EPEVER IP1500

Contents

EPEVER IPower Pure Sine Wave Inverter 1500W User Manual

Models: IP1500-11, IP1500-12, IP1500-21, IP1500-22

Brand: EPEVER

1. Introduction and Overview

The EPEVER IPower series is a pure sine wave inverter designed to convert 12Vdc or 24Vdc input into 110/120Vac or 220/230Vac output. This inverter is characterized by its concise outline, compact size, high reliability, high efficiency, and ease of installation and operation. It is suitable for various applications, including household emergency lighting systems, vehicle-mounted power systems, and small field power supplies.

EPEVER IPower 1500W Pure Sine Wave Inverter
Figure 1: EPEVER IPower 1500W Pure Sine Wave Inverter

2. Safety Instructions

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure proper grounding of the inverter to prevent electrical hazards.
  • Do not open the inverter casing. There are no user-serviceable parts inside. Refer all servicing to qualified personnel.
  • Keep the inverter away from water, moisture, and flammable materials.
  • Ensure adequate ventilation around the inverter to prevent overheating. Do not block ventilation openings.
  • Verify that the DC input voltage matches the inverter's rated input voltage (12V or 24V) and that the AC output voltage and frequency are correctly configured for your appliances.
  • Always disconnect the DC input power before making or breaking connections to the inverter.
  • Avoid connecting loads that exceed the inverter's rated continuous power output.

3. Product Features

  • Complete isolation-type inverter technology for enhanced safety.
  • Advanced SPWM technology for pure sine wave output, suitable for sensitive electronics.
  • Dynamic current loop control technology ensures reliable inverter operation.
  • Wide DC input voltage range.
  • Low output harmonic distortion (THD≤5%).
  • Optional output voltage and frequency settings (110/120VAC, 50/60Hz).
  • High conversion efficiency, typically 93% to 95%.
  • USB output: 5VDC/1A (available on specific models).
  • RS485 communication port (available on specific models).
  • Extensive electronic protection features.

4. Package Contents

Upon opening the package, please verify that all items are present and undamaged:

  • EPEVER IPower Pure Sine Wave Inverter
  • User Manual
  • DC Input Cables (Red for Positive, Black for Negative)
  • Mounting Hardware (screws, washers)
  • Certificate (if included)
EPEVER IPower Inverter Package Contents
Figure 2: Inverter and included accessories

5. Installation and Setup

5.1 Physical Installation

  • Choose a dry, well-ventilated location, away from direct sunlight, heat sources, and flammable gases.
  • Mount the inverter securely using the provided mounting hardware. Ensure the mounting surface can support the weight of the inverter.
  • Allow sufficient clearance around the inverter for proper airflow and cooling.

5.2 Electrical Connections

Refer to the diagrams below for proper connection of DC input, AC output, and grounding.

EPEVER IPower Inverter DC Input Terminals
Figure 3: Rear view showing DC Input terminals (+ and -) and cooling fans.
EPEVER IPower Inverter AC Output Terminals
Figure 4: Front panel with AC output terminal block, USB, RS485, and switches.
EPEVER IPower Inverter Grounding Terminal
Figure 5: Close-up of the grounding terminal on the inverter chassis.
  1. Grounding: Connect the grounding terminal (marked with ⏚) on the inverter chassis to an earth ground using a suitable gauge wire.
  2. DC Input: Connect the positive (+) terminal of your battery bank to the red DC input terminal on the inverter. Connect the negative (-) terminal of your battery bank to the black DC input terminal on the inverter. Ensure connections are tight and secure.
  3. AC Output: Connect your AC loads to the AC output terminals or outlet socket. Note that the AC output type (terminal block or standard outlet) may vary based on available stock.

5.3 Mode Switch Configuration

The inverter features mode switches to select the desired AC output frequency and voltage. These switches are typically located on the front panel.

EPEVER IPower Inverter Mode Switches Diagram
Figure 6: Diagram of mode switches for frequency and voltage selection.
  • Frequency Switch (Switch No. 1):
    • ON: Output frequency is 60Hz.
    • OFF: Output frequency is 50Hz.
  • Voltage Switch (Switch No. 2):
    • ON: Output voltage is 230Vac/220Vac.
    • OFF: Output voltage is 110Vac/120Vac.

Ensure these switches are set correctly before powering on the inverter to match your regional power standards and connected appliances.

6. Operation

6.1 Turning On/Off

After completing all electrical connections and setting the mode switches, you can power on the inverter:

  1. Ensure all AC loads are disconnected or turned off.
  2. Flip the ON/OFF switch on the inverter to the "ON" position.
  3. The green working indicator should illuminate, indicating normal operation.
  4. You can now connect and turn on your AC loads.
  5. To turn off, first disconnect or turn off all AC loads, then flip the ON/OFF switch to the "OFF" position.
EPEVER IPower Inverter Front Panel Controls
Figure 7: Front panel showing ON/OFF switch, indicators, and AC output.

6.2 Indicators

  • Working Indicator (Green): Illuminates when the inverter is operating normally and providing AC output.
  • Fault Indicator (Red): Illuminates or flashes to indicate a fault condition. Refer to the Troubleshooting section for details.

6.3 USB Output (if applicable)

Some models are equipped with a 5VDC/1A USB output port for charging small electronic devices. Simply connect your device's USB cable to this port.

6.4 RS485 Communication Port (if applicable)

Certain models include an RS485 communication port, allowing for remote monitoring and control with compatible EPEVER accessories or systems. Consult the specific documentation for RS485 communication if your model includes this feature.

7. Troubleshooting

The inverter is equipped with various protection mechanisms. The red fault indicator will signal an issue. Refer to the table below for common protection conditions and their recovery methods.

EPEVER IPower Inverter Protection and Recovery Table
Figure 8: Protection and Recovery Table
Protection and Recovery Guide
Protection and Recovery Condition iPower-12 iPower-22 iPower-42 Phenomenon
Over voltage protection and recover Input Voltage Ui Ui > 16V Ui > 32V Ui > 64V Output is OFF
Green indicator fast flashing
Buzzer sounds
Ui ≤ 14.5V Ui ≤ 29V Ui ≤ 58V Green indicator on solid
The output is on
Low voltage protection and recover Input Voltage Ui Ui < 10.8V Ui < 21.6V Ui < 43.2V Output is OFF
Green indicator slowly flashing
Buzzer sounds
Ui ≥ 12.5V Ui ≥ 25V Ui ≥ 50V Green indicator on solid
The output is on
Over temp. protection and recover Tem (T) Heat sink T > 80°C or Internal T > 60°C Inverter turns OFF
Heat sink T ≤ 70°C and Internal T ≤ 50°C Inverter turns ON
Overload protection and recover Output power S
Rated power Pe
S > 1.2Pe Output is OFF after 15min
Red indicator slowly flashing
Buzzer sounds
S > 1.5Pe Output is OFF after 1min
Red indicator slowly flashing
Buzzer sounds
S > 1.8Pe Output is OFF after 10s
Red indicator slowly flashing
Buzzer sounds
S > 2Pe (Rated input voltage) Output is OFF after 5s
Red indicator slowly flashing
Buzzer sounds
Output is OFF immediately
Red indicator fast flashing
Buzzer sounds
Load short circuit protection Output is OFF immediately
Red indicator fast flashing
Buzzer sounds

Note: When output overload protection or load short circuit protection occurs, the inverter has a three-time auto-recovery output function. The first time delay is 5s, the second time delay is 10s, and the third time delay is 15s.

8. Technical Specifications

The following table details the technical specifications for the EPEVER IPower 1500W series inverters.

EPEVER IPower Inverter Technical Specifications Table
Figure 9: Technical Specifications for IPower 1500W models.
EPEVER IPower 1500W Series Technical Specifications
Parameter IP1500-11 IP1500-12 IP1500-21 IP1500-22
Input Rated Voltage 12VDC 24VDC
Input Voltage Range 10.8~16VDC 21.6~32VDC
Input Surge Voltage <20V <40V
No-load current <1.0A <0.6A
Output Voltage 110VAC (±5%)
120VAC (-7%~+5%)
220VAC (±5%)
230VAC (-7%~+5%)
110VAC (±5%)
120VAC (-7%~+5%)
220VAC (±5%)
230VAC (-7%~+5%)
Output Continuous Power 1200W
Output Power 15 min. 1500W
Instantaneous impact power 2400W
Output way Single Phase
Output Wave Pure sine wave
Output Frequency 50/60Hz (±0.2%)
Distortion THD THD≤5% (Resistive load)
Max. Efficiency 93% 94%
Max. USB Output 5VDC/1A
Working environment temperature -20°C ~ +45°C
Storage temperature range -35°C ~ +70°C
Humidity range ≤95% (N.C.)
Enclosure IP20
Altitude <5000m (Derating to operate according to IEC62040 at a height exceeding 1000 m)
Binding post Φ10mm
Overall dimension 326.12×231.5×98.5mm 284.7×231.5×98.5mm
Mounting dimension 208×220mm 163×220mm
Mounting hole size Φ5.5mm
Net weight 3.90kg

9. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your inverter:

  • Cleaning: Keep the inverter's exterior clean and free from dust and debris. Use a dry cloth for cleaning. Do not use liquids or solvents.
  • Ventilation: Periodically check that the ventilation openings are not blocked. Ensure cooling fans are operating correctly.
  • Connections: Regularly inspect all electrical connections (DC input, AC output, and grounding) to ensure they are tight and free from corrosion. Loose connections can cause overheating and poor performance.
  • Environment: Ensure the operating environment remains within the specified temperature and humidity ranges.

10. User Tips

  • Battery Sizing: Ensure your battery bank is adequately sized for your power needs. A larger battery capacity will allow for longer operation times.
  • Cable Sizing: Use appropriate gauge DC cables to minimize voltage drop, especially for longer runs. Undersized cables can lead to efficiency loss and overheating.
  • Load Management: Avoid consistently running the inverter at its maximum continuous power. It's good practice to keep the average load below 80% of the inverter's continuous rating to prolong its lifespan.
  • Monitoring: If your model supports RS485 communication, consider using a compatible monitoring device to keep track of input voltage, output power, and other parameters.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact the authorized EPEVER dealer or the seller from whom you purchased the inverter. Please have your model number and purchase date available when contacting support.