1. Important Safety Instructions
Please reserve this manual for future review. This manual contains safety, installation, and operation instructions for the Tracer-AN G3/Tracer-AN G3 BLE series MPPT solar controller ("controller" referred to in this manual).
- Read all the instructions and warnings carefully in the manual before installation.
- No user-serviceable components inside the controller; please do not disassemble or attempt to repair the controller.
- Mount the controller indoors. Avoid exposure to the components and do not allow water to enter the controller.
- Install the controller in a well-ventilated place; the controller's heat sink may become hot during operation.
- We suggest installing appropriate external fast-acting fuses/breakers.
- Disconnect PV array connections and the battery fast-acting fuse/breakers before controller installation and adjustment.
- Power connections must remain tight to avoid excessive heating from a loose connection.
WARNING:
Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
2. Disclaimers
The warranty does not apply to the following conditions:
- Damage caused by improper use or inappropriate environment (such as humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments).
- The actual current/voltage/power exceeds the limit value of the controller.
- Damage caused by working temperature exceeding the rated range.
- Arc, fire, explosion, and other accidents caused by failure to follow the controller stickers or manual instructions.
- Unauthorized dismantling or attempted repair.
- Damage caused by force majeure.
- Damage occurred during transportation or handling.
3. Product Overview and Features
The Tracer-AN G3/Tracer-AN G3 BLE series controllers are designed with advanced MPPT control algorithms to minimize power loss and maximize energy harvesting from PV arrays. The G3 BLE series includes a built-in Bluetooth module for convenient parameter adjustment via a phone app.
Key Features:
- High quality and low failure rate components for extended service life.
- Advanced MPPT technology with >99.5% tracking efficiency.
- Accurate multi-peak maximum power point recognition.
- Wider MPP running voltage to optimize PV utilization.
- Maximum DC/DC conversion efficiency of 98%.
- Support for multiple battery types, including lithium batteries.
- Stable self-activation function for lithium batteries.
- Adjustable battery voltage parameters via LCD.
- Battery temperature compensation.
- Charging power and current limit to rated values.
- Real-time energy statistics function.
- Automatic charging power reduction for over-temperature.
- Built-in Bluetooth (G3 BLE series) for app-based settings.
- RS485 communication interface with optional 4G or Wi-Fi modules.
- Standard Modbus communication protocol.
- Power protection chip for 5VDC/200mA output with over-current and short-circuit protections.
- Setting parameters via PC software, APP, or remote meter.
- Constant voltage output function.
- Comprehensive electronic protections.
- Multiple load work modes.
- Low self-consumption (<10mA).
- Operation at full load without charging power reduced in the working temperature range.
Product Characteristics Diagram

4. Setup and Installation
4.1 Naming Rules
The model numbers follow a specific naming convention:
- Tracer X Y Z AN G3: X = Rated charging & discharging current (e.g., 4 for 40A), Y = Battery rated voltage (e.g., 2 for 12/24VDC), Z = PV maximum open-circuit voltage (e.g., 10 for 100V), AN = Common negative system, G3 = 3rd generation product.
- Tracer X Y Z AN G3 BLE: Same as above, with BLE indicating a built-in Bluetooth module.
4.2 Connection Diagram
The controller supports both no-battery mode (direct connection to inverter) and battery mode.

No-battery Mode:
When there is no battery, the Tracer-AN G3/Tracer-AN G3 BLE series can be directly connected to the inverter. The inverter shall be connected to the battery terminals of the controller and meets the following conditions:
- For high-frequency inverter: PV input power > (load output power ÷ inverter conversion efficiency ÷ controller conversion efficiency)
- For power frequency inverter: PV input power > (load output power ÷ inverter conversion efficiency ÷ controller conversion efficiency ÷ 2)
Battery Mode:

4.3 Requirements for the PV Array
The controller needs to suit various types of PV modules and maximize solar energy conversion. The serial connection (string) of PV modules depends on the open-circuit voltage (Voc) and maximum power point voltage (VMPP) of the MPPT controller.
| System voltage | 36cell (Voc< 23V) | 48cell (Voc< 31V) | 54cell (Voc< 34V) | 60cell (Voc< 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 2 | 2 | 1 | 1 | 1 | 1 | 1 | 1 |
| 24V | 2 | 2 | - | - | - | - | - | - |
Note: These parameters are calculated under STC (Standard Test Condition: module temperature 25°C, air mass 1.5, irradiance 1000W/m²).
| System voltage | 36cell (Voc< 23V) | 48cell (Voc< 31V) | 54cell (Voc< 34V) | 60cell (Voc< 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 | 2 | 1 | 2 | 1 |
| 24V | 4 | 3 | 2 | 2 | 2 | 2 | 2 | 2 |
Note: These parameters are calculated under STC (Standard Test Condition: module temperature 25°C, air mass 1.5, irradiance 1000W/m²).
4.4 Wire Size
The wiring and installation methods must conform to national and local electrical code requirements. The minimum wire size can be calculated from the PV array's short circuit current (ISC).
| Model | Max. PV input current | Max. PV wire size |
|---|---|---|
| Tracer1206/1210AN G3/BLE | 10A | 4mm²/12AWG |
| Tracer2206/2210AN G3/BLE | 20A | 6mm²/10AWG |
| Tracer3210AN G3/BLE | 30A | 10mm²/8AWG |
| Tracer4210AN G3/BLE | 40A | 16mm²/6AWG |
CAUTION:
The total voltage must not exceed the PV maximum open-circuit voltage when the PV modules are connected in series. The PV maximum open-circuit voltage is 46V (Tracer**06AN G3/BLE) or 92V (Tracer**10AN G3/BLE) at 25°C environment temperature.
| Model | Rated charge current | Rated discharge current | Battery wire size | Load wire size |
|---|---|---|---|---|
| Tracer1206/1210AN G3/BLE | 10A | 10A | 4mm²/12AWG | 4mm²/12AWG |
| Tracer2206/2210AN G3/BLE | 20A | 20A | 6mm²/10AWG | 6mm²/10AWG |
| Tracer3210AN G3/BLE | 30A | 30A | 10mm²/8AWG | 10mm²/8AWG |
| Tracer4210AN G3/BLE | 40A | 40A | 16mm²/6AWG | 16mm²/6AWG |
CAUTION:
- The wire size is only for reference. For long distances between the PV array and the controller or between the controller and the battery, use larger wires to reduce voltage drop and improve performance.
- The recommended wire is selected for the battery according to the conditions that its terminals are not connected to any additional inverter.
4.5 Mounting
Installation procedures:
Step 1: Determine the installation location and heat-dissipation space

WARNING:
- Risk of explosion! Never install the controller in a sealed enclosure with flooded batteries! Do not install the controller in a confined area where battery gas can accumulate.
- Risk of electric shock! The PV array may generate a high open-circuit voltage when wiring the PV modules. Disconnect the breaker or fast-acting fuse first, and be careful when wiring.
CAUTION:
The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
Step 2: Connect the system in the order of battery → load → PV array, following the schematic wiring diagram, and disconnect the system in the reverse order.
4.6 Grounding
Tracer-AN G3/Tracer-AN G3 BLE series are common-negative controllers. Negative terminals of the PV array, the battery, and the load can be grounded simultaneously, or any negative terminal can be grounded. However, the grounding terminal on its shell must be grounded to shield electromagnetic interference and avoid electric shock.
CAUTION:
It is recommended to use a common-negative controller for common-negative systems, such as the RV system. The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in the common-negative system.
4.7 Connect Accessories
Temperature Sensor:
Connect one end of the remote temperature sensor cable to the interface and place the other end close to the battery.
CAUTION:
If the remote temperature sensor is not connected or damaged, the controller will charge or discharge the battery at the default temperature setting of 25 °C (no temperature compensation).
RS485 Communication:
Connect the accessories for RS485 communication. The internal circuit of the RS485 port has no isolation design. Connecting an RS485 communication isolator to the port is recommended before communicating.

4.8 Power On the Controller
Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (the controller operates normally when the indicator is lit green). Connect the fast-acting fuse and circuit breaker of the load and PV array. The system will then operate in preprogrammed mode.
CAUTION:
If the controller is not operating properly or the battery indicator shows an abnormality, please refer to the Troubleshooting section.
5. Operating Instructions
5.1 Maximum Power Point Tracking (MPPT) Technology
Due to the nonlinear characteristics of the solar array, there is a maximum energy output point (Max Power Point) on its curve. Our MPPT algorithm continuously compares and adjusts the operating points to locate the array's maximum power point, boosting the battery charge current. This process is fully automatic and does not require user adjustment.


5.2 Battery Charging Stages
The controller employs a three-stage battery charging algorithm: Bulk Charging, Constant Charging (Equalize and Boost), and Float Charging. This extends battery lifespan and improves system performance.

A) Bulk Charging:
The controller operates in constant current mode, delivering maximum current until the battery voltage reaches the constant voltage set point.
B) Constant Charging (Equalize and Boost):
Once the constant voltage set point is reached, the controller enters constant charging mode. The charging current gradually drops. Equalize charging occurs on the 28th of each month. Boost charging typically lasts 2 hours (adjustable).
WARNING (Equalize Charging):
Explosive Risk! Equalizing flooded batteries produces explosive gases; ensure good ventilation. Equipment damage! Equalization may increase battery voltage, damaging sensitive DC loads. Over-charging can damage battery plates. Review battery requirements carefully.
C) Float Charging:
After constant charging, the controller reduces battery voltage to the float charging preset voltage. In this stage, loads can obtain almost all power from the solar panel. If load power exceeds solar array power, the controller will exit float charging and re-enter bulk charging if battery voltage drops below the boost voltage reconnect voltage.
5.3 LCD Interface
The LCD displays system information. Ensure the viewing angle is within 90° for clear visibility.
Buttons:
- ENTER button: Used to turn load On/Off in manual mode, clear faults, and confirm settings. Hold for 5s to enter setting mode.
- SELECT button: Used to browse modes and set parameters.
Status Description:
| Name | Icon | Status |
|---|---|---|
| PV array | ☀️ | Day |
| 🌙 | Night | |
| 🚫 | No charge | |
| Battery | 🔋 | Battery capacity, In charging |
| 📊 | Battery Voltage, Current, Temperature | |
| ⚙️ | Battery type | |
| Load | 💡 | Load ON |
| 🚫💡 | Load OFF | |
| ⚡ | Current/Consumed energy/Load mode |
Error Codes:
| Status | Icon | Instruction |
|---|---|---|
| Battery over-discharged | ⚠️🔋 | Battery level shows empty, battery frame blink, fault icon blink |
| Battery over voltage | ⚠️🔋 | Battery level shows full, battery frame blink, fault icon blink |
| Battery overheating | ⚠️🔋 | Battery level shows current value, battery frame blink, fault icon blink |
| Load failure | ⚠️💡 | Overload, Load short circuit |
5.4 Setting Parameters
Clear Generated Energy:
- Press the ENTER button and hold 5s under the PV-generated energy interface; the value will flash.
- Press the ENTER button again to clear the generated energy.
Switch Battery Temperature Unit:
Press the button and hold for 5s under the battery temperature interface to switch the temperature unit.
Battery Type:
The controller supports Sealed (default), Gel, Flooded, LiFePO4, Li(NiCoMn)O2, and User-defined battery types.
Local Setting via LCD:
- Press SELECT to jump to the battery voltage interface.
- Press and hold ENTER until the battery-type interface flashes.
- Press SELECT to change the battery type.
- Press ENTER to confirm.
Remote Setting via PC Software:
Connect the controller's RJ45 port to the PC's USB interface via a USB to RS485 cable. When selecting "USE" battery type, set voltage parameters via PC software.
Remote Setting via APP:
Connect the controller to an external WiFi 2.4G adapter or Bluetooth adapter (or use built-in Bluetooth for G3 BLE series). Set voltage parameters via the APP after selecting "USE" battery type.
Load Modes:
The controller offers various load modes, including Light ON/OFF, Test mode, and Manual mode (Always ON). These can be set via PC software, APP, or a remote meter (MT50).
| Mode (Timer 1) | Description | Mode (Timer 2) | Description |
|---|---|---|---|
| 100 | Light ON/OFF | 2 n | Disabled |
| 101 | Load on for 1 hour since sunset | 201 | Load on for 1 hour before sunrise |
| 102 | Load on for 2 hours since sunset | 202 | Load on for 2 hours before sunrise |
| 103~113 | Load on for 3~13 hours since sunset | 203~213 | Load on for 3~13 hours before sunrise |
| 114 | Load on for 14 hours since sunset | 214 | Load on for 14 hours before sunrise |
| 115 | Load on for 15 hours since sunset | 215 | Load on for 15 hours before sunrise |
| 116 | Test mode | 2 n | Disabled |
| 117 | Manual mode (Default load ON) | ||
| 118 | Always ON mode (24-hour power supply) | 2 n | Disabled |
6. Maintenance
The following inspections and maintenance tasks are recommended at least twice yearly for good performance:
- Ensure no block on airflow around the controller. Clear up any dirt and fragments on the radiator.
- Check all naked wires to ensure insulation is not damaged by sun exposure, frictional wear, dryness, insects or rats, etc. Repair or replace some wires if necessary.
- Verify the indicator display is consistent with the actual operation. Pay attention to any troubleshooting or error conditions. Take necessary corrective action.
- Confirm that terminals have no corrosion, insulation damaged, high temperature, burnt/discolored sign, and tighten terminal screws to the suggested torque.
- Clear up dirt, nesting insects, and corrosion in time.
- Check and confirm that the lightning arrester is in good condition. Replace a new one in time to avoid damaging the controller and other equipment.
CAUTION:
Risk of electric shock! Ensure the power is turned off before performing any maintenance operations.
7. Troubleshooting
7.1 Protection Functions
The controller includes various protection mechanisms:
- PV Over Current: Controller charges at rated current/power if PV input exceeds it.
- PV Short-circuit: Controller is not damaged if PV array is short-circuited when not charging. WARNING: Do not short-circuit PV array during charging.
- PV Reverse Polarity: Controller may not be damaged and resumes work after correcting mis-wiring. CAUTION: Controller may be damaged if PV array is reversed and its actual power is 1.5 times the rated power.
- Night Reverse Charging: Prevents battery discharge to PV module at night.
- Battery Reverse Protection: Correct wire connection to resume work. WARNING: Controller will be damaged if PV connection is correct and battery connection is reversed!
- Battery Over Voltage: PV array stops charging when battery voltage reaches over voltage disconnect voltage.
- Battery Over-discharging: Battery discharge stops when voltage is lower than low voltage disconnect voltage.
- Battery Overheating: Stops charging when battery temperature exceeds 65°C, resumes below 55°C.
- Lithium Battery Low Temperature: Stops charging/discharging if temperature is below Low-Temperature Protection Threshold (LTPT, default 0°C, adjustable).
- Load Short Circuit: Controller cuts off output, attempts to resume five times automatically (with delays). Can be reset by pressing Load button, restarting controller, or night-to-day change.
- Overload Protection: Controller cuts off output after a delay if load current exceeds 1.05 times rating, attempts to resume five times automatically (with delays). Can be reset by pressing Load button, restarting controller, or night-to-day change.
- Device Overheating: Stops working if internal temperature exceeds 85°C, resumes below 75°C.
- TVS High Voltage Transients: Internal circuitry protects against high-voltage surge pulses with less energy. External surge arrester recommended in lightning-prone areas.
7.2 Troubleshooting Table
| Faults | Possible Cause | Troubleshooting |
|---|---|---|
| PV array open-circuit | No direct sunlight or incorrect connection. | Confirm PV array connection is correct and tight. |
| Battery voltage is lower than 8V | Battery deeply discharged or controller not working. | Check battery voltage (must be at least 8V to activate controller). |
| Battery over voltage | Battery voltage higher than OVD. | Disconnect PV array connection. |
| Battery over-discharged | Battery voltage below LVR. | Recharge battery using other methods. Load will recover when battery voltage is restored. |
| Battery overheating | Battery temperature above 55°C. | Controller will resume when temperature declines below 55°C. |
| Overload | Excessive load connected. | Reduce number of electric devices. Restart controller or press button to clear faults. |
| Load short-circuit | Short circuit on load side. | Check load connections carefully, clear fault. Restart controller or press button to clear faults. |
8. Specifications
8.1 Electrical Parameters
| Parameter | Tracer1206AN/1210AN G3/BLE | Tracer2206AN/2210AN G3/BLE | Tracer3210AN G3/BLE | Tracer4210AN G3/BLE |
|---|---|---|---|---|
| Battery Rated Voltage | 12/24VDC Auto-recognition | |||
| Rated Charging Current | 10A | 20A | 30A | 40A |
| Rated Discharge Current | 10A | 20A | 30A | 40A |
| Controller Work Voltage Range | 8~31V | |||
| PV Maximum Open-circuit Voltage | 60V (46V at 25°C) | 100V (92V at 25°C) | ||
| MPPT Voltage Range | (Battery voltage +2V)~36V | (Battery voltage +2V)~72V | ||
| Rated Charging Power | 130W/12V, 260W/24V | 260W/12V, 520W/24V | 390W/12V, 780W/24V | 520W/12V, 1040W/24V |
| Static Losses | <8mA(12V), <5mA(24V) | |||
| Discharge-circuit Voltage Drop | ≤0.23V | |||
| Temperature Compensation | -3mV/°C/2V (Default) | |||
| Grounding Type | Common negative | |||
| RS485 Port | 5VDC/200mA(RJ45) | |||
| LCD Backlight Time | Default:60S, Range:0~999S (0 seconds: backlight is ON all the time) | |||
| Work Temperature Range | -25°C~+45°C (100% loads working) | |||
| Storage Temperature Range | -20°C~+70°C | |||
| Relative Humidity | < 95% (N.C.) | |||
| Enclosure | IP30 | |||
8.2 Mechanical Parameters
| Model | Tracer1206/1210AN G3/BLE | Tracer2206/2210AN G3/BLE | Tracer3210AN G3/BLE | Tracer4210AN G3/BLE |
|---|---|---|---|---|
| Dimension (L x W x H) | 172x139x44mm | 220x154x52mm | 228x164x55mm | 252x180x63mm |
| Mounting Size (L x W) | 124x130mm | 170x145mm | 170x155mm | 204x171mm |
| Mounting Hole Size | Φ5mm | |||
| Terminal | 12AWG(4mm²) | 6AWG(16mm²) | 6AWG(16mm²) | 6AWG(16mm²) |
| Recommended Wire Size | 12AWG(4mm²) | 10AWG(6mm²) | 8AWG(10mm²) | 6AWG(16mm²) |
| Net Weight | 0.57kg | 0.94kg | 1.26kg | 1.65kg |
8.3 Conversion Efficiency Curves
Detailed conversion efficiency curves for various PV array maximum power point voltages and system voltages are available in the full PDF manual. These graphs illustrate the controller's performance under different operating conditions.
9. User Tips
- Ventilation is Key: Always ensure adequate airflow around the controller, especially in enclosed spaces, to prevent overheating and maintain optimal performance.
- Secure Connections: Regularly check all wire connections to ensure they are tight and free from corrosion to prevent heat buildup and potential hazards.
- Battery Type Setting: Accurately set your battery type in the controller settings (via LCD, PC, or APP) to ensure proper charging and prolong battery life. For custom battery parameters, use the "USE" setting.
- Monitor Performance: Utilize the LCD interface or the EPEVER APP to monitor real-time energy statistics and system status. This helps in early detection of any issues.
10. Warranty and Support
For detailed warranty information and conditions, please refer to the Disclaimers section of this manual. The manufacturer's warranty typically covers defects in materials and workmanship under normal use. Damage resulting from improper installation, unauthorized modification, or operation outside specified parameters may void the warranty.
For further assistance, technical support, or to access the full user manual PDF, please refer to the official EPEVER website or contact your vendor. The user manual (PDF) can be viewed here.