1. Introduction and Overview
The EPEVER IPower series is a pure sine wave inverter designed to convert 12Vdc or 24Vdc input into 110/120Vac or 220/230Vac output. This inverter is characterized by its concise outline, compact size, high reliability, high efficiency, and ease of installation and operation. It is suitable for various applications, including household emergency lighting systems, vehicle-mounted power systems, and small field power supplies.
2. Safety Instructions
Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure proper grounding of the inverter to prevent electrical hazards.
- Do not open the inverter casing. There are no user-serviceable parts inside. Refer all servicing to qualified personnel.
- Keep the inverter away from water, moisture, and flammable materials.
- Ensure adequate ventilation around the inverter to prevent overheating. Do not block ventilation openings.
- Verify that the DC input voltage matches the inverter's rated input voltage (12V or 24V) and that the AC output voltage and frequency are correctly configured for your appliances.
- Always disconnect the DC input power before making or breaking connections to the inverter.
- Avoid connecting loads that exceed the inverter's rated continuous power output.
3. Product Features
- Complete isolation-type inverter technology for enhanced safety.
- Advanced SPWM technology for pure sine wave output, suitable for sensitive electronics.
- Dynamic current loop control technology ensures reliable inverter operation.
- Wide DC input voltage range.
- Low output harmonic distortion (THD≤5%).
- Optional output voltage and frequency settings (110/120VAC, 50/60Hz).
- High conversion efficiency, typically 93% to 95%.
- USB output: 5VDC/1A (available on specific models).
- RS485 communication port (available on specific models).
- Extensive electronic protection features.
4. Package Contents
Upon opening the package, please verify that all items are present and undamaged:
- EPEVER IPower Pure Sine Wave Inverter
- User Manual
- DC Input Cables (Red for Positive, Black for Negative)
- Mounting Hardware (screws, washers)
- Certificate (if included)
5. Installation and Setup
5.1 Physical Installation
- Choose a dry, well-ventilated location, away from direct sunlight, heat sources, and flammable gases.
- Mount the inverter securely using the provided mounting hardware. Ensure the mounting surface can support the weight of the inverter.
- Allow sufficient clearance around the inverter for proper airflow and cooling.
5.2 Electrical Connections
Refer to the diagrams below for proper connection of DC input, AC output, and grounding.
- Grounding: Connect the grounding terminal (marked with ⏚) on the inverter chassis to an earth ground using a suitable gauge wire.
- DC Input: Connect the positive (+) terminal of your battery bank to the red DC input terminal on the inverter. Connect the negative (-) terminal of your battery bank to the black DC input terminal on the inverter. Ensure connections are tight and secure.
- AC Output: Connect your AC loads to the AC output terminals or outlet socket. Note that the AC output type (terminal block or standard outlet) may vary based on available stock.
5.3 Mode Switch Configuration
The inverter features mode switches to select the desired AC output frequency and voltage. These switches are typically located on the front panel.
- Frequency Switch (Switch No. 1):
- ON: Output frequency is 60Hz.
- OFF: Output frequency is 50Hz.
- Voltage Switch (Switch No. 2):
- ON: Output voltage is 230Vac/220Vac.
- OFF: Output voltage is 110Vac/120Vac.
Ensure these switches are set correctly before powering on the inverter to match your regional power standards and connected appliances.
6. Operation
6.1 Turning On/Off
After completing all electrical connections and setting the mode switches, you can power on the inverter:
- Ensure all AC loads are disconnected or turned off.
- Flip the ON/OFF switch on the inverter to the "ON" position.
- The green working indicator should illuminate, indicating normal operation.
- You can now connect and turn on your AC loads.
- To turn off, first disconnect or turn off all AC loads, then flip the ON/OFF switch to the "OFF" position.
6.2 Indicators
- Working Indicator (Green): Illuminates when the inverter is operating normally and providing AC output.
- Fault Indicator (Red): Illuminates or flashes to indicate a fault condition. Refer to the Troubleshooting section for details.
6.3 USB Output (if applicable)
Some models are equipped with a 5VDC/1A USB output port for charging small electronic devices. Simply connect your device's USB cable to this port.
6.4 RS485 Communication Port (if applicable)
Certain models include an RS485 communication port, allowing for remote monitoring and control with compatible EPEVER accessories or systems. Consult the specific documentation for RS485 communication if your model includes this feature.
7. Troubleshooting
The inverter is equipped with various protection mechanisms. The red fault indicator will signal an issue. Refer to the table below for common protection conditions and their recovery methods.
| Protection and Recovery | Condition | iPower-12 | iPower-22 | iPower-42 | Phenomenon |
|---|---|---|---|---|---|
| Over voltage protection and recover | Input Voltage Ui | Ui > 16V | Ui > 32V | Ui > 64V | Output is OFF Green indicator fast flashing Buzzer sounds |
| Ui ≤ 14.5V | Ui ≤ 29V | Ui ≤ 58V | Green indicator on solid The output is on |
||
| Low voltage protection and recover | Input Voltage Ui | Ui < 10.8V | Ui < 21.6V | Ui < 43.2V | Output is OFF Green indicator slowly flashing Buzzer sounds |
| Ui ≥ 12.5V | Ui ≥ 25V | Ui ≥ 50V | Green indicator on solid The output is on |
||
| Over temp. protection and recover | Tem (T) | Heat sink T > 80°C or Internal T > 60°C | Inverter turns OFF | ||
| Heat sink T ≤ 70°C and Internal T ≤ 50°C | Inverter turns ON | ||||
| Overload protection and recover | Output power S Rated power Pe |
S > 1.2Pe | Output is OFF after 15min Red indicator slowly flashing Buzzer sounds |
||
| S > 1.5Pe | Output is OFF after 1min Red indicator slowly flashing Buzzer sounds |
||||
| S > 1.8Pe | Output is OFF after 10s Red indicator slowly flashing Buzzer sounds |
||||
| S > 2Pe (Rated input voltage) | Output is OFF after 5s Red indicator slowly flashing Buzzer sounds |
||||
| Output is OFF immediately Red indicator fast flashing Buzzer sounds |
|||||
| Load short circuit protection | Output is OFF immediately Red indicator fast flashing Buzzer sounds |
||||
Note: When output overload protection or load short circuit protection occurs, the inverter has a three-time auto-recovery output function. The first time delay is 5s, the second time delay is 10s, and the third time delay is 15s.
8. Technical Specifications
The following table details the technical specifications for the EPEVER IPower 1500W series inverters.
| Parameter | IP1500-11 | IP1500-12 | IP1500-21 | IP1500-22 |
|---|---|---|---|---|
| Input Rated Voltage | 12VDC | 24VDC | ||
| Input Voltage Range | 10.8~16VDC | 21.6~32VDC | ||
| Input Surge Voltage | <20V | <40V | ||
| No-load current | <1.0A | <0.6A | ||
| Output Voltage | 110VAC (±5%) 120VAC (-7%~+5%) |
220VAC (±5%) 230VAC (-7%~+5%) |
110VAC (±5%) 120VAC (-7%~+5%) |
220VAC (±5%) 230VAC (-7%~+5%) |
| Output Continuous Power | 1200W | |||
| Output Power 15 min. | 1500W | |||
| Instantaneous impact power | 2400W | |||
| Output way | Single Phase | |||
| Output Wave | Pure sine wave | |||
| Output Frequency | 50/60Hz (±0.2%) | |||
| Distortion THD | THD≤5% (Resistive load) | |||
| Max. Efficiency | 93% | 94% | ||
| Max. USB Output | 5VDC/1A | |||
| Working environment temperature | -20°C ~ +45°C | |||
| Storage temperature range | -35°C ~ +70°C | |||
| Humidity range | ≤95% (N.C.) | |||
| Enclosure | IP20 | |||
| Altitude | <5000m (Derating to operate according to IEC62040 at a height exceeding 1000 m) | |||
| Binding post | Φ10mm | |||
| Overall dimension | 326.12×231.5×98.5mm | 284.7×231.5×98.5mm | ||
| Mounting dimension | 208×220mm | 163×220mm | ||
| Mounting hole size | Φ5.5mm | |||
| Net weight | 3.90kg | |||
9. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter:
- Cleaning: Keep the inverter's exterior clean and free from dust and debris. Use a dry cloth for cleaning. Do not use liquids or solvents.
- Ventilation: Periodically check that the ventilation openings are not blocked. Ensure cooling fans are operating correctly.
- Connections: Regularly inspect all electrical connections (DC input, AC output, and grounding) to ensure they are tight and free from corrosion. Loose connections can cause overheating and poor performance.
- Environment: Ensure the operating environment remains within the specified temperature and humidity ranges.
10. User Tips
- Battery Sizing: Ensure your battery bank is adequately sized for your power needs. A larger battery capacity will allow for longer operation times.
- Cable Sizing: Use appropriate gauge DC cables to minimize voltage drop, especially for longer runs. Undersized cables can lead to efficiency loss and overheating.
- Load Management: Avoid consistently running the inverter at its maximum continuous power. It's good practice to keep the average load below 80% of the inverter's continuous rating to prolong its lifespan.
- Monitoring: If your model supports RS485 communication, consider using a compatible monitoring device to keep track of input voltage, output power, and other parameters.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact the authorized EPEVER dealer or the seller from whom you purchased the inverter. Please have your model number and purchase date available when contacting support.