1. Overview
The Tracer BP series solar charge controller adopts advanced Maximum Power Point Tracking (MPPT) charging technology, enhancing system charging efficiency and lowering system cost. This controller supports various battery types, including sealed, gel, flooded, and lithium batteries. Users can monitor and modify operational status and parameters. It is suitable for solar home systems, traffic signals, solar street lights, and solar garden lamps.
Key Features:
- High-quality components (ST, IR, Infineon) for extended lifespan.
- Wide operating temperature range.
- Compatible with lead-acid and lithium batteries.
- Lithium battery self-activating and low-temperature protection.
- Maximum conversion efficiency of 98%.
- MPPT technology with tracking efficiency no less than 99%.
- Ultra-fast tracking speed and accurate recognition of multiple power points.
- PV power limitation function.
- Monitoring and parameter setting via Mobile APP and PC software with RS485 communication interface.
- Standard Modbus communication protocol for RS485 bus connections.
- IoT module and Cloud Server monitoring software for remote monitoring.
- RS485 connector provides power supply.
- Aluminum housing for efficient cooling.
- Real-time energy statistics function.
- IP68 waterproof rating.


2. Safety Information
Please read all instructions carefully before installation and pay attention to the following safety guidelines:
- DO NOT disassemble or attempt to repair the controller.
- Install an external fast-acting fuse or breaker as required.
- Disconnect the solar module and fast-acting fuse/breakers near the battery before installing or moving the controller.
- Power connections must remain tight to avoid excessive heating from a loose connection.
- Only batteries that comply with the controller's parameters can be charged.
- Battery connection may be wired to one battery or a bank of batteries.
- Risk of electric shock: PV and load may produce high voltages when the controller is running.
3. Setup and Wiring
Follow the connection sequence carefully to ensure proper and safe installation.
Connection Sequence:
- Connect components to the controller in the sequence: Battery > PV > Load. Pay close attention to the '+' and '-' terminals. Do not insert the fast-acting fuse or turn on the breaker during installation. When disconnecting the system, reverse this order.
- After powering the controller, the battery LED indicator on the controller should flash green. If it is not green, refer to the Troubleshooting section.
- Connect a fast-acting fuse in series through the battery positive (+) in the circuit. The battery fast-acting fuse must be 1.25 to 2 times the rated current. The installed distance should be within 150mm.
Load Self-Test Function:
The load is automatically turned ON after powering on the controller for 10 seconds. After the load remains ON for 10 seconds, the controller restores to the set working mode.


4. Operating Instructions
Load Working Modes:
The controller offers various load working modes:
- Manual Control (Default ON): Load is controlled manually.
- Real-Time Control: Load ON/OFF time is controlled by a real-time clock.
- Light ON/OFF: Load turns ON at dusk and OFF at dawn.
- Turn-On voltage (Adjustable): 5V (12V system), delay 10 min.
- Turn-Off voltage (Adjustable): 6V (12V system), delay 10 min.
- Note: For 24V system voltage, multiply values by 2.
- Light ON + Timer: Load turns ON at dusk and stays ON for a set duration.
CAUTION: In Light ON/OFF and Light ON+Timer modes, the Load is turned on after a 10-minute delay.

LED Indicators:
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| PV | Green | On Solid | PV connection normal but low voltage (irradiance) from PV, no charging |
| Slowly Flashing (1Hz) | In charging | ||
| OFF | OFF | No PV voltage (night time) or PV connection problem | |
| BATT | Orange | On Solid | Battery is normal |
| Green | Fast Flashing (4Hz) | Battery charges full | |
| Red | Fast Flashing (4Hz) | Battery over-discharged | |
| On Solid | Battery under voltage | ||
| COM | Green | Flashing (1Hz) | Communication normal |
Note: When the battery type is lithium, the controller does not automatically recognize the system voltage.
5. Maintenance
Electronic Protections:
- PV Over Current: The controller limits battery charging current to its maximum rating. Oversized solar arrays will not operate at peak power.
- PV Short Circuit: If a PV short circuit occurs at low power, charging stops. Clear the short circuit to resume. At high power, a PV short circuit can damage the controller.
- PV Reverse Polarity: Complete protection against reverse battery polarity when PV is not connected or connected in reverse. The controller may be damaged if PV array has straight polarity and operating power is too high.
- Battery Reverse Polarity: Complete protection against reverse battery polarity when PV is not connected or connected in reverse. The controller may be damaged if PV connection is correct but battery connection is reversed.
- Battery Over Voltage: Charging stops when battery voltage reaches the Over Voltage Disconnect Voltage to prevent overcharging.
- Battery Over Discharge: Discharging stops when battery voltage reaches the Low Voltage Disconnect Voltage to prevent over-discharging.
- Battery Overheating: If ambient temperature exceeds 65°C, the controller stops working and recovers below 55°C.
- Lithium Battery Low Temperature: Charging/discharging stops if temperature is below the low-temperature value and resumes when above it.
- Load Overload: If load current exceeds 1.05 times the maximum rating, the load disconnects. Reduce load and restart.
- Load Short Circuit: Load switches off if a short circuit (24 times rated current) occurs. The controller attempts to reconnect 5 times with increasing delays (5s, 10s, 15s, 20s, 25s). If the fault persists, clear the short circuit and restart the controller or wait for one night-day cycle.
- Temperature Sensor Break Down: If the temperature sensor is short-circuited or damaged, the controller charges/discharges at a default temperature of 25°C to prevent battery damage.
- High Voltage Transients: The controller is protected against small high voltage transients. Additional external suppression is recommended in lightning-prone areas.
6. Troubleshooting
| Faults | Possible Reasons | Troubleshooting |
|---|---|---|
| LED Charging indicator turn off during daytime when sunshine falls on PV modules properly | PV array disconnection | Confirm that PV and battery wire connections are correct and tight. |
| No LED indicator | Battery voltage may be less than 8.5V | Measure battery voltage with a multi-meter. Min. 8.5V can start up the controller. |
| Battery LED indicator green fast Flashing | Battery over voltage | Check if the battery voltage is higher than OVD, and disconnect the PV. |
| Battery LED indicator red | Battery over-discharged | When the battery voltage is restored to or above the LVR point (low voltage reconnect voltage), the load will recover. |
| Battery LED indicator red flashing | Battery Overheating | The controller will automatically turn the system off. But while the temperature decline to be below 50°C, the controller will resume. |
| Load is not output | Load Overload | 1. Reduce the number of electric equipment. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
| Load Short Circuit | 1. Check carefully loads connection, clear the fault. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
7. Specifications (Tracer7810BP)
| Parameter | Value |
|---|---|
| Nominal system voltage | 12/24VDC/Auto |
| Battery type | Lead-acid (Sealed/Gel/Flooded)/Lithium (LiFePO4/Li(NiCoMN)O2)/User |
| Battery input voltage range | 8.5~32VDC |
| Rated charge current | 30A |
| Rated discharge current | 30A |
| Rated charge power | 390W/12V; 780W/24V |
| Max. conversion efficiency | ≤98% |
| Tracking efficiency | ≥99% |
| MPP voltage range | (Battery Voltage+2V)~72V |
| Max. PV open circuit voltage | 100V (at minimum operating environment temperature); 92V (at 25℃ environment temperature) |
| Equalization voltage | Sealed:14.6V, Flooded:14.8V, User-defined:9-17V |
| Boost voltage | Gel:14.2V, Sealed:14.4V, Flooded:14.6V, User-defined:9-17V |
| Float voltage | Gel/Sealed/Flooded:13.8V, User-defined:9-17V |
| Low voltage reconnect voltage | Gel/Sealed/Flooded:12.6V, User-defined:9-17V |
| Low voltage disconnect voltage | Gel/Sealed/Flooded:11.1V, User-defined:9-17V |
| Self-consumption | ≤13mA(12V); ≤11.5mA(24V) |
| Temperature compensation (for lead-acid battery) | -3mV/℃/2V (Lithium battery don't have temperature compensation coefficient) |
| Enclosure | IP68 |
| Communication interface | RS485 (Waterproof) |
| Operating temperature range | -40℃~60℃ |
| Dimensions (LxWxH) | 153.3 x 105 x 52.1 mm |
| Net weight | 1.26kg |

8. Optional Accessories and Software
Enhance your controller's functionality with these optional accessories:
- Bluetooth Adapter: For wireless monitoring via mobile app.
- WiFi Adapter: For wireless monitoring via mobile app.
- USB Communication Cable: For PC monitoring and parameter setting.
- MT52 Remote Meter: For local monitoring and control (Note: MT52 does not support relevant lithium battery parameters).
- eLOG01 Data Logger: For data logging.
Software:
- PC Software: Available on www.epever.com (Solar Station Monitor).
- APP Software (Android/iPhone): Available on www.epever.com or APP Store (search for EPEVER--EP-01).

9. User Tips
- Always ensure proper ventilation around the controller to prevent overheating, especially in enclosed spaces.
- Regularly check all wire connections for tightness to prevent power loss and potential hazards.
- Monitor the battery voltage and charge status frequently, especially during initial setup, to ensure optimal performance and battery health.
- If using lithium batteries, ensure the correct battery type is selected in the controller settings for proper charging algorithms and protection.
- For remote monitoring, ensure your communication module (Bluetooth/WiFi/USB) is correctly connected and the corresponding software/app is installed and configured.
10. Warranty and Support
Disclaimer:
This warranty does not apply under the following conditions:
- Damage from improper use or use in an unsuitable environment.
- PV or load current, voltage, or power exceeds the rated value of the controller.
- The controller's working temperature exceeds the limit working environment temperature.
- User disassembly or attempted to repair the controller without permission.
- The controller is damaged due to natural elements such as lightning.
- The controller is damaged during transportation and shipment.
For detailed warranty information and further support, please refer to the complete user manual available for download: