1. Introduction
The EPEVER Tracer AN series MPPT solar charge controller is an advanced, efficient, and multi-functional device designed for off-grid solar systems. It features Maximum Power Point Tracking (MPPT) technology to maximize energy harvest from solar panels and ensure optimal battery charging. This manual provides detailed instructions for the safe and efficient setup, operation, and maintenance of your Tracer AN series controller.
2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Keep this manual for future reference.
- Ensure all wiring is correctly polarized and securely connected to prevent damage to the controller or other components.
- Always connect the battery first, then the solar panel, and finally the load. Disconnect in the reverse order.
- Do not short-circuit the solar panel or battery terminals.
- Install the controller in a well-ventilated area, away from flammable materials and direct sunlight.
- The controller generates heat during operation; ensure adequate airflow.
- Only qualified personnel should perform installation and maintenance.
- Wear appropriate personal protective equipment (PPE) when working with electrical systems.
3. Product Overview
The Tracer AN series controllers are equipped with advanced features for reliable solar power management.
3.1 Key Features
- Advanced MPPT technology with high tracking efficiency (up to 99.5%).
- Peak conversion efficiency up to 98%.
- Accurate tracking of multiple-peaks maximum power point.
- Compatible with lead-acid (Sealed, Gel, Flooded) and lithium-ion batteries (LiFePO4, Li(NiCoMn)O2, User-defined).
- Multiple load work modes for flexible application.
- RS485 communication bus interface for external devices (MT50, PC, Bluetooth, WiFi).
- Real-time energy statistics function.
- Extensive electronic protection functions, including overcharging, over-discharging, PV over current/power, battery reverse polarity, and more.
- Full-load operation without any drop in capacity within the range of working environment temperature.
3.2 Components

The controller features an LCD display for monitoring and parameter setting, along with various terminals for connections:
- LCD Display: Shows system status and parameters.
- SELECT Button: Navigates through menus.
- ENTER Button: Confirms selections or enters settings.
- Mounting Holes: For securing the controller.
- Remote Temp. Sensor Terminal: Connects the optional temperature sensor.
- Solar Panel Terminal: Connects to the solar array.
- Battery Terminal: Connects to the battery bank.
- Load Terminal: Connects to DC loads.
- COM (RJ45 Communication Port): For connecting accessories like the MT50 remote meter, Bluetooth adapter, WiFi adapter, or PC communication cable.
4. Setup
4.1 Unpacking and Inspection
Upon receiving your EPEVER Tracer AN series controller, carefully unpack all components and inspect for any damage. The package typically includes:
- EPEVER Tracer AN Series MPPT Solar Charge Controller
- MT50 Remote Meter (optional, depending on purchase)
- Remote Temperature Sensor (RTS) cable
- USB to RS485 Communication Cable (optional)
- Mounting screws and wall plugs

4.2 Mounting the Controller
Choose a suitable location for mounting the controller, ensuring:
- Good ventilation and heat dissipation.
- Protection from direct sunlight, high temperatures, and moisture.
- Sufficient space around the controller for wiring and maintenance.
- Mark the positions of the mounting holes on the wall or mounting surface.
- Drill holes and insert wall plugs if necessary.
- Secure the controller using the provided screws.
4.3 Wiring Connections
IMPORTANT: Follow the connection and disconnection order precisely to prevent damage.

Connection Order:
- Connect Battery (1): Connect the battery to the battery terminals (+ and -) on the controller. Ensure correct polarity. The controller will power on.
- Connect Solar Panel (2): Connect the solar panel to the PV terminals (+ and -) on the controller. Ensure correct polarity.
- Connect DC Load (3): Connect the DC load to the load terminals (+ and -) on the controller. Ensure correct polarity.
- Connect Inverter (Optional, 4): If using an inverter, connect it to the battery terminals or a dedicated inverter connection point in your system, ensuring proper fusing and protection.
Disconnection Order:
- Disconnect Inverter (if applicable).
- Disconnect DC Load.
- Disconnect Solar Panel.
- Disconnect Battery.
4.4 Connecting Accessories
4.4.1 MT50 Remote Meter
The MT50 remote meter provides a convenient way to monitor system status and modify parameters from a distance.

Connect the MT50 to the controller's RJ45 communication port using an Ethernet cable.
4.4.2 Remote Temperature Sensor (RTS)
The RTS cable ensures accurate battery temperature compensation for optimal charging.

Plug the RTS cable into the dedicated Remote Temp. Sensor terminal on the controller and place the sensor near the battery.
4.4.3 PC Communication Cable (CC-USB-RS485-150U)
For advanced monitoring and parameter configuration via PC software.

Connect one end to the controller's RJ45 port and the other to your computer's USB port. Install the necessary drivers and software provided by EPEVER.
5. Operating Instructions
5.1 Initial Power-Up
After completing all wiring connections in the correct order, the controller's LCD display will light up, indicating successful power-up. It will typically show the battery voltage and charging status.
5.2 LCD Display and Buttons
The LCD provides real-time data and allows for parameter adjustments.
- SELECT Button: Press to cycle through different display screens (e.g., battery voltage, solar panel voltage, charging current, load current, temperature).
- ENTER Button: Press and hold to enter parameter setting mode. Once in setting mode, use SELECT to change values and ENTER to confirm.
5.3 Parameter Settings
The controller allows customization of various parameters, including battery type, charge voltage limits, load control modes, and more. Refer to the detailed parameter setting section in the full EPEVER manual for specific instructions on each setting.
5.4 Load Control
The controller offers several load work modes to manage the DC output:
- Manual Control: Turn the load on/off manually via the controller or MT50.
- Light Control: Load turns on at dusk and off at dawn.
- Light Control + Timer: Load turns on at dusk and stays on for a set duration.
- Dual-Timer Control: Allows for two separate timer periods.
These modes can be configured through the controller's interface or connected accessories.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your solar charge controller.
- Check Connections: Periodically inspect all wiring connections for tightness and corrosion. Loose connections can cause overheating and damage.
- Clean Terminals: Keep terminals clean and free of dust or debris.
- Inspect for Damage: Check the controller for any physical damage, cracks, or signs of overheating.
- Ventilation: Ensure the installation area remains well-ventilated and free from obstructions that could impede airflow.
- Software Updates: Check the EPEVER website for any firmware updates for your controller model.
- Battery Maintenance: Follow the battery manufacturer's recommendations for maintenance, as proper battery care is crucial for system performance.
7. Troubleshooting
The Tracer AN series controllers include various protection functions to ensure safe operation. If an issue arises, check the following:

| Problem | Possible Cause | Solution |
|---|---|---|
| Controller not powering on | Battery not connected or low voltage; reverse polarity. | Check battery connections and voltage. Ensure correct polarity. |
| No charging current | Solar panel not connected; insufficient sunlight; PV short circuit; PV reverse polarity. | Check solar panel connections and ensure adequate sunlight. Verify PV polarity. |
| Load not working | Load short circuit; load over-current; battery low voltage disconnect. | Check load connections and current draw. Ensure battery voltage is above LVD. |
| Controller overheating | Poor ventilation; excessive ambient temperature; overloaded system. | Improve ventilation. Reduce load or solar input if possible. |
| Battery over-discharge | Excessive load; incorrect LVD setting. | Reduce load or adjust LVD setting. Consider increasing battery capacity. |
If the problem persists, contact EPEVER technical support.
8. Specifications

| Attribute | Value |
|---|---|
| Brand Name | EPever |
| Model Numbers | Tracer 4210AN, 3210AN, 2210AN, 1210AN |
| Maximum Current | 10A, 20A, 30A, 40A (depending on model) |
| Application | Charger Controller, Voltage Controller, Solar System Controller, Solar Working Station, Lighting Controller |
| Is Smart Device | Yes |
| Certification | CE |
| Working Environment Temperature | -25℃ ~ +50℃ (100% input and output) |
| Storage Temperature Range | -20℃ ~ +70℃ |
| Relative Humidity | ≤95%, N.C. |
| Enclosure | IP30 |
9. Warranty and Support
EPEVER products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.
10. User Tips
- When purchasing, ensure to check the specific model number (e.g., Tracer1210AN, Tracer2210AN, Tracer3210AN, Tracer4210AN) and desired accessories like the MT50 remote meter, as different configurations and colors (e.g., black MT50) may be available.
- Always verify the latest model information and compatibility with your existing solar system components.
- For optimal performance, ensure the remote temperature sensor is placed as close to the battery as possible to provide accurate temperature readings for charging compensation.