1. Introduction and Overview
The EPEVER Tracer-BP series solar charge controller utilizes advanced Maximum Power Point Tracking (MPPT) technology to enhance system charging efficiency and reduce overall system cost. These controllers are compatible with various battery types, including sealed, gel, flooded, and lithium batteries. Users can monitor and adjust operational status and parameters. They are suitable for a wide range of applications such as solar home systems, traffic signals, solar street lights, and solar garden lamps.
2. Safety Information
Please read all instructions carefully before installation and pay close attention to the following safety guidelines:
- DO NOT disassemble or attempt to repair the controller.
- Install external fast-acting fuses or breakers as required.
- Disconnect the solar module and fast-acting fuses/breakers near the battery before installing or moving the controller.
- Power connections must remain tight to avoid excessive heating from loose connections.
- Only batteries that comply with the controller's parameters can be charged.
- Battery connections can be wired to a single battery or a bank of batteries.
- Risk of electric shock: The PV and load may produce high voltages when the controller is running.
- WARNING: The controller may be damaged if the PV input experiences a short circuit on a high-power system.
- WARNING: The controller will be damaged if the PV array has straight polarity and its actual operating power is 1.5 times greater than the rated charge power.
- WARNING: The controller will be damaged if the PV connection is correct, but the battery connection is reversed.
- Do not install this product in humid, salt spray, corrosive, greasy, flammable, explosive, or dusty environments.
3. Product Features
- Utilizes high-quality components from ST, IR, and Infineon for extended product lifespan.
- Designed for a wider working environment temperature range.
- Compatible with both lead-acid and lithium batteries.
- Features lithium battery self-activating and low-temperature protection functions.
- Achieves a maximum conversion efficiency of 98%.
- Advanced Maximum Power Point Tracking (MPPT) technology with tracking efficiency no less than 99%.
- Provides ultra-fast tracking speed and guaranteed tracking efficiency.
- Accurately recognizes and tracks multiple power points.
- Includes PV power limitation function.
- Allows monitoring and parameter setting via Mobile APP and PC Monitor setting software with RS485 communication interface.
- Employs standard Modbus communication protocol for RS485 bus connections, ensuring better compatibility.
- Supports connection to IoT (Internet of Things) modules and Cloud Server monitoring software for remote monitoring of multi-machine systems.
- The RS485 connector can provide power supply.
- Features an aluminum housing for enhanced cooling.
- Provides real-time energy statistics function.
- IP68 waterproof degree for durability.
4. Setup and Installation
4.1. Wiring the Controller
Follow the connection sequence carefully to ensure proper and safe installation. Pay close attention to the positive (+) and negative (-) terminals.
- Connect components to the controller in the sequence: Load > Battery > PV. Do not insert fast-acting fuses or turn on breakers during installation. When disconnecting the system, reverse this order.
- After powering the controller, the battery LED indicator on the controller should flash green. If it does not, refer to the Troubleshooting section.
- Connect a fast-acting fuse in series through the battery positive (+) in the circuit. The battery fast-acting fuse must be 1.25 to 2 times the rated current. The installed distance is within 150mm.

4.2. WiFi Adapter Connection and Cloud Function
The EPEVER WiFi 2.4G RJ45 D adapter allows real-time transmission of operational data from your solar controller to the EPEVER cloud server via a local 2.4G WiFi network. This enables remote monitoring and parameter programming via the EPEVER server platform and mobile APP.


WARNING:
- The WIFI adapter is not compatible with the LS-B series.
- If the WIFI adapter is installed in a metal-confined space, signal transmission may be affected.
Scenario 1: With a Local 2.4G WiFi Network

- Turn on the WiFi switch on your mobile phone.
- Log in to the APP and click the '+' icon to add a new gateway.
- Select the gateway model.
- Input the gateway data (Gateway SN is the 22-digit number of the gateway WiFi name) and click 'Next Step' to enter the device adding page.
- After adding the device, click 'Next Step' to enter the above page.
- Input the local WiFi password and click 'Next Step'.
- Click 'Go to set up Wi-Fi' to connect to the gateway WiFi (HN_EPSN_xxxxxx, password: 12345678). Return to the APP after connection, and click 'Next Step'.
- After the gateway is successfully connected, connect the phone to local WiFi or 4G that can access the Internet. You can then monitor the device through the APP.
Scenario 2: Without a Local 2.4G WiFi Network

- Log in to the APP and click 'My > Collect Data'. Select all products and click 'Synchronize data' to download data.
- After all data is downloaded, return to the APP. Click 'Home > Offline'.
- Select module type (WiFi).
- Turn on the phone WiFi switch and connect the phone to the gateway WiFi (HN_EPSN_xxxxxx, password: 12345678).
- Return to the APP and click 'Equipment>Add equipment'>'Gateway SN' is the 22-digit number of the gateway WiFi name). Click 'Confirm' to add the device.
- On the 'Device List' page, click the gateway SN to enter the device's real-time monitoring page.
5. Operation
5.1. LED Indicators
The controller features PV (Green) and BATT (Orange/Red) LED indicators to show operational status:
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| PV | Green | On Solid | PV connection normal but low voltage (irradiance), no charging |
| Slowly Flashing (1Hz) | In charging | ||
| Fast Flashing (4Hz) | PV overvoltage | ||
| OFF | No PV voltage (night time) or PV connection problem | ||
| BATT | Orange | On Solid | Battery is normal |
| Slowly Flashing (1Hz) | Battery charges full | ||
| Fast Flashing (4Hz) | Battery overvoltage | ||
| Red | On Solid | Battery under voltage | |
| Fast Flashing (4Hz) | Battery over-discharged | ||
| Flashing (1Hz) | Lithium battery low temperature | ||
| Flashing (1Hz) | System voltage error* |
*When the battery type is a lithium battery, the controller does not recognize the system voltage automatically.
5.2. Load Working Mode
- Manual Mode (Default ON): The load is controlled manually.
- Light ON/OFF: The load turns on/off based on light levels.
- Turn-On voltage (Adjustable): 5V (12V system), delay 10min.
- Turn-Off voltage (Adjustable): 6V (12V system), delay 10min.
- Note: For 24V systems, multiply voltages by 2.
- Light ON + Timer: Combines light control with a timer for load operation.
- Real-time Control: Control the load ON/OFF time by setting a real-time clock.
CAUTION:
- In Light ON/OFF and Light ON+Timer modes, the load is turned on after a 10-minute delay.
5.3. Load Self-Test Function
The load automatically turns ON for 10 seconds after the controller is powered on. After this initial 10-second period, the controller reverts to its set working mode.
6. Protection Features
- PV Over Current: The controller limits the battery charging current to its maximum rated current. An oversized solar array will not operate at peak power.
- PV Short Circuit: If the PV input is short-circuited on a low-power system, the controller will stop charging. Clear the short circuit to resume normal operation.
- PV Reverse Polarity: The controller offers complete protection against reverse PV polarity if the battery is positively connected and the PV's open-circuit voltage is lower than 85V (for Tracer26/39/5210BP models).
- Battery Reverse Polarity: Provides complete protection against reverse battery polarity.
- Battery Over Voltage: The controller stops charging when the battery voltage reaches the set Over Voltage Disconnect Voltage to prevent overcharging.
- Battery Over Discharge: The controller stops discharging when the battery voltage reaches the Low Voltage Disconnect Voltage to prevent over-discharging.
- Battery Overheating: If the environment temperature exceeds 65°C (detected by the external temperature sensor), the controller will stop working and resume below 55°C.
- Lithium Battery Low Temperature: If the temperature sensor detects a temperature below the low-temperature value, charging/discharging of the lithium battery will stop. It resumes when the temperature rises above the low-temperature value.
- Load Overload: If the load current exceeds 1.05 times the maximum rated load current, the controller will disconnect the load. Reduce the load and restart the controller.
- Load Short Circuit: The load will be switched off if a short circuit (24 times rated current) occurs. The controller will attempt to reconnect the load 5 times with increasing delays (5s, 10s, 15s, 20s, 25s). If the short circuit persists, the user must manually clear the fault or wait for a night-day cycle (night time > 3 hours).
- Temperature Sensor Break Down: If the temperature sensor is short-circuited or damaged, the controller will charge/discharge at a default temperature of 25°C.
- High Voltage Transients: The controller is protected against small high voltage transients. For lightning-prone areas, additional external suppression is recommended.
7. Troubleshooting
If you encounter issues with your EPEVER Tracer-BP series controller, refer to the table below for common problems and solutions:
| Fault | Possible Reasons | Troubleshooting |
|---|---|---|
| LED Charging indicator turns off during daytime when sunshine is present | PV array disconnection | Confirm that PV and battery wire connections are correct and tight. |
| No LED indicator | Battery voltage may be less than 8.5V | Measure battery voltage with a multi-meter. Minimum 8.5V is required to start the controller. |
| Battery LED indicator green fast Flashing | Battery over voltage | Check if the battery voltage is higher than OVD (Over Voltage Disconnect), and disconnect the PV. |
| Battery LED indicator red | Battery over-discharged | When the battery voltage is restored to or above the LVR (Low Voltage Reconnect Voltage) point, the load will recover. |
| Battery LED indicator red flashing | Battery Overheating | The controller will automatically turn the system off. It will resume once the temperature declines below 50°C. |
| Load is not output | Load Overload | 1. Reduce the number of electric equipment. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
| Load Short Circuit | 1. Check carefully load connections, clear the fault. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
Note: For overload or short circuit, the load has a 5-time auto-recovery output function, with each time delayed by 5s, 10s, 15s, 20s, and 25s respectively.
8. Specifications
| Item | Model | Tracer2606BP | Tracer3906BP | Tracer5206BP | Tracer2610BP | Tracer3910BP | Tracer5210BP | Tracer7810BP |
|---|---|---|---|---|---|---|---|---|
| Nominal system voltage | 12/24VDC Auto (Lithium battery cannot automatically identify system voltage) | |||||||
| Battery input voltage range | 8.5~32VDC | |||||||
| Rated charge/discharge current | 10A | 15A | 20A | 10A | 15A | 20A | 30A | |
| Rated charge power | 130W/12V; 260W/24V | 200W/12V; 400W/24V | 260W/12V; 520W/24V | 130W/12V; 260W/24V | 200W/12V; 400W/24V | 260W/12V; 520W/24V | 390W/12V; 780W/24V | |
| Max. PV open circuit voltage | 60V (at minimum operating environment temperature); 46V (at 25°C environment temperature) | 100V (at minimum operating environment temperature); 92V (at 25°C environment temperature) | ||||||
| MPP Voltage range | (Battery voltage+2V)~36V | (Battery voltage+2V)~72V | ||||||
| Battery Type | Lead-acid battery: Sealed (Default) / Gel / Flooded/User; Lithium battery: LiFePO4/ Li-NiCoMn/User | |||||||
| Lead-acid | Equalize Charging Voltage | Sealed: 14.6V, Gel: No, Flooded: 14.8V, User: 9-17V (×2/24V) | ||||||
| Boost Charging Voltage | Sealed: 14.4V, Gel: 14.2V, Flooded: 14.6V, User: 9-17V (×2/24V) | |||||||
| Float Charging Voltage | Sealed/Gel/Flooded: 13.8V, User: 9-17V (×2/24V) | |||||||
| Low Voltage | Low Voltage Reconnect Voltage | Sealed/Gel/Flooded: 12.6V, User: 9-17V (×2/24V) | ||||||
| Low Voltage Disconnect Voltage | Sealed/Gel/Flooded: 11.1V, User: 9-17V (×2/24V) | |||||||
| Boost Charging Voltage | LiFePO4: 14.5V, Li-NiCoMn: 12.5V, User: 9-17V (×2/24V) | |||||||
| Lithium | Low Voltage Reconnect Voltage | LiFePO4: 12.8V, Li-NiCoMn: 10.5V, User: 9-17V (×2/24V) | ||||||
| Low Voltage Disconnect Voltage | LiFePO4: 11.1V, Li-NiCoMn: 9.3V, User: 9-17V (×2/24V) | |||||||
| Self-consumption | ≤13mA/12V; ≤11.5mA/24V | |||||||
| Temperature compensation coefficient | -3mV/°C/2V (Lithium battery don't have temperature compensation coefficient) | |||||||
| Communication | RS485 | |||||||
| Environment Temperature | -40°C~+60°C | -40°C~+50°C | ||||||
| Enclosure | IP68 | |||||||
| Overall dimension | 124×89×30mm | 150×93.5×32.7mm | 153×105×52.1mm | 124×89×30mm | 150×93.5×32.7mm | 153×105×52.1mm | 153.3×105×52.1mm | |
| Mounting hole size | Ø3.5mm | |||||||
| Mounting size | 88×76mm | 120×83mm | 120×94mm | 88×76mm | 120×83mm | 120×94mm | 120×94mm | |
| Power cable | 14AWG (2.5mm²) | 12AWG (4mm²) | 10AWG (6mm²) | 14AWG (2.5mm²) | 12AWG (4mm²) | 10AWG (6mm²) | 10AWG (6mm²) | |
| Net weight | 0.54kg | 0.74kg | 1.20kg | 0.54kg | 0.74kg | 1.20kg | 1.26kg | |
9. User Tips
- Always ensure all wiring connections are secure and follow the correct polarity to prevent damage to the controller and connected devices.
- Regularly check your battery voltage and overall system performance, especially if using the mobile app or PC software for monitoring.
- For optimal charging efficiency, verify that your solar panel's open-circuit voltage and maximum power point voltage are within the specified ranges for your controller model.
- When using the WiFi adapter, consider its placement to ensure strong signal transmission, especially avoiding metal-confined spaces.
- If you experience frequent load disconnections, check for potential overloads or short circuits in your load wiring.
10. Warranty and Support
10.1. Disclaimer
This warranty does not apply under the following conditions:
- Damage resulting from improper use or use in an unsuitable environment.
- If PV or load current, voltage, or power exceeds the rated value of the controller.
- If the controller's working temperature exceeds the specified limit.
- User disassembly or attempted repair of the controller without prior authorization.
- Damage to the controller due to natural elements such as lightning.
- Damage incurred during transportation and shipment.
10.2. Additional Resources
For more detailed information, including comprehensive guides and software, please refer to the official user manual PDF: EPEVER Tracer-BP Series User Manual (PDF).
You can also find PC software and mobile APP (Android: Solar Station Monitor, iPhone: Charge Controller(Li) via APP Store EPEVER--EP-01) for monitoring and parameter setting on the EPEVER website: www.epever.com.