1. Introduction

The EPEVER XTRA-N G3/XTRA-N G3 BLE series controllers are designed with a new concept, utilizing the solar charge controller as the main component. The XTRA-N G3 BLE series features a built-in Bluetooth module, allowing users to conveniently read and modify parameters via a mobile application.

These controllers incorporate an advanced MPPT (Maximum Power Point Tracking) control algorithm, which enhances the tracking speed and minimizes power loss. This ensures the controller quickly tracks the Maximum Power Point (MPP) to maximize energy harvest under various conditions.

A notable feature is independent voltage regulation, enabling direct connection of loads to the controller's battery terminal even without a battery. This design supports various lithium batteries and prevents unstable output voltage caused by internal protection mechanisms of lithium batteries. The low self-consumption design significantly reduces static power consumption, extending system standby time.

The controller includes features like charging power/current limit and automatic charging power reduction during high temperatures, ensuring system stability when connected to excess PV modules or operating in hot environments. With IP33 ingress protection and an isolated RS485 communication port, the controller offers enhanced reliability and versatility for various applications.

The XTRA-N G3/XTRA-N G3 BLE series employs a three-stage charging mode to prolong battery lifespan and improve performance. Comprehensive electronic protections, including overcharge, over-discharge, and PV & battery reverse polarity protection, contribute to a more reliable and durable solar system. These controllers are suitable for RVs, household systems, and outdoor monitoring applications.

Key Features:

  • Advanced MPPT technology with ultra-fast tracking speed (up to 99.5% tracking efficiency).
  • Maximum DC/DC transfer efficiency up to 98.5%; full load efficiency up to 97.2%.
  • Accurate recognition and tracking of multi-peak maximum power points.
  • Wider MPP running voltage to optimize PV utilization.
  • Support for multiple battery types, including lithium batteries, with stable self-activation.
  • Built-in Bluetooth for parameter adjustment via EPEVER APP (XTRA-N G3 BLE series only).
  • RS485 communication interface with optional 4G or Wi-Fi modules for remote monitoring.
  • Constant voltage output function (requires input power higher than output power).
  • Comprehensive electronic protections.
  • Multiple load work modes.
  • Dustproof and waterproof design with IP33 enclosure.
  • Low self-consumption (lower than 10mA).
  • Operation at full load without charging power reduction in the working temperature range.
EPEVER XTRA4210N G3 BLE MPPT Solar Charge Controller
Figure 1.1: EPEVER XTRA4210N G3 BLE MPPT Solar Charge Controller
Features summary of EPEVER XTRA-N G3 series
Figure 1.2: EPEVER XTRA-N G3 Series Features Overview
Video 1.1: EPEVER XTRA-N G3 BLE Series MPPT Charge Controller Overview

2. Important Safety Instructions

Please read and follow all instructions carefully before installation and operation to prevent damage or injury.

General Safety Guidelines:

  • Read all instructions and warnings in the manual thoroughly before installation.
  • Do NOT disassemble or attempt to repair the controller; it contains no user-serviceable components.
  • Mount the controller indoors, avoiding exposure to components and water ingress.
  • Install the controller in a well-ventilated area. The heat sink can become very hot during operation.
  • Install appropriate external fast-acting fuses/breakers.
  • Disconnect all PV array connections and fast-acting fuses/breakers before controller installation and adjustment.
  • Ensure power connections are tight to prevent excessive heating from loose connections.

WARNING:

Do not install the controller in humid, high salt spray, corrosive, greasy, flammable, explosive, or dusty environments.

Other Safety Instructions (FCC Compliance):

  • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
  • This equipment has been tested and found to comply with the limits for a Class B digital device. It generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications.
  • If interference occurs, try to reorient or relocate the receiving antenna, increase separation between equipment and receiver, connect equipment to a different circuit, or consult a dealer/technician.
  • This equipment complies with FCC radiation exposure limits for an uncontrolled environment. It should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

3. Installation

3.1 Attentions

  • Be very careful when installing batteries, especially flooded lead-acid batteries. Wear eye protection and have fresh water available to wash off any battery acid contact.
  • Keep batteries away from metal objects to prevent short circuits.
  • Ensure good ventilation as explosive battery gases may be released during charging.
  • Ventilation is highly recommended if mounted in an enclosure. Never install the controller in a sealed enclosure with flooded batteries, as battery fumes can corrode and destroy circuits.
  • Loose power connections and corroded wires can cause high heat, melting insulation, burning materials, or fire. Ensure tight connections, use cable clamps, and prevent swaying in mobile applications.
  • The controller is compatible with lead-acid and lithium batteries.
  • Battery connections can be wired to a single battery or a bank of batteries.
  • Select system cables according to 5A/mm² or less current density (National Electrical Code, NFPA 70, Article 690).
  • Grounding wire size should be no less than 4mm².
  • Tighten wiring screws to a torque of at least 1.2N.m.

3.2 PV Array Requirements

The controller is suitable for various PV modules and maximizes solar energy conversion. The series number of different types of PV modules can be calculated based on the open-circuit voltage (Voc) and maximum power point voltage (VMpp) of the MPPT controller.

CAUTION:

When PV modules are connected in series, the open-circuit voltage of the PV array must not exceed 46V (for XTRA**06N G3/BLE), 92V (for XTRA**10N G3/BLE), or 138V (for XTRA**15N G3/BLE) at 25°C.

3.3 Wire Size

Wiring and installation methods must comply with national and local electrical code requirements.

NOTE:

  • The wire size is for reference only. For long distances between the PV array, controller, and battery, use larger wires to reduce voltage drop and improve performance.
  • The recommended battery wire is selected when the battery terminals are not connected to any additional inverter.

3.4 Mounting

The controller should be installed in a location with sufficient airflow through its radiators. Maintain a minimum clearance of 150 mm from the upper and lower edges of the controller to ensure natural thermal convection.

Mounting dimensions for EPEVER MPPT Solar Charge Controller
Figure 3.1: Mounting Dimensions (150mm clearance recommended)

WARNING:

  • Risk of explosion! Never install the controller in a sealed enclosure with flooded batteries or in a confined area where battery gas can accumulate.
  • Risk of electric shock! When wiring solar modules, the PV array can produce a high open-circuit voltage. Disconnect the breaker before wiring and be careful.

CAUTION:

The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.

3.5 Wiring Connection Steps:

  1. Connect the system in the order of: Battery → Load → PV array.
  2. Disconnect the system in the reverse order: PV array → Load → Battery.
Wiring diagram for EPEVER MPPT Solar Charge Controller in Battery Mode
Figure 3.2: Schematic Wiring Diagram (Battery Mode)

3.6 No-Battery Mode

When no battery is present, the XTRA-N G3/XTRA-N G3 BLE series can be directly connected to an inverter. The inverter must be connected to the battery terminals of the controller and meet the following conditions:

  • For high-frequency inverters: PV input power > (load output power ÷ inverter conversion efficiency ÷ controller conversion efficiency)
  • For power frequency inverters: PV input power > (load output power ÷ inverter conversion efficiency ÷ controller conversion efficiency ÷ 2)
Wiring diagram for EPEVER MPPT Solar Charge Controller in No-Battery Mode
Figure 3.3: Schematic Wiring Diagram (No-Battery Mode)

3.7 Grounding

XTRA-N G3/XTRA-N G3 BLE series are common-negative controllers. All negative terminals can be grounded simultaneously, or any one can be grounded. For practical applications, the negative terminals of the PV array, battery, and load can also be ungrounded. However, the grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.

NOTE:

A common-negative controller is recommended for common-negative systems, such as motorhomes. The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in a common-negative system.

3.8 Connecting Accessories

Connect the remote temperature sensor cable to the controller's interface and place the other end close to the battery.

CAUTION:

If the remote temperature sensor is not connected, the default battery charging or discharging temperature setting is 25°C (no temperature compensation).

For RS485 communication accessories, refer to the 'Parameters Setting' section.

3.9 Powering On the Controller

Connect the battery's fast-acting fuse to power the controller. Check the battery indicator's status (it should be lit green for normal operation). Then, connect the fast-acting fuse and circuit breaker of the load and PV array. The system will then operate in preprogrammed mode.

CAUTION:

If the controller is not operating properly or the battery indicator shows an abnormality, refer to the 'Troubleshooting' section.

4. Display Units

The controller features an integrated display unit for monitoring system status and parameters.

EPEVER MPPT Solar Charge Controller display unit
Figure 4.1: Controller Display Unit

4.1 Indicators

IndicatorColorStatusInstruction
PV ArrayGreenOn SolidPV charges the battery with a low current
GreenOFF1. No sunlight
2. Connection error
3. Low PV voltage
GreenSlowly Flashing (1Hz)Normal charging
BatteryGreenFast Flashing (4Hz)PV Over voltage
GreenOn SolidNormal
GreenSlowly Flashing (1Hz)Full
LoadGreenFast Flashing (4Hz)Overvoltage
OrangeOn SolidUnder voltage
RedOn SolidOver discharged
TemperatureRedSlowly Flashing (1Hz)Battery Overheating
Lithium battery Low temperature
YellowOn SolidLoad ON
SystemYellowOFFLoad OFF
PV&BATT LEDFast flashingController Overheating
System voltage error

4.2 Buttons

The controller features several buttons for navigation and setting parameters:

  • PV/+ Button: Browses PV parameters, sets data, or selects battery type/temperature unit.
  • BATT/- Button: Browses battery parameters, moves cursor during setting, or selects battery type/temperature unit.
  • LOAD/- Button: Browses load parameters, sets data, or changes load working mode.
  • SET Button: Enters setting interface, switches to browsing interface, confirms settings.
  • O/ESC Button: Exits setting interface.

4.3 Display

The display screen shows various parameters including voltage, current, power, generated energy, battery temperature, and battery capacity level. It also indicates the load working mode.

NOTE:

The display screen is best viewed when the angle between the user's horizontal sight and the display screen is within 90°. Beyond 90°, information may not be clearly visible.

5. Parameters Setting

5.1 Battery Parameters

The controller supports various battery types. If the controller supports 48V system voltage, LiFePO4 F15/F16 and Li(NiCoMn)O2 N13/N14 battery types will be displayed.

TypeBattery
1Sealed (default)
Gel
Flooded
2Lithium batteryLiFePO4 (4S/8S/15S/16S)
Li(NiCoMn)O2 (3S/6S/7S/13S/14S)
3User

WARNING:

When the default battery type is selected, battery voltage parameters cannot be modified. To change these parameters, select the 'USE' type.

5.2 Local Setting of Battery Parameters

To set battery parameters on the local device, first enter the 'USE' battery type. The SYS value can only be modified under non-lithium 'USE' types. If the battery type is Sealed, Gel, or Flooded before entering 'USE', the SYS value can be modified. If it's a lithium battery type, the SYS value cannot be modified.

5.3 Remote Setting of Battery Parameters

Battery parameters can be set remotely via PC software, external WiFi/Bluetooth modules, or the MT52 remote meter.

  • Via PC Software: Connect the controller's RJ45 interface to the PC's USB interface via a USB to RS485 cable. Set voltage parameters using the PC software when 'USE' battery type is selected.
  • Via External WiFi Module: Connect the controller to an external WiFi module via the RS485 communication port. Set voltage parameters using the APP after selecting 'USE' battery type.
  • Via External Bluetooth Module: Connect the controller to an external Bluetooth module via the RS485 communication port. Set voltage parameters using the APP after selecting 'USE' battery type.
  • Via Built-in Bluetooth Module (XTRA-N G3 BLE series only): Connect your mobile phone to the built-in Bluetooth module. Set voltage parameters using the APP after selecting 'USE' battery type.
  • Via MT52 Remote Meter: Connect the controller to the MT52 remote meter via a standard network cable. Set voltage parameters using the MT52 when 'USE' battery type is selected.
EPEVER MPPT Solar Charge Controller with phone app for Bluetooth monitoring
Figure 5.1: Built-in Bluetooth for APP Monitoring
EPEVER MT52 Remote Meter
Figure 5.2: MT52 Remote Meter

5.4 Load Modes

The controller offers multiple load working modes, which can be configured via the LCD or remotely.

  • Manual Mode (Default): Control load ON/OFF via the button or remote commands (PC software, APP, or remote meter).
  • Light ON/OFF Mode: Load turns ON/OFF based on light conditions.
  • Light ON/OFF + Timer Mode: Combines light sensing with a timer for specific ON/OFF durations (e.g., night on and day off, or day on and night off).
  • Always ON Mode: Load maintains output state, suitable for loads requiring 24-hour power supply.
  • Test Mode: For testing purposes.

NOTE:

When selecting Light ON/OFF, Test, or Manual mode, only Timer 1 can be set; Timer 2 is disabled.

5.5 RS485 Communication Setting

The RS485 communication port supports 5V output and communication functions when enabled. Disabling it reduces the system's self-consumption. This setting can be enabled/disabled via the LCD or remotely.

6. Protection Features

The controller incorporates comprehensive protection mechanisms to ensure safe and reliable operation of your solar system.

ProtectionDescription
PV Over Current/Over PowerWhen PV array charging current or power exceeds rated values, the controller will charge at the rated current or power.

WARNING:

If the PV's charging current is higher than the rated current, the PV's open-circuit voltage cannot exceed the maximum PV open-circuit voltage, otherwise, the controller may be damaged.

PV Short CircuitWhen not in a PV charging state, the controller will not be damaged by a short-circuit in the PV array.

WARNING:

It is forbidden to short-circuit the PV array during charging, otherwise, the controller may be damaged.

PV Reverse PolarityIf the PV array polarity is reversed, the controller may not be damaged and can operate normally after correction.

CAUTION:

The controller is damaged if the PV array is connected reversely and its actual operating power exceeds 1.5 times the rated charging power.

Night Reverse ChargingPrevents the battery from discharging to the PV module at night.
Battery Reverse PolarityThe battery can be reversely connected when the PV is disconnected or reversely connected. Correct the wire connection to resume work.

WARNING:

The controller will be damaged if the PV connection is correct and the battery connection is reversed!

Battery Over VoltageWhen battery voltage exceeds the Over Voltage Disconnect Voltage, the controller stops charging to protect the battery from overcharge.
Battery Over DischargeWhen battery voltage is lower than the Low Voltage Disconnect Voltage, the controller stops discharging to protect the battery from over-discharge.
Battery Over-heatingThe controller detects battery temperature via an external sensor. It stops working if temperature exceeds 65°C and restarts below 55°C.
Lithium Battery Low TemperatureIf the temperature detected by the optional sensor is lower than the Low Temperature Protection Threshold (LTPT), the controller stops charging and discharging. It resumes when the temperature rises above LTPT. (LTPT is 0°C by default, settable within 10°C to -40°C).
Load Short CircuitIf the load is short-circuited (current ≥ 4 times rated load current), the controller automatically cuts off output. If the load reconnects five times (with delays), it needs to be canceled by pressing the Load button, restarting the controller, or waiting for one night-day cycle.
OverloadIf the load is overloading (current ≥ 1.02 times rated load current), the controller automatically cuts off output. If the load reconnects five times (with delays), it needs to be canceled by pressing the Load button, restarting the controller, or waiting for one night-day cycle.
Controller Over-heatingThe controller detects its internal temperature. It stops working if internal temperature exceeds 85°C and resumes below 75°C. When internal temperature is 81°C, reduced charging power mode activates (5-40% reduction for every 1°C increase).
TVS High Voltage TransientsInternal circuitry includes Transient Voltage Suppressors (TVS) for protection against high-voltage surge pulses with less energy. For areas with frequent lightning, an external surge arrester is recommended.

7. Troubleshooting

This section provides solutions for common issues encountered with the controller.

Possible ReasonFaultsTroubleshooting
PV array disconnectionCharging LED indicator off during daytime when sunshine falls on PV modules properly.Confirm that PV wire connections are correct and tight.
Battery voltage is lower than 8VThe wire connection is correct, and the controller is not working.Check battery voltage. At least 8V is needed to activate the controller.
Battery over voltageGreen charging indicator fast flashes. Battery level shows full, battery frame and fault icon blink.Check if battery voltage is higher than OVD (over voltage disconnect voltage), and disconnect the PV.
Battery over-dischargedRed charging indicator is ON solid. Battery level shows empty, battery frame and fault icon blink.When battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover.
Battery OverheatingRed battery indicator slow flashes. Battery frame and fault icon blink.The controller will automatically turn the system off. When the temperature declines to below 55°C, the controller will resume.
Controller OverheatingPV and BATT indicators fast flash.When the heat sink of the controller exceeds 85°C, the controller will automatically cut off the input and output circuit. When the temperature is below 75°C, the controller will resume work.
System voltage errorPV and BATT indicators fast flash.1. Check whether the battery voltage matches the system voltage level set on the controller.
2. Change a matched battery or modify the system voltage level. (Note: This fault can be ignored for no-battery application if system voltage level matches actual system voltage. Alarm disappears after 3 minutes or by pressing Load button).
Load Short Circuit1. The load has no output.
2. LCD blinks "E001."
3. Load and fault icons blink.
1. Check load connection carefully, and cancel the fault.
2. Restart the controller.
3. Wait for one night-day cycle (night time > 3 hours).
Load Overload1. The load has no output.
2. LCD blinks "E002."
3. Load and fault icons blink.
1. Reduce the number of electric equipment.
2. Restart the controller.
3. Wait for one night-day cycle (night time > 3 hours).

8. Maintenance

The following inspections and maintenance tasks are recommended at least twice yearly for optimal performance.

  • Ensure the controller is firmly installed in a clean and dry environment.
  • Ensure no obstructions to airflow around the controller. Clean any dirt or fragments from the heat sink.
  • Check all exposed wires for insulation damage (due to sun, friction, wear, dryness, insects, or rodents). Repair or replace damaged wires as necessary.
  • Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
  • Check and confirm that the LED indicators are consistent with requirements. Pay attention to any troubleshooting or error indications and take corrective action.
  • Confirm that all system components are tightly and correctly grounded.
  • Confirm that all terminals show no corrosion, insulation damage, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
  • Clean up dirt, nesting insects, and corrosion promptly.
  • Check and confirm that the lightning arrester is in good condition. Replace it if necessary to prevent damage to the controller and other equipment.

WARNING: Risk of electric shock!

Ensure all power is turned off before performing any inspections or operations.

9. Technical Specifications

The following tables detail the electrical, mechanical, and environmental specifications for the EPEVER XTRA4210N G3 BLE MPPT Solar Charge Controller.

9.1 Electrical Parameters (XTRA4210N G3 BLE)

ParameterValue
Nominal System Voltage12/24VDC Auto
Controller Work Voltage Range8~31V
Rated Charge Current40A
Rated Discharge Current40A
Rated Charge Power (12V/24V)520W/1040W
Max. Conversion Efficiency98.60%
Max. Load Efficiency96.50%
MPP Voltage Range(Battery Voltage+2V)~72V
Max. PV Open-circuit Voltage (Min. Env. Temp.)100V
Max. PV Open-circuit Voltage (25°C Env. Temp.)92V
Temperature Compensation-3mV/°C/2V (Default)
EnclosureIP33
Communication InterfaceRS485 (RJ45)
GroundingCommon Negative
Operating Temperature Range-25°C~50°C
Dimensions (LxWxH)255 x 185 x 67.8 mm
Net Weight1.72kg

9.2 Conversion Efficiency Curves (Example for 13V System)

MPPT Technology Tracking Efficiency graph
Figure 9.1: MPPT Technology Tracking Efficiency
13V Conversion Efficiency Curves for EPEVER XTRA1210N G3/BLE
Figure 9.2: 13V Conversion Efficiency Curves (XTRA1210N G3/BLE)

For detailed conversion efficiency curves for other models and system voltages, please refer to the full user manual PDF.

10. User Tips

  • For optimal performance, ensure the controller is installed in a location with good ventilation to prevent overheating, especially during high load operation.
  • Regularly check wire connections for tightness to avoid power loss and potential hazards.
  • When using lithium batteries, remember that the system voltage is not automatically identified. Ensure correct manual configuration.
  • Utilize the built-in Bluetooth feature with the EPEVER app for convenient monitoring and parameter adjustments from your smartphone.

11. Warranty and Support

This product is manufactured by EPEVER. For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.

The warranty does not cover damage caused by improper use, inappropriate environment, exceeding limit values, working temperature outside the rated range, failure to follow instructions, unauthorized dismantling, force majeure, or damage during transportation/handling.

For the complete and most up-to-date user manual, including detailed diagrams and specifications, please refer to the official PDF document: EPEVER MPPT Solar Charge Controller User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.