secure to avoid loose connections that can cause sparks.
  • Always connect the battery first, then the solar panel, and finally the load. Disconnect in the reverse order.
  • Do not short-circuit the solar panel or battery terminals.
  • Install the controller in a well-ventilated area, away from direct sunlight, high temperatures, and moisture.
  • Ensure sufficient clearance around the controller for heat dissipation.

3.2 Wiring Diagram

The controller features common negative grounding. Ensure your system components are compatible with this grounding type.

Wiring diagram for EPEVER XTRA-N G3 showing connections for solar panel, battery, and load, with constant voltage output and no battery support.

Figure 3: Basic System Wiring Diagram

3.3 Connection Steps

  1. Connect the Battery: Connect the battery to the controller's battery terminals. Observe correct polarity (+ to + and - to -). The controller will power on if the battery voltage is sufficient.
  2. Connect the Solar Panel: Connect the solar panel to the controller's PV terminals. Ensure correct polarity. The controller will begin charging if the solar panel generates enough power.
  3. Connect the Load: Connect the DC load to the controller's load terminals. Ensure correct polarity. The load output can be controlled via the controller's settings or mobile app.

Important: Always connect the battery first and disconnect it last. Incorrect wiring may damage the controller or other components.

4. Operation

4.1 Display and Buttons

The controller features an LCD display and buttons for local operation. Refer to the product image for button layout (PV/+, BATT/-, LOAD/SET, O/ESC).

4.2 Mobile APP Monitoring and Control

For models with a built-in Bluetooth module, you can monitor and control the controller using the EPEVER mobile application. This allows for real-time data viewing and parameter adjustments.

Image showing the EPEVER XTRA-N G3 controller and a smartphone displaying the APP interface for parameter reading and modification.

Figure 4: APP Control for Parameter Reading and Modification

4.3 Load Working Modes

The controller supports multiple load working modes to suit various application scenarios:

  • Time Control: The load operates for a specified duration.
  • Light ON/OFF: The load turns on at dusk and off at dawn.
  • Manual Mode: The load can be manually switched on or off.
Diagram illustrating multiple load modes: Time Control, Light ON/OFF, and Manual Mode.

Figure 5: Multiple Load Modes

5. Maintenance

To ensure optimal performance and longevity of your EPEVER solar charge controller, regular maintenance is recommended:

  • Check Connections: Periodically inspect all wiring connections for tightness and corrosion.
  • Clean the Controller: Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
  • Inspect for Damage: Check for any physical damage to the casing, wires, or terminals.
  • Monitor Performance: Regularly check the system's performance via the LCD display or mobile app to ensure it's operating within expected parameters.
  • Ventilation: Ensure that the installation area remains well-ventilated and free from obstructions to airflow.

6. Troubleshooting

If you encounter issues with your controller, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Controller not powering onBattery not connected or low voltage; reverse polarity.Check battery connections and voltage. Ensure correct polarity. Charge battery if needed.
No charging from solar panelSolar panel not connected; low solar input; reverse polarity; PV open-circuit voltage too low/high.Check solar panel connections and polarity. Ensure sufficient sunlight. Verify PV voltage is within controller's operating range.
Load not workingLoad disconnected; load mode setting incorrect; battery low voltage protection; overcurrent protection.Check load connections. Adjust load mode settings. Charge battery. Reduce load if overcurrent.
Bluetooth connection issuesBluetooth module not active; APP not installed or outdated; distance too far.Ensure controller is powered. Install/update EPEVER APP. Reduce distance between device and controller.

7. Specifications

The EPEVER XTRA-N G3 series offers various models with different current ratings and PV input capabilities. Below are general specifications and specific details for common models.

7.1 General Electrical Parameters

  • Battery Rated Voltage: 12/24VDC Auto (for 10A/20A models), 12/24/36/48VDC Auto (for 30A/40A models)
  • Controller Work Voltage Range: 8~31V (for 10A/20A models), 8~62V (for 30A/40A models)
  • Grounding Type: Common negative
  • RS485 Port: 5VDC/200mA (RJ45)
  • LCD Backlight Time: Default: 60S, Range: 0~999S (0S: backlight always ON)
  • Temperature Compensation: -3mV/℃/2V (Default)
  • Discharge-circuit Voltage Drop: ≤0.23V

7.2 Model-Specific Electrical Parameters

For detailed specifications of each model, please refer to the tables below:

XTRA-N G3 BLE 30A/40A Models (12/24/36/48V Auto)

Detailed electrical parameters table for EPEVER XTRA3215N, XTRA4215N, XTRA3415N, XTRA4415N G3 BLE models, including rated charging current, PV open-circuit voltage, and charging power.

Figure 6: Specifications for XTRA3215N, XTRA4215N, XTRA3415N, XTRA4415N G3 BLE

XTRA-N G3 BLE 10A/20A Models (12/24V Auto)

Detailed electrical parameters table for EPEVER XTRA1206N, XTRA2206N, XTRA1210N, XTRA2210N, XTRA3210N, XTRA4210N G3 BLE models, including rated charging current, PV open-circuit voltage, and charging power.

Figure 7: Specifications for XTRA1206N, XTRA2206N, XTRA1210N, XTRA2210N, XTRA3210N, XTRA4210N G3 BLE

7.3 MPPT Tracking Efficiency

MPPT Technology Tracking Efficiency graph showing Current vs Voltage, with Maximum Power Point (MPP), Short-circuit current (Isc), Current at max power point (Impp), Voltage at max power point (Vmpp), and Open circuit voltage (Voc).

Figure 8: MPPT Tracking Efficiency Curve

8. Warranty and Support

EPEVER products are designed for reliability and performance. For warranty information and technical support, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for any warranty claims.

9. User Tips

  • Battery Type Selection: Always ensure the correct battery type is selected in the controller settings to prevent damage and optimize charging.
  • Wiring Polarity: Double-check all wiring polarities before applying power to avoid irreversible damage to the controller or connected devices.
  • Mobile App Utilization: Make full use of the mobile application for convenient real-time monitoring of your solar system's performance and for easy adjustment of parameters.
  • Ventilation: Ensure the controller is installed in a location with adequate airflow to prevent overheating, especially during peak operation.

© 2023 EPEVER. All rights reserved.