1. Introduction and Overview
The OPEN OBV2-63 is a sophisticated three-phase adjustable over and under voltage protector with integrated over-current protection and monitoring relays. Designed to safeguard electrical equipment from voltage fluctuations and excessive current, this device offers comprehensive protection features including over-voltage, under-voltage, over-current, asymmetry, and phase sequence protection, along with automatic time-adjustable recovery. It provides real-time display of voltage and current for each phase (L1, L2, L3).

Figure 1: Front view of the OPEN OBV2-63 protector.
2. Product Features
- Over-voltage Protection: Adjustable upper voltage limit to prevent damage from high voltage.
- Under-voltage Protection: Adjustable lower voltage limit to protect against low voltage conditions.
- Over-current Protection: Adjustable current limit to prevent overload damage.
- Asymmetry Protection: Detects and protects against unbalanced phase voltages.
- Phase Sequence Protection: Ensures correct phase rotation for sensitive equipment.
- Automatic Time Adjustable Recovery: Configurable recovery time after a fault event.
- Real-time Display: Digital display of current voltage and current for each phase (L1, L2, L3).
- Flame Retardant Shell: Constructed with PC flame-retardant material for enhanced safety.
- High-Quality Terminals: Designed for good anti-corrosion, rust prevention, and conductivity.
- DIN Rail Buckle: Easy to install and operate on standard DIN rails.
- Adjustable Parameters: Current, over-current protection times, and action reset delay times are all adjustable.

Figure 2: Key product features.

Figure 3: Overload automatic power off features.
3. Specifications
| Parameter | Value |
|---|---|
| Model Number | OBV2-63 |
| Rated Voltage | AC220V |
| Operation Voltage Range | AC140V-300V |
| Rated Frequency | 50/60Hz |
| Hysteresis | Over voltage and asymmetry 5V, Under voltage 5V |
| Asymmetry Trip Delay | 0.5s |
| Voltage Measurement Accuracy | ≤1% (over the whole range) |
| Rated Insulation Voltage | 660V |
| Output Contact | 1NO |
| Electrical Life | 10^5 |
| Mechanical Life | 10^6 |
| Protection Degree | IP20 |
| Pollution Degree | 3 |
| Operation Temperature | -5℃~40℃ |
| Humidity | ≤50%RH (no condensation) |
| Storage Temperature | -25℃~55℃ |
| Origin | Mainland China |
| Certification | CE, FCC |
| Parameter | Setting Range | Factory Setting | Step | Function Description |
|---|---|---|---|---|
| Power-on delay time | 1-500s | 10s | 1s | The time needed for power-on when power recovers. |
| Over-voltage protection value | 230-300V | 270V | 1V | When the voltage is higher than the set value, the protector will cut off the line. |
| Over-voltage recovery value | 220-295V | 265V | 1V | When the voltage is lower than the set value, the protector will automatically reset, and the set value must be less than the over-voltage protection value by more than 5V. |
| Over-voltage recovery delay time | 1-500s | 30s | 1s | After over-voltage recovery, the time needed for automatic reset. |
| Over-voltage protection action time | 0.1-30s | 1.0s | 0.1s | When the voltage is higher than the set value, the time needed for protection action. |
| Under-voltage protection value | 140-210V | 170V | 1V | When the voltage is lower than the set value, the protector will cut off the line. |
| Under-voltage recovery value | 145-215V | 175V | 1V | When the voltage is higher than the set value, the protector will automatically reset, and the set value must be more than the under-voltage protection value by more than 5V. |
| Under-voltage recovery delay time | 1-500s | 30s | 1s | After under-voltage recovery, the time needed for automatic reset. |
| Under-voltage protection action time | 0.1-30s | 1.0s | 0.1s | When the voltage is lower than the set value, the time needed for protection action. |
| Three phase voltage unbalance value | 20-99V | 90V | 1V | When the error among the three phase voltage is bigger than the set value, the protector will cut off the line. |
| Three phase voltage unbalance recovery value | 15-94V | 15V | 1V | When the error among the three phase voltage is smaller than the set value, the protector will automatically reset. |
| Phase sequence protection switch | ON/OFF | ON | - | Switch on or off the phase sequence protection function. |
| Over-current protection value | 1A-63A (or 1A-100A) | 30A | 1A | When the current is higher than the set value, the protector will cut off the line. |
| Over-current recovery time | 1-500s | 30s | 1s | After over-current recovery, the time needed for automatic reset. |
| Over-current protection action time | 0.1-30s | 1.0s | 0.1s | When the current is higher than the set value, the time needed for protection action. |
| Times of continuous over current protection | 0-20 | OFF | 1 | When the times of continuous over-current protection exceeds the set value, the protector will cut off the line, then needs to be opened manually. |
| Phase-loss protection | ON | - | - | One of the three-phase voltages is losing, the protector will cut off the line. |

Figure 4: Detailed technical data and operating range parameters.

Figure 5: Dimension Diagram (90mm x 90mm x 50mm).
4. Panel Introduction

Figure 6: Front Panel Layout and Controls.
- Voltage Display Screen: Shows real-time voltage for L1, L2, L3.
- Current Display Screen: Shows real-time current for L1, L2, L3.
- POWER Indicator: Green LED, indicates power status.
- >U Indicator: Red LED, indicates over-voltage fault.
- <U Indicator: Red LED, indicates under-voltage fault.
- >Ie Indicator: Red LED, indicates over-current fault.
- Manual Switch Button: Used to manually turn the protector on/off.
- SET Button: Enters/exits the menu for parameter settings.
- Adjustment Buttons (Up/Down Arrows): Used to navigate menu options and adjust parameter values.
5. Setup and Installation
5.1 Safety Precautions
- The device must be installed by a qualified electrician.
- Always disconnect all power before working on the device. Do not touch any terminal when the power is on.
- Verify correct terminal connections during wiring.
- Do not dismantle or repair the device yourself to avoid errors or damage.
- Install the device in a dry, well-ventilated, and dust-free environment.
- Ensure all wires are securely fastened to prevent poor contact, which can lead to overheating or malfunction.
5.2 Mounting
The OBV2-63 protector is designed for DIN rail mounting. Simply align the DIN rail buckle on the back of the device with the DIN rail and snap it into place. Ensure it is securely fastened.

Figure 7: DIN Rail Buckle for easy installation.
5.3 Wiring Diagram
Connect the protector according to the following diagram for a three-phase system. Ensure proper connection of L1, L2, L3, and Neutral (N) lines, if applicable for your model (some 380V models may not use N). Always double-check all connections before applying power.

Figure 8: Wiring Diagram for 3-Phase System.
6. Operating Instructions
6.1 Initial Power-On and Display
Upon initial power-on, the device will perform a self-check. The digital displays will show the current voltage and current values for each phase (L1, L2, L3). The green POWER indicator LED should light up.

Figure 9: Real-time display of voltage and current.
6.2 Main Menu Setting
To access and adjust parameters, press the SET button. Use the Up and Down arrow buttons to navigate through the menu options and adjust values. Press SET again to confirm a setting or move to the next parameter. The parameters are listed in the Specifications section (Table: Adjustable Operating Range Parameters).
Key adjustable parameters include:
- Power-on delay time (P1)
- Over-voltage protection value (U1)
- Over-voltage recovery value (U2)
- Over-voltage recovery delay time (U3)
- Over-voltage protection action time (U4)
- Under-voltage protection value (U5)
- Under-voltage recovery value (U6)
- Under-voltage recovery delay time (U7)
- Under-voltage protection action time (U8)
- Three phase voltage unbalance value (U9)
- Three phase voltage unbalance recovery value (U10)
- Phase sequence protection switch (U11)
- Over-current protection value (C1)
- Over-current recovery time (C2)
- Over-current protection action time (C3)
- Times of continuous over current protection (C4)
6.3 Manual Switch On/Off
The protector can be manually switched on or off using the dedicated manual switch button on the front panel. This allows for immediate control over the power supply to the protected circuit.
6.4 Fault Indication
When a fault (over-voltage, under-voltage, or over-current) is detected, the corresponding red indicator LED (>U, <U, or >Ie) will light up, and the output relay will open, cutting off power to the protected circuit. The operating voltage and current values will flash on the screen during a fault condition.
6.5 Automatic Reset
For voltage faults, the protector is designed to automatically reset after the voltage returns to a safe range and the recovery delay time has elapsed. During the recovery delay, fault indication LEDs will go out, and the operating voltage and current values will flash.
For current faults, the protector will also automatically reset after the current returns to a safe range and the recovery delay time has elapsed, unless the 'Times of continuous over current protection' setting (C4) has been exceeded, in which case manual reset may be required.
7. Maintenance
- Regular Inspection: Periodically check the device for any visible damage, loose connections, or signs of overheating.
- Cleaning: Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges to prolong the device's lifespan.
- Firmware Updates: Check with the manufacturer for any available firmware updates, though this device typically does not require user-level updates.
8. Troubleshooting
- Device Not Powering On: Check the main power supply and ensure all wiring connections are secure and correct. Verify the input voltage is within the operational range.
- Frequent Tripping: Review the set parameters for over-voltage, under-voltage, and over-current. They might be set too sensitively for your application. Check for actual voltage/current anomalies in your system.
- Fault Indication LEDs On: If a red LED (>U, <U, or >Ie) is lit, it indicates a fault. Identify the type of fault from the LED and address the underlying issue in your electrical system.
- No Automatic Reset After Fault: For current faults, if the 'Times of continuous over current protection' (C4) setting has been exceeded, the device will require a manual reset. Disconnect the overload and then manually reset the protector. For voltage faults, ensure the voltage has returned to a stable range and the recovery delay time has passed.
- Incorrect Phase Sequence Indication: If the phase sequence protection is enabled and an incorrect sequence is detected, the device will trip. Verify and correct the phase wiring.
- Display Malfunction: If the digital display is blank or showing erratic readings, ensure stable power supply. If the issue persists, contact technical support.
9. User Tips
- Optimal Settings: Take time to calibrate the voltage and current protection parameters (U1-U10, C1-C4) to match the specific requirements and tolerances of your connected equipment. This prevents unnecessary tripping while ensuring adequate protection.
- Regular Monitoring: Periodically check the real-time voltage and current displays to understand your system's normal operating conditions and quickly identify any deviations.
- Professional Installation: Always ensure installation is performed by a qualified professional to guarantee safety and correct functionality.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase records handy when seeking support.