RCYAGO YY-400

RCYAGO YY-400 Digital 4-in-1 Water Quality Tester

User Manual

Product Overview

The RCYAGO YY-400 is a high-precision, multifunctional water quality tester designed to measure pH, Oxidation-Reduction Potential (ORP), hydrogen ion concentration (H2), and water temperature. It features automatic temperature compensation, an easy-to-read LCD digital display with backlight, and a robust IP67 waterproof rating. This device is suitable for a wide range of applications including household water, swimming pools, ponds, aquariums, hydroponics, laboratories, and food processing.

YY-400 4-in-1 Water Quality Tester with H2, PH, ORP, Temperature, IP67, and Backlit Display features
Figure 1: YY-400 4-in-1 Water Quality Tester with key features highlighted.

Package Contents

Upon opening your package, please ensure all items are present and in good condition:

  • 1 x RCYAGO YY-400 Multi-function Meter
  • 3 x pH Buffer Powder packets (for calibration)
  • 1 x User Manual
YY-400 package contents including meter, calibration powders, and manual
Figure 2: Contents of the YY-400 product package.

Setup

1. Battery Installation

The YY-400 meter requires 3 x 1.5V LR44 button batteries (not included). To install or replace batteries:

  1. Unscrew the battery compartment cap located at the top of the meter.
  2. Insert the three LR44 batteries, ensuring correct polarity (+/-).
  3. Securely screw the cap back on.
Diagram showing battery compartment, power button, mode/cal key, hold/temp key, screen, protective cap, and high precision probe of the YY-400 meter
Figure 3: Components of the YY-400 meter, including battery compartment.

2. Probe Attachment (if applicable)

The YY-400 features a detachable probe design, which helps prevent accidental damage and allows for easy replacement. To attach or detach the probe:

  1. Gently twist the protective cap to remove it.
  2. Align the probe's connector with the meter's socket.
  3. Push and twist gently until the probe is securely in place.
Close-up view of the detachable probe design of the YY-400 water quality tester
Figure 4: Detachable probe design for easy replacement.

3. Initial Calibration (pH)

The product is calibrated before leaving the factory. However, for optimal accuracy, especially after prolonged storage or if readings seem inaccurate, pH calibration is recommended. The YY-400 supports 1-point, 2-point, or 3-point automatic calibration.

  1. Prepare the pH buffer solutions (e.g., pH 4.00, pH 6.86, pH 9.18) by dissolving the provided powder packets in 250ml of distilled water each.
  2. Turn on the meter.
  3. Immerse the electrode into the pH 4.00 buffer solution.
  4. Press and hold the "CAL" button for 5 seconds until the display flashes "CAL" and then the pH value. The meter will automatically recognize the solution and complete the calibration (flashing 3 times).
  5. Rinse the electrode with distilled water.
  6. Repeat steps 3-5 for pH 6.86 and pH 9.18 solutions if performing a 3-point calibration.
Video 1: Demonstrates the pH calibration process using buffer solutions.

Operating Instructions

1. Power On/Off

Press the power button (usually marked with a power symbol) to turn the meter on or off.

2. Taking Measurements

  1. Remove the protective cap from the electrode.
  2. Rinse the electrode with distilled water before each use.
  3. Immerse the electrode into the sample solution, ensuring the liquid level is below the maximum immersion line.
  4. Gently stir the meter and wait for the reading to stabilize on the LCD display.
  5. The meter features automatic temperature compensation (ATC) from 0-60℃, ensuring accurate readings regardless of temperature fluctuations.
  6. After measurement, press the "HOLD/TEMP" button to hold the current reading on the screen. Press again to release.
  7. Rinse the electrode with distilled water and replace the protective cap after use.

3. Switching Measurement Modes

The YY-400 can measure PH, ORP, H2 (ppb/ppm), and Temperature. To switch between modes:

  • Press the "MODE/CAL" button repeatedly to cycle through the different measurement parameters (PH, ORP/mV, H2/ppb, H2/ppm).
YY-400 display showing different measurement modes: PH, ORP/mV, H2/ppb, H2/ppm
Figure 5: The meter's display cycling through various measurement modes.

4. Understanding ORP Readings

ORP (Oxidation-Reduction Potential) indicates the water's ability to oxidize or reduce contaminants. Higher positive ORP values indicate greater oxidizing potential, while negative values indicate reducing potential.

  • Freshwater fish tank ORP: approximately 230-260mV.
  • Seawater fish tank ORP: approximately 350-450mV.
YY-400 measuring ORP in a fish tank, with typical ORP values for freshwater and seawater
Figure 6: ORP measurement and typical values for aquatic environments.

5. Understanding pH Readings

pH measures the acidity or alkalinity of water. A pH of 7 is neutral, below 7 is acidic, and above 7 is alkaline.

YY-400 measuring pH with a color scale indicating acidity, neutral, and alkalinity
Figure 7: pH measurement with an illustrative acidity/alkalinity scale.

6. Automatic Shutdown

The meter will automatically shut down after 5 minutes of inactivity to conserve battery life.

7. Waterproof Rating

The YY-400 is IP67 waterproof, meaning it is protected against dust penetration and can withstand short periods of immersion in water.

YY-400 meter submerged in water, demonstrating its IP67 waterproof feature
Figure 8: The IP67 waterproof rating ensures protection against dust and temporary immersion.

Maintenance

1. Electrode Cleaning and Storage

After each use, always wash the electrode with pure water (distilled or deionized water) and gently wipe it dry. Replace the protective cap to prevent damage and keep the electrode moist. Proper cleaning and storage are crucial for maintaining electrode accuracy and lifespan.

2. Probe Replacement

If the probe becomes damaged or its performance degrades significantly, it can be replaced due to its detachable design. Refer to the "Probe Attachment" section under Setup for instructions on detaching and attaching a new probe.

Troubleshooting

Inaccurate Readings or Calibration Failure

  • Check Calibration: Ensure the meter is calibrated regularly, especially if it hasn't been used for a while or if you suspect inaccurate readings. Use fresh buffer solutions.
  • Electrode Condition: A dirty or dry electrode can lead to inaccurate readings. Clean the electrode thoroughly with pure water. If the electrode is old or damaged, consider replacing it.
  • Buffer Solution Quality: Ensure your pH buffer powders are fresh and mixed correctly with distilled water. Expired or contaminated buffer solutions will lead to incorrect calibration.
  • Temperature: While the meter has ATC, extreme temperature differences between the meter and the sample can affect initial stability. Allow the meter to equilibrate with the sample temperature.
  • Battery Level: Low battery can affect performance. Replace batteries if the display is dim or erratic.

If the instrument does not recognize the solution during calibration, or if issues persist after troubleshooting, please contact your supplier for further assistance.

Specifications

ParameterSpecification
Model NumberYY-400
Brand NameRCYAGO
Display TypeDIGITAL
BacklightYes
Is Smart DeviceNo
PH Range0.01-14.00pH
PH Resolution0.01pH
PH Accuracy±0.05pH
ORP Range±999mV
ORP Resolution1mV
ORP Accuracy±2mV
H2 Range0-2400ppb; 0.001-2.400ppm
H2 Resolution2ppb; 2ppm
H2 Accuracy±10ppb; ±10ppm
Temperature Range0.1-60.0°C (32.0-140°F)
Temperature Resolution1℃/°F
Temperature Accuracy±0.5
Automatic Temperature Compensation0-60℃
Working Environment0-60℃ (32.0-140°F)
Waterproof RatingIP67
Automatic Shutdown5 minutes
Data RetentionValue retention
Battery Supply3*1.5V (LR44)
Screen Size33 * 24mm
Dimensions183*37*37mm (7.2*1.5*1.5in)
Weight90g
CertificationCE
YY-400 product dimensions and features like LCD HD display and easy portability
Figure 9: Physical dimensions and key features of the YY-400 meter.

User Tips

  • Regular Calibration: For the most accurate pH readings, calibrate your meter regularly, especially if you are testing a wide range of pH values or if the meter has been stored for an extended period.
  • Proper Cleaning: Always rinse the electrode with distilled or deionized water after each use to prevent contamination and ensure longevity. Never use tap water for rinsing as it can leave mineral deposits.
  • Storage: Store the electrode with its protective cap on, ideally with a few drops of electrode storage solution or pH 4.00 buffer solution inside the cap to keep the sensor moist. Avoid storing it dry.
  • Battery Check: Keep spare LR44 batteries on hand. A low battery can lead to unstable or inaccurate readings.
  • Avoid Disassembly: Do not attempt to disassemble the meter without authorization, as this may void any warranty and could damage the device.

Warranty and Support

The RCYAGO YY-400 Digital 4-in-1 Water Quality Tester is designed for reliability and accuracy. For any technical support, warranty claims, or questions regarding the operation or maintenance of your device, please contact your original point of purchase or the manufacturer directly. Please retain your purchase receipt as proof of purchase.

The product is CE certified, indicating compliance with European safety, health, and environmental protection requirements.

Related Documents - YY-400

Preview DO-9100 Pen Type Intelligent Dissolved Oxygen Analyzer Instruction Manual
This document provides instructions for the DO-9100 pen type intelligent dissolved oxygen analyzer, covering its features, technical parameters, operation, maintenance, and troubleshooting.
Preview RCYAGO SGW07 Dual Water Timer User Manual
Comprehensive user manual for the RCYAGO SGW07 Dual Water Timer. Learn about product overview, specifications, installation, automatic watering programs, manual watering, rain delay, troubleshooting, and battery status for your garden irrigation system.
Preview Noyafa Water Quality Meter Operation Manual
Operation manual for Noyafa pen-type water quality meters, covering troubleshooting, attention points, warranty, return authorization, and detailed parameter specifications for various models.
Preview Pen Type Water Quality Meter Operation Manual: pH, TDS, EC, SALT, ORP Measurement
Comprehensive operation manual for the pen-type water quality meter. Covers troubleshooting, calibration, parameters, and usage for measuring pH, TDS, EC, SALT, ORP, H2, and S.G. Includes detailed guides for models like EZ9901, C-600, and more.
Preview YY-103 Series Intelligent pH Meter Instruction Manual
Comprehensive instruction manual for the YY-103 Series Intelligent pH Meter, covering parameters, functions of different models, operation, app usage, and calibration procedures. Includes details on electrode types, specifications, and quality assurance.
Preview Braun No Touch+ Thermometer BNT 400: Features, Usage, and Fever Guide
Comprehensive guide to the Braun No Touch+ thermometer (BNT 400), detailing its advanced AgeSmart technology, dual measurement modes (no-touch and touch), easy-to-read color-coded display, and instructions for accurate temperature readings for individuals and liquids.