EPEVER XTRA-N G3 BLE Series

Contents

EPEVER XTRA-N G3 BLE Series MPPT Solar Charge Controller User Manual

Models: XTRA1206/1210/2206/2210/3210/3215/3415/4210/4215/4415N G3 and XTRA1206/1210/2206/2210/3210/3215/3415/4210/4215/4415N G3 BLE

1. Introduction

1.1 Overview

The EPEVER XTRA-N G3/XTRA-N G3 BLE series solar charge controllers are designed with advanced Maximum Power Point Tracking (MPPT) control algorithms. These controllers efficiently track the maximum power point of PV arrays to maximize energy harvest under various conditions. The XTRA-N G3 BLE series features a built-in Bluetooth module for convenient parameter reading and modification via a smartphone application.

Key features include independent voltage regulation, support for various battery types (including lithium), low self-consumption, and robust system stability through charging power/current limits and auto-reduction under high temperatures. The controllers offer IP33 ingress protection and an isolated RS485 communication port for enhanced reliability and diverse application requirements. A three-stage charging mode prolongs battery lifespan, and comprehensive electronic protections ensure system reliability and durability. These controllers are suitable for RVs, household systems, and monitoring fields.

1.2 Characteristics

  • Advanced MPPT technology with ultra-fast tracking speed, achieving up to 99.5% tracking efficiency.
  • Maximum DC/DC transfer efficiency up to 98.5%; full load efficiency up to 97.2% (for XTRA4415N G3/XTRA4415N G3 BLE 48V systems).
  • Accurate recognition and tracking of multi-peak maximum power points.
  • Wider Maximum Power Point (MPP) running voltage to optimize PV utilization.
  • Supports multiple battery types, including lithium batteries, with a stable self-activation function.
  • Battery voltage parameters can be set on the LCD.
  • Battery temperature compensation.
  • Limits charging power and current to prevent exceeding rated values.
  • Real-time energy statistics function.
  • Automatic charging power reduction for over-temperature conditions.
  • Built-in Bluetooth for EPEVER APP adjustments (XTRA-N G3 BLE series only).
  • RS485 communication interface for optional 4G or Wi-Fi modules for remote monitoring.
  • Parameters can be set via PC software, APP, or remote meter.
  • Constant voltage output function.
  • Comprehensive electronic protections.
  • Multiple load work modes.
  • Dustproof and waterproof design with IP33 enclosure.
  • Low self-consumption, typically less than 10mA.
  • Operates at full load without reduced charging power within the working temperature range.

1.3 Naming Rules

The model names indicate specific features:

  • XTRA: Product series.
  • 1/2/3/4: Rated charging & discharging current (1=10A, 2=20A, 3=30A, 4=40A).
  • 06/10/15: PV maximum open-circuit voltage (06=60V, 10=100V, 15=150V).
  • N: Common negative system.
  • G3: The 3rd generation product.
  • BLE: Built-in Bluetooth module (for XTRA-N G3 BLE series).

2. Important Safety Instructions

Please read and follow all instructions and warnings carefully before installation and operation.

2.1 General Safety Guidelines

  • No user-serviceable components are inside the controller. Do NOT disassemble or attempt to repair it.
  • Mount the controller indoors. Avoid exposure to water.
  • Install in a well-ventilated area. The heat sink can become very hot during operation.
  • Use appropriate external fast-acting fuses/breakers.
  • Disconnect all PV array connections and fuses/breakers before installation or adjustment.
  • Ensure power connections are tight to prevent excessive heating.
WARNING: Do not install the controller in humid, high salt spray, corrosive, greasy, flammable, explosive, or dusty environments.

2.2 Other Safety Instructions (FCC Compliance)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device. If interference occurs, try reorienting the receiving antenna, increasing separation, or connecting to a different circuit. Consult a dealer or experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits for an uncontrolled environment. It should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

2.3 Disclaimers

The warranty does not apply to damage caused by:

  • Improper use or inappropriate environment (e.g., humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments).
  • Actual current/voltage/power exceeding the controller's limit value.
  • Working temperature exceeding the rated range.
  • Arc, fire, explosion, or other accidents due to failure to follow instructions.
  • Unauthorized dismantling or attempted repair.
  • Force majeure.
  • Damage during transportation or handling.

3. Installation

3.1 Attentions

  • Be careful when installing batteries, especially flooded lead-acid batteries. Wear eye protection and have fresh water available.
  • Keep batteries away from metal objects to prevent short circuits.
  • Ensure good ventilation as explosive battery gases may be released during charging.
  • Do not install the controller in a sealed enclosure with vented batteries, as fumes can corrode circuits.
  • Ensure tight power connections and use cable clamps to secure wires to prevent overheating and fire.
  • The controller works with lead-acid and lithium batteries within its control scope.
  • System cables should be selected according to 5A/mm² or less current density (NFPA 70, Article 690).
  • Grounding wire size should not be less than 4mm².
  • Torque for wiring screws should not be less than 1.2N.m.

3.2 PV Array Requirements

The controller is compatible with various PV modules. The number of PV modules in series depends on the MPPT controller's open-circuit voltage (Voc) and maximum power point voltage (Vmpp). Refer to the technical specifications for detailed tables.

CAUTION: The cable length of the battery should not exceed 3 meters. The recommended cable length of the PV array should not exceed 3 meters for EN/IEC61000-6-3 compliance.

3.3 Wire Size

The wiring and installation methods must conform to national and local electrical code requirements. The PV array's short circuit current (Isc) determines the minimum PV wire size. The Isc of the PV array must not exceed the controller's maximum PV input current.

PV Wire Size Table (Max. PV input current, Max. PV wire size, Circuit breaker)

ModelMax. PV Input CurrentMax. PV Wire Size*Circuit Breaker
XTRA1206/1210N G3/BLE10A4mm²/12AWG16A/125V/2P
XTRA2206/2210N G3/BLE20A6mm²/10AWG32A/125V/2P
XTRA3210/3215/3415N G3/BLE30A10mm²/8AWG40A/125V/2P
XTRA4210/4215/4415N G3/BLE40A16mm²/6AWG63A/125V/2P

*These are the maximum wire sizes that will fit the controller terminals.

CAUTION: When PV modules are connected in series, the open-circuit voltage of the PV array must not exceed 46V (XTRA**06N G3/BLE), 92V (XTRA**10N G3/BLE), 138V (XTRA**15N G3/BLE) at 25°C.

Battery and Load Wire Size Table (Rated charge/discharge current, Battery wire size, Load wire size, Circuit breaker)

ModelRated Charge CurrentRated Discharge CurrentBattery Wire SizeLoad Wire SizeCircuit Breaker
XTRA1206/1210N G3/BLE10A10A4mm²/12AWG4mm²/12AWG16A/125V/2P
XTRA2206/2210N G3/BLE20A20A6mm²/10AWG6mm²/10AWG32A/125V/2P
XTRA3210/3215/3415N G3/BLE30A30A10mm²/8AWG10mm²/8AWG40A/125V/2P
XTRA4210/4215/4415N G3/BLE40A40A16mm²/6AWG16mm²/6AWG63A/125V/2P

3.4 Mounting

Step 1: Determine Installation Location and Heat-Dissipation Space

The controller should be installed in a location with sufficient airflow. Ensure a minimum clearance of 150 mm from the upper and lower edges for natural thermal convection.

Mounting clearance diagram for EPEVER solar charge controller
Figure 2-1: Mounting clearance for the controller, showing 150mm space above and below.
CAUTION: If the controller is installed in an enclosed box, ensure reliable heat dissipation.

Step 2: Connect the System

Connect the system in the order of 1) battery, 2) load, 3) PV array. Disconnect in the reverse order.

Schematic wiring diagram for EPEVER solar charge controller in Battery Mode
Figure 1.4: Connection diagram for Battery Mode, showing PV array, controller, battery, and load connections with breakers and fuse.
Schematic wiring diagram for EPEVER solar charge controller in No-Battery Mode
Figure 1.4: Connection diagram for No-Battery Mode, showing PV array, controller, and inverter connections with breakers.
CAUTION: When wiring, do not connect the circuit breaker or fast-acting fuse initially. Ensure correct electrode polarity. A fast-acting fuse (1.25 to 2 times rated current) must be installed on the battery side, no more than 150 mm from the battery. If an inverter is used, connect it directly to the battery, not the load side of the controller.

Step 3: Grounding

XTRA-N G3/BLE series controllers are common-negative. All negative terminals can be grounded simultaneously, or any one can be grounded. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.

CAUTION: A common-negative controller is recommended for common-negative systems (e.g., motorhomes). The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in a common-negative system.

Step 4: Connect Accessories

  • Remote Temperature Sensor Cable (Optional): Connect the sensor cable (Model: RT-MF58R47K3.81A or RTS300R47K3.81A) to the controller's interface and place the other end near the battery. If not connected, the controller defaults to 25°C for charging/discharging without temperature compensation.
  • RS485 Communication: Refer to Chapter 4 for settings.

Step 5: Power On the Controller

Connect the battery's fast-acting fuse to power the controller. Check the battery indicator (should be green). Then connect the fast-acting fuse and circuit breaker of the load and PV array. The system will operate in preprogrammed mode.

CAUTION: If the controller does not operate properly or the battery indicator shows an abnormality, refer to the Troubleshooting section.

4. Display Units and Operation

EPEVER MPPT Solar Charge Controller display unit
Figure 3.1: EPEVER MPPT Solar Charge Controller with display and buttons.

4.1 Indicator Lights

The controller features various indicator lights (PV, Battery, Load) that show the system's status:

IndicatorColorStatusInstruction
PVGreenOn SolidPV charges battery with low current
GreenOFFNo sunlight, Connection error, Low PV voltage
GreenSlowly Flashing (1Hz)Normal charging
GreenFast Flashing (4Hz)PV Over voltage
BatteryGreenOn SolidNormal
GreenSlowly Flashing (1Hz)Full
GreenFast Flashing (4Hz)Overvoltage
OrangeOn SolidUnder voltage
RedOn SolidOver discharged
LoadYellowOn SolidLoad ON
YellowOFFLoad OFF
PV&BATT LED fast flashingController Overheating, System voltage error

4.2 Button Functions

The controller has several buttons for navigation and settings:

ButtonActionFunction
PV/+PressPV browsing interface, Setting data +
Press and hold 5sSetting LCD cycle time, enable/disable COM port
BATT/-PressBATT browsing interface, Cursor displacement during setting
Press and hold 5sSetting battery type, battery capacity level, temperature unit
LOAD/-PressController load browsing interface, Setting data
Press and hold 5sSetting load working mode
SETPressEnter setting interface, Switch setting interface to browsing, Confirm setting parameter
O/ESCPressExit setting interface

4.3 Display Information

The LCD displays various parameters. Ensure viewing angle is within 90° for clear visibility.

  • PV Parameters: Voltage, Current, Power, Generated Energy.
  • Battery Parameters: Voltage, Current, Temperature, Battery capacity level.
  • Load Parameters: Voltage, Current, Power, Consumed energy, Load working mode-Timer1/Timer2.

5. Parameters Setting

5.1 Battery Parameters

The controller supports various battery types. For default types, voltage parameters cannot be modified. Select "USE" type for custom settings.

Supported Battery Types:

  • Sealed (default)
  • Gel
  • Flooded
  • LiFePO4 (4S/8S/15S/16S)
  • Li(NiCoMn)O2 (3S/6S/7S/13S/14S)
  • User (customizable)
WARNING: When the default battery type is selected, the battery voltage parameters cannot be modified. To change these parameters, select the "USE" type.

Local Setting: Navigate through the display using buttons to select battery type, set capacity, and temperature units. Refer to the manual for detailed button sequences.

Remote Setting: Battery parameters can be set via PC software, external WiFi module, external Bluetooth module, or built-in Bluetooth (for BLE models). Connect the controller via RS485 port (USB to RS485 cable for PC, or wireless modules). Use the EPEVER APP for convenient adjustments.

Diagram showing EPEVER controller connected to PC via USB to RS485 cable for remote setting
Figure 4.1.3: Remote setting via PC software.
Diagram showing EPEVER controller connected to smartphone via external WiFi module for APP setting
Figure 4.1.3: Remote setting via external WiFi module.

Battery Voltage Parameters (12V/25°C conditions):

Battery ParametersSealedGELFLDUser Defined
Over voltage disconnect voltage16.0V16.0V16.0V9~17V
Charging limit voltage15.0V15.0V15.0V9~15.5V
Float charging voltage13.8V13.8V13.8V9~15.5V
Low voltage disconnect voltage11.1V11.1V11.1V9~15.5V

Note: Double values for 24V system, multiply by 4 for 48V system.

5.2 Load Modes

The controller supports multiple load modes, configurable via LCD or remote methods.

  • Manual Control (default): Load ON/OFF controlled by button or remote commands (PC software, APP, remote meter).
  • Light ON/OFF: Load turns on at dusk and off at dawn.
  • Light ON + Timer: Load turns on at dusk and stays on for a set duration.
  • Time Control: Load ON/OFF time set by real-time clock.
Diagram illustrating multiple load modes: Time Control, Light ON/OFF, and Manual Mode
Figure 4.2.1: Multiple Load Modes available on the controller.
CAUTION: When selecting Light ON/OFF, Test mode, or Manual mode, only Timer 1 can be set; Timer 2 is disabled.

6. Protection Features

The EPEVER XTRA-N G3/BLE series controllers incorporate comprehensive electronic protections:

ProtectionInstructions
PV Over Current/PowerIf PV charging current or power exceeds rated values, charging will be limited to rated values. WARNING: PV open-circuit voltage must not exceed maximum PV open-circuit voltage, or controller may be damaged.
PV Short CircuitController will not be damaged if short-circuited when not charging. WARNING: Do not short-circuit PV array during charging.
PV Reverse PolarityController will not be damaged and can operate normally after polarity correction. CAUTION: Controller is damaged if PV array is connected reversely and actual operating power exceeds 1.5 times rated charging power.
Night Reverse ChargingPrevents battery discharge to PV module at night.
Battery Reverse PolarityBattery can be reversely connected when PV is disconnected or reversely connected. Correct wiring to resume work. WARNING: Controller will be damaged if PV connection is correct and battery connection is reversed.
Battery Over VoltageController stops charging when battery voltage exceeds Over Voltage Disconnect Voltage.
Battery Over DischargeController stops battery discharging when battery voltage is lower than Low Voltage Disconnect Voltage.
Battery Over-heatingController stops working if temperature exceeds 65°C, resumes below 55°C.
Lithium Battery Low TemperatureController stops charging/discharging if temperature is below Low Temperature Protection Threshold (LTPT), resumes above LTPT. (LTPT is 0°C by default, settable 10 ~ -40°C).
Load Short CircuitController cuts off output if load short-circuited (≥ 4 times rated load current). Resets after 5 attempts or manual intervention.
OverloadController cuts off output if load overloading (≥ 1.02 times rated load current). Resets after 5 attempts or manual intervention.
Controller Over-heatingController stops working if internal temperature exceeds 85°C, resumes below 75°C. Reduced charging power mode activates at 81°C.
TVS High Voltage TransientsInternal circuitry includes TVS for surge protection. For areas with frequent lightning, an external surge arrester is recommended.

7. Troubleshooting

This section provides common faults and their solutions:

Possible ReasonsFaultsTroubleshooting
PV array disconnectionCharging LED indicator off during daytime when sunshine falls on PV modules properly.Confirm that PV wire connections are correct and tight.
Battery voltage is lower than 8VThe wire connection is correct, and the controller is not working.Check battery voltage. At least 8V to activate the controller.
Battery over voltageGreen charging indicator fast flashes. Battery level shows full, battery frame and fault icon blink.Check if battery voltage is higher than OVD (over voltage disconnect voltage), and disconnect the PV.
Battery over-dischargedRed charging indicator is ON solid. Battery level shows empty, battery frame and fault icon blink.When battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover.
Battery OverheatingRed battery indicator slow flashes. Battery frame and fault icon blink.Controller automatically turns off. Resumes when temperature declines to below 55°C.
System voltage errorPV and BATT indicators fast flash.Check if battery voltage matches system voltage level. Change battery or modify system voltage level.
Load Short CircuitNo load output. LCD blinks "E001." Load and fault icons blink.Check load connection, cancel fault. Restart controller. Wait for one night-day cycle.
Load OverloadNo load output. LCD blinks "E002." Load and fault icons blink.Reduce electric equipment. Restart controller. Wait for one night-day cycle.

8. Maintenance

Perform the following inspections and maintenance tasks at least twice yearly for optimal performance:

  • Ensure the controller is firmly installed in a clean and dry environment.
  • Check for any obstructions to airflow around the controller and clean dirt/fragments from the heat sink.
  • Inspect all naked wires for insulation damage (sun exposure, wear, insects, etc.) and repair/replace if necessary.
  • Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
  • Verify LED indicators are consistent with expected status. Take corrective action for any errors.
  • Confirm all system components are tightly and correctly grounded.
  • Check all terminals for corrosion, insulation damage, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
  • Clean dirt, nesting insects, and corrosion.
  • Check the lightning arrester's condition and replace if necessary to protect the controller and other equipment.
WARNING: Risk of electric shock! Ensure all power is turned off before performing any maintenance operations.

9. Technical Specifications

9.1 Electrical Parameters

ItemXTRA1206N G3/BLEXTRA2206N G3/BLEXTRA1210N G3/BLEXTRA2210N G3/BLEXTRA3210N G3/BLEXTRA4210N G3/BLE
Battery Rated Voltage12/24VDC★ Auto
Rated Charging Current10A20A10A20A30A40A
Rated Discharging Current10A20A10A20A30A40A
Controller Work Voltage Range8~31V
PV Maximum Open-circuit Voltage60V (min. operating temp), 46V (25°C)100V (min. operating temp), 92V (25°C)
MPPT Voltage Range(Battery voltage+2V)~36V(Battery voltage+2V)~72V
Rated Charging Power130W/12V, 260W/24V260W/12V, 520W/24V130W/12V, 260W/24V260W/12V, 520W/24V390W/12V, 780W/24V520W/12V, 1040W/24V
Maximum Conversion Efficiency97.9%98.3%98.2%98.3%98.6%98.6%
Maximum Load Efficiency97%96.7%96.2%96.4%96.6%96.5%
Static Losses (Enable com. port)≤10mA(12V), ≤7mA(24V)≤10mA(12V), ≤7mA(24V)≤15mA(12V), ≤9mA(24V)≤15mA(12V), ≤9mA(24V)≤15mA(12V), ≤9mA(24V)≤15mA(12V), ≤9mA(24V)
Static Losses (Disable com. port)≤8mA(12V), ≤5mA(24V)≤8mA(12V), ≤5mA(24V)≤8mA(12V), ≤6mA(24V)≤8mA(12V), ≤6mA(24V)≤8mA(12V), ≤5mA(24V)≤8mA(12V), ≤5mA(24V)
Discharge-circuit Voltage Drop≤0.23V
Temperature Compensation-3mV/°C/2V (Default)
Grounding TypeCommon negative
RS485 Port5VDC/200mA(RJ45)
LCD Backlight TimeDefault: 60S, Range: 0~999S (0S: backlight is ON all the time)

9.2 Mechanical Parameters

ItemXTRA1206N G3/BLEXTRA2206N G3/BLEXTRA1210N G3/BLEXTRA2210N G3/BLEXTRA3210N G3/BLEXTRA4210N G3/BLE
Dimension (L x W x H)175×143×48mm217×158×56.5mm175×143×48mm217×158×56.5mm230×165×63mm255×185×67.8mm
Mounting Size (L x W)120×134mm160×149mm120×134mm160×149mm173×156mm200×176mm
Mounting Hole SizeΦ5mm
Terminal12AWG(4mm²)6AWG(16mm²)12AWG(4mm²)6AWG(16mm²)6AWG(16mm²)6AWG(16mm²)
Recommended Wire Size12AWG(4mm²)10AWG(6mm²)12AWG(4mm²)10AWG(6mm²)8AWG(10mm²)6AWG(16mm²)
Net Weight0.58kg0.97kg0.59kg0.97kg1.30kg1.72kg

9.3 Environmental Parameters

ItemXTRA1206/2206/1210/2210/3210/4210N G3/BLEXTRA3215/4215/3415/4415N G3/BLE
Work Temperature Range-25°C~+50°C-25°C~+45°C
Storage Temperature Range-20°C~+70°C
Relative Humidity≤95%, N.C.
EnclosureIP33 (3-protection against solid objects: protected against solids objects over 2.5mm. 3-protected against sprays to 60° from the vertical.)
Pollution DegreePD2

10. Conversion Efficiency Curves

The following graphs illustrate the conversion efficiency of various models under standard test conditions (Illumination Intensity: 1000W/m², Temperature: 25°C).

10.1 XTRA1206N G3/BLE

13V Conversion Efficiency Curves for XTRA1206N G3/BLE
13V Conversion Efficiency Curves (MPPT: 17V, 34V) / Nominal System Voltage (13V)
26V Conversion Efficiency Curves for XTRA1206N G3/BLE
26V Conversion Efficiency Curves (MPPT: 34V, 45V) / Nominal System Voltage (26V)

(Additional efficiency curves for other models are available in the full PDF manual.)

11. User Tips

  • Optimal Performance: For best results, ensure your PV array voltage is well within the controller's MPPT voltage range. This maximizes power harvest.
  • Battery Compatibility: Always select the correct battery type in the controller settings. If using a custom lithium battery, use the "USE" setting and configure parameters carefully via the APP or PC software.
  • Ventilation is Key: Proper airflow around the controller is crucial to prevent overheating, especially in warmer climates or during high power operation.
  • Regular Checks: Periodically inspect wiring connections for tightness and signs of corrosion to maintain system efficiency and safety.
  • Remote Monitoring: Utilize the built-in Bluetooth (BLE models) or external communication modules to monitor your system's performance and adjust settings conveniently from your smartphone or PC.

12. Warranty and Support

For detailed warranty information and technical support, please refer to the official EPEVER website or contact your local distributor. The full user manual in PDF format is available for download:

Download User Manual (PDF)