1. Overview

The Tracer BP series solar charge controller adopts advanced Maximum Power Point Tracking (MPPT) charging technology, enhancing system charging efficiency and lowering system cost. This controller supports various battery types, including sealed, gel, flooded, and lithium batteries. Users can monitor and modify operational status and parameters. It is suitable for solar home systems, traffic signals, solar street lights, and solar garden lamps.

Key Features:

  • High-quality components (ST, IR, Infineon) for extended lifespan.
  • Wide operating temperature range.
  • Compatible with lead-acid and lithium batteries.
  • Lithium battery self-activating and low-temperature protection.
  • Maximum conversion efficiency of 98%.
  • MPPT technology with tracking efficiency no less than 99%.
  • Ultra-fast tracking speed and accurate recognition of multiple power points.
  • PV power limitation function.
  • Monitoring and parameter setting via Mobile APP and PC software with RS485 communication interface.
  • Standard Modbus communication protocol for RS485 bus connections.
  • IoT module and Cloud Server monitoring software for remote monitoring.
  • RS485 connector provides power supply.
  • Aluminum housing for efficient cooling.
  • Real-time energy statistics function.
  • IP68 waterproof rating.
EPEVER Tracer-BP Series MPPT Solar Charge Controller highlighting IP68 waterproof, 10A-30A, 12V/24V Auto, 100V Max PV Input.
EPEVER Tracer-BP Series MPPT Solar Charge Controller: IP68 waterproof, 10A-30A, 12V/24V Auto, 100V Max PV Input.
EPEVER Tracer7810BP MPPT Solar Charge Controller highlighting high efficiency (Max. conversion efficiency ≤98%, Tracking efficiency ≥99%).
High Efficiency: Max. conversion efficiency ≤98%, Tracking efficiency ≥99%.

2. Safety Information

Please read all instructions carefully before installation and pay attention to the following safety guidelines:

  • DO NOT disassemble or attempt to repair the controller.
  • Install an external fast-acting fuse or breaker as required.
  • Disconnect the solar module and fast-acting fuse/breakers near the battery before installing or moving the controller.
  • Power connections must remain tight to avoid excessive heating from a loose connection.
  • Only batteries that comply with the controller's parameters can be charged.
  • Battery connection may be wired to one battery or a bank of batteries.
  • Risk of electric shock: PV and load may produce high voltages when the controller is running.

3. Setup and Wiring

Follow the connection sequence carefully to ensure proper and safe installation.

Connection Sequence:

  1. Connect components to the controller in the sequence: Battery > PV > Load. Pay close attention to the '+' and '-' terminals. Do not insert the fast-acting fuse or turn on the breaker during installation. When disconnecting the system, reverse this order.
  2. After powering the controller, the battery LED indicator on the controller should flash green. If it is not green, refer to the Troubleshooting section.
  3. Connect a fast-acting fuse in series through the battery positive (+) in the circuit. The battery fast-acting fuse must be 1.25 to 2 times the rated current. The installed distance should be within 150mm.

Load Self-Test Function:

The load is automatically turned ON after powering on the controller for 10 seconds. After the load remains ON for 10 seconds, the controller restores to the set working mode.

Basic wiring diagram for the MPPT solar charge controller, showing connections for Load (1), Battery (2), and PV (3) with breakers and fuse.
Basic Wiring Diagram: Connect Load (1), Battery (2), and PV (3) in sequence.
Detailed diagram of Tracer26**/39**BP and Tracer52**/7810BP models showing connection points for Temperature Sensor, PV Wires, Battery Wires, Load Wires, Charging Status LED, Battery Status LED, RS485 waterproof port, and waterproof cap. Includes RS485 port pinout.
Detailed Connection Points: (1) Temperature Sensor, (2) PV Positive and Negative Wires, (3) Battery Positive and Negative Wires, (4) Load Positive and Negative Wires, (5) Charging Status LED indicator, (6) Battery Status LED indicator, (7) RS485 waterproof port, (8) Waterproof cap (Included). RS485 port pinout also shown.
Video: Unboxing and connection preview of the EPEVER Tracer-BP series solar charge controller.

4. Operating Instructions

Load Working Modes:

The controller offers various load working modes:

  • Manual Control (Default ON): Load is controlled manually.
  • Real-Time Control: Load ON/OFF time is controlled by a real-time clock.
  • Light ON/OFF: Load turns ON at dusk and OFF at dawn.
    • Turn-On voltage (Adjustable): 5V (12V system), delay 10 min.
    • Turn-Off voltage (Adjustable): 6V (12V system), delay 10 min.
    • Note: For 24V system voltage, multiply values by 2.
  • Light ON + Timer: Load turns ON at dusk and stays ON for a set duration.

CAUTION: In Light ON/OFF and Light ON+Timer modes, the Load is turned on after a 10-minute delay.

Load Working Mode diagram showing Manual Control, Real-Time Control, Light ON/OFF, and Light ON + Timer. Includes adjustable turn-on/off voltages.
Load Working Mode Diagram: Illustrates Manual, Light ON/OFF, and Light ON + Timer modes with adjustable voltage settings.

LED Indicators:

IndicatorColorStatusInstruction
PVGreenOn SolidPV connection normal but low voltage (irradiance) from PV, no charging
Slowly Flashing (1Hz)In charging
OFFOFFNo PV voltage (night time) or PV connection problem
BATTOrangeOn SolidBattery is normal
GreenFast Flashing (4Hz)Battery charges full
RedFast Flashing (4Hz)Battery over-discharged
On SolidBattery under voltage
COMGreenFlashing (1Hz)Communication normal

Note: When the battery type is lithium, the controller does not automatically recognize the system voltage.

5. Maintenance

Electronic Protections:

  • PV Over Current: The controller limits battery charging current to its maximum rating. Oversized solar arrays will not operate at peak power.
  • PV Short Circuit: If a PV short circuit occurs at low power, charging stops. Clear the short circuit to resume. At high power, a PV short circuit can damage the controller.
  • PV Reverse Polarity: Complete protection against reverse battery polarity when PV is not connected or connected in reverse. The controller may be damaged if PV array has straight polarity and operating power is too high.
  • Battery Reverse Polarity: Complete protection against reverse battery polarity when PV is not connected or connected in reverse. The controller may be damaged if PV connection is correct but battery connection is reversed.
  • Battery Over Voltage: Charging stops when battery voltage reaches the Over Voltage Disconnect Voltage to prevent overcharging.
  • Battery Over Discharge: Discharging stops when battery voltage reaches the Low Voltage Disconnect Voltage to prevent over-discharging.
  • Battery Overheating: If ambient temperature exceeds 65°C, the controller stops working and recovers below 55°C.
  • Lithium Battery Low Temperature: Charging/discharging stops if temperature is below the low-temperature value and resumes when above it.
  • Load Overload: If load current exceeds 1.05 times the maximum rating, the load disconnects. Reduce load and restart.
  • Load Short Circuit: Load switches off if a short circuit (24 times rated current) occurs. The controller attempts to reconnect 5 times with increasing delays (5s, 10s, 15s, 20s, 25s). If the fault persists, clear the short circuit and restart the controller or wait for one night-day cycle.
  • Temperature Sensor Break Down: If the temperature sensor is short-circuited or damaged, the controller charges/discharges at a default temperature of 25°C to prevent battery damage.
  • High Voltage Transients: The controller is protected against small high voltage transients. Additional external suppression is recommended in lightning-prone areas.

6. Troubleshooting

FaultsPossible ReasonsTroubleshooting
LED Charging indicator turn off during daytime when sunshine falls on PV modules properlyPV array disconnectionConfirm that PV and battery wire connections are correct and tight.
No LED indicatorBattery voltage may be less than 8.5VMeasure battery voltage with a multi-meter. Min. 8.5V can start up the controller.
Battery LED indicator green fast FlashingBattery over voltageCheck if the battery voltage is higher than OVD, and disconnect the PV.
Battery LED indicator redBattery over-dischargedWhen the battery voltage is restored to or above the LVR point (low voltage reconnect voltage), the load will recover.
Battery LED indicator red flashingBattery OverheatingThe controller will automatically turn the system off. But while the temperature decline to be below 50°C, the controller will resume.
Load is not outputLoad Overload1. Reduce the number of electric equipment. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours).
Load Short Circuit1. Check carefully loads connection, clear the fault. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours).

7. Specifications (Tracer7810BP)

ParameterValue
Nominal system voltage12/24VDC/Auto
Battery typeLead-acid (Sealed/Gel/Flooded)/Lithium (LiFePO4/Li(NiCoMN)O2)/User
Battery input voltage range8.5~32VDC
Rated charge current30A
Rated discharge current30A
Rated charge power390W/12V; 780W/24V
Max. conversion efficiency≤98%
Tracking efficiency≥99%
MPP voltage range(Battery Voltage+2V)~72V
Max. PV open circuit voltage100V (at minimum operating environment temperature); 92V (at 25℃ environment temperature)
Equalization voltageSealed:14.6V, Flooded:14.8V, User-defined:9-17V
Boost voltageGel:14.2V, Sealed:14.4V, Flooded:14.6V, User-defined:9-17V
Float voltageGel/Sealed/Flooded:13.8V, User-defined:9-17V
Low voltage reconnect voltageGel/Sealed/Flooded:12.6V, User-defined:9-17V
Low voltage disconnect voltageGel/Sealed/Flooded:11.1V, User-defined:9-17V
Self-consumption≤13mA(12V); ≤11.5mA(24V)
Temperature compensation (for lead-acid battery)-3mV/℃/2V (Lithium battery don't have temperature compensation coefficient)
EnclosureIP68
Communication interfaceRS485 (Waterproof)
Operating temperature range-40℃~60℃
Dimensions (LxWxH)153.3 x 105 x 52.1 mm
Net weight1.26kg
EPEVER Tracer7810BP MPPT Solar Charge Controller with key features: 100V Max PV open circuit, 12/24VDC Auto Nominal system voltage, 390W/12V 780W/24V Rated charge power.
Key Specifications: 100V Max PV open circuit, 12/24VDC Auto Nominal system voltage, 390W/12V 780W/24V Rated charge power.

8. Optional Accessories and Software

Enhance your controller's functionality with these optional accessories:

  • Bluetooth Adapter: For wireless monitoring via mobile app.
  • WiFi Adapter: For wireless monitoring via mobile app.
  • USB Communication Cable: For PC monitoring and parameter setting.
  • MT52 Remote Meter: For local monitoring and control (Note: MT52 does not support relevant lithium battery parameters).
  • eLOG01 Data Logger: For data logging.

Software:

  • PC Software: Available on www.epever.com (Solar Station Monitor).
  • APP Software (Android/iPhone): Available on www.epever.com or APP Store (search for EPEVER--EP-01).
Optional Accessories for EPEVER MPPT Solar Charge Controller, including Bluetooth Adapter, WiFi Adapter, USB communication cable, MT52 remote meter, and eLOG01 data logger.
Optional Accessories: Bluetooth Adapter, WiFi Adapter, USB cable, MT52 remote meter, and eLOG01 data logger.

9. User Tips

  • Always ensure proper ventilation around the controller to prevent overheating, especially in enclosed spaces.
  • Regularly check all wire connections for tightness to prevent power loss and potential hazards.
  • Monitor the battery voltage and charge status frequently, especially during initial setup, to ensure optimal performance and battery health.
  • If using lithium batteries, ensure the correct battery type is selected in the controller settings for proper charging algorithms and protection.
  • For remote monitoring, ensure your communication module (Bluetooth/WiFi/USB) is correctly connected and the corresponding software/app is installed and configured.

10. Warranty and Support

Disclaimer:

This warranty does not apply under the following conditions:

  • Damage from improper use or use in an unsuitable environment.
  • PV or load current, voltage, or power exceeds the rated value of the controller.
  • The controller's working temperature exceeds the limit working environment temperature.
  • User disassembly or attempted to repair the controller without permission.
  • The controller is damaged due to natural elements such as lightning.
  • The controller is damaged during transportation and shipment.

For detailed warranty information and further support, please refer to the complete user manual available for download:

Download Full User Manual (PDF)

© 2024 EPEVER. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.