1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your York Triple Inverter Mini Split Air Conditioner. Please read this manual thoroughly before installation and use, and keep it for future reference. This air conditioner is designed to provide optimal comfort and energy efficiency for your living or office space.

2. Product Overview
2.1 Key Features
- Triple Inverter Technology: Ensures high energy efficiency and stable performance.
- Efficient Cooling/Heating: Provides rapid and consistent temperature control.
- Modern, Compact Design: Sleek black finish (for selected models) that blends seamlessly with various interiors.
- 4-Way Swing: Distributes air evenly throughout the room for enhanced comfort.
- Activated Carbon Filter: Improves indoor air quality by removing odors and pollutants.
- Golden Fin: Corrosion-resistant coating on condenser and evaporator for extended lifespan.
- Hidden Air Outlet Gap: Contributes to the unit's aesthetic appeal.
- WiFi Connectivity: Allows for remote control and monitoring via a smart device (if supported by specific model).
- Remote Control: Features 4/5 operation modes, sleep mode, on/off timers, and turbo cool settings with a large LCD screen.
- Frost Wash Function: Automatic cleaning of the indoor unit's coil to maintain efficiency and air quality.
- Silent Operation: Engineered for quiet performance, with indoor machine noise below 23dB.
- Greater Durability: Robust construction designed for longevity.

2.2 Components Included
The standard package for the 12000 BTU unit typically includes:
- Indoor Unit (1)
- Outdoor Unit (1)
- Indoor Unit Mounting Bracket (1)
- Copper Pipe (approx. 3 meters)
- Electrical Cable (approx. 3 meters)
- Drain Pipe (1)
- Remote Control (1)
- User Manual (1)
Additional installation accessories may include:
- Outdoor Unit Wall Bracket
- Insulation Pipe
- Neoprene Putty to Seal Holes
- Plastic Pipe Wrap
- Electrical Wire (additional)
- Drain Joint & Seal
- Anchors & Screws
- Anti-Vibration Rubber Pads

3. Specifications
| Attribute | Specification (12000 BTU Model) |
|---|---|
| Model Number | YHE12YMEXCO-X |
| Cooling Capacity | 12000 BTU/h |
| Refrigerant | R410a |
| Type | Split Wall Mounted Air Conditioner, Inverter (Cooling/Heating) |
| Voltage | 220V~ (AC Power Source) |
| Power (W) | 1W (Standby), 2600W (Cooling Capacity) |
| Indoor Machine Noise | <23dB |
| Air Conditioning Power | 1HP |
| Energy Efficiency Rating | Class A+++, Grade 1 |
| Compressor | GMCC - Toshiba |
| Operating Language | English |
| Application | Room (Household, Commercial, Hotel) |
| App-Controlled | No (for this specific model, check product details for WiFi models) |
| High-concerned chemical | None |

4. Setup and Installation
Installation of a mini split air conditioner requires specialized tools and knowledge due to the handling of refrigerants and electrical connections. It is highly recommended that installation be performed by a qualified and certified HVAC technician.
4.1 Pre-Installation Checklist
- Ensure the installation area for both indoor and outdoor units is structurally sound and can support the weight.
- Verify that the electrical supply meets the unit's requirements (220V~).
- Confirm proper drainage for the indoor unit.
- Unpack all components and check for any damage.
4.2 Installation Steps (Overview)
A detailed installation guide is included in the product package. The following is a general overview:
- Mount the Indoor Unit: Secure the indoor unit mounting plate to the wall.
- Drill Wall Hole: Create a hole for refrigerant piping, drain hose, and electrical cable.
- Connect Piping: Connect the copper refrigerant pipes and drain hose to the indoor unit.
- Mount the Outdoor Unit: Secure the outdoor unit in a well-ventilated area, ensuring proper clearance.
- Connect Electrical Wiring: Connect the electrical cables between the indoor and outdoor units, and to the main power supply.
- Vacuum and Charge: Evacuate the refrigerant lines to remove air and moisture, then release the refrigerant.
- Test Run: Perform a test run to ensure proper operation and check for leaks.

5. Operating Instructions
Your York Triple Inverter Air Conditioner is operated primarily via the included remote control. Ensure the remote control has fresh batteries installed.

5.1 Remote Control Functions
- ON/OFF Button: Powers the unit on or off.
- MODE Button: Cycles through operation modes (Cool, Heat, Fan, Dry, Auto).
- TEMP +/- Buttons: Adjusts the desired temperature.
- SPEED Button: Adjusts fan speed (Auto, Low, Medium, High).
- SWING (L/R & U/D) Buttons: Controls the horizontal and vertical airflow direction.
- TIMER Button: Sets the auto-on or auto-off timer.
- SLEEP Button: Activates sleep mode for quiet operation and energy saving during sleep.
- TURBO Button: Initiates rapid cooling or heating for quick comfort.
- MENU/OK Buttons: For navigating and confirming settings (if applicable for advanced features).
5.2 Operation Modes
- Cool Mode: For cooling the room.
- Heat Mode: For heating the room (if applicable for your model).
- Fan Mode: Circulates air without cooling or heating.
- Dry Mode: Dehumidifies the room.
- Auto Mode: Automatically selects the appropriate mode based on the room temperature.
5.3 WiFi and Voice Control (If Applicable)
Some models may offer WiFi connectivity and voice control. Refer to the specific instructions provided with your unit for pairing with smart devices and setting up voice commands.
6. Maintenance
Regular maintenance ensures optimal performance, energy efficiency, and longevity of your air conditioner.
6.1 Air Filter Cleaning
The air filter should be cleaned every two weeks or more frequently depending on usage and air quality. To clean:
- Open the front panel of the indoor unit.
- Remove the air filters.
- Wash the filters with lukewarm water and a mild detergent.
- Rinse thoroughly and allow them to dry completely in a shaded area before reinstalling.
6.2 Frost Wash Function
Your unit features a Frost Wash function that automatically cleans the indoor unit's heat exchanger. This helps to remove dust and bacteria, maintaining clean air and efficient operation. Consult your specific manual for how to activate or schedule this feature.
6.3 Outdoor Unit Maintenance
- Keep the area around the outdoor unit clear of obstructions (leaves, debris, etc.) to ensure proper airflow.
- Periodically clean the outdoor unit's coils with a soft brush or vacuum cleaner.
- Ensure the drain hose is not blocked and water can flow freely.
6.4 Professional Servicing
It is recommended to have your air conditioner professionally serviced at least once a year by a qualified technician. This includes checking refrigerant levels, electrical connections, and overall system performance.
7. Troubleshooting
Before contacting customer support, please refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power, remote control batteries dead | Check power supply, replace remote control batteries. |
| Insufficient cooling/heating | Dirty air filter, blocked outdoor unit, wrong mode selected, doors/windows open | Clean air filter, clear outdoor unit, select correct mode, close doors/windows. |
| Unusual noise | Loose parts, foreign object in fan, unit not level | Check for loose parts, inspect fan, ensure unit is level. If noise persists, contact support. |
| Water leakage from indoor unit | Blocked drain hose, improper installation | Check and clear drain hose. If problem persists, professional re-installation may be required. |
If the problem persists after attempting these solutions, please contact qualified service personnel.
8. User Tips
- Maximize Energy Savings: Utilize the Triple Inverter technology by setting your desired temperature and letting the unit maintain it. Avoid frequently turning the unit on and off.
- Enjoy Quiet Comfort: The indoor unit is engineered for quiet operation (below 23dB), making it ideal for bedrooms and offices.
- Regular Filter Cleaning: Cleaning your air filters regularly significantly improves air quality and maintains the unit's efficiency.
- Proper Sizing: The 12000 BTU unit is generally suitable for rooms up to 500 square feet, depending on insulation and ceiling height. Ensure your unit is appropriately sized for your space for optimal performance.
9. Warranty and Support
9.1 Warranty Information
Your York Triple Inverter Air Conditioner comes with the following warranty:
- 1 Year Warranty: On parts.
- 5 Years Warranty: On the compressor.
Please retain your proof of purchase for warranty claims. The warranty covers manufacturing defects and does not cover damage caused by improper installation, misuse, or lack of maintenance.
9.2 Customer Support
For technical assistance, warranty claims, or service inquiries, please contact your authorized York dealer or the seller's customer service. When contacting support, please have your model number (YHE12YMEXCO-X) and proof of purchase readily available.
- After-sales Service Provided: Free spare parts (subject to warranty terms).